• 제목/요약/키워드: Spray distance

검색결과 284건 처리시간 0.03초

Lead-Frame 에칭공정에서 몬테카를로 시뮬레이션을 이용한 에칭특성 예측 (The Prediction of Etching Characteristics Using Monte-Carlo Simulation in Etching Process of Lead-Frame)

  • 정흥철;최경민;김덕줄
    • 한국정밀공학회지
    • /
    • 제23권1호
    • /
    • pp.72-79
    • /
    • 2006
  • The objective of this work is to simulate the etching characteristics for the optimization on the etching process of Lead-Frame. The etching characteristics such as etching factor, etching uniformity were investigated under different the actual operating conditions. The correlation between the etching characteristics and the spray ones were analyzed to simulate the etching characteristics in the etching process. To improve the etching characteristics in the etching process, effects of the various operating conditions such as pressure, distance from nozzle tip, pipe pitch, and feed speed should be understood in detail. The spray characteristics obtained by experiment using PDA system were simulated by the Monte-Carlo simulation. The etching process model was coded by Java language. It was found that the spray characteristics were correlated with the etching ones and simulation results generally agreed well with the measured results of etching characteristics in the etching process of Lead-Frame. The optimal operating parameters were successfully found under variable conditions.

재활용 APT를 이용한 WO3 제조와 WC-Co 의 용사코팅 (WO3 Fabrication and Thermal Spray Coating of WC-Co using Recycled Ammonium Paratungstate (APT))

  • 정준기;김성진;온진호;문흥수;피재환;하태권;박상엽
    • 소성∙가공
    • /
    • 제24권4호
    • /
    • pp.287-292
    • /
    • 2015
  • The possibility of chemical precipitation for recycled ammonium paratungstate (APT) was studied. WO3 particles were synthesized by chemical precipitation method using a 1:2 weight ratio of APT:DI-water. At the 500℃ sintering temperature, the X-ray diffraction results showed that APT completely decomposed to WO3. For the granulated powder WC-Co, vacuum heat treatment at proper temperatures increases tap density and flow-ability. Hardness of the WC-Co thermal spray coating layer was measured in the range HV 831~1266. Spray conditions for the best characteristic values were an oxygen flow rate=1500 scfh, a fuel flow rate = 5.25gph and a gun distance = 320mm.

초고압수를 이용한 노면표시 자동제거 장비개발을 위한 제어시스템 및 노면최적조건에 대한 연구 (DEVELOPMENT OF A CONTROL SYSTEM FOR AN AUTOMATIC ROAD SIGN REMOVING EQUIPMENT USING HIGH PRESSURE WATER-JET)

  • 권순욱;김균태;한재구
    • 한국건설관리학회논문집
    • /
    • 제5권4호
    • /
    • pp.139-146
    • /
    • 2004
  • Resent removal work for road signs has been labor intensive and required times since it has been done manually using shaving type equipment. While traditional process is conducting, there are traffic jams caused by the passing control, and happened unexpected accidents to workers working at dangerous road circumstance. Besides, in current shaving method, there are high potentialities on the air pollution as well as the explosive accident occurred by using a propane gas. So, as an alternative, we have studied to develop the automatic erasing equipment made up with a high pressure water-jet system and automatic control system, mobile system; Wate-rjet system consists of an intensifier and nozzles to give a high pressure and spray on the sign, and automatic control system is composed of one axis robot using a hydraulic servo actuator controlled by a lever, And as a mobile system, a truck plays an important role for the transport of equipment and the forward movement in a removal process. In this paper, we have analyzed the characteristics of road signs and have investigated current erasing methods in the field. And we have organized and designed automatic erasing equipment, and we have made a basic experiment to find out the optimal spray condition as like the spray distance, spray angle and injection pressure.

