• 제목/요약/키워드: Shading analysis

검색결과 184건 처리시간 0.024초

창호의 단열성능에 따른 공동주택 냉난방 부하량 변화 (The Change of Heating and Cooling Load according to the Thermal Insulation Performance of Window for an Apartment House)

  • 송수빈;김영탁;윤성환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.853-856
    • /
    • 2008
  • Windows have an great effect on annual building load because windows are the weakest parts of building envelope thermally. To reduce the consumption of building energy, the thermal performance of window has to be improved in first place. Therefore this research aims to make a quantitative analysis of the heating and cooling load according to the window thermal performance using the heat load simulation program. As a result of the simulation, annual heat load is down 38% according to the decrease of U-value of window, 1.00 W/$m^2K$. and annual heat load is up 10% according to the decrease of shading coefficient, 0.20. The annual load of the window with Low-E glass is 15% lower than the window with pair glass.

  • PDF

발코니형 BIPV시스템의 발전성능 향상을 위한 적용요소기술 분석 (Analysis of Application Elements for improvement in the generated electric power performance of balcony BIPV System)

  • 김현일;유권종;강기환;소정훈;이길송
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1483-1485
    • /
    • 2004
  • Photovoltaic(PV) technology is a popular part of building vocabulary. It can be used today on both existing and new buildings. Its use in the building envelope is very varied and open ways, such as roofing materials, facades, skylights and shading systems, for creative designers. So, to activate this systems demand appropriate sources of information, performance data of elements and design tools offering architects and designer. Therefore this paper describe application elements for BIPV system and then predict improvement in the generated electric power performance of balcony BIPV system.

  • PDF

그림자 조건에서 태양광 패널의 접속구조에 따른 발전량 분석 (Analysis on Generation Power according to Connection Structure for PV Panel under Shadow Condition)

  • 정우용;김용중;김효성
    • 전력전자학회논문지
    • /
    • 제25권2호
    • /
    • pp.94-102
    • /
    • 2020
  • Considering that the output voltage and current of a single PV panel are limited in PV power generation, a PV array should be constructed by connecting several PV panels in series and parallel to meet the required voltage/power levels for power generation capacity. When a PV array is partially shaded, the maximum power generation depends on the configuration of a PV array and the presence or absence of blocking diodes. This study considers six PV array configurations and the presence or absence of blocking diodes. An optimum connection structure was proposed to maximize power generation in a partial shadow condition. Results were verified through simulation and an experiment.

건물일체형 태양광발전시스템의 특성 분석 (Characteristic Analysis of Building Integrated Photovoltaic System)

  • 강기환;소정훈;박경은;김현일;유권종;김준태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1672-1674
    • /
    • 2005
  • The PV arrays were designed as sunshade devices at the building in the KIER(Korea Institute of Energy Research). The arrays are shaded by the above placed devices. In this paper, it was analyzed that the performance and characteristic of the BIPV system by partial shading could reliably be calculated with Solar Pro.

  • PDF

복숭아 '장호원황도'의 엽위별 잎 발달과 광합성능의 변화에 대한 분석 (Analysis on on the Leaf Growth and Changes of Photosynthetic Characterization by Leaf Position in 'Changhowon Hwangdo' Peach)

  • 윤익구;윤석규;전지혜;남은영;권정현;배해진;문병우;강희경
    • 생물환경조절학회지
    • /
    • 제22권4호
    • /
    • pp.361-365
    • /
    • 2013
  • 전엽 후 10일이 경과하면 잎의 위치별 엽내 엽록소 함량에 큰 차이를 보이지 않았고, 전엽 후 10일이 경과되지 않은 잎의 엽록소 함량은 전엽 경과일수가 적을수록 낮았다. 동일한 잎의 위치에서 전엽 후 경과일수에 따른 엽록소 함량의 경시적 변화는 전엽 직후에 $2.56{\mu}g/cm^2$에서 12일째에는 $6.35{\mu}g/cm^2$까지 급격히 증가하고 이후 약 2개월간 완만한 증가 추세를 보였는데 엽록소 함량이 가장 높은 시기는 전엽 후 11주째로 $9.03{\mu}g/cm^2$이었다. 엽면적은 전엽 직후부터 전엽 후 10일까지 급속하게 증가하였으나 그 이후는 거의 변화가 없었다. 잎의 광합성률은 전엽 후 30일까지는 급격히 증가하여 전엽 30일 후에 $13.8{\mu}mol/m^{-2}/sec^{-1}$로 최대치를 보였으며, 이후에는 잎의 광합성능이 급격하게 떨어졌다. 전엽 후 1주와 4주의 광도에 따른 광합성률은 두 시기 모두 PPFD $600{\mu}mol/m^{-2}/sec^{-1}$까지는 PPFD가 증가할수록 광합성률이 급격히 증가하였으나 이후 PPFD $1,200{\mu}mol/m^{-2}/sec^{-1}$까지는 완만한 증가율을 보이다 그 이상에서는 변화를 보이지 않았다. 전엽 후 1주와 전엽 후 4주간에는 전엽 후 4주가 전엽 후 1주에 비해 PPFD 증가에 따른 광합성률이 높은 경향을 보였다. $CO_2$ 농도별 광합성률은 600ppm까지는 농도가 높을수록 광합성성률이 증가하였으나 그 이상의 농도에서는 변화가 없었다. 차광시간별 엽내 sucrose 함량은 1시간 까지는 차광처리구와 무처리구 간 차이를 보이지 않았으나 2시간부터는 차광처리에서 sucrose 함량이 감소하였다.

