지하구 케이블의 연소특성 실험 (Experiments on the Behavior of Underground Utility Cable in Fire)

  • 박승민;김운형;윤명오
    • 한국화재소방학회논문지
    • /
    • 제16권2호
    • /
    • pp.75-80
    • /
    • 2002
  • 지하공동구에 사용되는 케이블의 연소특성 중 열방출량과 연기 유독성 실험을 수행하였다. 열 방출량 실험은 22.9 kv 전력용 케이블을 대상으로 ISO 9705 규격의 공간에서 수행하였으며 유독성가스의 정량적 위험성 평가를 위하여 NES 713(British-Naval Engineering Standard)을 적용하였다. 실험 결과 측정높이 1.2 m를 기준으로 계산한 케이블의 열 방출 율은 60 kW로 예측되었다. 한편, 케이블의 연기유독성을 위한 NES 실험 결과, 인체에 치명적인 CO의 경우 30분 노출시 사망에 이를 수 있고 의식불명상태가 될 수 있는 수준으로 판정되었다

Particle System Graphics Library for Generating Special Effects

  • Kim Eung-Kon
    • International Journal of Contents
    • /
    • 제2권2호
    • /
    • pp.1-5
    • /
    • 2006
  • The modeling and animation of natural phenomena have received much attention from the computer graphics community. Synthetic of natural phenomena are required for such diverse applications as flight simulators, special effects, video games and other virtual realty. In special effects industry there is a high demand to convincingly mimic the appearance and behavior of natural phenomena such as smoke, waterfall, rain, and fire. Particle systems are methods adequate for modeling fuzzy objects of natural phenomena. This paper presents particle system API(Application Program Interfaces) for generating special effects in virtual reality applications. The API are a set of functions that allow C++ programs to simulate the dynamics of particles for special effects in interactive and non-interactive graphics applications, not for scientific simulation.

  • PDF

지하철 축소모형 객차화재 수치해석적 연구 (SIMULATION STUDIES ON A REDUCED-SCALE SUBWAY COACH FIRE)

  • 김동운;박원희;김치훈;정우성;이덕희
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.501-504
    • /
    • 2010
  • In this study, fire behavior for subway coach fire in the 1/10 reduced scale model is analyzed using numerical analysis method (FDS). The size of the reduced model coach is 1.9 m long, 0.290 m high and 0.235 m. The simulation is carried out only one-sided four doors of the coach are opened. A fire source is the n-heptane pool fire with a mean heat release rate 2.33 kW. Smoke temperature, heat release rate and mass loss rate for the model are calculated.

  • PDF

An Experimental Investigation of Swirl Angle in a Horizontal Round Tube by Flow Visualization Method

  • Tae-Hyun Chang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권7호
    • /
    • pp.879-888
    • /
    • 2003
  • Swirling air flow in a horizontal round tube was experimentally studied for its visualization. The present investigation deals with swirl angle, flow visualization studies and accompanying vortex core behavior by using oil smoke and a hot wire anemometer for Re = 40,000 and 50000 at X/D = 41, 59 and 71. In the swirl air flow, a vortex core was formed at high swirl intensity along the test tube. The swirl angle and the vortex core depended on the swirl intensity along the test tube. The results of swirl angles measured by flow visualization and hot wire reasonably agree with those of previous studies.

바니린의 열분해에 관한 연구 - $800^{\circ}C$에서 바니린의 열분해 생성물의 확인을 중심으로 - (A STUDY ON THE PYROLYSIS OF VANILLIN - IDENTIFICATION OF VANILLIN PYROLYTIC PRODUCTS AT $800^{\circ}C$ -)

  • 곽재진;김옥찬;박태무
    • 한국연초학회지
    • /
    • 제6권2호
    • /
    • pp.131-139
    • /
    • 1984
  • The pyrolytic behavior of vanillin, a flavorant for manufactured cigarettes, was examined to find its contribution to the smoke composition. Vanillin was pyrolyzed at various temperatures (500-$900^{\circ}C$) in a stream of nitrogen. Pyrolytic products at $800^{\circ}C$ were identified with GC/MS. As increasing temperature, pyrolytic products did not appear with qualitative differences. Component analysis of the resulting products showed that 24 compounds were identified. and phenolic compounds were major products. The pyrolytic pathway of vanillin was also discussed.

