• Title/Summary/Keyword: Slow wave Structure

Search Result 59, Processing Time 0.021 seconds

원거리 지진자료로부터 유추된 한반도의 P파 도달시간 이상에 대한 연구

  • Lee, Deok-Gi;O, Seok-Hun;Yun, Yong-Hun;Yang, Jun-Mo
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.2
    • /
    • pp.87-97
    • /
    • 2002
  • P wave travel-time delays have been analyzed and average travel-time anomalies due to lateral variation of the crustal structure have been calculated at the broad-band earthquake observatories of Korea Meteorology Administration (KMA) using the teleseismic deata collected during the period from 2000 to 2001. Maximum variation in the relative travel-time residuals is almost 1.5 seconds Azimuthal variation in the travel-time residuals is observed to indicate the existence of lateral P velocity heterogeneity beneath the stations with velocity contrasts of -4~4%. The estimated average travel-time delays are ranging from 0.05 to 0.3 seconds at the stations including Seoul, Chuncheon, Kanneung, Uljin, and Ulleung Island showing slow velocity contrasts of 0~4% P through the crust. Faster velocity contrasts of 0~4% have been observed at the stations including Seosan, Taejeon, Daegu, Seoguipo, and Busan showing average travel-time delays ranging from -0.05 to -0.3 seconds.

  • PDF

마이크로파 응용을 위한 고온초전도 필터 서브-시스템

  • 강광용;김현탁;곽민환
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.3
    • /
    • pp.20-40
    • /
    • 2003
  • Since unloaded Q-value of a high-temperature superconductor(HTS) filter is very high, a bandpass filter(BPF) and a lowpass filter(LPF) with an increase of pole numbers can be fabricated without an increase of an insertion loss(IL) ; recently a 70-pole BPF is developed in USA. They have an abrupt skirt property and an excellent attenuation level for out-of band. Moreover, they can be miniaturized when lumped element resonators or the slow-wave characteristic are used. Technology of fabricating a HTS epitaxial film as well as a film of a 4 inch area also makes the planar type filter with a various structure and an enhanced power handling capability possible. Recently, the HTS filter subsystems composed of a planar-type HTS filters, a GaAs-based LNA and a mini-cryocooler are developed. The extended receiver front- end subsystems for mobile radio communications decrease the noise-figure level of the communication system and the frequency interference interacted adjacent bands, and increase the efficiency of frequency and the capacity of communication system. In this paper, theory for developing the HTS filter, its kinds, its design rules, its characteristics are reviewed. The feature of the research and market trends related to the HTS filter systems for the receiver front-end subsystem of mobile base station are surveyed.

The Effect of Daytime Exercise Load on Sleep Structure and the Secretion of Growth Hormone, Testosterone, Cortisol, $\beta$-endorphin during Sleep (주간 운동량이 수면구조와 수면 중 Growth Hormone, Testosterone, Cortisol, $\beta$-endorphin의 분비에 미치는 영향)

