Environmental Functional Soundproof Wall (친환경 기능성 방음벽)

  • Kim, Ji Sung;Lee, Woo Mi;Kim, Il Ho;Kim, Kwang Soo
    • International Journal of Highway Engineering
    • /
    • v.15 no.5
    • /
    • pp.65-73
    • /
    • 2013
  • PURPOSES : This study is to suggest future development direction and application of environmental noise barriers as multi-functional soundproof wall. METHODS : Based on the literature review, case study and patent search, research and patent trend were investigated. Patent search was conducted by Patent searching tools, 'Focust'. RESULTS : As environmental noise barriers, Vegetative soundproof wall, photovoltaic soundproof wall, and air-pollution reduction soundproof wall were investigated. First of all, In Korea, Vegetative soundproof wall is being developed mostly as soundproof wall that has vegetation foundation inside, to meet the domestic condition with 23 patent applications. Second, Photovoltaic soundproof wall is being developed mainly with efficiency of photovoltaic system rather than soundproofing. And it is limited to one generation solar cell technology, although Solar cell technology is developing at a rapid pace. On the other hand, for reducing air-pollutant by soundproof wall, a variety of methods are being suggested (filtration, adsorption, and photocatalytic oxidation), and one of them, adsorption are applied for developing air pollution reduction soundproof wall in Korea. CONCLUSIONS: The above soundproof wall is not simple structure, but road facility applied fusion technique. Therefore, as one system, it is difficult to harmonize due to various considerations for design factor. However, if it's possible that a benefits of one system apply to another system, Synergy effect may be created. In the foreseeable future, soundproof wall may be considered as a road system using fusion technique rather than just functional facility. Therefore, substantial studies for applying multi-functional soundproof wall on the road are needed for the future.

Structure Design System of Soundproofing Wall Using Green Stone (조경블록(그린스톤)을 이용한 방음벽 구조설계시스템)

  • Han, Jung-Geun;Han, Seung-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.3 no.4
    • /
    • pp.1-10
    • /
    • 2000
  • This study aims at the new design system development of landscape architecture structures, as soundproof wall using reinforced soil block. This structures, that is new soundproof wall system, have to be maintained stability on acting critical wind load, which is combined exist soundproof wall system and soundproof wall system using environmental green stone block. To the harmony of this system, the post block, so-called landscape block or cast block, is manufactured. It's possible to stand of the post bearing system combined with post-pile and post block. Through the comparison with a serious code for the acting wind load on the soundproof wall, the reasonable wind load could be calculated. Also, the mechanical stability on the green stone block was checked by the Lab. tests based on the UBC (Uniformed Building Code). Because the critical height of soundproof wall system using green stone generally was restricted, the new system demands to combination of the exist system and the new system. For the stability analysis of them, the utility program, SAP2000, was used. And, a semi-auto program on the design system of the new soundproof wall using green stone was developed, which can be easily use because of the simplification.

  • PDF

Evaluation of the Functions and Reliability of an Eco-Friendly Vegetated Soundproof Wall for Climate Benefits

  • Jong-Sung Kim;Young-Hyoo Kwon;Yong-Jo Jung
    • Journal of Forest and Environmental Science
    • /
    • v.40 no.2
    • /
    • pp.141-150
    • /
    • 2024
  • This study aims to develop and commercialize a soundproof wall capable of planting at the urban ecological. The vegetative soundproof wall developed in the study showed highly superb structural test results for sound absorption coefficients and met the quality standards in the sound-absorbing performance test. Its structure is systemized to supply water to soils and plant roots inside the planting basis with rainwater running down the inclined planes near the planting basis in the front of the vegetation panel. It allows for sporadic water supply for about 30 days of drought. The test results show that the plants continued favorable growth and development in leaves, stems, and roots, making the vegetative soundproof plate a product capable of reacting to climate environment changes.

Estimation Method of the Design Wind Load of Soundproof Wall Using GIS (GIS를 이용한 방음벽의 설계풍하중 산정방법)

  • Lee, Dong-Ho;Choi, Se-Hyu
    • Spatial Information Research
    • /
    • v.23 no.5
    • /
    • pp.75-85
    • /
    • 2015
  • Recently deformed or destroyed of soundproof wall by local winds and typhoon has increased. This research proposed the estimation method of the design wind load of soundproof wall using spatial information analysis based on 1:5,000 digital map and performed comparative analysis with actual application cases. According to the result of quantitative evaluation using GIS, the surface roughness in the downtown area packed with buildings was III and the surface roughness in the suburban district with a relatively small number of buildings was II and the surface roughness in the district packed with open areas and typical farmhouses was I. This shows that the wind load of the soundproof walls reflecting the actual surface conditions was estimated. If the quantitative GIS analysis presented in this study is applied to wind-resistant design of soundproof walls, it is supposed that this will be helpful in more rational wind-resistant design by remedying the existing problem in which the wind load varies depending on designer's subjectivity.

