In this study, fire behavior for subway coach fire in the 1/10 reduced scale model is analyzed using numerical analysis method (FDS). The size of the reduced model coach is 1.9 m long, 0.290 m high and 0.235 m. The simulation is carried out only one-sided four doors of the coach are opened. A fire source is the n-heptane pool fire with a mean heat release rate 2.33 kW. Smoke temperature, heat release rate and mass loss rate for the model are calculated.