• 제목/요약/키워드: Solid Insulated Switchgear

검색결과 13건 처리시간 0.036초

25.8kV 고체절연스위치기어 개발 (Development of 25.8kV class solid insulated switchgear)

  • 이종혁;마지훈;유련;이재걸;원성연;이석원;김영근;길경석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.226-228
    • /
    • 2008
  • In recent years, the companies of electric power equipment for MV and HV classes trend to develop the eco-friendly insulated(solid, eco-gas, air etc.) switchgear which replaces existent SF6 gas insulated switchgear due to environmental problems such as global warming and so on. This paper makes reference to the newly developed Solid Insulated Switchgear (SIS) which uses the eco-friendly material such as epoxy for insulation. The insulation of the solid insulated switchgear (SIS) is composed of an epoxy, vacuum and air. The solid insulated switchgear (SIS) is a slate of the art product. The advantages of SIS are advanced reliability, economical efficiency, safety, maintenance free, reduction of installation area and the protection of environment. The solid insulated switchgear (SIS) is FE Analyzed such as electromagnetic, mechanical, thermal and fluid in order to find the optimal design. Thens SIS has been verified by international standard test. (IEC 62271 - 100 and so on.) As a result of this, the solid insulated switchgear (SIS) has been estimated as an alternative for eco-friendly MV class switchgear.

  • PDF

IT Enabled 친환경 고체절연 Switchgear (Eco-friendly Solid Insulated Switchgear for IT Enabled)

  • 이종혁;마지훈;유련;이재걸;탁성준;박정남;이석원;안희일;김영근;신영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.241-243
    • /
    • 2005
  • This paper describes development of intelligent solid insulated switchgear for next generation distribution line. Nowadays, for switchgear, increased to substitute eco-friendly environment and smart ability. In relation to a project to development of intelligent solid insulated switchgear, a comparison of insulation for substitution insulation medium, to show a composition of intelligent solid Insulated switchgear and valuation on characteristics for each of module.

  • PDF

25.8kV급 친환경 고체절연차단기(Solid Insulated Switchgear)에 대한 기계적 신뢰성(수명) 평가 (Mechanical Reliability(Life-Time) Estimation for 25.8kV Eco Solid Insulated Switchgear)

  • 이도훈;이석원;박석원;김영근;이종호
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.202-205
    • /
    • 2010
  • In this paper, mechanical reliability(Life-time) estimation method for 25.8kV SIS(Solid Insulated Switchgear) has been studied. Recently enacted KEPCO's standard includes clause that have to submit a warrantable reliability data for life-time(over B10 25 years) of an epoxy-solid insulating material. Accordingly, this research was carried out on the ALT(Accelerated Life Test) and Life-Estimation method for SIS's insulating material. Mechanical life-time estimation for SIS's insulating material is to verify reliability for tensile creep & fatigue stress, which is the major mechanical stress of SIS. This study proved that SIS's reliability for mechanical stress and established that confidence for estimation results in further verification test.

25.8kV 고체절연차단기(Solid Insulated Switchgear)에 대한 기계적 신뢰성(수명) 평가 (Mechanical Reliability(Life-time) Estimation for 25.8kV Solid Insulated Switchgear)

  • 이도훈;강원종;이석원;신철호;김영근;이규철;이승엽;김호근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2007_2008
    • /
    • 2009
  • 본 논문은 $SF_6$ 가스졀연차단기를 대체할 고체절연차단기(Solid Insulated Switchgear:SIS)의 기계적 신뢰성 평가에 대한 연구 결과이다. 최근 제정된 "25.8kV 가스 및 고체절연 친환경 개폐장치" 한전 구매규격에는 "Epoxy 고체절연물에 대한 기계적 신뢰성(수명)이 25년 이상"임을 보증할 수 있는 신뢰성 데이터를 제출해야 한다는 조항이 포함되어있다. 이에 개발된 고제절연차단기의 Epoxy 고체절연물에 대한 기계적 신뢰성(수명)이 25년 이상임을 보증할 수 있는 신뢰성 시험과 분석 기법에 대한 연구가 진행되었다.

  • PDF

가스절연 개폐장치 투입저항의 동특성 해석 (Dynamic Characteristics Analysis of Closing Resistors of Gas Insulated Switchgear)

  • 조해용;이성호;임성삼;이기정;김민우
    • 한국정밀공학회지
    • /
    • 제22권11호
    • /
    • pp.104-110
    • /
    • 2005
  • GIS(Gas Insulated Switchgear) is used in electric power system, to insure non conductivity, breaking capacity and operating reliability. The commercial dynamic analysis code COSMOS MOTION and 3-D modeling program SOLID WORKS were used to simulate dynamic analysis of the closing resistors of the GIS in this paper. To reduce chatter vibration of closing resistors, the motion of moving and fixed parts of closing resistors were simulated by varying the spring constant, the damping coefficient and the mass of moving and fixed parts. The simulated results were compared with experimental results. As a result, chatter vibration of closing resistors of the GIS could be reduced by using the results. These data can be used to determine the spring constant, the damping coefficient and mass of a moving part to reduce chatter vibration when the next model is developed.

