Parametric Study on Design Factors of the Shutdown Cooling Heat Exchanger Using the Taguchi Method

  • Kim Seong Hoon;Ryu Seung Yeob;Choi Byung Seon;Yoon Juhyeon;Bae Yoon Yeong;Zee Sung Kyun
    • Nuclear Engineering and Technology
    • /
    • 제35권3호
    • /
    • pp.251-259
    • /
    • 2003
  • The Taguchi method was applied to investigate the effect of design factors on the performance of the shutdown cooling heat exchanger in the SMART-P. This method provided the simulation matrix for the KDESCENT program and an efficient tool for analyzing the simulation results. Levels of the design factors were selected by the effectiveness-NTU method. From 18 runs with the KDESCENT program, it was found that the performance of the system was greatly influenced by the inlet temperature at the shell side and the mass flow rate of the reactor coolant at the tube side. After applying the Taguchi method, we identified the important design factor that should be controlled and designed carefully. This method provides an efficient way to estimate the influence of each design factor on a system performance.

Study on velocity profiles around spiral baffle plates in a horizontal circular tube without inner tubes

  • Chang, Tae-Hyun;Lee, Kwon-Soo;Choi, Yoon-Hwan;Lee, Yeon-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권5호
    • /
    • pp.403-411
    • /
    • 2016
  • Usually shell and tube heat exchangers are employed to recover energy between fluids. Recently, numerous papers on these heat exchangers have been published; however, the velocity and temperature profiles or comparison of the features of the flow with or without inside tubes have rarely been described. In this research, experimental and numerical studies were carried out to investigate the characteristics of the flow around the spiral baffle plates without inside tubes in a horizontal circular tube using a particle image velocimetry method and ANSYS 14.0~15.0 version (Fluent). The results showed that swirling flow was produced between the spiral baffle plates. The tangential components were strong between the two spiral baffles; however, the axial or radial velocities components were indicating nearly zero. From the spiral motion in the space of the two baffles, it is considered that there were no dead zones between the spiral baffle.

현장 적용 아이스슬러리 시스템의 열교환기 성능 실험 (The Heat Exchangers Performance Experiment for a Field Application Ice Slurry Cooling System)

  • 이상훈;유호선;이윤표
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1002-1007
    • /
    • 2009
  • The research are performed to check the characteristics of the ice slurry transport system for the district cooling. The system are installed at the 1st floored building which is as large as the $1204\;m^2$ ($86\;m{\times}14\;m$). Three kinds of heat exchanger are selected, such as, plate, spiral and shell & tube type, to apply to the ice slurry systems. Experiment was done in the two cases. The first case, circulation water flow fixed at the design conditions for the state to change the flow of the supply of ice slurry. The second case, Ice slurry flow fixed at the design conditions for the state to change the flow of circulation water. Both side of Energy balance was calculated. The performance of plate heat exchanger is higher than others and it's enthalpy effectiveness is higher too.

  • PDF

Development of a Highly Efficient Boiler System Using a Diesel Engine

  • Lee, D.-H;Lee, D.-Y;Jo, M.-C;Cho, H.-N;Kim, Y.-S
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권2호
    • /
    • pp.367-375
    • /
    • 2004
  • We have developed a highly efficient boiler system using the 2,600cc Diesel engine. In this system, the co-generation concept is utilized in that the electric power is produced by the generator connected to the engine, and waste heat is recovered from both the exhaust gases and the engine itself by the shell-and-tube heat exchangers. The heat exchanger connected to the engine outlet is specially designed such that it not only recovers waste heat effectively from the exhaust gases, but significantly reduces an engine noise. It is found that the total efficiency(thermal efficiency plus electric power generation efficiency) of this system reaches maximum 96.3% which is about 15% higher than the typical Diesel engine boiler system currently being used worldwide.

2상 횡유동을 받는 열교환기 관군의 진동특성 (Vibration Characteristics of Heat Exchanger Tube Bundles in Two-Phase Cross-Flow)

  • 김범식;박태철
    • 소음진동
    • /
    • 제4권2호
    • /
    • pp.199-208
    • /
    • 1994
  • Two-phase cross-flow exists in many shell-tube heat exchangers such as nuclear steam generators, condensers and reboilers. An understanding of damping and of flow-induced vibration excitation mechanisms in necessary to avoid problems due to excessive tube vibration. In this paper, we present the results of experiments on normal-triangular tube bundles of pitch to tube diameter ratio, p/d, 1.22, 1.32 and 1.47. The bundle were subjected to air-water mixtures to simulate realistic mass fluxes and vapour qualities corresponding to void fractions from 5 to 99%. Damping, fluidelastic instability and turbulence- induced excitation are discussed. The behaivior of damping and two vibration mechanisms are different for intermittent flows from for bubbly flows. The effect of pitch to tube diameter ratio and void fraction is dominant on damping and fluidelastic instability.

