• Title/Summary/Keyword: Section Shape Steel

Search Result 227, Processing Time 0.03 seconds

Development of Steel-Concrete Composite Lining Board using Section Shape Steel (형강을 이용한 강-콘크리트 합성복공판 기술개발)

  • Oh, Soo-Cheol;Yang, Hae-Sool
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.3
    • /
    • pp.67-75
    • /
    • 2008
  • This research is to develop the steel-concrete composite lining board using section shape steel. This lining board adopts section shape steel, rectangular pipe and H-beam, instead of roll-formed steel member commonly used in other composite lining board. Consequently, it reduces fabrication effort. Efficient section which can reduce the weight of steel of the lining board is made by placing the neutral axis of the section near the lower surface of concrete. Behavior of composite section is improved by adding bolts as shear connector. Static and fatigue tests were conducted to verify the performance of the composite lining board developed. The test results indicate that serviceability as well as safety of the lining board developed is secured with good margin and reduction of steel weight can be made about 27% compared with other composite lining boards.

A Study on the Determination of Required Fire Protection Thickness Considering Steel Section Shape (강재단면형상을 고려한 소요 내화피복 두께 산정에 관한 연구)

  • Kim, Hae-Soo;Kang, Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5910-5916
    • /
    • 2011
  • Surface area of the steel member exposed to fire differs according to type and size of the section and the kind of the member, which shows a big difference in the temperature rise of the steel by fire. The section factor ($H_p$/A) is determined by factors such as type, size, and member of the steel and type of the fire protection material, and it is the criteria in determining thickness of the fire protection material. This study showed that the size of the steel increase regardless of the steel type, the section factor decrease. In the results on fire protection thickness of the steel according to the section factor, the efficiency of 1 hour fire protection was lower from 30 to 50% than the criteria. And there is the member, which have the thickness lower the minimum 27% in 2 hour fire protection, but it generally approached in the criteria. In case of H-shape steel, the efficiency of 3 hour fire protection was suitable for the criteria, but rectangular hollow steel section and circular hollow steel section were higher (5.0-17.5%) than the criteria.

Shear strength and shear behaviour of H-beam and cruciform-shaped steel sections for concrete-encased composite columns

  • Keng-Ta Lin;Cheng-Cheng Chen
    • Steel and Composite Structures
    • /
    • v.47 no.3
    • /
    • pp.423-436
    • /
    • 2023
  • In this research, we tested 10 simply supported concrete-encased composite columns under monotonic eccentric loads and investigated their shear behaviour. The specimens tested were two reinforced concrete specimens, three steel-reinforced concrete (SRC) specimens with an H-shaped steel section (also called a beam section), and five SRC specimens with a cruciform-shaped steel section (also called a column section). The experimental variables included the transverse steel shape's depth and the longitudinal steel flange's width. Experimental observations indicated the following. (1) The ultimate load-carrying capacity was controlled by web compression failure, defined as a situation where the concrete within the diagonal strut's upper end was crushed. (2) The composite effect was strong before the crushing of the concrete outside the steel shape. (3) We adjusted the softened strut-and-tie SRC (SST-SRC) model to yield more accurate strength predictions than those obtained using the strength superposition method. (4) The MSST-SRC model can more reasonably predict shear strength at an initial concrete softening load point. The rationality of the MSST-SRC model was inferred by experimentally observing shear behaviour, including concrete crushing and the point of sharp variation in the shear strain.

Shear behavior of steel reinforced concrete shallow floor beam: Experimental and theoretical study

  • Chen, Yang;Ren, Chong;Yuan, Yuqing;Yang, Yong
    • Steel and Composite Structures
    • /
    • v.44 no.5
    • /
    • pp.677-684
    • /
    • 2022
  • This paper reports experimental investigation on shear behavior of steel reinforced concrete (SRC) shallow floor beam, where the steel shape is embedded in concrete and the high strength bolts are used to transfer the shear force along the interface between the steel shape and concrete. Six specimens were conducted aiming to provide information on shear performance and explore the shear bearing capacity of SRC shallow floor beams. The effects of the height of concrete slab, the size and the type of the steel section on shear performance of beams were also analyzed in the test. Based on the strut-and-tie model, the shear strength of the SRC shallow floor beam was proposed. Experimental results showed that composite shallow floor beam exhibited satisfactory composite behavior and all of the specimen failed in shear failure. The shear bearing capacity increased with the increasing of height of concrete slab and the size of steel shape, and the bearing capacities of beam specimens with castellated steel shape was slightly lower than those of specimens with H-shaped steel section. Furthermore, the calculations for evaluating the shear bearing capacity of SRC shallow floor beam were verified to be reasonable.

Flexural Capacity Evaluation of High-strength New-shape Composite Pile (S-Pile) for the Soldier Pile in the C.I.P Method (주열식공법 엄지말뚝을 위한 고강도 신형상 합성파일 (S-Pile)의 휨성능 평가)

  • Lee, Kyung-koo;Kim, Dae-Hee;Joo, Eun-Hee;Kim, Young-Gi;Kim, Bong-Chan;Lee, Ji-Hoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.185-186
    • /
    • 2021
  • In Korea, many buildings are built with underground spaces and cast-in-place pile method is mostly applied in the temporary retaining walls for the underground space construction. A H-shaped steel section is generally embedded in the soldier pile in the C.I.P method. In this study, a new and economical section with high strength steel replacing the H-shaped section was proposed and its flexural capacity was evaluated experimentally. The new section is the concrete-filled composite section with pentagonal thin plate and thick flange plate. Test results showed that the proposed section has an excellent flexural strength and ductility.

