• Title/Summary/Keyword: Sewage disposal facility

Search Result 20, Processing Time 0.034 seconds

Comparative Analysis on NIMBY Facility and Location - Suyeong·Nambu·Haeundae Sewage Disposal Plants Cases - (기피시설 입지의 지역별 비교 및 결정요인 분석 - 수영·남부·해운대하수처리장 사례중심 -)

  • Choi, Yeol;Choi, Jae Do
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3D
    • /
    • pp.491-497
    • /
    • 2006
  • The goal of this research is to explore the opinions of the resident's neighboring within sewage disposal plants, to investigate the differences in accordance with each location of sewage disposal plants, and to examine the determinants to impact on the sewage disposal plants. The multivariate analysis of variance model and regression model are employed as the empirical analysis for this research. The major findings are as follows; as a rule, most of residents represented the sewage disposal plants are essential public facilities. The sewage disposal plants could be positively considered under proper compensation and negotiation, It is found that the satisfaction level against accomplishing process of the sewage disposal plants facilities are very low. In addition, it was revealed that the determinants to impact on the sewage disposal plants showed differently according to each current location of sewage disposal plants. It means that there are no absolutely concrete reasons to oppose the sewage disposal plants and they can be somewhat different by the each local characteristics. Therefore, these findings provide for the policy makers related with the NIMBY facilities including the sewage disposal plants with valuable information.

Development of Data-Flow Control Algorithm of Wireless Network for Sewage Disposal Facility

  • Jung, Soonho;Shin, Jaekwon;Kang, Jeongjin;Lee, Seungyoun;Lee, Junghoon
    • International journal of advanced smart convergence
    • /
    • v.4 no.2
    • /
    • pp.14-19
    • /
    • 2015
  • Recently, water sewage disposal facilities are able to manage real-time data collection and record management through compact broadband modem LAN switching technology. Therefore, it needs more stable and efficient facility management. So, we required practical use of environmental facilities convergence based on broadband integrated modem. In this paper, we proposed short distance wireless communication network of compact broadband modem for sewage disposal facilities. And it received data inside of water treatment facility using the two communication methods (IEEE802.11x and IEEE802.15.4x). Then, our proposed an data-flow control algorithm of wireless network technology will prioritize processing data when emergency happen through collecting data, analysis data and processing. Lastly, we proved usefulness by experiment and simulation analysis.

The Impact of a Basic Environmental Facility Siting on Land Prices : A Case of Sewage Disposal Plant (환경기초시설의 입지가 지가에 미치는 영향 : 하수처리장을 사례로)

  • JUN, Byong-Woon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.3
    • /
    • pp.170-180
    • /
    • 2017
  • This research analyzed the effect of a basic environmental facility siting on the difference in land prices using a case study of Jisan sewage disposal plant in Daegu metropolitan city. To do so, two buffer zones were generated around Jisan sewage disposal plant to 400m at an interval of 200m as a setback distance and 822 officially announced individual land prices were acquired from Korea Ministry of Land, Infrastructure and Transport(MOLIT). Paired samples t-test was performed to compare the mean difference in land prices before and after Jisan sewage disposal plant siting. Results show that the mean land price from each buffer zone was slightly increased after the siting and the difference was statistically significant. Also, the results indicate that the mean land price within 200m was lower than that between 200m and 400m before the siting while there was not different in the mean land price for both buffer zones after the siting. Because Jisan sewage disposal plant did not have a stench and a larger capacity and its surrounding areas were blended by commercial and residential uses, a sewage disposal plant siting had little effect on the fall in land prices unlike previous studies. The findings from this research will provide new reference data for local government and local people with conflicting views on the siting of a basic environmental facility.

- Development of Fuzzy Control System for Process with Irregular Information System - (불규칙한 정보 프로세스를 위한 퍼지제어 시스템 개발)

  • 박주식;김길동;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2003.11a
    • /
    • pp.185-198
    • /
    • 2003
  • This study is to develop and operate the R-FCE(Real-time Fuzzy Control Expert System) model on the SBR(Sequency Batch Reactors) type sewage disposal facility which is for the environmental problem of future and the effective treatment. It is the system that regularly handles the input, output information in real time by the Fuzzy control IF-THEN rule. Nowadays the water pollution caused by the increase of population and the industrialization already exceeds the purifying ability of nature and is getting worse. The sewage disposal facility needs an expert having wide experience and know-how because the quality or quantity of inflow water is so irregular that the process of sewage disposal is difficult. In the nation, however, the accumulation of technology is so weak because field-operators avoid the long-term duty. So the accurate and speedy decision or control of field are difficult in the case of emergency situation.

  • PDF

A Study on Treatment Measures of Carcass Disposal Site Leachate into the Livestock Manure and Sewage Treatment Facilities using NIER-MASS program (NIER-MASS 프로그램을 이용한 가축매립지 침출수 연계처리 방안 연구)

  • Jeong, Dong-Hwan;Lee, Chulgu;Shin, Jinsoo;Kim, Hyunwoo;Yoon, Soohyang;Kim, Yongseok;Yu, Soonju;Kim, Shinjo
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.725-734
    • /
    • 2012
  • The outbreak of foot and mouth disease in November 2010 raised many social, economic and environmental issues and water contaminations by leachate from carcass disposal sites particularly emerged as a serious concern. In oder to efficiently handle these problems, a critical method is required to transport leachate to livestock manure and sewage treatment plants and purify it. This study aims to present the best applicable method to transport leachate from carcass disposal sites into livestock manure and sewage treatment facilities. We investigated the biological and chemical characteristics such as BOD, COD, SS, TN, TP and Total coliforms. Current conjugated treatments in livestock manure and sewage treatment plants was studied by surveying the operations of those facilities. The NIER-MASS(National Institute of Environmental Research - Mass Balance Evaluation System of Sewage Treatment Facilities) program was applied to present the best conjugated treatment method through estimating the maximum daily load to meet the water quality standards in effluent.

