• 제목/요약/키워드: Single-step

검색결과 1,662건 처리시간 0.025초

난용계 육성기의 단백질 공급체계가 육성계의 성장 및 영양소 섭취량과 산란능력에 미치는 영향 (Effect of Protein Feeding Systems for Egg-type Growing Pullets on Pullet Growth, Nutrient Consumption and Subsequent Laying Performance)

  • 이규호;정연종
    • 한국가금학회지
    • /
    • 제21권4호
    • /
    • pp.257-266
    • /
    • 1994
  • Three protein feeding systems for egg-type pullets involving conventional step-down protein 18-15-12%), step-up protein(12-15-18%) and single-stage low protein (13-13-13%) with an iso-energy level of 2,900 ME kcal /kg were compared to examine the effect on pullet growth and subsequent laying performance. During the growing period, pullets subjected to the step-up and single-stage low protein feeding systems were lighter in body weight and consumed less feed and netabolizable energy than those on the conventional step-down protein feeding system(P<0.05). 3ut the pullets on the step-up protein diet consumed more protein, and those on the single-stage low protein diet consumed less protein than those on the step-down protein diet(P<0.05). Also, he feed cost was less in pullets on the single-stage low protein diet than in those on the other systems(P<0.05). During the laying period, sexual maturity was later in hens reared on the step-up and single-stage low protein diets than in those on the step-down protein diet(P<0.05), however, average hen-day egg production and egg weight were not significantly affected by the protein feeding systems in the growing period. Daily feed intake and feed required per egg were significantly reduced in hens on the single-stage low protein diet compared to those on conventional protein feeding system(P<0.05). It was concluded that the 13% single-stage low protein feeding system produced smaller pullets with less feed, energy, protein, and feed cost during the growing period, and hens reared on that system consumed less feed during the laying period without any impairment of production compared to the conventional rearing system.

  • PDF

단층라멜라 돔의 시공 중 접합부 강성에 따른 좌굴특성 (The Buckling Characteristics of Single-Layer Lamella Domes according to the Joint Flexibility under Construction)

  • 석창목;김철환;정환목
    • 한국공간구조학회논문집
    • /
    • 제11권2호
    • /
    • pp.111-118
    • /
    • 2011
  • 단층 래티스 돔과 같은 스페이스 프레임 구조물은 대공간을 확보하기 위하여 강접합으로 설계함으로써 경제성과 심미성 등의 장점을 확보할 수 있다. 그러나 실제 구조물의 접합상태는 완전한 강접합도, 완전한 핀접합도 아닌 접합부 상세에 따라 중간적인 특성을 나타내는 반강접합이 일반적이다. 본 연구에서는 저자 등에 의해 제안된 Step-Up Erection 공법을 적용하여 단층 라멜라 돔의 접합부 강성에 따른 시공 중의 좌굴 특성을 해석적으로 규명하였다. 얻어진 결과는 시공 Step이 증가할수록 그리고 접합부 휨강성이 핀접합에 가까울수록 좌굴내력은 감소하였으며, 좌굴모드는 시공 Step이 증가할수록, 접합부 휨강성이 강접합에 가까울수록 돔의 정점 부근에서 뜀좌굴 현상에 의한 절점좌굴이 발생하였다. 또한, 시공 Step이 낮을 경우 저면 경계부의 원주방향 부재에서 큰 인장응력 분포를 나타내었으며, 시공 Step이 증가할수록 정점 중앙부에서 큰 압축응력 분포를 보였다. 완성돔을 제외한 시공 중 Step에서는 Step이 증가할수록, 접합부 휨강성이 핀접합에 가까울수록 저면부 경선방향 부재에서 큰 인장응력 분포를 나타내었다.

LDPC 코드의 빠른 복원을 위한 1단으로 구성된 적응적인 오프셋 MS 알고리즘 (Single-Step Adaptive Offset Min-Sum Algorithm for Decoding LDPC Codes)

  • 임소국;강수린;이해기;김성수
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.53-57
    • /
    • 2010
  • Low-density parity-check (LDPC) codes with belief-propagation (BP) algorithm achieve a remarkable performance close to the Shannon limit at reasonable decoding complexity. Conventionally, each iteration in decoding process contains two steps, the horizontal step and the vertical step. In this paper, an efficient implementation of the adaptive offset min-sum (AOMS) algorithm for decoding LDPC codes using the single-step method is proposed. Furthermore, the performances of the AOMS algorithm compared with belief-propagation (BP) algorithm are investigated. The algorithms using the single-step method reduce the implementation complexity, speed up the decoding process and have better efficiency in terms of memory requirements.

