• Title/Summary/Keyword: Series resistance

Search Result 1,021, Processing Time 0.025 seconds

Amplitude dependency of damping of tall structures by the random decrement technique

  • Xu, An;Xie, Zhuangning;Gu, Ming;Wu, Jiurong
    • Wind and Structures
    • /
    • v.21 no.2
    • /
    • pp.159-182
    • /
    • 2015
  • This study focuses on the amplitude dependency of damping of tall structures by the random decrement technique (RDT). Many researchers have adopted RDT to establish the amplitude dependency of damping ratios in super-tall buildings under strong wind loads. In this study, a series of simulated examples were analyzed to examine the reliability of this method. Results show that damping ratios increase as vibration amplitudes increase in several cases; however, the damping ratios in the simulated signals were preset as constants. This finding reveals that this method and the derived amplitude-dependent damping ratio characteristics are unreliable. Moreover, this method would obviously yield misleading results if the simulated signals contain Gaussian white noise. Full-scale measurements on a super-tall building were conducted during four typhoons, and the recorded data were analyzed to observe the amplitude dependency of damping ratio. Relatively wide scatter is observed in the resulting damping ratios, and the damping ratios do not appear to have an obvious nonlinear relationship with vibration amplitude. Numerical simulation and field measurement results indicate that the widely-used method for establishing the amplitude-dependent damping characteristics of super-tall buildings and the conclusions derived from it might be questionable at the least. More field-measured data must be collected under strong wind loads, and the damping characteristics of super-tall buildings should be investigated further.

Flavonoid Inhibitors of β-Ketoacyl Acyl Carrier Protein Synthase III against Methicillin-Resistant Staphylococcus aureus

  • Lee, Jee-Young;Lee, Ju-Ho;Jeong, Ki-Woong;Lee, Eun-Jung;Kim, Yang-Mee
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2695-2699
    • /
    • 2011
  • ${\beta}$ Ketoacyl acyl carrier protein synthase III (KAS III) initiates fatty acid synthesis in bacteria and is a key target enzyme to overcome the antibiotic resistance problem. In our previous study, we found flavonoid inhibitors of Enterococcus faecalis KAS III and proposed three potent antimicrobial flavonoids against Enterococcus faecalis and Vancomycin-resistant Enterococcus faecalis with MIC values in the range of 128-512 ${\mu}g/mL$ as well as high binding affinities on the order from $10^6$ to $10^7\;M^{-1}$. Using these series of flavonoids, we conducted biological assays as well as docking study to find potent flavonoids inhibitors of Staphylococcus aureus KAS III with specificities against Staphylococcus aureus and Methicillin-resistant Staphylococcus aureus. Here, we propose that naringenin (5,7,4'-trihydroxyflavanone) and eriodictyol (5,7,3',4'-tetrahydroxyflavanone) are potent antimicrobial inhibitors of Staphylococcus aureus KAS III with binding affinity of $3.35{\times}10^5$ and $2.01{\times}10^5\;M^{-1}$, respectively. Since Arg38 in efKAS III is replaced with Met36 in saKAS III, this key difference caused one hydrogen bond missing in saKAS III compared with efKAS III, resulting in slight discrepancy in their binding interactions as well as decrease in binding affinities. 4'-OH and 7-OH of these flavonoids participated in hydrogen bonding interactions with backbone carbonyl of Phe298 and Ser152, respectively. In particular, these flavonoids display potent antimicrobial activities against various MRSA strains in the range of 64 to 128 ${\mu}M$ with good binding affinities.

Evaluation of Compressibility for Normally Consolidated South-east Coast Clay Using CPT and DMT (CPT와 DMT를 이용한 남동해안 정규압밀 점토의 압축성 추정)

  • Hong, Sung-Jin;Chae, Young-Ho;Lee, Moon-Joo;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.4
    • /
    • pp.21-32
    • /
    • 2011
  • A series of in-situ and laboratory tests were performed for the clayey soils of Busan area in order to develop the methods to evaluate the compressibility using CPT and DMT results. The laboratory tests show that the clayey layers of Busan areas are normally consolidated, and their compression indices are turned out to be 0.5~1.3. From the analysis of test results, correlation factors between the cone resistance and constrained modulus (${\alpha}_m$ and ${\alpha}_n$) are observed to decrease with increasing plasticity index, and the correlation factor between the dilatometer modulus and constrained modulus $(R_M)$ increases with $1/I_D$. Based on these relationships, the methods evaluating the constrained modulus from CPT and DMT results are suggested. It is shown that the prediction method by CPT underestimates the constrained modulus of improved ground, whereas the prediction method by DMT is suitable for evaluating the constrained modulus of improved and unimproved ground.