반복 소성이 지르코니아 전부도재관의 색조에 미치는 영향 (The effect of repeated firings on the color of zirconia-based all-ceramic system)

  • 장정은;김무현;윤미정;정창모;전영찬
    • 대한치과보철학회지
    • /
    • 제49권1호
    • /
    • pp.73-79
    • /
    • 2011
  • 연구 목적: 각각 다른 방법으로 색조를 부여한 세 가지 지르코니아 전부도재관에서 반복소성이 전부도재관의 색조에 미치는 영향을 비교, 관찰하였다. 연구 재료 및 방법: 지르코니아 코어를 세가지 방법으로 착색(KW군: Masking liner를 사용하여 하부 코어색 차단, KI군: 지르코니아 코어를 금속 산화물 용액에 침전시켜 착색, NM군: 지르코니아 코어를 고온에서 소결하기 전에 금속산화물과 혼합하여 착색)하여 원반형 시편을 제작하였다. 지르코니아 코어 상방에 A3 색조의 상아질 도재를 소성하고 3, 5, 7회 반복소성 후 $L^*a^*b^*$ 값을 측정하여 비교하고 다른 두 가지 색의 3차원 공간에서의 거리를 나타내는 색차방정식을 이용하여 분석하였다. 측정된 결과는 반복측정 (repeated-measures ANOVA) 분석법과 Tukey 다중범위 검증법을 사용하여 소성횟수에 따른 색조변화를 유의수준 5%에서 검정하였다. 결과: 1. 모든 실험군에서 반복소성에 따른 $L^*a^*b^*$값의 변화가 관찰되었다 (P< .001). 2. 반복소성으로 $L^*$값과 $a^*$값 (KI군제외)은 감소하고 $b^*$값은 증가하는 경향을 보였다. 3. ${\Delta}E$값이 1이상 나타난 반복소성횟수는 KW군과 KI군은 3회 그리고NM군은 7회였다. 4. 7회 반복소성 후 ${\Delta}E$값은 KI군 (${\Delta}E$ = 2.26), KW군 (${\Delta}E$ = 1.47) 그리고 NM군 (${\Delta}E$ = 1.08) 순으로 높게 나타났다 (P< .001). 결론: 반복소성이 지르코니아 코어 색조를 부여방법에 따라 전부도재관의 색조에 미치는 영향을 끼쳤다.

PV모듈의 바이패스 다이오드 단락 고장 시 태양광어레이 회로 특성분석 (Electric Circuit Analysis for PV Array on Short-Circuit Failure of Bypass Diode in PV Module)

  • 이충근;신우균;임종록;황혜미;주영철;정영석;강기환;장효식;고석환
    • 한국태양에너지학회 논문집
    • /
    • 제39권6호
    • /
    • pp.15-25
    • /
    • 2019
  • As the installation of photovoltaic systems increases, fire accidents of PV system grow every year. Most of PV system fires have been reported to be caused by electrical components. The majority of fire accidents occurred in combiner box, which is presumed to be short-circuit accidents due to dustproof and waterproof failures or heat deterioration of blocking diode. For this reason, the blocking diode installation became optional by revised PV combiner regulation. In this paper, according to the revised regulation, reverse current that generated by voltage mismatch was measured and analyzed in PV array without a blocking diode. The factors that cause voltage mismatch in array are assumed to be shaded PV module and short circuit failure of bypass diode. As the result of experiment, there is no reverse current to flow under shading condition in module, but reverse current flows on the failure of bypass diode in module. According to the module's I-V characteristic curve analysis, open voltage was slightly reduced due to operation of bypass diode in shading. However, it showed that open circuit voltage has decreased significantly in the failure of bypass diode. This indicates that the difference in open voltage reduction of voltage mismatch factor causes reverse current to flow.

