• 제목/요약/키워드: Standard Deviation

검색결과 5,422건 처리시간 0.041초

가중표준편차를 이용한 가변표본채취간격 $\bar{X}$ 관리도 (Variable Sampling Interval $\bar{X}$ Control Chart Using Weighted Standard Deviation Method)

  • 장영순
    • 한국경영과학회지
    • /
    • 제39권1호
    • /
    • pp.1-12
    • /
    • 2014
  • This article proposes a variable sampling interval (VSI) $\bar{X}$ control chart using weighted standard deviation (WSD) method for skewed populations. The WSD method decomposes the standard deviation of a quality characteristic into upper and lower deviations and adjusts control limits and warning limits of a control chart in accordance with the direction and degree of skewness. A control chart constant is derived for estimating the standard deviation of skewed distributions with the mean of sample standard deviations. The proposed chart is compared with the conventional VSI $\bar{X}$ control chart under some skewed distributions. Simulation study shows that the proposed WSD VSI chart can control the in-control average time to signal (ATS) as an adequate level better than the conventional VSI chart, and the proposed chart can detect a decrease in the process mean of a quality characteristic following a positively skewed distribution more quickly than the standard VSI chart.

적응적 필터링을 이용한 가우시안 잡음 예측 (Gaussian noise estimation using adaptive filtering)

  • 조범석;김영로
    • 디지털산업정보학회논문지
    • /
    • 제8권4호
    • /
    • pp.13-18
    • /
    • 2012
  • In this paper, we propose a noise estimation method for noise reduction. It is based on block and pixel-based noise estimation. We assume that an input image is contaminated by the additive white Gaussian noise. Thus, we use an adaptive Gaussian filter and estimate the amount of noise. It computes the standard deviation of each block and estimation is performed on pixel-based operation. The proposed algorithm divides an input image into blocks. This method calculates the standard deviation of each block and finds the minimum standard deviation block. The block in flat region shows well noise and filtering effects. Blocks which have similar standard deviation are selected as test blocks. These pixels are filtered by adaptive Gaussian filtering. Then, the amount of noise is calculated by the standard deviation of the differences between noisy and filtered blocks. Experimental results show that our proposed estimation method has better results than those by existing estimation methods.

그레이스케일 영상에서 표준 편차를 이용한 문자 분할 (Character Segmentation in a Grayscale Image using the Standard Deviation)

  • 정민철
    • 반도체디스플레이기술학회지
    • /
    • 제11권2호
    • /
    • pp.27-31
    • /
    • 2012
  • This paper proposes a new method of character segmentation in a grayscale image using the standard deviation. Firstly, the proposed method scans vertically the region of interest in an image in order to calculate a standard deviation for each scan line. Characters' standard deviations are much bigger than the background's. Therefore, it is possible to segment characters vertically using the differentiation of those two types of standard deviations. Secondly, the method scans each vertically segmented image horizontally at this time, and then segments each image similarly. The proposed method is implemented using C language in an embedded Linux system for a high-speed real-time image processing. Experiments were conducted by using credit card images. The results show that the proposed algorithm is quite successful for most credit cards. However, the method fails in some credit cards with strong background patterns.

Estimation of Unknown Parameters in Optimum Allocation

  • Park, Hyeonah;Park, Seunghwan;Na, Seongryong
    • Communications for Statistical Applications and Methods
    • /
    • 제20권2호
    • /
    • pp.137-145
    • /
    • 2013
  • The use of pooled standard deviation can reduce the efficiency loss in optimum allocation when strata standard deviations are estimated and several of them are equal. Also shown is that the pooled standard deviation is useful in optimum allocation under a multivariate setting. In addition to theoretical development, we provide the result of simulation study to support the theory.

生絲纖度檢査規定에 關한 考察 (A Distcussion on the Size Deviation Test of Raw Silk)