Effect of the Raw Material and Coating Process Conditions on the Densification of 8 wt% Y2O3-ZrO2 Thermal Barrier Coating by Atmospheric Plasma Spray

  • Oh, Yoon-Suk;Kim, Seong-Won;Lee, Sung-Min;Kim, Hyung-Tae;Kim, Min-Sik;Moon, Heung-Soo
    • 한국세라믹학회지
    • /
    • 제53권6호
    • /
    • pp.628-634
    • /
    • 2016
  • The 8 wt% yttria($Y_2O_3$) stabilized zirconia ($ZrO_2$), 8YSZ, a typical thermal barrier coating (TBC) for turbine systems, was fabricated under different starting powder conditions and coating parameters by atmospheric plasma spray (APS) coating process. Four different starting powders were prepared by conventional spray dry method with different additive and process parameter conditions. As a result, large- and small-size spherical-type particles and Donut-type particles were obtained. Dense structure of 8YSZ coating was produced when small size spherical-type or Donut-type particles were used. On the other hand, 8YSZ coating with a porous structure was formed from large-size spherical-type particles. Furthermore, a segmented coating structure with vertical cracks was observed after post heat treatment on the surface of dense structured coating by argon plasma flame at an appropriate gun distance and power condition.

붐방제기 살포장치의 설계요인 구명을 위한 실험적 연구(II) -노즐의 분무유형 및 벼의 피복특성- (Design Factors of Boom Sprayer(II) -Spray Droplet Size and Coverage Characteristics on Rice Plants-)

  • 정창주;김학진;이중용;최영수;최중섭
    • Journal of Biosystems Engineering
    • /
    • 제20권4호
    • /
    • pp.313-322
    • /
    • 1995
  • This study was conducted to find the design factors of spraying device of the boom sprayer for low volume application. Specific objectives of this study were 1) to select proper nozzles for broadcast spraying and row crop spraying by the nozzle spray characterisic experiment, and 2) to investigate the coverage characteristic of rice plant at the row crop spraying. The results of this study are summarized as follows. (1) From the tested results on the droplet diameter spectrum and spray pattern the standard flat-fan nozzle and drift guard nozzle were judged as appropriate for the broadcasting. Even flat-fan nozzle showed similar span values to standard flat-fan nozzles and drift guard nozzle : however, the nozzles were found to be inappropriate for broadcasting because of their spray pattern. Hollow cone nozzle showed relatively small span values and uniform spray pattern. (2) For the upper and lower sides of the rice plants, coverage rates of even flat-fan nozzles and hollow cone nozzles were maximum at the second row, but decreased rapidly after the third row. For the middle side of the rice plants, coverage rates of them were maximum at the first row, but decreased rapidly. When one nozzle was tested, C.V. values were in the range of 90~160% and 60~160% on entire heights of rice plant for even flat-fan nozzles and hollow cone nozzles respectively. C.V. values at other parts were poor. Spray coverage rate at the middle part was improved by overlapping the nozzles whereas there was little difference on the upper and lower part of rice plants. (3) For spraying lower part of rice plant between rows, even flat-fan nozzles and hollow cone nozzle were judged as appropriate, but in order to ensure the uniform coverage, distance between nozzles, recommended to be less than 90cm.

  • PDF

전자·반도체용 스프레이 세정제에 대한 분사력 및 세정성 평가 (Evaluation of Cleanliness and Jet Forces by Spray-Type Cleaning Agent for Electronic and Semiconductor Equipment)

  • 허효정;정용안;노경호
    • Korean Chemical Engineering Research
    • /
    • 제48권3호
    • /
    • pp.401-404
    • /
    • 2010
  • 본 연구에서는 PCB의 먼지 제거용 세정제로 사용되는 스프레이형 세정제를 선정하였다. 전자 반도체 부품의 세정에서 분무 세정의 원리를 적용시킨 제품의 분사력을 평가하기 위해 기판(IPC-A-36)을 사용하여 세정제를 분사하여 분사시간에 따라 그 이동거리를 비교하였다. 철가루와 먼지를 오염물, 기판(IPC-A-36)을 시편으로 하여 일반시험 평가법의 방법 중 가장 보편적으로 쓰이는 중량법으로 오염물에 따른 세정성능을 측정하여 비교하였다. 기판의 이동거리는 분사 시간이 늘어남에 따라 증가하였다. 1회 세정 시(3초간 분사) 먼지와 철가루는 오염물의 양이 증가함에 따라 세정효율이 감소하였고 특히 먼지 오염물은 매우 급격한 세정효율의 감소를 보였다.

