• 제목/요약/키워드: Sensor scanning

검색결과 449건 처리시간 0.029초

자동 감마 증류탑 검사 장치를 위한 방사선 계측장치 설계 (Design of radiation detection circuit for gamma column scanning)

  • 김종범;정성희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.612-615
    • /
    • 2003
  • In this paper, a design of radiation detector for gamma column scanner is introduced. Distillation column is important unit in Petro-chemical industries, and its on-line diagnose is very important. To get density profile measured by the radiation transmitted through column is well method for on-line diagnose as gamma scanning. For this purpose radiation detection circuit, radiation source and mechanical system for moving source and detector are required. Conventional radiation detection circuit for this application is sensitive to electric noise because of interface between the radiation circuit and the controller for mechanical system. The radiation detection system introduced here is using loop coil instead of slip ring to remove contact noise. Radiation detection system designed here for gamma scanning consist of BGO detector, high voltage circuit, PHA circuit and FSK modem. The BGO detector is used as radiation sensor, high voltage circuit and peak height analysis circuit is essential to process the signal generated from BGO detector. Micro controller convert measured data into ASCII data. FSK modem transmit ASCII data. Transmitted ASCH data is picked up in antenna coil and processed for combined function with mechanical system. This method gives good result by isolating the controlling circuit of mechanical system from radiation detecting circuit which is sensitive to noise.

  • PDF

불소 표면 개질 고분자 분리막의 제조와 노블가스 분리특성 (Fabrication of Fluorinated Polymeric Membranes and Their Noble Gas Separation Properties)

  • 김기범;윤국로
    • 공업화학
    • /
    • 제21권4호
    • /
    • pp.475-478
    • /
    • 2010
  • 불소화 반응을 통하여 PDMS을 질소 분위기 하에서 $50{\sim}2000\;{\mu}mol/mol$ 농도의 불소 가스($F_2$)를 사용하여 직접적인 방법으로 복합막 표면개질을 하였고 이를 OM (Optical Microscope), AFM (Atomic Force Microscope), SEM (Scanning electron microscope), FT-IR (Fourier transform infrared spectroscopy)을 측정하여 막 표면을 연구하였고 GC (Gas chromatography)로 혼합 노블가스의 기체 거동을 조사하였다. 다양한 노블 혼합 가스를 사용하여 표면 개질된 PDMS 멤브레인의 선택도가 50% 향상 되었다.

Potential Dependence of Electrochemical Etching Reaction of Si(111) Surface in a Fluoride Solution Studied by Electrochemical and Scanning Tunneling Microscopic Techniques

  • Bae, Sang-Eun;Youn, Young-Sang;Lee, Chi-Woo
    • Journal of Electrochemical Science and Technology
    • /
    • 제11권4호
    • /
    • pp.330-335
    • /
    • 2020
  • Silicon surface nanostructures, which can be easily prepared by electrochemical etching, have attracted considerable attention because of its useful physical properties that facilitate application in diverse fields. In this work, electrochemical and electrochemical-scanning tunneling microscopic (EC-STM) techniques were employed to study the evolution of surface morphology during the electrochemical etching of Si(111)-H in a fluoride solution. The results exhibited that silicon oxide of the Si(111) surface was entirely stripped and then the surface became hydrogen terminated, atomically flat, and anisotropic in the fluoride solution during chemical etching. At the potential more negative than the flat band one, the surface had a tendency to be eroded very slowly, whereas the steps of the terrace were not only etched quickly but the triangular pits also deepened on anodic potentials. These results provided information on the conditions required for the preparation of porous nanostructures on the Si(111) surface, which may be applicable for sensor (or device) preparation (Nanotechnology and Functional Materials for Engineers, Elsevier 2017, pp. 67-91).

영상처리를 이용한 Mark 판독 기법에 관한 연구 (A Study on the Mark Reader Using the Image Processing)

  • 김승호;김범진;이용구;노도환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.83-83
    • /
    • 2000
  • Recently, Vision system has being used all around industry. Sensor systems are used for Mark Reader, for example, optical scanning is proximity sensor system, have many disadvantages, such as, lacking user interface and difficulty to store original specimens. In contrast with this, Vision systems for Mark Reader has many advantages, including function conversion to achieve other work, high accuracy, high speed, etc. In this thesis, we have researched the development of Mark Reader by using a Vision system. The processing course of this s)'stem is consist to Image Pre-Processing such as noise reduction, edge detection, threshold processing. And then, we have carried out camera calibration to calibrate images which are acquired from camera. After searching for reference point within scanning area(60pixe1${\times}$30pixe1), we have calculated points crossing by using line equations. And then, we decide to each ROI(region of interest) which are expressed by four points. Next we have converted absolute coordinate into relative coordinate for analysis a translation component. Finally we carry out Mark Reading with images classified by six patterns. As a result of experiment which follows the algorithm has proposed, we have get error within 0.5% from total image.

