• Title/Summary/Keyword: Side-lobe

Search Result 305, Processing Time 0.025 seconds

Characteristic Investigation According to Structures of Embroidered Radiation Patches at SF-MPAA (SF-MPAA의 자수된 방사체의 구조에 따른 특성 분석)

  • Ki, Hyeon-Cheol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.6
    • /
    • pp.21-26
    • /
    • 2020
  • In this paper, we investigated the characteristics of SF-MPAA depend on the structures of radiators when they were embroidered for realizing embroidered SF-MPAA. As increasing pitches by decreasing numbers of grids in length-direction and width-direction of the embroidered radiator the antenna gain and resonance frequency were trendingly decreased. However the characteristics of antenna were affected very much by the pitch in width-direction but affected relatively less by the pitch in length-direction. Therefore it was beneficial to decrease number of grids in length-direction to decrease conductor ratio. SLL was affected by the combination of length-direction pitch and width-direction pitch. The conductor ratio of embroidered radiator was determined by the ratio of pitch to embroidered thread thickness. When the ratio was less than 5 the conductor ratio was decreased rapidly. But when the ratio was larger than 5 the conductor ratio was decreased slowly and saturated.

UWB impulse generator using gated ring oscillator (게이티드 링 발진기를 이용한 UWB 임펄스 생성기)

  • Jang, Junyoung;Kim, Taewook
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.721-727
    • /
    • 2021
  • This paper proposes a UWB (Ultar-wideband) impulse generator using the gated ring oscillator. The oscillator and PLL circuits which generate a several GHz LO signal for the conventional architecture are replaced with the gated ring oscillator. Therefore, the system complexity is decreased. The proposed architecture controls the duty of enable signal, which is used for the head switch of ring oscillator. The control of the duty enables to tun off the oscillator during the guard interval and stop wasting the power consumption. The pulse shaping method using the counter makes the small side lobe and preserves the bandwidth regardless of the change on the center frequency. Designed UWB impulse generator could change the center frequency from 6.0 GHz to 8.8 GHz with a digital bit control, while it preserves the bandwidth as about 1.5 GHz.

A Case Report of Central Nervous System Disorder Induced Intractable Hiccups Treated with Korean Medicine (중추신경계 질환자에게 이환된 난치성 딸꾹질의 한방치험1례)

  • Moon, Jiseong;Min, Seonwoo;Kim, Yeseul;Park, Jiyoon;Hong, Junghwa;Choi, Dong-jun
    • The Journal of Internal Korean Medicine
    • /
    • v.43 no.2
    • /
    • pp.191-200
    • /
    • 2022
  • Intractable hiccups are those which persist for more than one month and can often occur in patients with disorders of the central nervous system, such as stroke, epilepsy, or brain tumor. An 80-year-old male patient undergoing conservative hemodialysis for diabetic nephropathy, recently developed paralysis and dysphagia due to central nervous system complications including stroke and epilepsy. He was admitted to the ◯◯ Oriental Medicine Hospital, and treated with herbal medicine (Gyulpijugyeo-tang, Jeonssiigong-san, and Ijin-tang) and electrical acupuncture for 30 days. No side effects were observed during hospitalization. The frequency and duration of hiccups were measured daily and found to reduce, and the effect persisted during his admission. The patient took no other nervous system drugs. In conclusion, Korean medicine like gyulpijugyeo-tang and acupuncture can be effective for patients with intractable hiccups who cannot use alternative drugs or treatment, because of other complications.

Mutual interference suppression of the sinusoidal frequency modulated pulse using SHAPE algorithm (SHAPE 알고리즘을 이용한 사인파 주파수 변조 펄스의 상호간섭 억제)

  • Kim, Guenhwan;Lee, Donghwa
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.27 no.5
    • /
    • pp.49-59
    • /
    • 2022
  • The SHAPE algorithm has the advantage of being able to shape the pulse spectrum as desired and design it not to distort other characteristics, so it was used in the active sonar pulse design. In this paper, we propose a pulse design using the SHAPE algorithm for a multi-static sonar system to reduce the cross-correlation between frequency-adjacent pulses and prevent the performance degradation of the pulses themselves. The boundary function of the SHAPE algorithm is set to be limited to the pulse bandwidth. As a result of applying the proposed design method to the sinusoidal frequency modulated pulse, the peak cross-correlation level (PCCL), which means the degree of cross-correlation, was reduced by 44.23 dB. Although the PCCL decreased by several tens of dB, no significant change in the ambiguity function was observed, and the integrated sidelobe level (ISL), which means the average value of the side lobe, increased by 11.64 dB.

