• Title/Summary/Keyword: Soil Thickness

Search Result 576, Processing Time 0.029 seconds

The Experiment on The Efficiency of Heating System for Improving Farm Houses (농촌주택 개량을 위한 난방 효율 시험)

  • 이회만;최예환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.2
    • /
    • pp.3395-3409
    • /
    • 1974
  • The purpose of this study is to test and compare the efficiency of heating-system for materials and construction of the wall, ceiling and window in soil brick house, cement house and boulder house respectively, in order to construct ideal farm houses in rural area. The results obtained were as follows: 1. In heat conservation due to construction of walls the thermal efficiency of cement brick house was equivalent to 66.3% of that of soil brick house, and boulder house 60.3% 2. In the case of ceiling, the thermal efficiency of paper ceiling was amounted to 84.2% of that of the composite ceiling (thickness 6mm veneer+thickness. l0m chaffs), and the common ceiling putting on soil above the ceiling, 76% of the composite while the efficiency of the ceiling putting on chaffs above them was 15.8% higher than that of the paper. 3. In the case of improving the window, the double type was 12% higher than. the efficiency of single type. 4. The warming velocity of conventional house was slower but the velocity of radiation was quicker than that of experimental one. It was thought to be due to unscietific constructions of the room bottom, fire inlet and chimney, 5. The temperature gradient line was not dependad upon the amount of throwing into fuel in the rural farm house. 6. It was concluded that the final thermal efficiency of the conventional farm house was 10.6% lower than that of experimental farm house.

  • PDF

Decrease in the Thickness of Capillary Fringe Induced by Surface Active Chemicals in the Groundwater (계면활성물질의 지하수적용에 의한 모관수대 두께의 감소)

  • Kim, Heonki;Shin, Seungyup;Yang, Haewon
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.6
    • /
    • pp.52-58
    • /
    • 2012
  • Capillary fringe divides the groundwater and the vadose zone controlling the diffusive mass transfer of contaminants and gases. The thickness of capillary fringe is of great importance for the rate of contaminant mass transfer across the capillary fringe. Application of surface active chemicals including surfactants and alcohol-based products into the subsurface environment changes the surface tension of the aqueous phase, which in turn, affects the thickness of the capillary fringe. In this study, a bench-scale model was used to assess the quantitative relationship between the surface tension and the thickness of the capillary fringe. An anionic surfactant (Sodium dodecylbenzene sulfonate, SDBS) and an aqueous solution of ethanol were used to control the surface tension of the groundwater. It was found that the thickness of the capillary fringe is directly proportional to the surface tension. The air entry pressures measured by the Tempe Pressure Cell at different surface tensions using SDBS (200 mg/L) and ethanol (20%, v/v) solutions were in good agreement with the thicknesses of the capillary fringe measured by the model. A simple method to correct the conventional Brooks-Corey model for estimating the air entry pressure was also presented.

Minimum Thickness of Temporary Steel Plate to Prevent Pile Driver Overturning (항타기 전도예방을 위한 임시 철판의 두께에 관한 연구)

  • Bang, Daepyung;Park, Jongyil;Kee, Junghun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.11
    • /
    • pp.5-10
    • /
    • 2020
  • Although pile driver overturning accidents at construction site are not frequent, most leads to serious disasters. The main cause of accidents is uneven settlement of the ground. To prevent this, related guidelines such as KOSHA-C-101-2014, KOSH-A-GUIDE-71-2012, Occupational Safety and Health Standards, and NCS stipulate the installation of steel plates over ground. However, since the required steel plate thickness considering the self-weight of pile drivers and the underlying ground condition is not quantitatively presented, it is randomly applied in the field. In this study, the required minimum steel plate thickness was analyzed based on a numerical analysis (Plaxis 2D). Settlements and soil failure were calculated according to the different type of soils (sand, clay), load distribution and steel plate thickness (10mm, 20mm, 30mm, 40mm). Under all conditions, 10mm steel plate causes soil collapse. From thickness 20mm, the ground uneven subsidence is within 2° of the allowable leader angle.

Feasibility of Diffusive Gradients in Thin Films for Monitoring Heavy Metals in Groundwater (지하수 내 중금속 모니터링을 위한 diffusive gradients in thin films의 적용 가능성 평가)

  • Kyu-Young Shim;Kwangjin Park;Seungwoo Lee;Jongmin Choi;Subin Choi;Jinsung An;Kyoungphile Nam
    • Journal of Soil and Groundwater Environment
    • /
    • v.29 no.4
    • /
    • pp.12-20
    • /
    • 2024
  • Diffusive gradients in thin films (DGT) are passive sampling devices used to determine the time-weighted average concentrations (TWAC) of contaminants. To ensure accurate performance in groundwater, it is crucial to identify environmental characteristics and maintain optimal operational conditions. This study examined the deployment time required to reach effective capacity, the thickness of the diffusive boundary layer (DBL) under stagnant water conditions, and biofilm formation on the DGT surface using groundwater samples. When using DGT with Chelex gel (A=3.14 cm2), the effective capacity was 0.7 ㎍ for Cd and 250 ㎍ for Zn, with a deployment time of 24 h. Lower Cd accumulation was due to the competition effect of coexisting ions. The DBL thickness under stagnant conditions was 0.074 cm, 93% of the diffusion gel's thickness (0.08 cm). Neglecting DBL thickness in TWAC calculations led to a 79% decrease in the determined concentration. No biofouling was observed during the 28-d DGT deployment in groundwater. In conclusion, it is essential to consider the appropriate deployment time, DBL thickness, and biofilm formation to ensure accurate DGT performance in determining contaminant levels in groundwater.

