• Title/Summary/Keyword: Smoke Evacuation

Search Result 212, Processing Time 0.024 seconds

A Study on the Performance Variation Depending on Using Period of Ionization Smoke Detector (이온화식연기감지기의 사용기간 경과에 따른 성능변화 연구)

  • Kim, Shi-Kuk;Baek, Won-Don;Ok, Kyung-Jea;Lee, Chun-Ha
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.175-179
    • /
    • 2008
  • This paper studied on the performance variation depending on using period of ionization smoke detector. In korea, there were a lot of loss of lives and property because of fire. In many cases, an alarm equipment didn't operate though it was set up, so it causes the failure of early evacuation and fire suppression. Accordingly, an experiment on the change of ionization smoke detector in capacity performed with ionization smoke detector which is set up with fire objects.

  • PDF

Numerical Analysis on Pressurization System of Smoke Control in Consideration of Flow Rate of Supply and Leakage (보충량과 누설량을 고려한 급기가압 제연시스템의 수치해석 연구)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.87-93
    • /
    • 2010
  • The fact that the smoke hinders evacuation and fire-fighting activities as well as becomes the major cause of life casualty emphasizes the importance of smoke control system. As one of the fire safety standards designed to secure the smoke safety, NFSC501A (Design Guide for Smoke Control System of Special Evacuation Stairwell and Lobby) has been proposed, preventing smoke from penetrating into the smoke-free escape route by raising the pressure of the smoke control zone higher than fire area. For model building of 20 stories, pressurization system was designed according to standard and pressure field of compartments in whole building induced by pressurization system was analyzed using the network model.

Smoke Modeling and Rendering Techniques using Procedural Functions (절차적 함수를 이용한 연기 모델링 및 렌더링 기법)

  • Park, Sang-Hyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.905-912
    • /
    • 2022
  • Virtual reality, one of the core technologies of the 4th industrial revolution, is entering a new phase with the spread of low-cost wearable devices represented by Oculus. In the case of disaster evacuation drills, where practical training is almost impossible due to the risk of accidents, virtual reality is becoming a new alternative that enables effective training. In this paper, we propose a smoke modeling method that can be applied to fire evacuation drills implemented with virtual reality technology. In the event of a fire, smoke spreads along the aisle, and the density of the smoke changes over time. The proposed method models the smoke by applying a procedural function that can reflect the density of smoke calculated through simulation to the model in real-time. Implementation results in the background of the factory show that the proposed method produces models that can express the smoke according to the user's movement.

A Study on the Smoke Removal Equipment in Plant Facilities Using Simulation (시뮬레이션을 이용한 플랜트 시설물 제연설비에 관한 연구)

  • Doo Chan Choi;Min Hyeok Yang;MIn Hyeok Ko;Su Min Oh
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.40-46
    • /
    • 2024
  • Purpose: In this study, in order to ensure the evacuation safety of plant facilities, we analyze the relationship between the height of smoke removal boundary walls, the presence or absence of smoke removal equipment, and evacuation safety. Method: Using fire and evacuation simulations, evacuation safety was analyzed through changes in the height of the smoke removal boundary wall, air supply volume and exhaust volume according to vertical dista. Result: In the case of visible drawings, if only 0.6m of boundary wall is used, the time below 5m reaches the shortest, and 1.2m of boundary width is 20% longer than when using smoke removal facilities. In the case of temperature, 1.2m is 20% longer than 0.6m when only the boundary width is used without smoke removal facilities. Conclusion: It was found that increasing the length of the smoke removal boundary wall could affect visibility, and installing a smoke removal facility would affect temperature. Therefore, it is determined that an appropriate smoke removal plan and smoke removal equipment should be installed in consideration of the process characteristics.

An Application of Evacuation Model for Rail Passenger Car (철도차량에 대한 피난모델 적용)

  • Kim, Jong-Hoon;Kim, Woon-Hyung;Lee, Duck-Hee;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.123-128
    • /
    • 2007
  • To predict the fire and smoke hazards of rail car with a evacuation model is essential for achieving life safety of all passengers in the event of fire. Currently, more than 30 different evacuation models are available and expected increasing demand in high population density areas as a metro train station. This paper includes brief history of evacuation models and review some key factors of design egress scenario, these are pre-movement time, egress route, location of fire, overturned carriage, and configuration of rail car. Applying the egress model for rail passenger car, users need to confirm the model's ability of physiological, psychological responses effecting to pre-movement time of individual or crowd unit, representation of complexity of carriage layout, and evaluation of effects of smoke.

  • PDF

A Study on the Management of Evacuation Safety Zone through the Prediction of Smoke Movement (재난약자시설의 연기성상 예측을 통한 피난안전구획 관리에 관한 연구)

  • Jin, Seung-Hyeon;Kim, Hye-Won;Han, Ji Woo;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.100-101
    • /
    • 2019
  • For buildings where a large number of the evacuees who are restricted to evacuation behavior compared to normal people, evacuation safety zones should be secured against fire. In order to form a safe haven safety zone, we are going to predict the performance of the building and describe the plan to secure a safe haven zone accordingly.