Noise Protection Roof: Partial Opening Effect for Noise Reduction (철도용 터널형 방음벽 개발연구: 설계 방향)

  • Kim, Tae-Min;Kim, Jeung-Tae
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.6
    • /
    • pp.522-532
    • /
    • 2015
  • In the present study, a tunnel type soundproof wall with partial opening is proposed to reduce the environmental noise caused by railway vehicles traveling on bridges, which affects residents of high-rise apartment buildings; the study also attempts to minimize load due to wind and the weight of the wall. Applying the principles of computational fluid dynamics and structural mechanics, and the ray tracing method, a reduction in noise as well as of the overall weight of the soundproof walls is estimated. Analysis results show that the proposed soundproof wall with a partial opening weighs less, while reducing the wind loading by up to 30%. To prevent direct propagation of sound through openings in the wall, an acoustic louver, which is a type of silencer, could be considered for the opening. In order to achieve a similar noise effect with existing insulation material, the fluid flow and the insulation effect of the acoustic louver are analyzed. As the considered opening is in the range of 30~40% of the total length of the soundproof wall, the noise effect and wind load are reduced by 10dB and 25% respectively. Consequently, opening some part of tunnel type soundproof walls and installing louvers on the wall openings can have the effects of weight-reduction and reduced wind load. If a partial opening is applied with proper sound material application, a gain of an additional 5~10dB of noise reduction can be achieved.

Development of the Soundproof Enclosure for Power Transformers (전력용 변압기 차음실 개발)

  • Kweon, Doug-Jin;Koo, Kyo-Sun;Lee, Wook-Ryun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.107-114
    • /
    • 2009
  • Because of the increase of power demand and expansion of downtown, it is necessary to install the power transformers at the substation in the residential area. But the public complaints have increased due to the noise of the power transformers in the substation. A soundproof wall has been employed to the power transformers in the outdoor substations and a soundproof door, a soundproof shutter and soundproof equipment for wind-path has been employed to power transformers in the indoor substations in order to isolate sound propagation from the noise of the power transformers. But the noise reduction results of these methods are not satisfied. In this study, a soundproof enclosure is developed to effectively isolate sound propagation from the noise of the power transformers. The performance of the sound attenuation of the developed soundproof enclosure is verified in a 154[kV] transformer. As a result, 15[dB] sound attenuation in 120[Hz] component is achieved by applying the developed soundproof enclosure to a 154[kV] transformer.

An Empirical Study of Soundproof wall with Reduced Wind Load (풍하중 저감형 방음판의 실증 연구)

  • Choi, Jin-Gyu;Lee, Chan-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.272-278
    • /
    • 2018
  • Traffic volume has been greatly increasing due to urban development and the improvement of living standards, and many complaints are being raised due to the increasing road noise. As a countermeasure against these problems, highly soundproof walls are installed on the sides of roads. However, the ability to bear wind loads is a major design requirement for soundproof walls, which contributes to the exponential increases in construction costs and restricts the height of the walls. The aim of this study is to improve the performance of soundproof walls and to dramatically reduce wind loads while maintaining excellent price competitiveness. Based on Helmholz's resonator theory, a new concept is proposed for a ventilation-type soundproofing plate that can pass through a fluid like air and reduce noise. A full-scale metal soundproofing plate was produced to satisfy the quality standards of highways by conducting a sound-pressure transmission-loss test, wind tunnel test, and material quality test. To verify the reliability, the wall was manufactured and installed, and the sound insulation effect was examined by measuring the noise over time. In the future, ventilated soundproof walls on roads could create a pleasant living environment due to the high noise-insulation effect.

A Study on Outdoor Acoustic Noise for HVDC Converter Station (HVDC 변환소의 옥외소음 분석)

  • Lee, Seong-Doo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.91-99
    • /
    • 2010
  • HVDC converter station consists of a number of equipment such as converter transformer, ac filter, thyristor valve and so on. They can be acoustic noise sources. In this paper, we analyzed the simulation results of the outdoor acoustic noise for HVDC converter station. It shows that maximum noise level in boundary of HVDC converter station exceeds regulation value. The main factors in generating maximum noise level are ac filter and converter transformer. Then we applied some soundproof countermeasures in HVDC converter station. Shielding wall is enough to reduce transformer noise level but not enough to reduce ac filter noise level. In case of ac filter, soundproof building is effective in satisfying noise level regulation in boundary of HVDC converter station. In addition, we also studied effects of season, soundproof woods, ground.

Analysis of Acoustic Noise Characteristics of Jindo-Cheju HVDC (진도-제주 HVDC 변환설비 소음특성 분석)

  • Kim, Jae-Han;Kim, Chan-Ki;Lee, Seong-Doo;Kim, Jin-Young
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.574-576
    • /
    • 2010
  • HVDC converter station consists of a number of noise sources such as converter transformer, ac filter, cooling system and so on. In this paper, we analyzed the simulation results of the outdoor acoustic noise characteristics for HVDC converter station. It shows that maximum noise level in boundary of HVDC converter station exceeds regulation value. The main factors in generating maximum noise level are ac filter and converter transformer. Then we applied some soundproof countermeasure in HVDC converter station. Shielding wall is enough to reduce transformer noise level but not enough to reduce ac filter noise level. In case of ac filter, soundproof building is effective in satisfying noise level regulation in boundary of HVDC converter station. In addition, we also studied effects of season, soundproof woods, ground.

  • PDF