창호에 SHGC를 반영한 공동주택의 방위각별 에너지 효율성 평가를 통한 합리적인 창호 계획 방안 연구 (A Study on the optimized Performance Designing of the Window of the Apartment based on the Annual Energy Demand Analysis according to the Azimuth Angle applying the Solar Heat Gain Coefficient of the Window)

  • 이장범
    • 대한건축학회논문집:계획계
    • /
    • 제35권11호
    • /
    • pp.25-34
    • /
    • 2019
  • It is important to design windows in a reasonable way considering the performance characteristics of the elements of the window rather than just to increase the thermal energy performance of the window. In this study, the Heat-transfer Coefficient as insulation performance of the windows and together with the grade of the glass's SHGC (Solar Heat Gain Coefficient) were analyzed to relate to the energy efficiency performance of the building by azimuth angle. Based on this basic study, the Heat-transfer Coefficient of windows and the SHGC rating of glass were applied to the unit plan of apartment building, and the Heating and Cooling Demand were analyzed by azimuth angle. Apartment plan types were divided into 2 types of Non-extension and extension of balcony. The designPH analysis data derived from the variant of the Heat-transfer Coefficient and SHGC, were put into PHPP(Passive House Planning Package) to analyze precisely the energy efficiency(Heating and Cooling Demands) of the building by azimuth angle. In addition, assuming the 'ㅁ' shape layout, energy efficiency performance and potential of PV Panel installation also were analyzed by floors and azimuth angle, reflecting the shading effects by surrounding buildings. As the results of the study, the effect of Heat Gain by SHGC was greater than Heat Loss due to the Heat-transfer Coefficient. So it is more effective to increase SHGC to satisfy the same Heating Demand, and increasing SHGC made possible to design windows with low Heat-transfer Coefficient. It was also revealed that the difference in annual Heating and Cooling Demands between the low, mid and high floor households is significantly high. In addition to it, the installation of PV Panel in the form of a shading canopy over the window reduces the Cooling Load while at the same time producing electricity, and also confirmed that absolute thermal energy efficiency could not be maximized without controlling the thermal bridge and ventilation problems as important heat loss factors.

열화상 카메라 활용을 위한 토양비료, 차광생육, 유전특성 차이 관련 작물생리 원격탐지 (Applications of Thermal Imaging Camera to Detect the Physiological States Caused by Soil Fertilizer, Shading Growth, and Genetic Characteristic)

  • 문현동;조유나;조은이;김현기;김보경;정회정;권동원;조재일
    • 대한원격탐사학회지
    • /
    • 제38권6_1호
    • /
    • pp.1101-1107
    • /
    • 2022
  • 열화상 카메라를 이용해 식물의 엽온을 측정하는 원격탐사 기법은 농업의 작물 감시 또는 선별에 이용될 수 있는 가능성이 80년대부터 제시되어 왔지만, 그 유용성에 비해 다양한 적용 사례가 적어 제대로 활용되지 못하고 있었다. 하지만, 최근 열화상 카메라 하드웨어 기능의 비약적 발전과 보급에 따라 농업에서의 열화상 카메라 활용이 주목받고 있다. 앞으로의 활용성 증대를 위해 다양한 활용 사례 연구 필요성에 부응하여 본고에서는 석회질 비료를 처리한 벼와 차광조건에서 생육 된 콩의 생리적 변화를 탐지하였고, 내염성 계통 콩에 대해서는 염해 감수성 콩 품종과의 엽온 차이가 선별 가능한 수준임을 보였다. 열화상 카메라의 관측 정확도와 기공 개폐 기반의 분석 기술이 더욱 발전한다면, 스마트팜과 표현체 분석 분야에 활용이 많아질 것으로 기대된다.

난방에너지 사용량 분석을 통한 후강화 로이유리 창호의 단열성능 평가 (Thermal performance evaluation of Temperable Low-e glass window through Heating Energy consumption Analysis)

  • 장철용;김정국;안병립;김준섭;한찬훈
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.200-205
    • /
    • 2012
  • In the high oil price age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating in large percent of whole building loads, and are regarding as the primary target of energy efficiency. In this study, in order to reduce heat loss of buildings, we investigate the thermal performance properties of Temperable Low-e glazing coated Ag membrane that has high electrical conductivity. The Temperable Low-e glazing windows has high insulation and shading properties, and it has strength that can supply various product which consumers want. In order to evaluate thermal performance of temperable windows, we install single low-e windows and double low-e windows in the experimental chamber and analysis the comparison heating energy consumption between single and double Low-e glazing windows. performance evaluation was conducted.

  • PDF