초음파에너지 조사 W/O type 유화연료의 제반특성에 관한 연구(I) - 안정성 및 분무특성을 중심으로 - (A Study on the Various Characteristics of Ultrasonic-Energy-Added W/O Type Emulsified Fuel ( I ) - attaching importance to stability and spray characteristics -)

  • 김용철;송용식;류정인
    • 한국분무공학회지
    • /
    • 제9권3호
    • /
    • pp.22-28
    • /
    • 2004
  • This study is concerned about the characteristics of ultrasonic-energy-added W/O type emulsified fuel. The distilled water was mixed with diesel oil by using ultrasonic energy fuel feeding system and then the SMD of sprayed droplets was measured to find out atomization characteristics of emulsified fuel by using the Malvern 2600 system. The capacitance value was measured to verify stability of the same specimen by using the digital LCR meter, EDC1630 additionally. The main results are as follows; 1) The more measuring distance increases between one hole nozzle tip and analyser bearm, the more SMD increases. 2) The more water content increases, the more capacitance value increases depending on the time. Main Parameters of the study are the amount of water content $0{\sim}30%$ by 5% in emulsified fuel, and the measurement distance, $20{\sim}140mm$ by 10mm or 20mm between nozzle tip and analyser beam.

  • PDF

액체 로켓용 충돌형 Triplet 인젝터의 미립화 특성에 관한 연구 (A study on spray characteristics of the triplet impinging stream type injector for liquid rocket)

  • 박성영;김선진;박승운;김유
    • 대한기계학회논문집B
    • /
    • 제20권3호
    • /
    • pp.1005-1014
    • /
    • 1996
  • An experimental investigation has been carried out to examine the influence of injector design variables and operating conditions on the resultant drop size for triplet impinging streams injectors. The variables studied in this investigation are pressure drop, impinging angle, orifice length to diameter ratio, and impinging point distance. Droplet-size data are obtained using water as the propellant simulant by Malvern Particle Analyzer System. Drop size decreases with increasing impinging angle and pressure drop while other injector parameters remain constant at the same point. But it is found that there is no noticeable droplet-size change which results from change in orifice length to diameter ratio or impinging point distance within the investigated range.

비전도성 액체의 전기수력학적 분무에 관한 실험적 연구 (An Experimental Study on Electrohydrodynamic Atomization of Non-Conducting Liquid)

  • 이기준;박종승;이상용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1322-1327
    • /
    • 2004
  • In the present work, a series of experiments have been performed on electro-hydrodynamic atomization of non-conducting liquid using a charge injection type nozzle. Effects of liquid flow rate, input voltage, and distance between the needle and the ground electrode (nozzle-embedded metal plate) have been examined. For fixed electrode distances, total and spray currents increase with increase of liquid flow rate and input voltage. When the distance between the needle and the ground electrode becomes closer, total, leakage and spray current increase, but the onset voltage for dielectric breakdown decreases. When the electric field strength of the liquid jet exceeds that for the air breakdown, a portion of the electric charges in the liquid jet is dissipated into the ambient air, and the charge density shows a limiting value. Atomization quality can be improved by increasing the flow rate because the higher charge density is achieved with the larger liquid velocity in addition to the enhanced aerodynamic effect.

  • PDF

비전도성 액체의 전기수력학적 미립화를 위한 전하 주입 특성에 관한 실험적 연구 (An Experimental Study on Charge Injection to Non-Conducting Liquid for Electrohydrodynamic Atomization)

  • 이기준;박종승;이상용
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1376-1383
    • /
    • 2004
  • In the present work, a series of experiments have been performed on electro-hydrodynamic atomization of non-conducting liquid using a charge injection type nozzle. Effects of liquid flow rate, input voltage, and distance between the needle and the ground electrode (nozzle-embedded metal plate) have been examined. For fixed electrode distances, total and spray currents increase with the increase of liquid flow rate and input voltage. When the distance between the needle tip and the ground electrode becomes closer, the total, leakage and spray currents increase, while the onset voltage for the dielectric breakdown decreases. When the electric field strength of the liquid jet exceeds that for the air breakdown, a portion of the electric charges in the liquid jet is dissipated into the ambient air, and the charge density shows a limiting value. Atomization quality can be improved by increasing the liquid flow rate due to the higher charge density and the enhanced aerodynamic effect.