A General Solution of Determining Storage Coefficient From Multi-Step Pumping Test Recovery Data

  • Jin-Yong Lee;Kang-Kun Lee
    • 대한지하수환경학회지
    • /
    • 제7권1호
    • /
    • pp.20-23
    • /
    • 2000
  • 양수시험시 획득되는 회복자료만을 이용하여 저유계수를 추정하는 일반해를 제시하였다. Banton and Bangoy(1996)가 제시한 단 단계(single-step) 양수시험에서 얻는 회복자료를 이용한 저유계수 추정해를 일반적인 다단계 (multi-step)시험 회복자료에도 적용 가능하게 확장한 것이다. 본 연구에서 구한 일반 해를 이용하여 저유계수와 투수계수를 구한 결과 다른 방법으로 구한 결과 값과 잘 일치하였다.

  • PDF

The effectiveness of step feeding strategies in sequencing batch reactor for a single-stage deammonification of high strength ammonia wastewater

  • Choi, Wonyoung;Yu, Jaecheul;Kim, Jeongmi;Jeong, Soyeon;Direstiyani, Lucky Caesar;Lee, Taeho
    • Membrane and Water Treatment
    • /
    • 제11권1호
    • /
    • pp.79-85
    • /
    • 2020
  • A single-stage deammonification with a sequencing batch reactor (SBR) that simultaneous nitritation, anaerobic ammonia oxidation (anammox), and denitrification (SNAD) occur in one reactor has been widely applied for sidestream of wastewater treatment plant. For the stable and well-balanced SNAD, a feeding strategy of influent wastewater is one of the most important operating factors in the single-stage deammonification SBR. In this study, single-stage deammonification SBR (working volume 30L) was operated to treat a high-strength ammonium wastewater (1200 mg NH4+-N/L) with different feeding strategies (single feeding and nine-step feeding) under the condition without COD. Each cycle of the step feeding involved 6 sub-cycles consisted of aerobic and anoxic periods for partial nitritation (PN) and anammox, respectively. Contrary to unstable performance in the single feeding, the step feeding showed better deammonification performance (0.565 kg-N/m3/day). Under the condition with COD, however, the nitrogen removal rate (NRR) decreased to 0.403 kg-N/m3/day when the Nine-step feeding strategies had an additional denitrification period before sub-cycles for PN and anammox. The NRR was recovered to 0.518 kg-N/m3/day by introducing an enhanced multiple-step feeding strategy. The strategy had 50 cycles consisted of feed, denitrification, PN, and anammox, instead of repeated sub-cycles for PN and anammox. The multiple-step feeding strategy without sub-cycle showed the most stable and excellent deammonification performance: high nitrogen removal efficiency (98.6%), COD removal rate (0.131 kg-COD/m3/day), and COD removal efficiency (78.8%). This seemed to be caused by that the elimination of the sub-cycles might reduce COD oxidation during aerobic condition but increase the COD utilization for denitrification period. In addition, among various sensor values, the ORP pattern appeared to be applicable to monitor and control each reaction step for deammonification in the multiple-step feeding strategy without sub-cycle. Further study to optimize the number of multiple-step feeding is still needed but these results show that the multiple-step feeding strategy can contribute to a well-balanced SNAD for deammonification when treating high-strength ammonium wastewater with COD in the single-stage deammonification SBR.

