• Title/Summary/Keyword: Signal matching

Search Result 513, Processing Time 0.027 seconds

Maximum Entropy Power Spectral Estimation of Two-Dimensional Signal (2차원 신호의 최대 정보량을 갖는 전력 스펙트럼 추정)

  • Sho, Sang-Ho;Kim, Chong-Kyo;Lee, Moon-Ho
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.3
    • /
    • pp.107-114
    • /
    • 1985
  • This paper presents the iterative algorithm for obtaining the ME PSE(Maximum Entropy Power Spectral Estimation) of 2-dimensional signals. This problem involves a correction matching power spectral estimate that can be represented as the reciprocal of the spectral of 2-dimensional signals. This requires two matrix inversion every iterations. Thus, we compensate the matrix to be constantly positive definite with relaxational parameters. Using Row/Column decomposition Discrete Fourier Transform, we can decrease a calculation quantity. Using Lincoln data and white noise, this paper examines ME PSE algorithms. Finally, the results output at the graphic display device. The 2-dimensional data have the 3-dimensional axis components, and, this paper develops 3-dimensional graphic output algorithms using 2-dimensional DGL(Device Independent Graphic Library) which is prepared for HP-1000 F-series computer.

  • PDF

Deriviation of the z-transfer Function of Optimal Digital Controller Using an Integral-Square-Error Criterion with the continuous-data Model in Linear Control Systems (선형연속데이터형 제어계통의 플랜트와 디지털모델의 오차자승적분지표에 의한 최적디지탈제어기의 전달함수유도)

  • Park, Kyung-Sam
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.6
    • /
    • pp.211-218
    • /
    • 1983
  • In this paper, an attempt is made to match the continuous state trajectory of the digital control system with that of its continuous data model. Matching the state trajectories instead of the output responses assures that the performances of the internal variables of the plant as well as the output variables are preserved in the discretization. The mathematical tool used in this research is an extended maximum principle of the Pontryagin type, which enables one to synthesize a staircase type of optimal control signals, such as the output signal of a zero-order hold asociated with a digital controller. A general mathematical expression of the digital controller which may be used to replace the analog controller of a general system while preserving as mauch as possible the performance characteristics of the original continuous-data control system is derived in this paper.

  • PDF

Interoperating Methods of Heterogeneous Networks for Personal Robot System (퍼스널 로봇을 위한 이기종 네트웍 운용 방안)

  • Choo, Seong-Ho;Li, Vitaly;Lee, Jung-Bae;Park, Tai-Kyu;Jang, Ik-Gyu;Jung, Ki-Deok;Choi, Dong-Hee;Park, Hong-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2004.05a
    • /
    • pp.86-88
    • /
    • 2004
  • Personal Robot System in developing, have a module architecture, each module are connected through variety network system like ethernet, WLAN (802.11), IEEE 1394 (firewire), bluetooth, CAN, or RS-232C. In developing personal robot system. We think that the key of robot performance is interoperablity among modules. Each network protocol are well connected in the view of network system for the interoperability. So we make a bridging architecture that can routing converting, and transporting packets with matching each network's properties. Furthermore, we suggest a advanced design scheme for realtime / non-realtime and control signal (short, requiring hard-realtime) / multimedia data (large, requiring soft-realtime).

  • PDF

Characteristics of output for optical parametric oscillation in periodically poled $LiNbO_3$ pumped by dioded-pumped Nd:YAG laser (다이오드 펌프 Nd:YAG 레이저로 펌프된 주기적 분극 반전된 $LiNbO_3$ OPO의 출력 특성)

  • 조기호;이범구
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.68-69
    • /
    • 2003
  • Quasi-Phase-Matching(QPM)을 이용한 Optical Parametric Oscillation(OPO)은 높은 효율과 작은 Walk-off 효과를 보인다는 장점을 가지고 있다. 그러나 작은 펌프빛의 크기로 인한 빛세기의 증가는 optical damage와 photorefractive effect 야기하고, 이러한 요인으로 안정적인 고출력 연속발진에 있어서는 그 한계가 있으리라고 생각되어진다. 본 연구에서는 주기가 27.7 $mu extrm{m}$인 Periodically poled LiNbO$_3$(PPLN)을 비선형매질로 이용하여 10 kHz의 고반복률을 갖는 다이오드 펌프 Nd:YAG 레이저에서의 Quasi-Phase-Matched Optical Parametric Oscillation의 Signal파의 출력특성 및 안정화에 대하여 조사를 하였다. (중략)

  • PDF

Block Sparse Signals Recovery Algorithm for Distributed Compressed Sensing Reconstruction

  • Chen, Xingyi;Zhang, Yujie;Qi, Rui
    • Journal of Information Processing Systems
    • /
    • v.15 no.2
    • /
    • pp.410-421
    • /
    • 2019
  • Distributed compressed sensing (DCS) states that we can recover the sparse signals from very few linear measurements. Various studies about DCS have been carried out recently. In many practical applications, there is no prior information except for standard sparsity on signals. The typical example is the sparse signals have block-sparse structures whose non-zero coefficients occurring in clusters, while the cluster pattern is usually unavailable as the prior information. To discuss this issue, a new algorithm, called backtracking-based adaptive orthogonal matching pursuit for block distributed compressed sensing (DCSBBAOMP), is proposed. In contrast to existing block methods which consider the single-channel signal reconstruction, the DCSBBAOMP resorts to the multi-channel signals reconstruction. Moreover, this algorithm is an iterative approach, which consists of forward selection and backward removal stages in each iteration. An advantage of this method is that perfect reconstruction performance can be achieved without prior information on the block-sparsity structure. Numerical experiments are provided to illustrate the desirable performance of the proposed method.