  • 최진협
    • 한국잠사곤충학회지
    • /
    • 제25권1호
    • /
    • pp.44-50
    • /
    • 1983
  • 現 生絲檢査規則 中 纖度偏差檢査項目에 관하여 檢討한 結果 약간의 矛盾點을 發見하였으므로 이를 지적하고 그 改善策을 設定하였다. 1. 現 纖度偏差檢査는 平均纖度가 50~69 denier에 標準偏差는 5.80以下, 4.61 以上일 때 A格으로 定하고 있으나 平均纖度 50 denier인 경우의 標準偏差 5.80과 平均纖度 69 denier인 경우의 標準差 5.80과는 同一分布라 할 수 없다. 2. C.V로 換算하여 볼 때 2A格의 C.V가 A格의 C.V보다 작아야 하는데 現 纖度檢査規定은 70denier 의 1A格의 C.V換算値는 9.00이며, 69denier의 A格의 C.V換算値는 8.41로서의 70denier 2A格이 69denier의 A格보다 變異의 分散이 크게 나타나는 矛盾點을 보였다. 3. 生絲의 纖度偏差檢査數値도 平均値가 다른 Sample끼리의 優劣을 나타내는 數値이며 이 數値로서 等級을 決定하기 때문에 標準偏差에 의하여 檢査할 것이 아니라 C. V에 의하여 檢査하여야 한다. 4. 33 denier 以上의 生絲에서 각 等級別로 볼 때 6A格에서 下位格으로 감에 따라 變異폭(變異係數)을 약간씩 크게 하였으나 곳에 따라 一貫性을 잃고 있으며 그리고 同一等級에서 纖度變化에 따른 變異係數數値의 變化도 같은 경향이므로 等級間 및 纖度間의 數値調整을 要한다. 5. 34 denier 以上에서는 標準偏差數 値를 代入하기 때문에 同一等級에서 平均纖度가 굵어짐에 따라 標準偏差數値를 크게 하였으나 C. V로 換算하여 보면 大同小異하므로 纖度變化에 따른 C. V數値를 달리 할 필요가 없다. 6. 以上의 1.2.3.4.5項의 矛盾點을 是正하기 위하여 是正하기 위하여 C.V에 의한 檢査方式을 導入하고 33denier 以上에서 각 纖度間과 각 等級間의 均衡을 바로 잡으며 또 34 denier 以上에서 각 等級間의 間隔을 바로 잡기 위하여 曲線回歸公式을 導入하여 調整할 必要가 있다. 7. 生絲檢査에서 纖度偏差檢査表를 다음과 같이 改正實施함이 보다 妥當하다.

  • PDF

시약 변경 시 모집단 분포 추이에 따른 결과 분석 (Result Analysis according to Population Distribution Trends when Reagents are Changed)

  • 박혜미;임수연;유선희;이선호
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.55-61
    • /
    • 2023
  • Purpose In this study, the monthly population distribution was calculated for statistical verification of 10 tests (CA19-9, CA15-3, testosterone, PTH, calcitonin, AFP, CEA, CA72-4, PSA, estradiol) with changed reagents, and the trend of change By comparing and analyzing the results, we want to verify the accuracy of the results and improve the reliability of the test. Materials and Methods From June 2021 to February 2023, for the 10 items in which the reagent was changed, the monthly percentage and standard deviation index before and after the reagent change were compared, respectively. At this time, the reference value was arbitrarily set for the comparison group in consideration of the reference value of the test item, and the groups were subdivided and compared, and the standard deviation index allowed range was -2.0 or more and 2.0 or less. Results For CA19-9, CA15-3, AFP, CEA, and calcitonin 5 test items, the change in monthly ratio in all test sections before and after the reagent change was kept constant. On the other hand, for CA72-4, PSA, testosterone, PTH, and estradiol items, the standard deviation index exceeded the acceptable standard after changing the reagent. CA72-4 test items showed an increasing trend in standard deviation index in the test section exceeding the reference value. In the case of the PSA test item, the maintenance ratio of 0.04 ng/mL was significantly decreased after changing the reagent. The testosterone test item had a standard deviation index of -2.5 in the test section exceeding 10.1 ng/mL after changing the reagent, and the standard deviation index of the PTH test item was out of the acceptable range in all test sections. It was confirmed that the estradiol test item showed an overall increase in the result value. Conclusion Through this study, the continuity and accuracy of the test results could be verified. It is considered that the stability of the test can be secured by analyzing the factors affecting the test result and solving the cause for the test item whose standard deviation index is out of the acceptable standard.

  • PDF

선삭가공시 절삭조건에 의한 Chip형태의 분류와 예측에 관한 연구 (A Study on the Classification and Prediction of the Chip Type under the Specified Cutting Conditions in Turning)

  • Sim, G.J.;Cheong, C.Y.;Seo, N.S.
    • 한국정밀공학회지
    • /
    • 제12권8호
    • /
    • pp.53-62
    • /
    • 1995
  • In recent years, the rapid development of the machine tool and tough insert has made metal removal rates increase, and automatic system without human supervision requires a higher degree reliability of machining process. Therefore the control of chips is one of the important topics which deserves much attention. The chip classification was made based upon standard deviation of the mean cutting force measured by a tool dynamometer. STS304was chosen as the workpiece which is known as the difficult-to-cut material and mainly saw-toothed chip produced, and the chip type according to the standard deviation of mean cutting force was classified into five categories in this experiment. Long continuous type chip which interrupts the normal cutting process, and damages the operator, tool and workpiece has low standard deviation value, while short broken type chip, which is favourable chip for disposal, has relatively large standard deviation value. In addition, we investigated the possibility that the chip type can be predicted analyzing the relationship between chip type and cutting condition by the trained neural network, and obtained favourable results by which the chip type can be predicted with cutting conditon before cutting process.