  • PDF

Dynamic PIV Measurement of Swirl Flow in a PC Fan

  • ARAMAKI Shinichiro;HAYAMI Hiroshi
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.41-45
    • /
    • 2004
  • The dynamic particle image velocimetry (PIV) is consisted of a high frequency pulse laser, high speed cameras and a timing controller. The three velocity components of flow downstream of an axial flow fan for PC cooling system are measured using the dynamic PIV system. An Axial flow fan has seven blades of 72 mm in diameter. The rotating speed is 1800 rpm. The downstream flow is visualized by smoke particles of about $0.3-1\;{\mu}m$ in diameter. The three-dimensional instantaneous velocity fields are measured at three downstream planes. The swirl velocity component was diffused downstream and the change in time-mean vorticity distribution downstream was also discussed. The spatio-temporal change in axial velocity component with the blades passing is recognized by the instantaneous vector maps. And the dynamic behavior of vorticity moving with the rotating blades is discussed using the unsteady vorticity maps.

  • PDF

스월비 변화가 직접분사식 디젤기관의 연소특성에 미치는 영향 (Effects of Swirl Ratio on Combustion Characteristics in DI Diesel Engine)

  • 권순익
    • 한국산업융합학회 논문집
    • /
    • 제6권2호
    • /
    • pp.149-153
    • /
    • 2003
  • Besides the fuel spray behavior and combustion chamber shape. an air motion has a key role on exhaust gas emission and performance in a DI diesel engine. A swirl ratio represents the ratio of the intake swirl velocity to the engine speed. The main purpose in this work is to investigate the effects of the swirl ratio to the combustion characteristics. A shroud valve machined to change the swirl ratio. Test was carry out by changing the engine speed, nozzle diameter and swirl ratio in a single cylinder diesel engine. From this study, the optimized combustion was found at swirl ratio 2.7. And it was also found that the increasing the maximum cylinder pressure with an increasing swirl ratio lead to decrease a smoke and to increase NOx.

  • PDF

BRI2002를 중심으로 한 건축물의 연기유동과 피난용량설정방안에 관한 연구 (A Study on the Smoke behavior and set-up of evacuation capacity in buildings at BRI2002)

  • 서동구;김동은;홍해리;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 춘계학술논문발표회 논문집
    • /
    • pp.487-492
    • /
    • 2010
  • 최근 건축물은 초고층화 대형화 지하심층화 등으로 변모하고, 더나아가 복합화가 진행되고 있다. 이러한 건축물은 화재 발생 시 기존의 건축물보다 큰 인재로서 다가오며, 특히 연기로 인한 피해가 주를 이루고 있다. 하지만 국내의 경우 연기의 피해에 따른 피난용량설정 및 계획 등에 관한 연구가 미흡한 실정이다. 따라서 본 연구는 이에 대하여 일본의 BRI2002 모델의 알고리즘분석에 따른 피난 안전과의 연계성 방안을 도출하여, 향후 국내의 연기를 중심으로한 피난용량설정방안에 대하여 서술하였다.

  • PDF

전산수치해석 기반 화재훈련 VR 시뮬레이터의 개발 (A Development of Fire Training Simulator Based on Computational Fluid Dynamics Simulation)

  • 차무현;이재경;박성환;최병일
    • 한국CDE학회논문집
    • /
    • 제14권4호
    • /
    • pp.271-280
    • /
    • 2009
  • An experience based training system concerning various fire situations which may result many casualties has been required to make rapid decision and improve the responsiveness. Recently, the necessity of virtual reality (VR) based training system which can replace a dangerous full-scale fire training and be easily adopted to the training or evaluation process is increasing. This study constructed tile virtual environment according to pre-defined scenarios, utilized the FDS(Fire Dynamics Simulator), three dimensional computational fire analysis program, to derive numerically simulated data on the propagation of fire. Finally, by visualizing the realistic fire and smoke behavior through virtual reality technique and implementing real-time interaction, we developed a VR-based fire training simulator. Also, in order to ensure the sense for tile real of a virtual world and reaI-time performance at the same time, we proposed appropriate data processing and space search algorithms, demonstrate d the value of proposed method through experiments.

일본의 BRI2002를 활용한 건물의 연기성상에 대한 해석적 연구 (An analytical Study on the Smoke Behavior using BRI 2002 in Japan)

  • 김동은;서동구;홍해리;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 추계학술발표회 자료집
    • /
    • pp.287-290
    • /
    • 2010
  • 최근 건축물은 초고층화 대형화 지하심층화 등으로 변모하고, 더나아가 복합화가 진행되고 있다. 이러한 건축물은 화재 발생 시 기존의 건축물보다 큰 인재로서 다가오며, 특히 연기로 인한 피해가 주를 이루고 있다. 하지만 국내의 경우 연기의 피해에 따른 피난용량설정 및 계획 등에 관한 연구가 미흡한 실정이다. 따라서 본 연구는 기존 개발된 일본의 연기 거동 해석모델인 BRI2002의 메커니즘를 이용하여, 가상의 건축물에서의 Case Study를 통한 연기거동을 분석함으로서 향후 연기거동에 대한 연구의 방향성 및 기초적인 자료를 구축하는데 그 목적이 있다.

  • PDF