• 제목/요약/키워드: Solar PV System

검색결과 668건 처리시간 0.021초

세계 태양광발전산업 현황 (Status of Photovoltaics in the world)

  • 강기환;유권종;박경은;김현일
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.86-91
    • /
    • 2008
  • Amid the booming research on new and renewable energy, the photovoltaic(PV) industry has been growing around the PV advanced countries such as Japan, Germany, Europe and USA. In recent years, China became a strong performer in the world PV market share, increasing solar cell production rapidly. Both world solar cell and module production and installation rose steadily in 2007 like recent bumper years. In 2007, the PV industry produced 4.28GW and the installations reached a record high of 2.83GW, representing growth of 60percent over the previous year.

  • PDF

소형 태양광 발전시스템 상용화를 위한 프로그램 방식의 태양위치추적기 개발 (A Development of the Solar Position Tracker on the Program Method for the Small Typed Stand-alone PV System Commercialization)

  • 이양규;강신영;김광헌
    • 전력전자학회논문지
    • /
    • 제8권3호
    • /
    • pp.260-265
    • /
    • 2003
  • 태양의 고도와 방위각에 따라 태양광 발전 시스템의 에너지량이 차이가 많이 난다. 본 연구는 소규모 독립형 시스템인 가로등에 맞는 경제적인 추적장치 개발에 관한 것이다. 위치추적시스템은 프로그램을 사용한 방식으로서 시스템을 기존 유사 시스템에 비해 저가화를 실현하였다. 개발된 태양 위치 추적 시스템을 가로등에 적용하여 고정식과 추적식의 에너지량을 일정 기간 동안 실측 비교한 결과 평균 86%의 효율개선 효과를 보았다.

PSCAD/EMTDC를 이용한 계통연계형 태양광발전시스템의 모델링 (PSCAD/EMTDC Based Modeling of a Grid-Connected Photovoltaic Generation System)

  • 김슬기;전진흥;김응상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.204-207
    • /
    • 2004
  • The paper proposes a simulation model of grid-connected photovoltaic generation system (PV system) using on PSCAD/EMTDC, a reliable power system and apparatus transient analysis program. A equivalent circuit model of a solar cell is used for modeling solar array. A series of parameters required for array modeling are deduced from general specification data of a solar module. A PWM voltage source inverter (VSI) model is presented and current control scheme is implemented for VSI control. A maximum power point tracking (MPPT) technique is applied for controlling the PV system. Simulation case study provides V-I and V-P characteristics of solar array and PV system control performance for irradiation changes.

  • PDF

태양광 추적장치 연구 (Research of the PV Tracking System)

  • 서명환;김윤식;홍진우;이희준;박상구;김선형
    • 한국산학기술학회논문지
    • /
    • 제11권8호
    • /
    • pp.2951-2957
    • /
    • 2010
  • 태양광 산업에 있어서 PV추적 발전장치의 개발은 고정식 발전장치에 비하여 효율적이다. 추적식 발전장치는 단위면적당 태양의 일사량을 유지하고, 태양 전지의 효율을 최대화 한다. 따라서 정확하면서 저렴한 태양 위치 추적장치의 경제성을 개선하는 것과 투자 가격을 내리는 것이 중요하다. 본 연구는 태양위치를 감지하는데 센서를 사용하지 않고 천문학과 수학을 이용하여 1분($0.016^{\circ}$)이내의 태양의 위치 알고리즘에 관한 것이다. 이 논문에 제안된 알고리즘은 장치의 비용을 내리고 발전효율도 높여준다. 지금까지 알고리즘을 적용한 결과를 고려하면, 최대오차는 30초 ($0.008^{\circ}$)를 보인다. 그리고 이 알고리즘으로 적용한 태양광 발전시스템은 고정식 대비 평균 23W(약18%)의 이득을 보였다.

환기 유무에 따른 CIGS BIPV 커튼월 유닛의 성능 비교 분석 (Comparison of Performance Analysis of the Ventilated and Non-­ventilated CIGS BIPV Units)

  • 김상명;김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제37권2호
    • /
    • pp.47-57
    • /
    • 2017
  • CIGS thin film solar cells are technically suitable for BIPV applications than regularly used crystalline silicon solar cells. Particularly, CIGS PV has lower temperature coefficient than crystalline silicon PV, thus decrease in power generation is lowered in CIGS PV. Moreover, CIGS PV can decrease shading loss when applied to the BIPV system, and the total annual power generation is higher than crystalline silicon. However, there are few studies on the installation factors affecting the performance of BIPV system with CIGS module. In this study, BIPV curtain wall unit with CIGS PV module was designed. To prevent increase of temperature of CIGS PV module by solar radiation, ventilation was considered at the backside of the unit. The thermal specification and electrical performance of CIGS PV of the ventilated unit was analyzed experimentally. Non-ventilated unit was also investigated and compared with ventilated unit. The results showed that the average CIGS temperature of the ventilated curtain wall unit was $6.8^{\circ}C$ lower than non-ventilated type and the efficiency and power generation performance of ventilated CIGS PV on average was, respectively, about 6% and 5.8% higher than the non-ventilated type.