  • PDF

A Study on Securing Safety of Evacuation through Smoke Control in Case of Fire at the Central Corridor Type Intelligent Buildings (중복도형 인텔리전트빌딩 화재시 연기제어를 통한 피난안전성 확보에 관한 연구)

  • Min, Se Hong;Lee, Jae Moon;Bae, Yeon Jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.117-127
    • /
    • 2015
  • This study investigated the smoke blocking and control systems for the safety of residents evacuation and for the prevention of smoke spread through the central corridor in the event of central corridor type of intelligent building fire. We offered additional ways of utilizing smoke ventilators and intake ventilation equipment and utilized CFD-based fire simulation program(FDS Ver.5.5.3) in order to analyze the effect. As a result, many differences in the smoke block effect, depending on the application of smoke ventilator and location of installation, was found. In addition, the result was found that larger effect was showed not in the case of application of smoke ventilator in central corridor only but application in fire room. The reason is that the smoke leakage is blocked primarily as air is flowed in the fire room through open door by operation of intake smoke ventilator in the public corridor and secondarily, the smoke leakage to the public corridor could be blocked as fire and smoke were released to the opened smoke ventilator continuously. Especially, the effect was maximized through complex interactions by applying smoke ventilator and intake ventilation equipment in corridor together rather than applying smoke ventilator and intake ventilation equipment independently. The proposed measure through this study shall be considered from architectural plan as one of ways for blocking from smoke spread to the central corridor in the central corridor type of intelligent building. In addition, flaws on regulation shall be established and supplemented.

The Development of a Functional Pressure Controller in Smoke Management Systems for the Fire Safety of Buildings (화재시 제연 및 피난을 위한 기능성 차압 조절장치 개발에 관한 연구)

  • Jung, Ki-Chang;Kim, Jeong-Hun;Lee, Jung-Yun
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.44-48
    • /
    • 2004
  • The smoke and toxic gases generated from the building fires are proved to cause human death. Therefore, the necessity and significance of smoke control have been emphasized, and lots of studies for developing improved smoke management system have been carried out. In this study, the experiments were conducted to evaluated a function and performance in newly developed smoke management system using mechanical pressurization. As a result of this experiment, the differential pressure was 40Pa${\sim}$60Pa and the air velocity through the door was 0.7m/s between safety zone and fire zone. The functional pressure control equipment which could make proper pressure and maintain differential pressure between safety zone and fire zone was developed. And it will give a lot of helps to evacuation activity for peoples in building and fire fighting.

Optimization for Ventilation Capacity of Large Enclosure Considering Fire Load (화재하중을 고려한 대공간 제배연 용량 최적화 연구)

  • Ahn, Chan-Sol;Kim, A-Ram
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.478-481
    • /
    • 2011
  • This study is intended to evaluate and optimize the characteristics of smoke spreading and the appropriateness of evacuation time extended by operation of smoke control system during fire within the underground space of the building structured in compliance with the smoke control system performance criteria from the local fire safety standard, which has been currently applied to the buildings in Korea. Using the heat release per unit weight of the combustibles, a numerical analysis both in case of smoke control system in operation and the system not in operation was carried out at the several different shopping malls. From the viewpoint of securing the evacuation time, the results were compared in an attempt to assess the appropriateness of the fire safety criteria.

  • PDF

Investigation on Users' Perception and Certification Status and Donning of Smoke Masks (방연마스크에 대한 사용자 인식, 인증 현황 및 착용성 조사)

  • Hyunwoo Son;Yeongeun Park;Eungwoo Lee;Eunji Kim;Youngbo Choi
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.68-73
    • /
    • 2023
  • Smoke masks have attracted great interests and have been supplied widely for the improvement of the safety during fire evacuation. However, there is not sufficient research on the practical utility, certification status and easy-donning about commercial smoke masks, therefore it is difficult to determine the actual usefulness of the smoke masks. In this study, we conducted a survey on users' perceptions and experiences about the smoke masks, and investigated the status of certification of 54 commercial smoke masks. We also performed donning tests and examined degrees of discomfort for 4 types of the smoke masks. Although 22% of 235 respondents had experienced the smoke masks before the test, and 23% of the respondents did not know the smoke masks, 93% of the respondents expected that the smoke masks could protect users from fire smokes and toxic gases. It was found that 41% of the commercial smoke masks did not certify according to domestic or overseas performance standards. Most certification standards have not effectively regulated maximum wearing time for the smoke masks. Only ASTM E 2952 and KFIS 024 had specific standards for the maximum wearing time of 30 s. As a result of donning tests for 4 types of smoke masks, the wearing time of the hood-type mask and self-contained smoke mask exceeded 30 s, therefore these types of smoke masks might increase the required safe evacuation time. On the other hand, it was also found that short education about the donning could reduce the wearing time by 19% and numbers of improper wearing by 89%.