Characteristic Verification of Electronically Scanned Array Antenna for a Ku-band FMCW Radar (Ku-대역 FMCW 레이더용 전자식 빔 조향 배열 안테나 특성 검증)

  • Chae-Hyun Jung;Jaemin Lee;Minchul Kim;Hang-Soo Lee;Sungjun Yoo;Sunghoon Jang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.4
    • /
    • pp.65-71
    • /
    • 2023
  • In this paper, the design, fabrication and verification steps of an electronically scanned array antenna(AESA) for a photonics-based Ku-band FMCW radar system is described. The presented system consists of a transmitter and a receiver respectively, which has a same antenna in the transceiver. The designed antenna has 2×8 array configuration and operates at Ku-band. The VSWR(Voltage Standing Wave Ratio) of each 16-radiators and the coupling power between radiators is measured. Also, in order to minimize the radar system damage because of handover power from the transmitter antenna to the receiver antenna when the transmitter works, the isolation between the transmitter antenna and the receiver antenna is optimized by test. As a result, beamwidth, side lobe level and beam steering characteristic are obtained by synthesizing each radiator pattern measurement data after each beam pattern of 16-radiators is measured in the near-field chamber.

Lower Lung Field Tuberculosis (폐 하야 결핵)

  • Moon, Doo-Seop;Lim, Byung-Sung;Kim, Yeon-Soo;Kim, Seong-Min;Lee, Jae-Young;Lee, Dong-Suck;Sohn, Jang-Won;Lee, Kyung-Sang;Yang, Suck-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo;Lee, Jung-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.232-240
    • /
    • 1997
  • Background : Postprimary pulmonary tuberculosis is located mainly in upper lobes. The tuberculous lesion involving the lower lobes usually arises from the upper lobe cavity through endobronchial spread. When tuberculosis is confined to the lower lung field, it often masquerades as pneumonia, lung cancer, bronchiectasis, or lung abscess. Thus the correct diagnosis may be sometimes delayed for a long time. Methods : We carried out, retrospectively, a clinical study on 50 patients confirmed with lower lung field tuberculosis who visited the Department of Pulmonary Medicine at Hanyang University Hospital from January 1992 to December 1994. The following results were obtained. Results : Lower lung field tuberculosis without concomitant upper lobe disease occurred in fifty patients representing 6.9% of the total admission with active pulmonary tuberculosis over a period of 3 years. It occurred most frequently in the third decade but age distribution was relatively even. The mean age was 43 years old. Female was more frequently affected than male (male to female ratio 1 : 1.9). The most common symptom was cough(68%), followed by sputum(52%), fever(38%), and chest discomfort(30%). On chest X-ray of the 50patients, consolidation was the most common finding in 52%, followed by solitary nodule(22%) collapse(16%), cavitary lesion(10%), in decreasing order. The disease confined to the right side in 25 cases, left side 20 cases, and both sides 5 cases. Endobronchial tuberculosis (1) Endobronchial involvement was proved by bronchoscopic examination in 20 of 50patients. (2) Mean age was 44years old and female was more affected than man (male to female ratio 1 : 3). Sputum AFB stain and Mycobacterium tuberculosis culture were positive only in 50% of cases unlikely upper lobe tuberculosis, additional diagnostic methods were needed. In our study, bronchoscopic examination and percutaneous fine needle aspiration biopsy increased diagnostic yield by 18% and 32%, respectively. The most common associated condition was diabetes mellitus(18%) and others were anemia, anorexia nervosa, stomach cancer, and systemic steroid usage. Conclusion : When we find a lower lung field lesion, we should suspect tuberculosis if the patient has diabetes mellitus, anemia, systemic steroid usage, malignancy or other immune suppressed states. Because diagnostic yield of sputum AFB smear & Mycobacterium tuberculosis culture was low, additional diagnostic methods such as bronchoscopy and fine needle aspiration biopsy were needed.

