• Title/Summary/Keyword: Solid environmental samples

Search Result 243, Processing Time 0.022 seconds

Analysis of Trace Levels of Halonitromethanes (HNM) in Water using Headspace-SPME and GC-ECD (Headspace-SPME와 GC-ECD를 이용한 수중의 미량 Halonitromethane (HNM)류 분석)

  • Kang, So-Won;Son, Hee-Jong;Seo, Chang-Dong;Kim, Kyung-A;Choi, Jin-Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.5
    • /
    • pp.293-302
    • /
    • 2015
  • Halonitromethanes (HNMs) are one of the most toxic groups of disinfection by-products. Recently, various studies have been fulfilled. An automated headspace-solid phase microextraction (SPME) gas chromatography/electron capture detector (GC-ECD) technique was developed for routine analysis of 9 HNMs in water samples. The optimization of the method is discussed. The limits of detection (LOD) and limits of quantification (LOQ) range from 90 ng/L to 260 ng/L and from 270 ng/L to 840 ng/L for 9 HNMs, respectively. Matrix effects in tap water and sea water were investigated and it was shown that the method is suitable for the analysis of trace levels of HNMs, in a wide range of waters. The method developed in the present study has the advantage of being rapid, simple and sensitive.

Dietary Intake and Venous Blood Concentration of Polycyclic Aromatic Hydrocarbons in Low-level Exposure (다환방향족탄화수소류의 음식물을 통한 섭취량과 혈중농도)

  • Moon, Chan-Seok
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.5
    • /
    • pp.386-392
    • /
    • 2012
  • Objectives: This study aims to evaluate the blood concentrations and dietary intake for 24-hour food duplicate of low level polycyclic aromatic hydrocarbons (PAHs). Design: The geometric means of the blood concentrations and dietary intake of 16 PAHs in college student candidates were simply compared with instrumental detection. Methods: The concentrations of 16 PAHs in venous blood and 24-hour food duplicates were analyzed with head-space solid phase microextraction (HS-SPME) of gas chromatography-mass spectrometry. Results: Naphthalene, acenaphthylene, pyrene, benz(a)anthracene, chrysene, and acenaphthene among the 16 analyzed PAHs were simultaneously detected both in venous blood and 24-hour food duplicate samples. Conclusion: The main exposure source of the six PAHs is thought to be oral intake from food through low level non-occupational exposure.

RESEARCH PAPERS : REMOVAL EFFICIENCY OF THE POLLUTANTS BY MULTILAYERED METAL TREATED CARBON FILTER

  • Oh, Won-Chun;Lee, Ho-Jin;Bae, Jang-Soon
    • Environmental Engineering Research
    • /
    • v.9 no.5
    • /
    • pp.193-200
    • /
    • 2004
  • A study of the treatment of piggery wastes using a multilayered metal-activated carbon system followed by carbon bed filtration was carried out at bench scale. From the physicochemical properties obtained from samples treated with aqueous solutions containing metallic ions such as Ag$^+$, Cu$^{2+}$, Na$^{-}$, K$^+$ and Mn$^{2+}$, main inspections are subjected to isothem shape, pore distribution with micropore, SEM and EDX. Multilayered metal-activated carbons were contacted to waste water to inwestigate the simultaneous catalytic effect for the COD, BOD, T-N and T-P removal. From these removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed, satisfactory removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed was derermined by the properties of this material for trapping, catalytic effect and adsorption of organic solid particles.

Air-coupled ultrasonic tomography of solids: 2 Application to concrete elements

  • Hall, Kerry S.;Popovics, John S.
    • Smart Structures and Systems
    • /
    • v.17 no.1
    • /
    • pp.31-43
    • /
    • 2016
  • Applications of ultrasonic tomography to concrete structures have been reported for many years. However, practical and effective application of this tool for nondestructive assessment of internal concrete condition is hampered by time consuming transducer coupling that limits the amount of ultrasonic data that can be collected. This research aims to deploy recent developments in air-coupled ultrasonic measurements of solids, described in Part 1 of this paper set, to concrete in order to image internal inclusions. Ultrasonic signals are collected from concrete samples using a fully air-coupled (contactless) test configuration. These air coupled data are compared to those collected using partial semi-contact and full-contact test configurations. Two samples are considered: a 150 mm diameter cylinder with an internal circular void and a prism with $300mm{\times}300mm$ square cross-section that contains internal damaged regions and embedded reinforcement. The heterogeneous nature of concrete material structure complicates the application and interpretation of ultrasonic measurements and imaging. Volumetric inclusions within the concrete specimens are identified in the constructed velocity tomograms, but wave scattering at internal interfaces of the concrete disrupts the images. This disruption reduces defect detection accuracy as compared with tomograms built up of data collected from homogeneous solid samples (PVC) that are described in Part 1 of this paper set. Semi-contact measurements provide some improvement in accuracy through higher signal-to-noise ratio while still allowing for reasonably rapid data collection.

