• Title/Summary/Keyword: Standard fire

Search Result 859, Processing Time 0.036 seconds

An Effectiveness of Temperature-Dependency Thermal Properties in Transient Thermal Analysis of Concrete Structures Exposed to Fire (화재시 콘크리트의 열특성계수가 비정상 열전달해석에 미치는 영향)

  • Lee, Jae-Young;Han, Byung-Chan;Kim, Jae-Hwan;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.11-14
    • /
    • 2008
  • This paper is currently being conducted to develop a nonlinear finite element analysis methods for predicting the structural behavior of reinforced concrete structures, exposed to fire. The changes in thermal parameters are discussed from the point of view of changes of structure and chemical composition due to the high temperature exposure. Although, this study considers codes standard fire for reinforced concrete frame, any other time-temperature relationship can be easily incorporated.

  • PDF

A Study on Building the Regional Cluster: The Case of Fire and Emergency Industrial Cluster in Samcheok-si

  • Lee, Dong-Kyu;Yang, Gi-Geun
    • International Journal of Contents
    • /
    • v.5 no.3
    • /
    • pp.57-64
    • /
    • 2009
  • Korea has relied on top down development method, in which companies, research and education institutions move into the industrial complexes established by the government. However, to improve local competitiveness, the paradigm is shifting from the government initiated industrial complex to the clusters based on the cooperative network of the region. Representative case is 'Samcheok-si Fire & Emergency industry cluster construction project' that begun in 2007. AHP technique analysis results on first-stage showed that priority was on policy and network elements, and the results of second-stage analysis show that priority was on Policy incentives to internationalize the cluster and strengthen link,. Cluster branding, Sharing of organizational culture to cope with changes in environment, Creation of group learning culture. The subject of this research is limited to Samcheok-si's the Fire and Emergency Industry cluster formation project. Therefore, the research area and standard should be expanded to increase generality in further researches.

IR 불꽃화재감지기 개발

  • Gwon, O-Seung;Lee, Bok-Yeong;Park, Sang-Tae
    • Fire Protection Technology
    • /
    • s.29
    • /
    • pp.39-45
    • /
    • 2000
  • All objects emit thermal radiation and this radiation is the basis of the techniques used to detect flames. The usual phenomena occurring in the initial stage of a fire are generally invisible products of a combustion and visible smoke. Liquid or gaseous materials do not undergo a smoldering stage such fires develop very rapidly. Also, the heat generated by the initial flames is usually not sufficient to active a heat detector. In this case the most effective criterion for automatic fire detection is the flame. In fire regulation of korea, the compulsory standard provided that a flame detector shall be installed a place of the attachment hight of detector is higher than 20 m, chemical plants, hangar, refinery, etc.. The result of the research and development are discriminated between a flame and other radiant emitters, developed PZT pyroelectric element is based on the use of photo-voltanic cell, developed IR band-pass filter that only allow a 4.3 radiation wavelength to reach the sensors and developed IR flame detector.

  • PDF

A STUDY ON THE RISK PROTECTION OF THE MOLD TRANSFORMER

  • Chung, Young-Ki;Jung, Jong-Wook;Kim, Jae-Chul;Kwak, Hee-Ro;Lee, Su-Kyung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.219-226
    • /
    • 1997
  • This paper investigates and analyzes the installation and failure status of mold transformer being used in domestic subways and describes the extinguishing process by time through the combustion test of winding part of mold transformer. Condition of installed mold transformers and classes of fire were surveyed and the mold transformer was burned in a horizontal heating furnace. It was confirmed that the mold transformer is self extinguishing and nonflammability. According to this results, the suitable standard of fire protection for the mold transformer was demanded after review of domestic and abroad law. It is expected that the cost of fire protection equipment can be reduced by using the status and combustion test result of mold transformer.

  • PDF

A Novel Design of the Distributed Fire Alarm Control System by Developing Intelligent Control Modules with LonTalk Protocol

  • Hong, Won-Pyo;Goo, Sung-Hoan;Park, Won-Guk
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.70.6-70
    • /
    • 2001
  • There are many economic and operational reasons to integrate fire alarm signaling system with other building automation system. Integration of this requires communication standard and careful design practices. The important point for this is also the development of intelligent control modules for replacing the conventional zone adapter in fire system. Therefore, this paper proposes an new conceptual design of the distributed fire alarm signaling system and a new intelligent control modules with LonTalk Protocol. Newly proposed additions to Lonworks network make it very well suited for integration fire systems with other building automation systems. Additionally, it is very important that best design practices ...