  • PDF

Range Design of Pulse Repetition Frequency for Removal of SAR Residual Image (영상레이더 잔상 제거를 위한 펄스 반복 주파수의 범위 설계)

  • Kim, Kyeong-Rok;Heo, Min-Wook;Kim, Tu-Hwan;Ryu, Sang-Burm;Lee, Sang-Gyu;Lee, Hyeon-Cheol;Kim, Jae-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.11
    • /
    • pp.1653-1660
    • /
    • 2016
  • The synthetic aperture rardar (SAR) is an active sensor using microwaves. It transmits a microwave signal, called a chirp pulse, and receives the reflected signal in a moving platform such as satellite and unmanned aerial vehicle. Since this sensor uses microwaves that can penetrate the atmosphere, SAR generates the images regardless of light and weather conditions. However SAR operates on the moving platform, the Doppler shift and the side-looking observation method should be considered. In addtion, a residual image or ghost image can be occurred according to selection of the pulse repetition frequency (PRF). In this paper, a range design of the PRF for the L-band spaceborne SAR system is studied for prevention of SAR image distortion. And the system is studied for prevention of SAR image distortion. And the system parameter and the PRF are calibrated iteratively according to the proposed system design procedure and design constraints. The MATLAB based on SAR system simulator has been developed to verify the validity of calculated PRF. The developed simulator assumes that SAR sensor is operated by the PRF calculated from the design. The results of the simulator show that the targets in image has a valid peak to side-lobe ratio (PSLR) so that the PRF can be used for the spaceborne SAR sensor.

Surgical Treatment of Benign Lung Tumor (양성 폐종양의 수술적 치료)

  • Park, Kuhn;Cho, Deog-Gon;Park, Jae-Kill;Jo, Geon-Hyon;Wang, Young-Pil;Kwack, Moon-Sub;Kim, Se-Wha;Lee, Hong-Kyun
    • Journal of Chest Surgery
    • /
    • v.25 no.3
    • /
    • pp.258-270
    • /
    • 1992
  • Benign lung tumors have been considered as relatively rare disease, which comprise approximately 8 to 15% of all solitary pulmonary lesions that are detected radiographically. We clinically analized 30 cases of benign lung tumors underwent the operation from Jan. 1970 to Aug.1991 in the department of thoracic and cardiovascular surgery, Catholic University Medical College. We adopted the classification presented by the World Health Organization[WHO], modified from Liebow, and added benign mesothelioma. There were 11 males & 19 females ranging in age from 2 years to 68 years old % the mean age was 38 years old. Of all 30 benign lung tumors, hamartomas [14 cases, 49%] were the most common & followed by hemangiomas [9 cases, 30%], 3 cases of benign mesotheliomas % a case of teratoma, papilloma, arteriovenous malformation and inflammatory pseudotumor. 14 cases of tumors were asymptomatic & were incidentally detected by plane chest x-ray In other cases, chief complaints at admission were coughing, chest discomfort, dyspnea, hemoptysis, and fever. Diagnosis were made by pathological examination; exploratory thoracotomy in 23 patients[76.7%], bronchoscopy in 4 patients and percutaneous needle aspiration biopsy in 3 patients. Precisely, preoperative diagnosis for confirmation of benign lung tumor was made only in 7 cases[23.6%]. Tumors were located on Rt.side[24 cases], especially Rt. middle lobe, and Lt.side[6 cases]. Operation methods were as follows: 21 cases [70%] of lobectomy, 2 cases of segmentectomy, 2 cases of wedge resection, 1 case of pneumonectomy, 1 case of bronchotomy, 2 cases of wedge resection, 1 case of pneumonectomy, 1 case of bronchotomy removal of the endobronchial hamartoma which located at the rt. main stem bronchus and 3 cases of complete resection in benign mesotheliomas. There were no operative death. The post operative complications were developed in 3 cases; post pneumonectomy empyema, wound infection and atelectasis. In conclusion, benign lung tumors must be histologically diagnosed to confirm of benignity and to provide limited resection for preservation of the lung tissue, whenever possible.