A Study on Efficient Frequency Control of Transducer for Skin Treatment Using Multi-Frequency Ultrasound (멀티주파수 초음파를 사용하는 피부 치료기기 트랜스듀서의 효율적인 주파수 제어 연구)

  • Park, Jong-Cheol;Kim, Min-Sung
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.8
    • /
    • pp.1038-1048
    • /
    • 2022
  • Ultrasound is one of the effective methods for skin treatment. The skin penetration depth of the ultrasound depends on the ultrasonic frequency, that is, when the ultrasonic frequency is high, the depth is shallow. We have developed a transducer which can generate effectively 3 different ultrasonic frequencies removing interference between 3 types of frequencies according to impedance matching technology. The generated powers of transducer are 40.67W at 3.MHz, 17.46W at 11.7 MHz, and 14.79W at 21.5 MHz. The signal interference between the three frequencies is designed so that they do not interfere with each other by separating the signals using the SPDT (Single Pole, Double Throw) switch. The developed hybrid ultrasound transducer can be applied in skin care or skin treatment and beauty therapy.

Design and Fabrication of a MIC Gate Mixer Using GaAs MESFET (GaAs MESFET을 이용한 MIC 게이트 Mixer의 설계 및 제작)

  • Park, Han Kyu;Kim, Nam Su
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.6
    • /
    • pp.868-873
    • /
    • 1986
  • The Schottky barrier diode has been used as an element of the mixer inspite of its conversion loss. In this paper the use of a GaAs MESFET is shown as a device of mixer, and the conversion gain is obtained. Also, input matching circuits aredesigned by s-parameter and fabricated on a dielectric teflon epoxy fiber glass substrate. According to the results, the conversion gain is 9 dB at the signal frequency of 4 GHz and the intermediate frequency of 1.217GHz.

  • PDF

Array Antenna Design for Ku-Band Terminal of L.E.O Satellite Communication

  • Kang, Seo;Kang, JeongJin;Rothwell, Edward J.
    • International journal of advanced smart convergence
    • /
    • v.11 no.4
    • /
    • pp.41-46
    • /
    • 2022
  • This study is a Ku-band array antenna for the manufacture of low-orbit satellite communication terminals, designed to have miniaturization, high gain, and wide beam width. The transmission of low-orbit satellite communication has a right-rotating circularly polarized wave, and the reception has a left-rotating circularly polarized wave. The 4×8 array antenna was separated for transmission and reception, and it was combined with the RF circuit part of the transmitter and receiver, and was terminated in the form of a waveguide for RF signal impedance matching in the form of a transition from the microstrip line to the waveguide. The 30° beam width of the receiver maximum gain of 19 dBi and the 29° beam width of the transmitter maximum gain of 18 dBi are shown. Through this antenna configuration, the system was configured to suit the low-orbit satellite transmission/reception characteristics.

Pulsed-Bias Pulsed-RF Passive Load-Pull Measurement of an X-Band GaN HEMT Bare-chip (X-대역 GaN HEMT Bare-Chip 펄스-전압 펄스-RF 수동 로드-풀 측정)

  • Shin, Suk-Woo;Kim, Hyoung-Jong;Choi, Gil-Wong;Choi, Jin-Joo;Lim, Byeong-Ok;Lee, Bok-Hyung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.1
    • /
    • pp.42-48
    • /
    • 2011
  • In this paper, a passive load-pull using a GaN HEMT (Gallium Nitride High Electron Mobility Transistor) bare-chip in X-band is presented. To obtain operation conditions that characteristic change by self-heating was minimized, pulsed drain bias voltage and pulsed-RF signal is employed. An accuracy impedance matching circuits considered parasitic components such as wire-bonding effect at the boundary of the drain is accomplished through the use of a electro-magnetic simulation and a circuit simulation. The microstrip line length-tunable matching circuit is employed to adjust the impedance. The measured maximum output power and drain efficiency of the pulsed load-pull are 42.46 dBm and 58.7%, respectively, across the 8.5-9.2 GHz band.

The Performance Comparison of CR-CMA and CM-CMA Adaptive Equalization in 16-QAM Signal (16-QAM 신호에 대한 CR-CMA와 CM-CMA의 적응 등화 성능 비교)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.3
    • /
    • pp.115-120
    • /
    • 2011
  • This paper is concerned with the performance comparison of CR-CMA (Coordinate Reduction-CMA) and CM-CMA (Constellation Matching-Constant Modulus Algorithm) that is used for improving the convergence characteristic and residual intersymbol interference which are used as the performance index for an adaptive equalizer. The equalizer is used to reduce the distortion caused by the intersymbol interference on the wireless and the wired band-limited channel, and the blind method which does not need for extra bandwidth by the training sequence of digital code are researched. Recently, by using the merit of simple operation in the CMA, the performance improvement is obtained by the modifying the cost function of it. In this paper, the new algorithm, CR-CMA and CM-CMA, the performance analysis are performed and compared by computer simulation. The CR-CMA has a superior equalization characteristics in the recovered constellation, convergence speed and residual intersymbol interference than the CM-CMA by computer simulation.