Dynamic Analysis on the Closing Resistors of Gas Insulated Switchgear

  • Cho Hae-Yong;Lee Sung-Ho;Lim Sung-Sam
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1607-1613
    • /
    • 2006
  • GIS (Gas Insulated Switchgear) is used in electric power system to insure non conductivity, breaking capacity and operating reliability. In the present study, dynamic analysis on the closing resistors of the GIS has bees carried out by the commercial dynamic analysis code COSMOS MOTION and 3-D modeling program SOLID WORKS. In order to find the minimum value of chatter vibration of closing resistors, the motion of moving and fixed resistor parts of closing resistors were simulated by varying the spring constant, the damping coefficient and the mass of moving and fixed resistor parts. The simulated results were compared with experimental results. The application of the results could reduce chatter vibration of closing resistors of the GIS. These data are also useful on the development of future model GIS with minimum chatter vibration for the determinations of the spring constant, the damping coefficient and mass of a moving part.

25.8kV $SF_6$가스절연 스위치기어(GIS)를 대체한 친환경 고체절연 스위치기어(SIS) 개발 (Development of the replaced Eco-friendly SIS with GIS for 25.8kV class)

  • 마지훈;정맹뢰;유련;원성연;이석원;김영근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1219_1220
    • /
    • 2009
  • In recent years, the companies of electric power equipment for MV, HV class trend to develop that the eco-friendly insulated(solid, eco-gas, air etc.) switchgear replace with existent SF6 gas insulated switchgear by environmental problems such as global warming and soon. This paper introduces the Solid Insulated Switchgear(SIS) which is the epoxy of eco-friendly insulation material. The characteristic of SIS to introduce in this paper is as following. 1) Eco-friendly. (SF6 gas free) 2) The structure of flexible system. (Expansion) 3) The optimum design. (The Analysis of electrical & mechanical) 4) An Interface treatment between epoxy and insert. (Molding technology) This paper described about some technology for development of SIS.

  • PDF

적층된 에폭시 고체유전체와 도전성 파티클에 대한 Dry-Air의 연면방전특성 (Surface Discharge Characteristics in Dry-Air on Laminated Epoxy Solid Dielectrics and Conductive Particle)

  • 임동영;전종철;배성우;이광식;박원주
    • 조명전기설비학회논문지
    • /
    • 제30권2호
    • /
    • pp.93-101
    • /
    • 2016
  • This paper presents the surface discharge characteristics in Dry-Air on laminated epoxy solid dielectrics and conductive particles in order to provide the valuable information for the insulation design of eco- friendly gas insulated switchgear. To improve insulation performance, the three types of the laminated epoxy solid dielectrics were proposed, and it was revealed that their surface discharge characteristics were similar to the bakelite dielectrics of same-laminated types. From the surface discharge characteristics of dry air, it was demonstrated that the effect of conductive particles on surface discharge voltage was dominant when there are this particles at the shortest electrode gap and that the degradation of insulation performance on the conductive particles was evident in epoxy than teflon. These phenomena were interpreted in terms of particle-triggered discharge mechanism and electric field of triple junction, respectively.

가스절연 개폐장치의 고체 스페이서에 대한 유전율 경사기능성 재료의 영향 (Effect of Permittivity Functionally Graded Materials on Solid Spacer in Gas Insulated Switchgear)

  • 주흥진;김봉석;황휘동;박정호;최승길;고광철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1364-1365
    • /
    • 2008
  • 가스 절연 개폐장치(Gas Insulated Switchgear)의 고체 스페이서에 다양한 유전율 분포를 가진 경사기능성 재료(Functionally Graded Material)를 적용할 때, 전계의 완화를 예상할 수 있다. FGM 스페이서는 전계의 집중을 완화시킬 수 있고, 내부의 전계를 더 균일하게 분포시킬 수 있다. 본 연구에서는 유한요소법을 이용하여 상용 GIS의 FGM 스페이서에서 전계의 세기를 계산하였다. 계산 결과를 통해 스페이서의 유전율이 빠르게 변화하는 경우, 더 효율적으로 최대전계를 감소시켰고, 스페이서 내부의 전계를 균일하게 하였다. 결과적으로 FGM 스페이서는 단일 유전율을 가진 스페이서에 비해 절연 성능을 향상시킬 수 있다.

  • PDF

초고압 절연 스페이서의 자동가압 겔화 성형 공정을 위한 경화 보압의 최적화 (Optimization of Curing Pressure for Automatic Pressure Gelation Molding Process of Ultra High Voltage Insulating Spacers )

  • 이찬용;조한구;이재형
    • 한국전기전자재료학회논문지
    • /
    • 제37권1호
    • /
    • pp.56-62
    • /
    • 2024
  • By introducing curing kinetics and chemo-rheology for the epoxy resin formulation for ultra-high voltage gas insulated switchgear (GIS) Insulating Spacers, a study was conducted to simulate the curing behavior, flow and warpage analysis for optimization of the molding process in automatic pressure gelation. The curing rate equation and chemo-rheology equation were set as fixed values for various factors and other physical property values, and the APG molding process conditions were entered into the Moldflow software to perform optimization numerical simulations of the three-phase insulating spacer. Changes in curing shrinkage according to pack pressure were observed under the optimized process conditions. As a result, it was confirmed that the residence time in the solid state was shortened due to the lowest curing reaction when the curing holding pressure was 3 bar, and the occurrence of deformation due to internal residual stress was minimized.