PLGA 미립구를 이용한 새로운 단회 접종 항원 전달 시스템의 개발 (Improved Antigen Delivery Systems with PLGA Microsphere for a Single-Step Immunization)

  • 윤미경;최영욱
    • Journal of Pharmaceutical Investigation
    • /
    • 제34권1호
    • /
    • pp.1-14
    • /
    • 2004
  • A promising approach to the development of a new single-step vaccine, which would eliminate the requirement for multiple injections, involves the encapsulation of antigens into microspheres. Biodegradable poly(lactide-co-glycolide) (PLGA) microspheres gave us a bright insight for controling antigen release in a pulsatile fashion, thereby mimicking two or tree boosting injections. However, in spite of the above merits, the level of immunization induced by a single-shot vaccination is often lower tan two doses of alum-adsorbed antigen. Therefore, optima modification of the microsphere is essential for the development of single-step vaccines. In the review, we discuss the stability of antigen in microsphere, safety and non-toxic in human and encapsulation technology. Also, we attempted to outline relevant physicochemical properties on the immunogenicity of microsphere vaccine and attainment of pulsatile release pater by combination of different microsphere, as well as to analyze immunological data associated with antigen delivery by microsphere. Although a lot of variables are related to the optimized microsphere formulation, we could conclude that judicious choice of proper polymer type, adjustment of particles size, and appropriate immunization protocol along with a suitable adjuvant might be a crucial factor for the generation of long-lasting immune response from a single-step vaccine formulation employing PLGA microsphere.

Variable Step Size Maximum Power Point Tracker Using a Single Variable for Stand-alone Battery Storage PV Systems

  • Ahmed, Emad M.;Shoyama, Masahito
    • Journal of Power Electronics
    • /
    • 제11권2호
    • /
    • pp.218-227
    • /
    • 2011
  • The subject of variable step size maximum power point tracking (MPPT) algorithms has been addressed in the literature. However, most of the addressed algorithms tune the variable step size according to two variables: the photovoltaic (PV) array voltage ($V_{PV}$) and the PV array current ($I_{PV}$). Therefore, both the PV array current and voltage have to be measured. Recently, maximum power point trackers that arc based on a single variable ($I_{PV}$ or $V_{PV}$) have received a great deal of attention due to their simplicity and ease of implementation, when compared to other tracking techniques. In this paper, two methods have been proposed to design a variable step size MPPT algorithm using only a single current sensor for stand-alone battery storage PV systems. These methods utilize only the relationship between the PV array measured current and the converter duty cycle (D) to automatically adapt the step change in the duty cycle to reach the maximum power point (MPP) of the PV array. Detailed analyses and flowcharts of the proposed methods are included. Moreover, a comparison has been made between the proposed methods to investigate their performance in the transient and steady states. Finally, experimental results with field programmable gate arrays (FPGAs) are presented to verify the performance of the proposed methods.

선형시불변 단일입출력 시스템의 영점과 계단응답 특성 (Zeros and Step Response αlaracteristics in LTI SISO Systems)

  • 이상용
    • 제어로봇시스템학회논문지
    • /
    • 제15권8호
    • /
    • pp.804-811
    • /
    • 2009
  • This paper deals with the relationship between zeros and step response of the second and third order LTI(Linear Time Invariant) SISO(Single-Input and Single-Output) systems. As well known, if a system has a single unstable zero, it shows the step response with undershoot and, on the other hand, a stable zero slower than the dominant pole causes the system to have the step response with overshoot. Generally, in the case of a system with two unstable real zeros, it is known to have B type undershoot[7]. But there are many complex cases of the step response extrema corresponding to zeros location in third order systems. This paper investigates the whole cases depending on DC gains of the additive equivalence systems and they are to be classified by the region of zeros which are related to the shape of the step response. Moreover, monotone nondecreasing conditions are proposed in the case of complex conjugate zeros as well as the case of two stable zeros.

A NEW SINGLE-PHASE Z-SOURCE CYCLOCONVERTER

  • Khai, Nguyen Minh;Jung, Young-Gook;Lim, Young-Cheol
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.318-320
    • /
    • 2007
  • Single-phase cycloconverters are widely used for ac-ac power conversion especially for speed control of ac drives. In this paper, a new single-phase to single-phase Z-source cycloconverter topology is proposed. The proposed single-phase Z-source cycloconverter can boost to a desired voltage with various frequency. Thus, it is called a frequency step-down and amplitude voltage step-up converter. The operating principle of the proposed topology is presented. Analysis and simulation for this single-phase Z-source cycloconverter are also presented.

  • PDF