Hydrogeochemical characteristics of urban groundwater in Seoul

  • Lee, Ju-Hee;Yun, Seong-Taek;Kwon, Jang-Soon;Kim, Dong-Seung;Park, Seong-Sook
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.472-472
    • /
    • 2004
  • Numerous studies on urban groundwater have been carried out in many other countries. Urban groundwater shows a unique hydrologic system because of complex urban characteristics such as road pavement, sewers and public water supply systems. These urban facilities may change the characteristics of groundwater recharge but contaminate its quality as well. There have been several researches on urban groundwater in Seoul. Seoul has been industrialized very rapidly so that the city has large population. The recent population in Seoul amounts to more than ten millions, corresponding to a very high density of about 17, 000 people/km$^2$. Therefore, many factors affect the groundwater quality and quantity in Seoul. Nowadays, groundwater in Seoul is being extracted for construction, industrial use, and drinking and so on. There are 15, 714 wells in Seoul and its annual usage is 41, 425, 977m$^3$(in 2001). Therefore, systematic studies are needed to properly manage and use the groundwater in Seoul. The purposes of this study in progress are to identify geochemical characteristics of groundwater in Seoul and to determine the extent of groundwater contamination and its relationship with urban characteristics. For this study, groundwater was sampled from more than 400 preexisting wells that were randomly selected throughout the Seoul area. For all samples, major cations together with Si, Al, Fe, Pb, Hg For 200 samples among them, TCE, PCE, BTEX were also analyzed by GC. Our study shows that groundwater types of Seoul are distributed broadly from Ca-HCO$_3$ type to Ca-Cl+NO$_3$ type. The latter type indicates anthropogenic contamination. Among cations, Ca is generally high in most samples. In some samples, Na and K are dominant. The dominant anions change widely from HCO$_3$ to Cl+NO$_3$. The anion composition is considered to effectively indicate the contribution of distinct anthropogenic sources. In addition, major ions are positively proportional to total dissolved solid (TDS) except K and NO$_3$. Thus, we consider that TDS may be used as an effective indicator of the extent of pollution. However, the increase of TDS may result from increased water-rock interaction. To determine the extent of groundwater contamination, it is needed to figure out the baseline water quality in Seoul. Furthermore, detailed geochemical studies are required to find out pollution sources and their corresponding hydrochemical parameters.

  • PDF

Recycling Energy from Mixture of Sewage Sludge and Petroleum Coke Waste

  • Lee, Ki-Hwan;Lee, Tae-Ho;Kim, Jong-In;Park, Byung-Bin;Choi, Suk-Nam;Han, Ki-Suk
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_2
    • /
    • pp.73-77
    • /
    • 2001
  • The disposal of sewage sludge using landfills and ocean dumping is no longer a viable option due to land scarcity and increasingly stringent environmental control regulations. As such, various efforts have been made to develop new sewage sludge recycling technologies. This work investigates the fundamental physical and chemical characteristics of rural type sewage sludge from Chungnam province in South Korea. The average moisture content, ignition loss, elementary analysis, and average heating value of the sewage sludge samples were examined. The average moisture content of the dewatered sludge was about 80%, while the organic matter was about 50% of the total solid sludge weight. The average heating value of a sewage sludge and petroleum coke waste mixture(1:1 weight ratio) was about 5,000 ㎉/kg, thereby indicating a high potential for energy recycling.

  • PDF

Estogenic and Dioxin-like Activity of Influent and Effluent of the Industrial Wastewater Treatment Plant

  • Oh, Seung-Min;Kim, Gi-Sur;Kim, Soung-Ho;Kim, Yun-Hee;Chung, Kyu-Hyuck
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2002.10a
    • /
    • pp.166-166
    • /
    • 2002
  • The response of environmental pollutants can be detected bioanalytically focusing on the source and matrices of concern. Cell culture bioassays are rapid and inexpensive, and thus have great potential for determination of environmental pollution. We have examined the estrogenic and dioxin-like activites of industrial wastewater using E-screen assay and EROD microbioassay. Influent and effluent wastewater were collected from four different industrial wastewater treatment plants, such as cosmetics, paints, textile producing and metal coating plant, and extracted using solid-phase extraction with Oasis@HLB plus cartridge. Pollutants adsorbed to the cartridge were eluted with MTBE. MCF-7 cells were treated with extracts showed various estrogenic potential. The textile wastewater showed strong estrogenic activity and the others showed weak estrogenic activity, No effect was observed in the wastewater from paints producing plant. All extracts showed CYPIA inducing effects, indicating these samples contain dioxin-like chemicals. Bioanalytical results of effluents compared with influents could give us information about the incomplete wastewater treatment and biological potency caused by pollutants. [Supported by a Grant from the Korea Science and Engineering Foundation]