  • PDF

A Study for Safety Evaluation of the Prestressed Hybrid Beam with T-shape Steel Member which was Developed to Build Large Span Educational Facilities (대공간 교육시설 축조를 위하여 개발된 T형 강재를 이용한 프리스트레스트 합성보의 안전성 평가를 위한 연구)

  • Lee, Kyoung-Hun;Kim, Tae-Hui
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.9 no.1
    • /
    • pp.32-40
    • /
    • 2010
  • The purpose of this study was to evaluate structural safety and economic efficiency of prestressed hybrid beam using T-shape steel member which was developed to build large span educational facilities. Hybrid beam specimens were manufactured with 16.0m long and load was uniformly distributed by 12.0kN steel hexahedrons. In this study, honeycomb beam design process was introduced to T-shape section steel beam design. Vibration condition of specimens were analyzed by Korea Building Code 2009 and AISC Steel Design Guide Series-11. As a result, the prestressed hybrid beam with T-shape steel member has about 10.4% of cost reduction effect.

An Experimental Study on the Local Buckling of Welded H-Shape Steel Beam (용접(熔接)H형강(型鋼) 보의 국부좌굴(局部挫屈)에 관한 실험적(實驗的) 연구(硏究))

  • Kim, Seok-Jung
    • Journal of Industrial Technology
    • /
    • v.1
    • /
    • pp.9-16
    • /
    • 1981
  • In the steel Structural design, buckling is the main factor to determine size, particularly in compression member. Buckling may sometimes occur in the form of wrinkles in thin elements, such as webs, flanges, and other parts that make up a section. This phenomenon is called local buckling. The strength of the steel and the rigidity of the frame are considerably deteriorated by the local buckling. The specimens used for this experiments, H-Shape Steel beams composed by fillet-welding, are dessified classified into two groups, ie one for web test and another for flange fest. The aim of this study is to define the influences by the local bucking on the vesisting forces, deformation and the phenomena of the internal forces in the section, and to collect the basic data for design of steel beams.

  • PDF

Inelastic Behavior of the SRC Column (SRC 합성교각의 비탄성 거동)

  • Jung, In-Keun;Min, Jin;Shim, Chang-Su;Chung, Young-Soo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.300-307
    • /
    • 2005
  • Steel Reinforced Concrete (SRC) composite column has several advantage such as excellent durability, rapid construction, reduction of column section. Due to these aspect, applications of SRC columns to bridge piers are continuously increasing. For the design of relatively large SRC columns for bridge piers, it is necessary to check the current design provisions which were based on small section having higher steel ratio. In this study, seven concrete encased composite columns were fabricated and static tests were performed. Embedded steel members were a H-shape rolled beam and a partially filled steel tube. Based on the test results, the ultimate strength according to section details and local behavior were estimated. For the analysis of inelastic behavior of the SRC column, the cracked section stiffness of the columns was evaluated and compared with calculations. The stiffness of the cracked section showed that 25% of the initial value and this stiffness reduction occurred at 85% of the ultimate load in the experiments.

  • PDF

A Study on Optimum Section of New Type Steel-Concrete Composite Beam (신형상 층고절감형 합성보의 최적단면 도출에 관한 연구)

  • Yoon, Myung-Ho;Lee, Yoon-Hee
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.3
    • /
    • pp.30-35
    • /
    • 2011
  • This study investigates the optimum section properties of newly developed steel-concrete composite beam. For that purpose we developed computer program calculating section properties. The suggested new beam section highly contribute to save inter-story height and reduce construction duration and cost compared with conventional steel works such as H-beam and column + RC slab system. But the section shape have different section modulus with upper and lower fiber because of the unsymmetric cross section. Therefore the parametric study on thickness-ratio of top and bottom flange plate is needed. In this paper the change of neutral axis and section modulus for thickness-ratio of up and down flage plate is analysed and discussed.

An Experimental Study on Flexural Strength of Composite Beam with Reduced Top Flange of Steel (상부플랜지를 감소시킨 합성보의 휨내력에 관한 실험적 연구)

  • Moon, Chan-II;Jeong, Jae-Hun;Kim, Jin-Moo;Joo, Kyong-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.3
    • /
    • pp.153-160
    • /
    • 2000
  • In simply supported composite beams, the neutral axis of the composite cross section usually is located the top flange of the steel I-shape, so that the top flange does not impart much strength to the member. This suggests that omitting the top flange entirely could be a means to lower the cost of the beam without greatly reducing the strength. The purpose of this investigation is to research flexural strength and behavior of the composite beams with reduced top flange of steel. Five specimens with H and inverted T steel section were tested. As the test results, comparison of the experimental to computed full-plastic moment, and variations of flexural strength with reduced top flange were analyzed.

  • PDF