Comparison of NERICA and Asian rice among traits relevant to drought resistance in the field and the effects of compost

  • Fujii, Michihiko
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.335-335
    • /
    • 2017
  • Recently NERICA (New Rice for Africa) was developed by a crossing of African rice (Oryza glaberrima Steud.) and Asian rice (Oryza sativa L.) in West Africa, and is considered to be drought resistant, but drought resistance of NERICA and differences between Asian rice are not clarified enough. In this research, NERICA (four cultivars and two lines), Asian rice (three cultivars and sativa parent of NERICA) and African rice (glaberrima parent of NERICA) were cultivated in the field in Shizuoka University under drought and traits of each cultivar and line relevant to drought resistance, stomatal conductance by porometer, soil water content of individual depths by TDR method, SPAD values by SPAD meter and leaf thickness by micrometer, were measured and compared with dry matter production and yield. Effects of compost were also compared among sativa parent, one NERICA cultivar and two NERICA lines. Glaberrima parent showed highest top dry weight. One NERICA line, one drought resistant Asian rice cultivar and sativa parent, showed higher top dry weight and yield (ear weight) than other Asian rice cultivars and NERICA cultivars and line tested. Compost tended to increase top dry weight and yield in one of NERICA line and sativa parent. But in one NERICA cultivar and line, top dry weight and yield were not increased. In one of Asian rice, one of NERICA line and sativa parent that showed high top dry weight and yield, stomatal conductance was high. On the contrary the glaberrima parent and in other NERICA cultivars and line it was low. In sativa parent compost increased stomatal conductance but in NERICA cultivar and lines it was not. Among cultivars and lines that showed high top dry weight and yield sativa parent and one of NERICA line SPAD value and leaf thickness were high but in one of Asian rice and glaberrima parent they were low. Cultivar and line differences in yield and top dry weight among Asian rice and NERICA were significantly correlated with those in stomatal conductance ($r=0.778^{**}$ and $r=0.654^*$, respectively) and those in leaf thickness ($r=0.600^*$ and $r=0.640^*$, respectively). In Asian rice cultivars average soil water content was significantly correlated with yield ($r=0.886^*$) but in NERICA cultivars and lines it was not significant correlated (r= -0.256). Cultivar and line differences in leaf thickness were significantly correlated with SPAD value ($r=0.773^{**}$). In Asian rice cultivars it was significantly correlated ($r=0.962^{**}$), but in NERICA cultivars and lines it was not significantly correlated (r=0.559). Asian rice cultivars tended to consume soil water to increase yield but in NERICA cultivars and lines the tendency was not clear. Correlation between SPAD value and leaf thickness was different between Asian rice and NERICA cultivars and lines, and in Asian rice cultivars it was significantly correlated but in NERICA cultivars and lines it was not significant. Importance of maintaining high stomatal conductance by high leaf thickness was clarified.

  • PDF

Utility of Hydrophilic Polymer for Green Technology Development in Green Roofs Using Rainwater (빗물활용 옥상녹화 녹색기술 개발을 위한 친수성 중합체의 효용성)

  • Ju, Jin-Hee;Yang, Ji;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.21 no.12
    • /
    • pp.1469-1476
    • /
    • 2012
  • Hydrophilic polymer is suitable as soil conditioners for green roofs that use rainwater, due to promotion of water retention capacity as well as enhancement of the water absorbing capacity. The objective of the present study was to investigate the effects of different levels of hydrophilic polymer concentrations (0, 0.1, 0.2, 0.4, 0.8% w/w) on the water holding capacity and growth response of 6 species in soils amended with hydrophilic polymer in 5 cm of soil thickness on green roofs. The results showed that the water holding capacity of the amended soil improved with increasing amount of applied polymer. The application of 0.8% w/w of the polymer increased the soil moisture by 87% compared to the control, and decreased slowly in green roofs during an arid period. The growth of Sedum spurium 'Dragon's blood' and Lampranthus spectabilis increased significantly and had greater than 60% relative coverage with higher hydrophilic polymer concentrations. However, Juniperus chinensis var. sargentii and Euonymus fortunei var. radicans had no significant differences upon change of hydrophilic polymer concentrations. In Carex kujuzana and Carex morrowii 'Aurea variegata', growth decreased with increase of hydrophilic polymer concentrations. 30 days after planting, Juniperus chinensis var. sargentii, Euonymus fortunei var. radicans, Carex kujuzana, and Carex morrowii 'Aurea variegata' died back due to lowest soil thickness (5 cm), but Sedum spurium 'Dragon's blood' and Lampranthus spectabilis had greater than 90% survival.

