• Title/Summary/Keyword: Standard facility

Search Result 926, Processing Time 0.026 seconds

A Study on the Fire Risk of Urban type housing constructed by pilotis structures, -In the case of Uijeongbu fire- (필로티구조 도시형생활주택의 화재위험성에 관한 연구 -의정부사례를 바탕으로-)

  • Hwang, Eu-Cheong;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.50-51
    • /
    • 2017
  • The Urban-type building is an building that it relaxed the construction standard and subsidiary facility standard. The most of the urban-type buildings are pilotis, the main case of representing these building's fire risk is the Uijeongbu fire this study investigated to piloti urban type housing risk on the basis of Uijeongbu fire, and we checked structural problem that unable to escape from the rooftop inside the piloti. also, there was confirmed limit to the evacuation of the occupants because the smoke was rapidly transferred to the top layer through inside the electric duct. and when we analyzed smoke flow use of Fire simulation, it was confirmed Available Safety Egress Time that is four minutes of CO.

  • PDF

An Analysis on the status of Measurement Investment in Korean Industry (한국산업의 계측투자실태분석)

  • Kim, Dong-Jin;Nam, Gyeong-Hui
    • Journal of Korean Society for Quality Management
    • /
    • v.20 no.2
    • /
    • pp.76-93
    • /
    • 1992
  • The purpose of this study, by surveying the status of firms, measurement-related investment and the defect rate, is to analyze the effect of measurement-related investment and to propose a scheme of efficient measurement-related investment which reduces the defect rate. For this project we obtain the data of the status of the measurement-related investment and the defect rate of 928 firms in Korean manufacturing industry by mailing survey. One of our results shows that the firms which have measurement standard laboratory, i.e, which invest in measurement-related area comparatively high, have the defect rate about 0.8% lower than those firms which don't have measurement standard laboratory. Also we find that the small-and-middle size firms have worse measurement-related facility than the large firms and the firms in the heavy-chemical industry have higher measurement-related investment effect than the firms in the light industry.

  • PDF

A Study on the Installation Effect Analysis and for Future Develop with Vertical Acceleration of Speed Hump (과속방지턱의 설치효과 분석 및 수직가속도에 의한 개발 연구)

  • 금기정
    • Journal of Korean Society of Transportation
    • /
    • v.14 no.4
    • /
    • pp.77-90
    • /
    • 1996
  • Recently existing the road traffic low is requlated by hump standard, which is established throuth the actual england TRRL(Transpodt and Road Research Laboratory) experiment. The determined standard has been utilized, however, wihtout the test on of our street and its drivers driving characteristics. Even with the utilization, the appropriate before and after management, is not constituted. In Spite of minimum speed limit, in many case, the utilization itself is questionalble rather than the purpose of restraining speed limit or reducing vehicle confacts. Along with hump consideration, social attention is focused due to series of personal law suit(traffic accident) field against the negligence of local organization management. Therefore counter measure of safe transportation facility is urgently required. With consideration of above background, the purpose of this research is to develop the hump that is appropriate with our transportation environment. This can be achieved thr ugh analysis of hump effectiveness, examination of drivers awamess, facilitation/management problems, and various problems in verticle acceleration.

  • PDF

INTERNATIONAL STANDARD PROBLEM 50: THE UNIVERSITY OF PISA CONTRIBUTION

  • Cherubini, Marco;Lazzerini, Davide;Giannotti, Walter;D'auria, Francesco
    • Nuclear Engineering and Technology
    • /
    • v.44 no.6
    • /
    • pp.587-596
    • /
    • 2012
  • The present paper deals with the participation of the University of Pisa in the last International Standard Problem (ISP) focused on system thermal hydraulic, which was led by the Korean Atomic Energy Research Institution (KAERI). The selected test was a Direct Vessel Injection (DVI) line break carried out at the ATLAS facility. University of Pisa participated, together with other eighteen institutions, in both blind and open phase of the analytical exercise pursuing its methodology for developing and qualifying a nodalization. Qualitative and quantitative analysis of the code results have been performed for both ISP-50 phases, the latter adopting the Fast Fourier Transfer Based Method (FFTBM). The experiment has been characterized by three-dimensional behavior in downcomer and core region. Even though an attempt to reproduce these phenomena, by developing a fictitious three-dimensional nodalization has been realized, the obtained results were generally acceptable but not fully satisfactory in replicating 3D behavior.

Study on Standardization Method of non-Standard AtoN Management and Operation System (비표준 항로표지 관리운영시스템 표준화 방안 연구)

  • Park, In-Hwan;Kim, Hyung-Lae
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.11a
    • /
    • pp.119-121
    • /
    • 2018
  • We intend to improve the navigation system integrated management system that is constructed and operated to meet the changes in marine traffic environment and prevent large-scale marine casualties and human casualties by applying the standard specification of integrated management system of marine traffic facilities in 2012. I t reuses the existing system resources and improves the operating software and standardizes the system installation to facilitate operation and maintenance.