  • Kim, Jin-Hang;Hong, Seung-Bong;Yi, Ji-Yeong;Cho, Keun-Chong
    • Sleep Medicine and Psychophysiology
    • /
    • v.6 no.2
    • /
    • pp.116-125
    • /
    • 1999
  • Objectives: The purpose of this study is to investigate the effect of exercise load on sleep structure and stress hormone secretion during sleep. Methods: Five male physical education students were included in this study after giving their written, informed consents in the Research Institute for Sports Science at the University of Hanyang. All subjects have performed for at least 3 years in a regular aerobic exercises such as football, basketball, and running. The subjects were divided into three groups ; NOE(non-exercise), MDE(middle duration exercise), LDE(long duration excercise). MDE group maintained a total of 120 min exercise, and LDE group maintained a total of 300 min exercise by football, basketball or badminton. All subjects were acclimatized to the experimental sleep condition by spending one night under expermental conditions, including the placement of an intravenous catheter. During the subsequent night(24:00-08:00), somnopolygraphic sleep recordings were obtained, and blood for measuring growth hormone, cortisol, testosterone, and $\beta$-endorphin was collected every 120 min throughout the night. Blood samples were obtained from prominent forearm veins of subjects. Then, the samples were immediately placed in ice and centrifuged within 10 min at 3000 rpm at $4^{\circ}C$. Statistical analyses were performed using the SPSS/$PC^+$. Data were analyzed by one-way ANOVA with repeated measures. Results: No significant differences among groups were observed in sleep latency, total sleep time, stage 2 sleep, and slow wave sleep. However, daytime exercise produced significant changes in stage 1 sleep, REM sleep, stage 2 sleep latency, REM sleep latency and sleep efficiency. Stage 1 sleep, stage 2 sleep latency, and REM sleep latency significantly increased in LDE compared to those of NOE and MDE groups. But the amount of REM sleep significantly decreased in LDE. Sleep efficiency of MDE was higher than those of NOE and LDE. The blood concentrations of growth hormone, testosterone, and cortisol during night sleep were significantly lower in LDE than in NOE. $\beta$-endorphin concentrations in blood during night sleep were not different among groups. Conclusion: The daytime exercise load was significantly related to sleep structure and stress hormone secretion during night sleep. Long duration exercise showed a harmful effect on sleep structure and hormone secretion. However, middle duration exercise had a beneficial effect on sleep structure and hormone secretion during sleep.

  • PDF

A Method to Reduce the Size of Amplifiers using Defected Ground Structure (결합된 접지 구조를 이용한 증폭기의 소형화 방법)

  • Lim, Jong-Sik;Park, Jun-Seok;Kim, Chul-Soo;Lee, Young-Tak;Ahn, Dal;Nam, Sang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.5
    • /
    • pp.436-444
    • /
    • 2002
  • This paper presents a new method, which uses defected ground structure (DGS) on the ground planes of planar transmission lines such as microstrip and coplanar waveguide (CPW), to reduce the size of amplifiers. The main idea can be summarized as follow; DGS on the ground plane of microstrip or CPW line shows an increased slow-wave effect due to the additional equivalent L-C components. So the electrical length of the transmission line with DGS is longer than that of the standard transmission line for the same physical length. Then, the length of the transmission line with DGS can be shortened in order to maintain the original electrical length to be the same. This leads the matching of the original amplifier to be kept. In order to show the proposed method is valid, two kinds of amplifiers, the original amplifier and reduced amplifier, are fabricated, measured, and compared using both microstrip and CPW. The measured performances of the reduced amplifiers with DGS are quite similar to the ones of the original amplifiers for both microstrip and CPW amplifiers, even though the size of matching networks of the amplifiers with DGS are much smaller than those of the original amplifiers.

A Technique for Reducing the Size of Microwave Amplifiers using Spiral-Shaped Defected Ground Structure (맴돌이형 결함접지구조를 이용한 마이크로파 증폭기의 소형화 방법)

  • Lim, Jong-Sik;Jeong, Yong-Chae;Ahn, Dal;Nam, Sang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.9
    • /
    • pp.904-911
    • /
    • 2003
  • A new method to reduce the size of microwave amplifiers spiral-shaped defected ground structure(Spiral-DGS) is proposed. A microstrip line having Spiral-DGS on the ground plane produces increased slow-wave factor and electrical length for the fixed physical length. In addition, it provides an excellent rejection characteristic for a finite frequency band like band rejection filters. The rejection band is used for rejecting harmonic components of amplifiers. The reduced microstrip line lengths in matching networks by Spiral-DGS are 39 % and 44 % of the original ones in input and output matching networks, respectively. It is shown that the measured S-parameters of the reduced amplifier agree well with those of the original amplifier. The measured second harmonic of the reduced amplifier is much less than that of the original amplifier by at least 10 dB. The same technique is applied to reject the third harmonic using the proper Spiral-DGS for the third harmonic frequency. The measured third harmonic is smaller than that of the original amplifier by 25 dB.