고정식 집속형 PV모듈 복합패널의 BIPV적용성 검토 (A Study on the Application of Fixed-concentrated PV Module Hybrid Panel for BIPV)

  • 서유진;허창수
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.77-83
    • /
    • 2005
  • The verified thermal efficiency, thermal capacity confirmed the effects of the cooling system. Therefore, it is useful for preventing the PV cell temperature rising when solar radiation accumulates in summer. When adopting a hybrid panel for the BIPV system, the affected areas include the vertical outside walls facing the south, southeast, and southwest on the curtain walls excluding windows. The standards on replace aluminum panel which were the popular exterior material were investigated, Designing practice made sure that it could be manufactured in various sizes, and confirmed the most proper method to install a hybrid panel in the BIPV system.

경량 태양광발전 블라인드 개발 및 제어조건에 따른 음영분석 (Developing the Light-weight PV Blind System and the Shading Analysis by the Control Conditions)

  • 정유근
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.83-88
    • /
    • 2015
  • This study aims to develope the light-weight PV blinds with windows and to investigate the shading analysis by the control conditions. For the study, the polycarbonate characteristics and coating methods are analyzed and the PV blind design for a small office is suggested. Also, the mock-up model of a suggesting system was made. The field tests were controled based on a solar altitude under clear sky conditions. As results, it is necessary to use a polycarbonate instead of a tempered glass for a light-weight PV. The shading effects of blind systems are high in slat angle $30^{\circ}$ and low in $0^{\circ}$. Also, the shading ratio is more affected by solar latitude than solar altitude. The shading change rate is relevantly constant on the solar altitude.

중국 티베트지역의 100kWp급 태양광발전시스템 실증연구 (Installation and Performance Evaluation of 100kWp PV System in Tibet)

  • 김석기;윤재호;이정철;안세진;윤경훈;송진수
    • 신재생에너지
    • /
    • 제2권2호
    • /
    • pp.16-22
    • /
    • 2006
  • This paper present the performance evaluation of PV systems installed at Tibet area of China in order to identity the key factors that determines system operation at a severe climate conditions and promote the cooperation of PV technology between Korea and China. The installed systems consist of 100kW on-grid connected PV systems, BOS(balance of systems), data acquisition and transmission equipments. The Korea side supplied the solar cell, BOS like as inverter, control box and monitoring system. And the Chinese side assembled solar module, constructed site and built control house. It has been shown that the average radiation per monthly from Tibet is 1.5 times larger than that from Mokpo. Also, radiation time from Tibet is 2hour higher than that from Korea.

  • PDF

이산치 신호를 이용한 PV시스템의 제어특성 (The Control Characteristics of PV System Using Discrete Data Signal)

  • 김동휘;백형래
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.93-96
    • /
    • 1999
  • Solar cell generate DC power from sunlight whose power is different at any instance according to condition of variables : insolation and temperature. In order to improve the system utility factor and efficiency of energy conversion, it is desirable to operate the PV system at maximum power point of solar cell under different condition. In this paper, Boost chopper is controlled it output voltage with a new discrete control algorithm for MPPT. PWM signal of DC-DC converter are generated with a 89C51 microcontroller. Switching frequency of DC-DC converter is set at 10KHz. Simulation and experimental results show that the PV system studied in this paper is always operated at maximum power point under different maximum power point of solar cells having stabilized output voltage waveform with relatively small ripple component

  • PDF

500kW급 태양광시험장 구축을 위한 최적설계에 관한연구 (A Study on optimal design for installion of 500kWp PV system testing ground)

  • 김의환;장주연;임희천
    • 한국태양에너지학회 논문집
    • /
    • 제30권4호
    • /
    • pp.43-48
    • /
    • 2010
  • The performance of photovoltaic systems could be affected by various factors including installing conditions of modules, and their own efficiencies of solar cells and inverters. The installing conditions of a photovoltaic system including array types, tilting angles, azimuth, locations, quantities of sunshine, optimum angles of inclination and separated distance are analyzed using the SolarPro & Minitep SW simulation program, inorder to set up the installing conditions for improving system performance. The result from the simulation of the 500kWp PV system of Kochang with optimal installing conditions compared with normal conditions shows that the capacity factor has been increased from 11.02% to 12.06%.