  • PDF

Phosphorus removal by lime-natural mineral dissolved solutions

  • Joohyun, Kim;Sunho, Yoon;Jueun, Jung;Sungjun, Bae
    • Membrane and Water Treatment
    • /
    • v.14 no.1
    • /
    • pp.27-33
    • /
    • 2023
  • In previous studies, solely ferric (Fe3+) and calcium (Ca2+) ions were commonly used for removal of PO4-P (considered as T-P in this study) in wastewater via chemical precipitation. Herein, the removal of total phosphorus (T-P) in wastewater was performed using various mineral and lime dissolved solutions. The dissolution kinetics of different minerals (feldspar, olivine, elvan, illite, sericite, and zeolite) and lime was compared and used their solutions for T-P removal of real wastewater. The highest T-P removal (almost 90%) was obtained by the lime dissolved solution and followed by zeolite, illite, feldspar, and others. We observed a significant co-relationship (R of 0.96) between the amount of initial Ca2+ and T-P removal. This was induced by formation of hydroxyapatite-like mineral via Ca-P precipitation reaction at high pH solution. Furthermore, additional removal of suspended solid (SS) and chemical oxygen demand (COD) was achieved by only lime dissolved solution. Finally, the lime-feldspar dissolved solutions were prepared at different ratios (10-50%), which showed a successive T-P removal up to two times by samples of 40 and 50%.

Mercury Pollution in the Onsan Coastal Area (온산연안해역의 수은오염에 관한 연구)

  • PARK Chung-Kil;PYEN Jong-Ryool;YOU Sun-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.22 no.5
    • /
    • pp.233-240
    • /
    • 1989
  • The concentration of mecury was measured in the seawater, sediment, Mytilus edulis and suspended solid in the coastal area of Onsan. Samples were collected at spring and neap tide in the period from October 9 to November 2, 1984. The range and mean of mecury concentration in the seawater are $0.08\~0.73{\mu}g/\iota\;and\;0.19{\mu}g/\iota$. The range and mean of mecury concentration in the suspended solid was $0.70\~17.0{\mu}g/g$ TSS and $4.6{\mu}g/g$ TSS respectively. The average concentration of mecury in Mytilus edulis was 0.10mg/kg which was higher than that of the reference area, Chung Mu. The mean value of concentration factor of mercury in wet base is 500 in Mytilus edulis. The average concentration of mecury in sediment was 0.15mg/kg.

  • PDF

Simultaneous Determination of Ultra-Trace Pesticides and Synthetic Materials in Surface Water by LC-ESI-MS/MS (하천수에서 LC-ESI-MS/MS에 의한 극미량 농약류 및 합성원료의 동시분석법)

  • Hong, Seon-Haw;Lee, Jun-Bae;Lee, Soo-Hyung;Cho, Young-Hwan;Shin, Ho-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.59 no.3
    • /
    • pp.225-232
    • /
    • 2015
  • A liquid chromatography-electrospray ionization-tandem mass spectrometry method (LC-ESI-MS/MS) was used for determining seven pesticides (2,4-dichlorophenoxyacetic acid, methomyl, aldicarb, 2-methyl- 4-chlorophenoxy- acetic acid, molinate, carbaryl and carbofuran) and two synthetic materials (quinoline and bisphenol-A) in surface water. The analytes were extracted using solid-phase extraction (SPE). The eluate was concentrated by nitrogen gas. 100 microliters of 30% (v/v) methanol aqueous solution were used to dissolve the residue and an aliquot of the reconstituted solution was directly injected into LC-ESI-MS/MS after the filtration using 0.2 μm polytetrafluoroethylene (PTFE) syringe filter. Under the established condition, the calibration curves of the analytes were linear with correlation coefficients of above 0.997. The quantification limit was 0.002~0.011 μg/L and the relative standard deviations were less than 16.4%. In addition, accuracy was in the range of 84~107% and the recoveries were values between 56.2 and 98.6%. In this study, the developed method was applied to the analysis of real surface water samples.