Improved Power Performances of the Size-Reduced Amplifiers using Defected Ground Structure (결함 접지 구조를 이용하여 소형화한 증폭기의 개선된 전력 성능)

  • Lim, Jong-Sik;Jeong, Yong-Chae;Han, Jae-Hee;Lee, Young-Taek;Park, Jun-Seok;Ahn, Dal;Nam, Sang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.8
    • /
    • pp.754-763
    • /
    • 2002
  • This paper discusses the improved power performances of the size-reduced amplifier using defected ground structure (DGS). The slow-wave effect and enlarged electrical length occur due to the additional equivalent circuit elements of DGS. Using these properties, it is possible to reduce the length of transmission lines in order to keep the same original electrical lengths by inserting DGS on the ground plane. The matching and performances of the amplifier are preserved even after DGS patterns have been inserted. While there is no loss in the size-reduced transmission lines at the operating frequency, but there exists loss to some extent at harmonic frequencies. This leads to the more excellent inherent capability of harmonic rejection of the size-reduced amplifier. Therefore, it is expected tile harmonics of the size-reduced amplifier are smaller than those of the original amplifier. The measured second harmonic, third order intermodulation distortion (IMD3), and adjacent channel power ratio (ACPR) of the size-reduced amplifier are smaller than those of the original amplifier by 5 dB, 2~6 dB, and 1~4 dB, respectively, as expectation.

Therapeutic Change of Sleep Structure and Function by Continuous Positive Airway Pressure Application in Obstructive Sleep Apnea Syndrome (폐쇄성(閉鎖性) 수면(睡眠) 무호흡증(無呼吸症)에서 지속적(持續的) 상기도(上氣道) 양압술(陽壓術)에 따른 수면구조(睡眠構造) 및 기능(機能) 변화(變化))

  • Jeong, Do-Un;Yoon, In-Young;Shim, Young-Soo
    • Sleep Medicine and Psychophysiology
    • /
    • v.1 no.2
    • /
    • pp.172-181
    • /
    • 1994
  • Obstructive sleep apnea syndrome(OSAS) is most frequently diagnosed in the sleep laboratories and its severity is objectively estimated. In terms of treatment, the most prevalent method is the continuous positive airway pressure(CPAP) application as of now. However, in Korea, CPAP is still not sufficiently known and it is attributable to the fact that sleep study facilities have not been popularized. In this article, the authors present their own experience with CPAP in nine subjects with OSAS. In this study, CPAP was found to decrease stage 1 sleep and to increase stage 2 sleep, with increasing mean oxygen saturation and decreasing lowest oxygen saturation during nocturnal sleep. Also, it tended to increase sleep continuity and generally to improve sleep architecture. Rebound slow wave and/or REM sleep stages during CPAP were also noted in 8 out of 9 cases. The authors suggest that CPAP should be considered as the primary mode of treatment for patients with obstructive sleep apnea syndrome and related educational programs for physicians should be developed and provided by sleep specialists.

  • PDF

Overnight Growth Hormone Secretions and Sleep Patterns in Idiopathic Short Stature Children (특발성 저신장 아동의 야간 성장호르몬 분비와 수면양상)