  • PDF

A Study on the Technical Regulation of Brake System for Electrical Multiple Unit Safety (전동차 안전을 위한 제동장치의 기술기준에 관한 연구)

  • Lee, Woo-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1332-1334
    • /
    • 2003
  • Safety of breaking facility is very important in subway safety, especially in case of subway that many people used, breaking capability is connected directly with safety and capability of vehicle. Recently, direction of subway technical development is established as passenger's convenience and agreeableness. However, we are known importance of safety in subway through Dae-gu subway incendiary case. Subway accident not happen only fire, vehicle collisions or passenger's fall to the track can happen. In this case, safety standard of breaking facilities is very important. so this paper define safety of breaking facilities and take proper that standard.

  • PDF

Development of a Supporting Program for the Emergency Preparedness Plan (사고대비물질 취급자의 비상대응계획 작성 프로그램 연구)

  • Kim, Sung-Bum;Noh, Hye-Ran;Seok, Gwang-Seol;Park, Jae-Deuk
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.54-58
    • /
    • 2011
  • Emergency preparedness plan(EPP) is the systematic management of activities that involve a material degree of risk of loss or other damage to the surroundings(people, property and environment), and the boundary of accident recovery plan(ARP). The main purpose of the program is to provide a safety management system to each facility in order to enable to prevent accident and to control accident immediately. The EPP includes not only typical safety-related documentations such as material safety data sheet(MSDS), standard operation procedure(SOP), emergency response plan(ERP). EPP is established basis of the preliminary safety analysis involving risk identification, assessment and prevention plans. The program is also helpful for government or related agencies to control a number of accidents in small-scale companies in the whole country.

A Study on the Improvement of the Silver-Zone Selecting Method (노인보호구역 지정방법 개선에 관한 연구)

  • Kim, Jang-Wook;Hong, Joo-Hee;Kim, Jeong-Hyun;Lee, Soo-Beom
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.1
    • /
    • pp.78-88
    • /
    • 2009
  • As the silver population rapidly increased, it became more urgent to establish a scheme of the traffic safety for the old. As part of the scheme, a polity to apply 'designation of the silver zone' was legislated into law. However, the standard quoting 'the silver zone should be within 300m - radius of the relevant facility' was considered homogeneous and even limited to apply its original objective. This study was to introduce a new standard to select the silver zone reflecting the actual scale. Consequently, I hope that this study would be useful reference for further development and the approach in the research could be legislated into law for more efficient designation and operation of the silver zone.

Evaluation Standard of Cost-Effectiveness Analysis for Renew of Architectural Equipment in Public Building (공공건물 건축설비 갱신 계획시 비용-효율분석 평가기준에 관한 연구)

  • Jung, Soon-Sung
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.131-138
    • /
    • 2013
  • The purpose of this study is to suggest the evaluation standard of cost-effectiveness analysis for renew of architectural equipment in public building. Evaluation items of cost-effectiveness analysis for renew of architectural equipment in public building were used life cycle cost, energy consumption(ton of oil equivalent), green house gas emissions(ton of carbon dioxide) and maximum power demand. Life cycle cost is the process of making an economic assessment of an item, area, system, or facility by considering all significant costs of ownership over an economic life, expressed in terms of equivalent costs. The essence of life cycle costing is the analysis of equivalent costs of various alternative proposals. The social concern with green house gas and maximum power demand of architectural equipment field has been growing for the last several years.

Requirements Recommended for Nuclear Training Simulator Development based on IEEE 1516 (IEEE 1516 기반의 NTS 개발을 위한 권장요건)

  • 박근옥;임종태;한관호
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2003.11a
    • /
    • pp.133-138
    • /
    • 2003
  • The latest version of the HLA(High Level Architecture) standard developed by the US Department of Defense was established as an open and internal IEEE 1516 HLA standard in 2000. Commercial applications based on the IEEE 1516 have already developed in the non-defense industry. We participated in several development projects for NTS (Nuclear Training Simulator). Extensive modifications are necessary to make a new and/or upgraded NTS because the previously developed simulation softwares have not two desirable property: reusability and interoperability. We reviewed the IEEE 1516 specifications to develop NTS having the capability of reusability and interoperability. Our review activities were forced on application development process, supporting tools, and software structure of NTS. The primary goal of this review is to identify what are constraints or problems to be resolved when we apply IEEE 1516 to NTS development. In this paper we suggest several recommendations for NTS developers.

  • PDF