  • PDF

모평균과 모비율의 구간추정에서 표본표준편차의 일관된 사용에 대한 고찰 (The Consideration of Consistent Use of Sample Standard Deviation in the Confidence Interval Estimation of Population Mean and Population Ratio)

  • 박선용;윤형석
    • 대한수학교육학회지:수학교육학연구
    • /
    • 제24권3호
    • /
    • pp.375-385
    • /
    • 2014
  • 이 연구는 학교수학의 모평균과 모비율의 신뢰구간의 추정을 비교하면서 두 추정간에 일관성이 확보되고 있는지에 대해 고찰하였다. 이 결과를 토대로, 이 연구에서는 표본평균과 표본비율을 동일한 방식으로 취급하는 것, 모평균과 모비율의 신뢰구간의 예를 구성할 때 모표준편차 대신에 표본표준편차의 관측값을 대입하는 절차를 동일하게 적용하는 것, 표본비율 $\hat{P}$와 그에 대한 관측값 $\hat{p}$을 구별하는 것과 같은 일관성 확보 방안을 제안하였다.

  • PDF

정류방식에 따른 장치의 정확도와 출력 파형의 비교 (Comparison of Accuracy and Output Waveform of Devices According to Rectification Method)

  • 이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.603-610
    • /
    • 2018
  • This study examined the following: accuracy of the exposure conditions in the inverter device and three-phase device; output waveform over the exposure conditions; and average and standard deviation of the output waveform. After assessing whether the dose corresponding to the theoretical dose was presented, the following conclusions were obtained: 1. The accuracy of the tube voltage(kVp) and tube current(mA) exposure time(sec) was within the tolerable level prescribed in Korea's Safety Management Standards. In the error, Inverter device was large the tube voltage and exposure time, the three-phase device was large the tube current. 2. In terms of the output waveform of the exposure conditions and the average and standard deviation of the output waveform, the higher tube voltage and larger tube current resulted in greater standard deviation in pulsation. Moreover, the standard deviation of pulsation was shown to be greater in the inverter device than the three-phase device; there was also greater standard deviation in the inverter device considering the exposure time. 3. Regarding the exposure conditions over the output dose, all linearity showed the coefficient of variation which had an allowable limit of error within 0.05. Although the output dose ratio for the inverter device was 1.00~1.10 times no difference that of the three-phase device, there was almost no difference in dose ratio between the tube currents.

치매예방 프로그램 운영 및 효과검증 연구 (A Study on the Application of a Dementia Prevention Program and Its Effect Test)

  • 황옥남;윤숙례;황혜연;남기석
    • 재활간호학회지
    • /
    • 제5권2호
    • /
    • pp.156-165
    • /
    • 2002
  • The objective of this study was to apply a dementia prevention program to the subjects who were suspected of dementia and test its effect. This study was one group pretest-posttest design. The dementia prevention program was applied for 20 weeks to the 19 subjects who were suspected of dementia after a screen test among 638 subjects enrolled in 10 senior citizen's centers in G city. The scores of self-efficacy, cognition, quality of life were measured before and after the program. The data collected were analyzed using a SPSS (statistical analysis system) program, and frequencies, averages and standard deviations were obtained. The differences of the scores of the pretest and posttest were analyzed with Mann-Whitney test and sign test. The results were as follows: 1. After the program, the average score of self-efficacy was increased from 75.31 (standard deviation 11.99) to 84.26 (standard deviation 13.92). 2. There are no differences between the average scores of physical and psychological quality of life, however, the average score of social quality of life was slightly increased from 2.25 (standard deviation 0.40) to 2.53 (standard deviation 0.43), and the overall score of social quality of life was low. 3. The average score of cognition was significantly increased from 21.00 (standard deviation 2.60) to 24.58 (standard deviation 3.37), thus, it was found that the program was effective to improve the cognition level. 4. The score differences of self-efficacy, quality of life, cognition between the pretest and posttest were statistically significant. 5. The score differences of quality of life between the pretest and posttest were found to be dependent on marital status, exercise and regular checkup yes or no. In conclusion, the program was effective to prevent the subjects suspected of dementia from dementia.

  • PDF