The Behavior and Resistance of Connected-pile Foundations for Transmission Tower from In-situ Lateral Load Tests (송전용 철탑기초의 현장수평재하시험을 통한 연결형 말뚝기초의 거동 및 지지력특성)

  • Kyung, Doo-Hyun;Lee, Jun-Hwan;Paik, Kyu-Ho;Kim, Dae-Hong;Kim, Dae-Hak
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.2
    • /
    • pp.57-70
    • /
    • 2012
  • For soft ground, a pile foundation is typically used as a substructure of transmission tower. However, differential settlement between the foundations can cause structural damage of transmission tower. The connected-pile foundation is a type of group foundation consisting of four foundations connected with beams, and it was suggested in USA and Japan. In this study, a series of 1/8 scale model pile tests were performed to investigate the effect of load direction and stiffness of connecting beam on the responses of connected-pile foundation. As a result, the load capacities of the connected-pile foundation were larger than those of the conventional group pile foundation. For example, under the given test conditions in this paper, the resistibility against differential settlement was improved significantly for connected-pile foundation and its efficiency was maximized when the stiffness of connecting beams is about 25% of the mat foundation.

Electrochemical Characteristics of Hybrid Capacitor and Pulse Performance of Hybrid Capacitor / Li-ion Battery (Hybrid Capacitor의 전기화학적 특성 및 Hybrid Capacitor / Li-ion Battery의 펄스 방전 특성)

  • Lee, Sun-Young;Kim, Ick-Jun;Moon, Seong-In;Kim, Hyun-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.12
    • /
    • pp.1133-1138
    • /
    • 2005
  • In this study, we have prepared, as the pluse power source, a commercially supplied Li-ion battery with a capacity of 700 mAh and AC resistivity of 60 md at 1 kHz and nonaqeous asymmetric hybrid capacitor composed of an activated carbon cathode and MCMB anode, and have examined the electrochemical characteristics of hybrid capacitor and the pulse performances of parallel connected hybrid capacitor/Li-ion battery source. The nonaqueous asymmetric hybrid capacitors constituted with each stack number of pairs composed of the cathode, the porous separator and the anode electrode were housed in Al-laminated film cell. The 10 stacked hybrid capacitor, which was charged and discharged at a constant current at 0.25 $mA/cm^2$ between 3 and 4.3 V, has exhibited the capacitance of 108F and the lowest equivalent series resistance was 32 $m{\Omega}$ at 1 kHz. On the other hand, the enhanced run time of Li-ion battery assisted by the hybrid capacitor was obtained with increasing of current density and pulse width in Pulse mode. The best improvement, $84\;\%$ for hybrid capacitor/Li-ion battery was obtained in the condition of a 7C-rate pulse (100 msec)/0.5C-rate standby/$10\;\%$ duty cycle.

Durability Assessment for Crushed Sand Wet-mix Shotcrete Mixed with Mineral Admixtures (부순모래를 사용한 습식 숏크리트의 광물성 혼화재료 혼입에 따른 내구성 평가)

  • Lee, Kyeo-Re;Han, Seung-Yeon;Nam Gung, Kyeong;Yun, Kyong-Ku
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.5
    • /
    • pp.607-614
    • /
    • 2014
  • The purpose of this dissertation was to investigate the effect of mineral admixtures, such as fly ash, blast furnace slag powder, meta kaolin and silica fume, on the basic properties and durability of crushed sand shotcrete, selecting a series of shotcrete mixtures with a variable admixture. Compressive strength increased as the content of mineral admixtures increased, specially it was the most effective when using meta kaolin both at sample specimen and core after shotcreting. Rapid chloride ion permeability test and sulfuric acid resistance test showed that both durability increased as the substitute rate of mineral admixture increased. In air void analysis with image analysis, the targeted the spacing factor and specific surface were not satisfied because air-entrained agent was not used.

The Effects of Moxibustion on Heart Rate Variability in Cancer Patients (쑥뜸치료가 암환자의 심박변이도에 미치는 영향)