  • PDF

OQ2PSK Modulation with Overlapped Raised-Cosine Pulse Shaping (중첩 상승여현 펄스 정형 OQ2PSK 변조)

  • Jeon, Sang Yeop;Chung, Jae-Kyung;Kim, Myoung Jin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.1
    • /
    • pp.7-16
    • /
    • 2015
  • The transmitter of quadrature multiplexed GMSK (QM-GMSK) is composed of two quadrature multiplexed GMSK modulators. QM-GMSK has a slightly increased spectrum main lobe compared with $Q^2PSK$ or QMSK, but it has highly suppressed side lobes. As a result, practical spectrum efficiency of QM-GMSK is achieved. By replacing the baseband elementary pulses of QM-GMSK with their approximate, the squared sinusoid of half-period, offset-$Q^2PSK$($OQ^2PSK$) is obtained. The $OQ^2PSK$ signal has similar spectral properties to QM-GMSK. The transmitter of $OQ^2PSK$ can be simply implemented without the Gaussian lowpass filter, which is required in QM-GMSK transmitter. In this paper, we propose an overlapped pulse shaping in $OQ^2PSK$ with RC(raised-cosine) or SRC(squared raised-cosine) pulses of length longer than the symbol period. Power spectrum of the proposed modulation scheme exhibits further suppressed side lobes, hence enhanced spectrum efficiency is obtained. Simulation results indicate that BER performance of the proposed scheme is comparable to that of $OQ^2PSK$.

흉총창에 의한 심방파열 치험 2례

  • Lee, Doo-Yun;Kwack, Sang-Ryong
    • Journal of Chest Surgery
    • /
    • v.13 no.1
    • /
    • pp.60-65
    • /
    • 1980
  • We have experienced 2 cases of the hunshot wound sof the chest involving cardiac injuries at department of the thoracic surgery, Capital Armed Forces General Hospital during I year from April I 1979 to Jan. 1980. In one case of two patients , he was a 22 years old man who was transported to this emergency room 4 hour 10 minutes after having gunshot wound of the left chest by helicopter. Physical examination showed small inlet in left 3rd ICS and left parasternal border, large outlet in left 8th ICS and left scapular line, no breath sound on left side and distant heart sound. chest roentgenography demonstrated marked pleural effusion in left side and mediastinum shifted to right. As soon as chest X-ray was taken, the bleeding through penetrating wound became profuse and cardiac arrest ensued. Closed chest cardiac massage was started and vigorous transfusion continued, but no effective cardiac activity could not be obtained. The patient was pronounced dead due to exsanguinating hemorrhage from wuwpected cardiac wounds. In this critically injured patient with evidence of intrathoracic hemorrhage and suspected cardiac penetration, only emergency thoracic exploration and immediate surgical control of bleeding points might offer the maximum possibility of survival. The other case was a 23 years old man who was transferred to the emergency room 4 hours 50 minutes after having kmultiple communicated fractures of sternum and linear fracture of right mandible by a missile. Examination revealed about 30% skin loss of the anterior chest wall, weak pulse of 96 beats/min., distant heart sound and decreased breath sounds bilaterally. finding on the chest X-ray films showed multiple sternal fractures, marked pericardial effusion indicating hemopericardium. So, the patient was moved immediately to the operation room where, after endotracheal tube inserted, a median sternotomy was performced. A hemorrhagic congestion of the right upper lobe and marked bulging pericardium were disclosed. The pericardium was opened anterior to right phrenic nerve and exsanguinating hemorrhage ensued from the 0.5cm lacerated wound in the auricle of right atrium. The rupture site of right atrium was occluded with non-crushing vascular clamps and then was over sewn with interrupted sutures. It was thought to be highly possible that he was alive long enough to have cardiorrhaphy because of cardiac tamponade, which prevented exsanguinating hemorrhage. He was taken closed reduction for linear fracture of right mandible 2 weeks after repair of ruptured right auricle in dental clinic. This patient's post-operative course was not eventful.

  • PDF