  • PDF

RGB-D 센서 및 3D Virtual Clothing CAD활용에 의한 패션소재의 동적표현 시스템에 대한 연구 (A Study on the Dynamic Expression of Fabrics based on RGB-D Sensor and 3D Virtual Clothing CAD System)

  • 이지은;김슬기;김종준
    • 패션비즈니스
    • /
    • 제17권1호
    • /
    • pp.30-41
    • /
    • 2013
  • Augmented reality techniques have been increasingly employed in the textile and fashion industry as well as computer graphics sectors. Three-dimensional virtual clothing CAD systems have also been widely used in the textile industries and academic institutes. Motion tracking techniques are grafted together in the 3D and augmented reality techniques in order to develop the virtual three-dimensional clothing and fitting systems in the fashion and textile industry sectors. In this study, three-dimensional virtual clothing sample has been prepared using a 3D virtual clothing CAD along with a 3D scanning and reconstruction system. Motion of the user has been captured through an RGB-D sensor system, and the virtual clothing fitted on the user's body is allowed to move along with the captured motion flow of the user. Acutal fabric specimens are selected for the material characterization. This study is a primary step toward building a comprehensive system for the user to experience interactively virtual clothing under real environment.

Fabrication of nanoporous gold thin films on glass substrates for amperometric detection of aniline

  • Lee, Keon-U;Kim, Sang Hoon;Shin, Hyung-Joon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.354.1-354.1
    • /
    • 2016
  • Nanoporous gold (NPG) is a very promising material in various fields such as sensor, actuator, and catalysis because of its high surface to volume ratio and conducting nature. In this study, we fabricated a NPG based amperometric sensor on a glass substrate by means of co-sputtering of Au and Si. During the sputtering process, we found the optimum conditions for heat treatment to reduce the residual stress and to improve adhesion between NPG films and the glass substrate. Subsequently, Si was selectively etched from Au-Si alloy by KOH solution, which forms nanoporous structures. Scanning electron microscopy (SEM) and auger electron spectroscopy (AES) were used to estimate the structure of NPG films and their composition. By employing appropriate heat treatments, we could make very stable NPG films. We tested the performance of NPG sensor with aniline molecules, which shows high sensitivity for sensing low concentration of aniline.

  • PDF

감각귀환형 기능적 전기자극 시스템(SEFES)을 위한 발압력 분포 계측시스템의 개발 (Development of Measurement Systems of Foot Pressure Distribution for Sensory-Feedback type FES System(SEFES))

  • 김주명;김양영;양경모;고수복;정동명
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 춘계학술대회
    • /
    • pp.88-91
    • /
    • 1994
  • We develope a assistant system of foot pressure distribution for improvement gait Pattern, adapted working speed, and minimitation of muscle fatigue of the sensory feedback type FES system(SEFES). This measurement system consist of mat type pressure sensor with piezo electric films. The pressure data signal multiflexed input scanning method processed A/D conversion after two step amplify and integrate. Matrix sensor interface to PC for pseudo color display by level of Pressure distribution data. This measurement system clinically evaluated in hemiplegic patients. It has produced acceptable results with optimal location of the food sensor's pressure point and avoid the muscle fatigue.

  • PDF

초음파의 다중 반사 특성을 이용한 표식 모델 및 분리 (Modeling and Target Classification Using Multiple Reflections of Sonar)

  • 권인소;이왕헌
    • 제어로봇시스템학회논문지
    • /
    • 제10권9호
    • /
    • pp.779-784
    • /
    • 2004
  • This paper describes a sonic polygonal multiple reflection range sensor (SPMRS), which uses multiple reflection properties usually ignored in ultrasonic sensors as disturbances or noises. Targets such as a plane, corner, edge, or cylinder in indoor environments can easily be detected by the multiple reflection patterns obtained with a SPMRS system. Target classification and feature data extraction, such as distance and azimuth to the target, are computed simultaneously by considering the geometrical relationships between the detected targets, and finally the environment model is generated by refining the detected targets. In addition, the narrow field of view of a sonar range sensor is increased and the scanning time is reduced by active motion of the SPMRS stepping servomechanism.

H2S Gas Sensing Properties of CuO Nanotubes

  • Kang, Wooseung;Park, Sunghoon
    • Applied Science and Convergence Technology
    • /
    • 제23권6호
    • /
    • pp.392-397
    • /
    • 2014
  • CuO nanotubes are synthesized using $TeO_2$ nanorod templates for application to $H_2S$ gas sensors. $TeO_2$ nanorod templates were synthesized by using the VS method through thermal evaporation. Scanning electron microscopy, transmission electron microscopy and X-ray diffraction showed that the synthesized nanotubes were monoclinic-structured polycrystalline CuO with diameter and wall thickness of approximately 100~300 nm and 5~10 nm, respectively. The CuO nanotube sensor showed responses of 136~325% for the $H_2S$ concentration of 0.1~5 ppm at room temperature. These response values are approximately twice as high as that of the CuO nanowire sensor for the same concentrations of $H_2S$ gas. Along with the investigation of the performance of the sensors, the mechanisms of $H_2S$ gas sensing of the CuO nanotubes are also discussed in this study.