Impact of soft and stiff soil interlayers on the pile group dynamic response under lateral harmonic load

  • Masoud Oulapour;Sam Esfandiari;Mohammad M. Olapour
    • Geomechanics and Engineering
    • /
    • v.33 no.6
    • /
    • pp.583-596
    • /
    • 2023
  • The interlayers, either softer or stiffer than the surrounding layers, are usually overlooked during field investigation due to the small thickness. They may be neglected through the analysis process for simplicity. However, they may significantly affect the dynamic behavior of the soil-foundation system. In this study, a series of 3D finite-element Direct-solution steady-state harmonic analyses were carried out using ABAQUS/CAE software to investigate the impacts of interlayers on the dynamic response of a cast in place pile group subjected to horizontal harmonic load. The experimental data of a 3×2 pile group testing was used to verify the numerical modeling. The effects of thickness, depth, and shear modulus of the interlayers on the dynamic response of the pile group are investigated. The simulations were conducted on both stiff and soft soils. It was found that the soft interlayers affect the frequency-amplitude curve of the system only in frequencies higher than 70% of the resonant frequency of the base soil. While, the effect of stiff interlayer in soft base soil started at frequency of 35% of the resonant frequency of the base soil. Also, it was observed that a shallow stiff interlayer increased the resonant amplitude by 11%, while a deep one only increased the resonant frequency by 7%. Moreover, a shallow soft interlayer increased the resonant frequency by 20% in soft base soils, whereas, it had an effect as low as 6% on resonant amplitude. Also, the results showed that deep soft interlayers increased the resonant amplitude by 17 to 20% in both soft and stiff base soils due to a reduction in lateral support of the piles. In the cases of deep thick, soft interlayers, the resonant frequency reduced significantly, i.e., 16 to 20%. It was found that the stiff interlayers were most effective on the amplitude and frequency of the pile group.

Seral Changes in Environmental Factors and Recovery of Soil Fertility during Abandoned Field Succession after Shifting Cultivation (회전 후 묵밭의 식생 천이 진행에 따른 환경요인의 변화와 토양 비옥도의 회복)

  • Lee, Kyu Song;Joon-Ho Kim
    • The Korean Journal of Ecology
    • /
    • v.18 no.2
    • /
    • pp.243-253
    • /
    • 1995
  • Seral changes in environmental factors and recovery of soil fertility during abandoned field succession after shifting cultivation were investigated in eastern Kangwon-Do, Korea. Relative light intensity of herb and shrub layer decreased gradually until 50 years and increased slightly thereafter. Amount of litter and nutrients derived from it were depicted as a parabola form showing the gradual increment during the first 50 years and slight decrease thereafter. Organic matter, pH value, total-N and Mg of soil were plotted as an early depletion-mid pinnacle form showing the extrems depletion during the first 10 years, abrupt increase in about 20 or 50 years and gradual decrease thereafter. Ca, Al, Mn and Na of soil were depicted as a pinnacle form showing the peak in about 20 or 50 years. Thickness and field capacity of soil increased gradually, but K and total-P did not show any tendency as succession proceeded. The soil fertility, overall capacity of soil nutrients and water for plant growth, was plotted as the early depletion-mid pinnacle form.

  • PDF

A Study on Permeability of Stratified soil in the Close State Under Existence of Stagnant Water. (담수상태에 있어서 성층토양의 물의 침투에 관한 연구)

  • 조경용
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.3
    • /
    • pp.3477-3491
    • /
    • 1974
  • Following are the results of the study on the property of falling permeation of stratified soil in the close state under existence of stagnant water on a soil layer. 1. When on the stratified soil a least permeating layer was put on the soil layer the load Pressure was present owing to appearance of saturation close state driving decrease of the pressure in the lower layer, on the other hand when the least permeating layer was placed under the layer the lower least permeating layer pressure was decreased. 2. In the case of least permeating layer the variation of current gradient according to the respective level after treating the layer was enormous and due to usal storage phenomena for the Kl layer which was coarse that was trifle. 3. The permeability of the respective layer of stratified soil in the close state died not always coincide with that of single layer. 4. Generally Zunker's equation of average permeability was valid but actually calculated permeating velocity after treating the layer of stratified soil was seriously differ from the measured value owing to the variation of current gradient, especially when the pressure head at the layer boundany was discontinuous the validity of the equation of average permeability was seemed to be doubtful. 5. The permeating velocity of stratified soil was regulated by the least permeating layer, i.e. it is thought to be rational to estimate the value by calculating the current gradient with its proper permeability, pressure headon the layer and its thickness.

  • PDF