Study on Design Method of Control & Monitoring System by Module Network Constitution in Sewage Disposal Facility (오수처리시설의 모듈 네트워크 구성에 의한 제어 및 감시 시스템의 설계방법에 관한 연구)

  • Park, Seung-Hwan;Ku, Ja-Yl;Chae, Su-Kuern
    • 전자공학회논문지 IE
    • /
    • v.46 no.4
    • /
    • pp.66-72
    • /
    • 2009
  • In field of environments, the control and monitoring devices for sewage disposal facilities have been developed to overcome a problem of the water contamination according to industrialization and urbanization. In order to control and monitor the driving motor and the surroundings states of the sewage disposal facilities installed in local stations, this paper presents the design method of efficient module system interconnected by internal network with serial interface. It is expected that the proposed method in this paper is able to provide the more adaptive and flexible design technique for the specification of condition and factors needed in the fast-changed environment market.

Advanced Treatment of Sewage Using Waste Plastic Vessel Media (폐플라스틱용기 미디어를 활용한 오수고도처리)

  • Kim, Jae-Yong;Um, Myeong-Heon;An, Dae-Hyun;Shim, Myeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.58-61
    • /
    • 2006
  • The object of this study was to develop an advanced method for fluid flow and oxygen transmission and increase adhesive property of microorganism to waste plastic vessel that was made of microorganism media. Through lab scale experiments, we found the optimum packed media volume rate and method, and when the optimum condition was applied to pilot plant, we confirmed possibility of advanced treatment. The sewage that was used in the test was the sewage disposal facility established in C and K elementary schools, which utilized waste plastic media oxidation engineering method. Analysis showed that removal efficiency of organic matter, SS, T-N and T-P was very high, that the sewage disposal facility maintained stability of treatment when changeable load of raw sewage flowed in.

Study on operating software for monitoring device network in sewage disposal facility (오수처리시설의 가동상태 확인 기기 네트웤의 운영 소프트워어에 관한 연구)

  • 박승환;김창복;김성선
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.1
    • /
    • pp.74-79
    • /
    • 2002
  • In field of environments the monitoring devices for sewage disposal facilities developed to overcome a problem of the water contamination according to industrializaion and urbanization. This paper presents the operating software for monitoring device network which operator in remote station is able to check and see the operating states of the sewage disposal facilities installed in local stations. The software is executed by the hardware base developed by this study and composed of the Program modules for database, data transmission and operating state analysis. As the result of the proposed software system, it is confirmed that we are able to make improvements of the effectiveness of the operating management for environment equipments.

  • PDF

Analytical Evaluation of Influent Depending on the Occurrence of Rainfall by Case Study of Wastewater Treatment Facility (하수처리시설 사례 별 강우발생 유무에 따른 유입수 분석 평가)

  • Choi, Langkyu;Chung, Jin Do
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.3
    • /
    • pp.35-49
    • /
    • 2019
  • Currently in 2018, Korea has over 600 operating sewage disposal facilities. The law requires a sewage treatment plant to treat 500 tons or more of water per day, and a small-decentralized sewage treatment facility in a community to treat 50 tons or more to less than 500 tons of water per day. However, most facilities fulfill neither the quantity nor the quality requirements from the original design for such reasons as inflow of rainwater and ground water due to deterioration of pipelines and unauthorized input of wastewater in the pipelines. The research has selected 2 representative cases among the technical diagnosif sewage pipelines in many regions within the country to use it as the baseline of: hourly flowrate and BOD water quality analysis in both clear and rainy days, proper plant operation through inflow rate and ratio calculation, and diagnostic evaluation for deterioration of the pipelines and their accessary structures. This also suggests facilities that treats 500 tons or more of inflow per day to sample and analyze the water hourly for 24 hours once a week in both clear weather and rainy weather considering the influence of rainfall on a regular basis.

The Types of Extended-Spectrum ${\beta}$-Lactamases Isolated from Suyeong Sewage Disposal Plant, Busan Environmental Corporation (부산 수영공공하수처리시설에서 분리된 광범위 항균제 베타락 탐 분해효소(Extended-Spectrum ${\beta}$-Lactamase, ESBL) 유형)

  • Kim, Gun-Do;Lee, Hun-Ku
    • Korean Journal of Microbiology
    • /
    • v.46 no.1
    • /
    • pp.38-45
    • /
    • 2010
  • The study performed to identify the type of ESBL against strains which are producing extendedspectrum ${\beta}$-lactamases and isolated from sewage in Suyeong sewage disposal plant, Busan Environmental Corporation. By the standard activated sludge method, Suyeong sewage disposal plant purify living and lavatory sewage gathering from the northeast Busan and the facility purify total 550,000 tons of living sewage disposal a day. 14 strains were isolated by double disk synergy test and the third generation cepha-antibiotics test. Indole, methyl-red, Voges-Proskauer, Simmon's citrate, decarboxylasedihydrolase and sugar-fermentation tests identified as Klebsiella pneumoniae (n=4) and Escherichia coli (n=10). Plasmid-mediated transmission test against isolated 14 strains proved 11 strains transmitted resistance to recipient E. coli J53 (sodium $azide^R$, $ceftazidime^S$). 9 strains of conjugant were expressed ESBL genes transferred from parental strain but 2 conjugants did not expressed. The type of ESBL from each strain was determined by isoelectric focusing points, DNA and amino acids sequencing. The results indicated that the types of ESBL transmitted to recipient E. coli J53 were TEM-1, the parental TEM type and SHV-12 type.