  • PDF

Fireproof Performance Study of ICT Fire Damper by Using Experimentalmethode (실험적 방법에 의한 ICT 파이어 댐퍼의 내화성능연구)

  • Hur, Nam-Soo;Kim, In-Whan;Jang, Sung Cheol;Kim, Jae-Woong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.5
    • /
    • pp.82-89
    • /
    • 2014
  • In this paper, fire resistance test was carried out to obtain class H-120 thermal insulation of fire dampers according to a hydrocarbon fire conditions. Specimens were fabricated three different types according to the change of the insulation system applied to damper blade and coaming which were measured surface temperature by performing the fire resistance test. As a test result, specimen-1, 2 of an uninsulated damper blade were exceeded thermal insulation acceptance criteria at 21 minutes, 46 minutes respectively, but specimen-3 of an insulated damper blade was satisfied thermal insulation acceptance criteria during 120 minutes. The test results showed that the insulation of the damper blade was an important factor in the fireproof performance of fire dampers concerning the coaming length minimum 500 mm on the unexposed side as specified test standard.

Consideration about the Fire Lane Plan and the Conformability - A Case Study on Daegu Metropolitan City Buk-gu - (소방차전용출동경로의 계획기법 및 적합성 검토에 관한 연구 - 대구광역시 북구를 대상으로 -)

  • Jeong, Gun-Sik;Kim, Han -Su
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.83-90
    • /
    • 2010
  • The purpose of this study is to establish the standard of fire lane design to improve the performance of disaster prevention in local area. To accomplish it, we have focused on three research methods as below: first, we have expected disaster occurrence based on emergency tendency in local area; second, we have verified fire lane routes design through fire lane modeling and network analysis; third, we have quantitatively examined a possibility of danger of fire lanes through current road network modeling and analysis. The result of this study could be helpful to effective fire lane designs and quantitative analyses.

Security Communication Implementation and Experiments for USN Fire Prevention System (USN 화재방재 시스템을 위한 보안 통신 구현 및 실험)

  • Kim, Young-Hyuk;Lim, Il-Kwon;Lee, Jae-Kwang
    • The Journal of Korean Association of Computer Education
    • /
    • v.13 no.6
    • /
    • pp.99-104
    • /
    • 2010
  • USN Fire Prevention System is an intelligent system that detects the fire through the value which has got from a sensor such as temperature, humidity, intensity of illumination, acceleration, carbon dioxide(CO2) and so on. And then send it to the operator also use the algorithmic fire detection to operate fire extinguish system on. It is among U-Disaster Prevention System which has prevented fire lately. Configuration of the packet was designed to make the most of lightweight and fast processing for low power consumption. Recently listed in the encryption algorithm is applied each DES, 3DES, AES and HIGHT. So objective was to faster encryption than encryption of high-performance finally domestic standard encryption algorithm HIGHT were suitable for the fire prevention system needed frequent sensing time.

  • PDF

Simplified P-M interaction curve model for reinforced concrete columns exposed to standard fire

  • Lee, Deuck Hang;Cheon, Na-Rae;Kim, Minsu;Lee, Jungmin;Oh, Jae-Yuel;Kim, Kang Su
    • Computers and Concrete
    • /
    • v.19 no.5
    • /
    • pp.545-553
    • /
    • 2017
  • In the authors' previous study, an axial force-flexural moment (P-M) interaction curve model was proposed to evaluate fire-resisting performances of reinforced concrete (RC) column members. The proposed method appeared to properly consider the axial and flexural strength degradations including the secondary moment effects in RC columns due to fire damage. However, the detailed P-M interaction curve model proposed in the authors' previous study requires somewhat complex computational procedures and iterative calculations, which makes it difficult to be used for practical design in its current form. Thus, the aim of this study was to develop a simplified P-M interaction curve model of RC columns exposed to fire considering the effects of fire damage on the material performances and magnitudes of secondary moments. The simplified P-M interaction model proposed in this study was verified using 66 column fire test results collected from literature, and the verification results showed that the proposed simplified method can provide an adequate analysis accuracy of the failure loads and fire-resisting times of the RC column specimens.

A Study on the Classification of Domestic Fire Detector using Response Time Index (반응시간지수(Response Time Index)를 이용한 국내 화재감지기 등급분류에 관한 연구)

  • Hong, Sung Ho;Kim, Dong Suck;Choi, Ki Ok
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.46-51
    • /
    • 2017
  • This paper presents classification of domestic fire detector using response time index. Response time is measured using fire detector distributed in Korea, and the response time index is estimated. Plunge test prescribed by FM is conducted to measure response time of fire detector. The detector used to test is fixed temperature type(thermistor and bimetal type) and rate of rise temperature type(thermistor and pneumatic type). The nominal operation temperature of fixed temperature type detector is $70^{\circ}C$ and rate of rise temperature is $15^{\circ}C/min$. The fixed temperature type is measured 7 products, and the rate of rise temperature type is measured 5 products. The results show that in case of fixed temperature type(thermistor) is classified "Quick" or "Standard" and fixed temperature type(bimetal) is not classified. The rate of rise temperature type(thermistor) is classified "Fast" or "Ultra Fast" and the rate of rise temperature type(pneumatic) is classified "Very Fast" or "Ultra Fast". The pneumatic type shows more fast response than thermistor type. Also these results indicate the fixed temperature type(bimetal) is not suitable for early stage fire detection.