  • PDF

공기-횡 유동장에 놓인 유연성 실린더 관군의 유체탄성 불안정 (Fluidelastic Instability of Flexible Cylinders in Tube Bundle Subjected to Cross Air-flow)

  • 심우건
    • 한국소음진동공학회논문집
    • /
    • 제17권6호
    • /
    • pp.498-506
    • /
    • 2007
  • Using wind tunnel, experimental approaches were employed to investigate fluidelastic instability of tube bundles, subjected to uniform cross flow. There are several flow-induced vibration excitation mechanisms, such as fluidelastic instability, periodic wake shedding resonance, turbulence-induced excitation and acoustic resonance, which could cause excessive vibration in shell-and tube heat exchanges. Fluidelastic is the most important vibration excitation mechanism for heat exchanger tube bundles subjected to cross flow. The system comprised of cantilevered flexible cylinder(s) and rigid cylinders of normal square array, In order to see the characteristics of flow in tube bundles, particle image velocimetry was used. From a practical design point of view, Fluidelastic instability may be expressed simply in terms of dimensionless flow velocity and dimensionless mass-damping. The threshold flow velocity for dynamic instability of cylinder rows is evaluated and the data for design guideline is proposed for the tube bundles of normal square array.

태양에너지 해수담수화를 위한 3중 효용 증발식 담수기 개발 (Development of 3th Effects Evaporative desalination system for Solar Desalination System)

  • 황인선;주홍진;윤응상;곽희열
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.201-201
    • /
    • 2010
  • The evaporative desalination system with solar energy would be the efficient and attractive method to get fresh water. This study was described the development of Multi Effect Distillation(MED) with solar energy desalination system. The system was designed and manufactured Multi effect distillation on the capacity of $3m^3$/day. The experimental apparatus consists mainly of ejector pump, Hot water pump, flow meter, demister, cooler, evaporator and condenser. Evaporator and condenser were made Shell&Tube Heat Exchanger type with corrugated tube. The experimental variables were chosen $75^{\circ}C$ for hot water inlet temperature, 40, 60 and $80{\ell}$/min for hot water inlet volume flow rate, 6.0 and $8.0{\ell}$/min for evaporator feed seawater flow rate, $18^{\circ}C$ for sea water inlet temperature to cover the average sea water temperature and the salinity of sea water is measured about 33,000 PPM (parts per million). for a year in Korea. This study was analyzed the results of thermal performance of Multi Effect Distillation. The results are as follows, The experimental Multi effect distillation is required about 40 kW heat source for production of $3m^3$/day fresh water. Various operating flow rate was confirm in the experiments to get the optimum design data and the results showed that the optimum total flow was $8.0{\ell}$/min. Comparison of Single Effect Distillation with Multi Effect Distillation showed MED is at least more than double of SED.

  • PDF

배기 열 회수 열교환기 형식이 디젤 엔진 성능에 미치는 영향 (The effect of heat exchanger type for exhaust heat recovery system on diesel engine performance)

  • 김철정;최병철;박권하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권6호
    • /
    • pp.639-647
    • /
    • 2014
  • 지구 온난화와 화석 연료 고갈로 인해 $CO_2$ 저감과 효율 상승을 동시에 만족하는 기술 개발이 요구된다. 배기 열 회수 기술은 두 가지를 모두 만족할 수 있는 대표적인 기술이다. 본 연구는 배기 열 회수 장치를 위한 세 가지 형식의 증발기용 열교환기를 배기관에 설치하여 실험 및 분석하였다. 고속최대부하에서 판형 열교환기의 배압이 가장 높아지고 실린더 최고 압력이 낮아지며 일산화탄소 배출량도 증가하였다. 또한 고속에서 배압이 2배 이상 증가하며 연료소비율이 2% 증가되어 열교환기 중 가장 높은 증가량을 나타내었다. 핀 튜브 열교환기는 전반적으로 배기 배출물이 적게 배출되고 연료소비율도 가장 적게 나타났다. 쉘 앤 튜브는 판형과 핀 튜브 성능의 중간정도이다. 엔진에 미치는 영향으로만 판단할 때 핀 튜브 열교환기가 배기 열 회수에 가장 적합한 열교환기로 판단된다.

엔진 배기열 이용 유기랭킨사이클에 대한 실험적 연구 (Experimental Research on an Organic Rankine Cycle Using Engine Exhaust Gas)

  • 신동길
    • 에너지공학
    • /
    • 제21권4호
    • /
    • pp.393-397
    • /
    • 2012
  • 본 연구에서는 산업용 가스 엔진의 배기 폐열을 회수하여 발전하는 유기랭킨사이클을 구성하고 시스템 성능 분석 실험을 수행하였다. 엔진 배기가스 열을 작동유체(냉매 R134a)에 흡수시키기 위해 Shell & Tube 방식 열교환기를 엔진 배기 매니폴드 후단에 장착하였다. 엔진출력 60 kW인 조건에서 약 63 kW의 배기가스 열을 배출하였으며, 열교환기를 통해 작동유체에 흡수된 열량은 43~46 kW로서 배기가스 열회수율은 68~73%, 최대출력은 4.6 kW로서 배기가스 열량에 대한 최대출력의 비는 7.3%을 나타내었다.