  • Kim, Ok-Hee;Choi, Jung-Eun;Yoon, Jeung-Won;Yoo, Hwa-Seung
    • Journal of Korean Traditional Oncology
    • /
    • v.16 no.1
    • /
    • pp.15-31
    • /
    • 2011
  • Objective : The study aims to investigate the effect of moxibustion treatments on autonomic nervous system function of cancer patients through the evaluation of heart rate variability (HRV) biofeedback testing. Materials and Methods : Six cancer patients from inpatient care unit of Dunsan Oriental Hospital, Daejeon University were given three moxibustion treatment sessions every other day over one week period on five Oriental Medicine meridian points CV4, CV6, CV12, KD1, and PC8. HRV biofeedback was conducted before and after each treatment sessions. Three areas of analyses were done from the test conducted; Time Domain Analysis, Frequency Domain Analysis and Autonomic Nervous System (ANS) balance analysis. Results : Time Domain Analysis has shown increased Standard Deviation of all Normal R-R Intervals (SDNN), and decreased Mean Heart Rate and Physical Stress Index (PSI) levels, with statistical significance (P<0.05). In Frequency Domain Analysis, series of moxa treatments have increased Total Power (TP), Very Low Frequency Oscillation Power (VLF), High Frequency Oscillation Power (HF), normalized HF values while decreasing Low Frequency Oscillation Power (LF), normalized LF and LF/HF ratio with statistical significance (P<0.05). The values of ANS activity, ANS balance, Stress resistance, Stress index, have also shown significant changes. For cardiac stability stroke volume power (SP) and Blood Vessel Tension (BVT) were followed, which were both increased after treatment. All changes were statistically significant (P<0.05). Conclusion : The results have shown a positive correlation between the moxibustion treatments and autonomic nervous system responses on cancer patients through the HRV biofeedback testing. This study suggests possible application of moxibustion treatments for managing ANS functions of cancer patients, although additional studies with larger population are necessary to confirm the data.

A Study on Effect of Various Cooling Methods in Motion of High-Precision Ball Screw (고속 고정밀 볼 스크류 구동에 따른 강제 냉각방식의 효과에 관한 연구)

  • Kim, Su-Sang;Xu, Zhe-Zhu;Kim, Hyun-Koo;Lyu, Sung-Ki
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.3
    • /
    • pp.254-259
    • /
    • 2013
  • Ball screw system is widely used as a precision mechanical linear actuator that translates rotational motion to linear motion for its high efficiency, great stiffness and long life. Recently, according to the requirements of high accuracy and stiffness, the pre-load on the ball screw which means of remove the backlash in the ball screw is usually used. Because of the preload which means the frictional resistance between the screw and nut, becomes a dominating heat source and it generates thermal deformation of ball screw which is the reason for low accuracy of the positioning decision. There are several methods to solve the problem that includes temperature control, thermal stable design and error compensation. In the past years, researchers focused on the error compensation technique for its ability to correct ball screw error effectively rather than the capabilities of careful machine design and manufacturing. Significant amounts of researches have been done to real-time error compensation. But in this paper, we developed a series of cooling methods to get thermal equilibrium in the ball screw system. So we find the optimum cooling type for improving positioning error which caused by thermal deformation in the ball screw system.

Characteristics of metal contact for silicon solar cells (실리콘 태양전지의 금속전극 특성)

  • Cho, Eun-Chel;Kim, Dong-Seop;Min, Yo-Sep;Cho, Young-Hyun;Ebong, A.U.;Lee, Soo-Hong
    • Solar Energy
    • /
    • v.17 no.1
    • /
    • pp.59-66
    • /
    • 1997
  • The solar cell electrical output parameters such as the open circuit voltage($V_{oc}$) and short circuit current density($V_{sc}$) are intrinsic characteristics depending on junction depth, doping concentration, metal contacts barriers and cell structure. As a role of thumb for solar cell design, the metal contact barriers for phosphorus doped emitter should have lower work function in order to provide lower series resistance. The fabrication of PESC(passivated emitter solar cell) structure usually involves the use of titanium as a metal contact barrier. Chromium, which work function is similar to titanium but conductance is higher than titanium is being investigated as the new metal contact barrier. Although titanium has lower work function difference than chromium, the electric performances of chromium as contact barrier are higher than titanium. This better performance is attributed to the lower resistivity from chromium. This paper, therefore, compares the attributes of metal barrier contacts using titanium and chromium.

  • PDF

Characteristic Analysis of Double sided Slotless Halbach Array Permanent Magnet Linear Generator with Three Phases Concentrated Winding of Cored Type by using Analytical Method (해석적 방법을 이용한 3상 집중권 권선을 갖는 양측식 슬롯리스 고정자 Halbach 배열 영구자석 선형 발전기의 특성해석)

  • Seo, Sung-Won;Choi, Jang-Young;Hong, Keyyong;Kim, Kyong-Hwan
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.2
    • /
    • pp.58-65
    • /
    • 2015
  • This paper deals with the generating characteristic analysis of permanent magnet linear generator (PMLG) with double-sided Halbach magnet array mover and three phases concentrated stator windings by using analytical method. On the basis of a magnetic vector potential and Maxwell's equations, governing equations are obtained, and magnetization modeling for Halbach magnet array is performed analytically by using the Fourier series. And then, we obtain electrical parameters such as back-EMF constant, resistance, and coil inductance based on magnetic field calculations. Finally, analytical results for generating performance are confirmed by comparing with finite element analysis results.