  • Seo, Sang Young;Lee, Kee Hyoung;Eun, Baik Lin;Sohn, Chang Sung;Tockgo, Young Chang;Shin, Chol;Kim, Baek-Hyun
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.4
    • /
    • pp.363-369
    • /
    • 2003
  • Purpose : Pharmacologic provocation test of growth hormone(GH) is a non-physiologic method and has several limitations for diagnosing growth hormone(GH) deficiency. Spontaneous GH release studies could be important in understanding the pathophysiology of children with poor growth but normal responses to GH provocation tests. Also, the relationship between nocturnal GH secretions and sleep patterns in short stature children is poorly understood. The aim of this study is to determine whether there are differences in sleep patterns and nocturnal GH secretory profiles between idiopathic short stature children and a normal stature group. Methods : Spontaneous nocturnal GH secretions and sleep patterns were evaluated in 12 prepubertal idiopathic short stature children with normal responses to provocation tests and 9 normal stature controls. Blood samples were taken every 30 minutes from 22:00-06:30 and sleep patterns were analyzed by polysomnography. Results : The mean GH level during sleep was significantly lower in short stature children than in controls. The peak GH level after sleep, coincident with the first slow wave sleep, was lower in the short stature group. The slow wave sleep times of short stature children were decreased compared with those of normal subjects. Conclusion : These results suggest that overnight serial GH sampling is helpful to identify short stature children with subnormal GH secretions, and sleep structure differences may be associated with decreased overnight GH secretions in short stature children.

Clinical Characteristic and Respiratory Disturbance Index as Correlates of Sleep Architecture in Obstructive Sleep Apnea Syndromes Diagnosed with Polysomnography (수면다원기록법으로 확진된 폐쇄성 수면무호흡증 환자의 임상특성, 그리고 호흡장애지수와 수면 구조간의 상관관계)

  • Kim, Seog-Joo;Park, Doo-Heum;Kim, Yong-Sik;Woo, Jong-Inn;Ha, Kyoo-Seob;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.8 no.2
    • /
    • pp.113-120
    • /
    • 2001
  • Objectives: Obstructive sleep apnea syndrome is common and may produce various symptoms and serious complications. A substantial number of research articles on obstructive sleep apnea syndrome have been published in Korea. However, we found such limitations as lack of sufficient sample size and lack of polysomnography-proven cases. Therefore, we aimed at studying clinical features and sleep structure in a sufficient number of Korean patients with obstructive sleep apnea syndrome diagnostically confirmed with polysomnography. Methods: We studied 801 subjects referred to the Division of Sleep Studies, Seoul National University Hospital, who were diagnosed as having obstructive sleep apnea syndrome with polysomnography. Subjects were excluded if they had central sleep apnea syndrome, periodic limb movement disorder, narcolepsy or REM sleep behavior disorder. Foreign patients were also excluded. First of all, we studied the clinical features of the subjects. Secondly, we compared sleep-related parameters of the study subjects with those of age/sex-matched normal values. Thirdly, correlations of respiratory disturbance index (RDI) with each of the sleep-related parameters were calculated. Results: Among the 801 subjects, 668 were male subjects (83.4%) and 133 female subjects (16.4%). Their mean age was 46.6 years (${\pm}13.5$). The mean body mass index (BMI) was 25.8 (${\pm}3.8$) and subjects with BMI was over 28.0 accounted for 22.8% of the total. Fifty subjects (6.2%) were found to take benzodiazepines. Mean RDI and mean nocturnal oxygen saturation of all subjects was 31.2 (${\pm}24.4$) and 94.5% (${\pm}3.6$), respectively. In comparison with normal values, the subjects showed longer sleep latency, lower sleep efficiency, decreased total slow wave sleep % (TSWS %), and decreased total REM sleep % (TREM %)(p<0.01 in all). RDI had a negative correlation with each TSWS % and TREM % (p<0.01, p<0.01). However, RDI did not have significant correlation with either sleep latency or sleep efficiency. Conclusion: In this study, 6.2% of patients diagnosed as having obstructive sleep apnea syndrome were found to take benzodiazepines, although they are generally considered to be of litte benefit or even dangerous because of the respiratory suppressing effect. The proportion of obese subjects was only 22.8% and Korean patients with obstructive sleep apnea syndrome seem to be less obese than those described in foreign journals. This study also suggests that the severity of obstructive sleep apnea syndrome may have a more significant effect on sleep architecture defined as TSWS % and TREM % than on sleep efficiency.

  • PDF