• 제목/요약/키워드: Secondary Working

검색결과 315건 처리시간 0.023초

주서비스와 보조서비스를 갖는 시스템 설계 (A Design Problem of a System Working at Both Primary Service and Secondary Service)

  • 김성철
    • 경영과학
    • /
    • 제28권3호
    • /
    • pp.15-29
    • /
    • 2011
  • In this paper, we consider a system working at both primary service and secondary service. A server can switch between the primary service and the secondary service or it can be assigned to secondary service as a dedicated server. A service policy is characterized by the number of servers dedicated to the secondary service and a rule for switching the remaining servers between two services. The primary service system is modelled as a Markovian queueing system and the throughput is a function of the number of servers, buffer capacity, and service policy. And the secondary service system has a service level requirement strategically determined to perform the service assigned. There is a revenue obtained from throughput and costs due to servers and buffers. We study the problem of simultaneously determining the optimal total number of servers, buffers, and service policy to maximize profit of the system subject to both an expected customer waiting time constraint of the primary service and a service level constraint of the secondary service and develop an algorithm which can be successfully applied with the small number of computations.

일 지역의 진료기관에 따른 간호사의 지각된 간호조직풍토 및 직무만족도 비교;2, 3차 진료기관을 중심으로 (A Comparison of organizational climate and job satisfaction of nurses according to type of hospital;a secondary hospital and a tertiary hospital)

  • 김찬임;윤숙희
    • 간호행정학회지
    • /
    • 제9권1호
    • /
    • pp.63-73
    • /
    • 2003
  • Purpose : The purpose of this study is to analyze the comparison of organizational climate and job satisfaction of nurses between a secondary hospital and a tertiary hospital. Method : The subjects of this study were 50 nurses who were working in a secondary hospital and 50 working in a tertiary hospital. The data was collected by self-reporting questionnaires. The data were analysed using frequency, percentage, mean, standard deviation, t-test, ANOVA, Pearson's correlation coefficient, regression analysis. Result : 1) There was no statistical significance of the difference of organizational climate between a secondary hospital and a tertiary hospital. However, there was a statistical significance of the difference of job satisfaction. 2) In the organizational climate, there was a significant difference by income in a secondary hospital, and by position in a tertiary center. 3) In the job satisfaction, there was significant differences by age, marriage, position, and duration of working in a secondary hospital, otherwise. there was no significant difference in a tertiary hospital. 4) There was significant positive correlation between organizational climate and job satisfaction. Organizational climate significantly affected job satisfaction. Conclusion : It is suggested that the nursing organizational effectiveness program should be developed with reflecting on organizational characteristics that the nurses perceived.

  • PDF

GM형 맥동관 냉동기의 저온부 경사도에 따른 냉각 성능 특성 연구 (Orientation dependence of GM-type pulse tube refrigerator)

  • 고준석;김효봉;박성제;홍용주;염한길;이청수;강인수;고득용
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권3호
    • /
    • pp.48-52
    • /
    • 2012
  • This paper describes experimental study on the orientation dependence of GM-type pulse tube refrigerator with helium and neon as working gas. A pulse tube refrigerator generates refrigeration work with gas expansion by gas displacer in the pulse tube. The pulse tube is only filled with working gas and there exists secondary flow due to large temperature difference between cold-end and warm-end. The stability of secondary flow is affected by orientation of cold-head and thus cooling performance is deteriorated by gas mixing due to secondary flow. In this study, a single stage GM-type pulse tube with orifice valve as a phase control device is fabricated and tested. The fabricated pulse tube refrigerator is tested with two different working gases of helium and neon. First, optimal valve opening and operating frequency are determined with experimental results of no-load test. And then, the variation of no-load temperature as orientation angle of cold-head is measured for two different working gases. Effect of orientation dependence of cold-head as working gas is discussed with experimental results.

Influence of Working Fluids to Heat Transfer Characteristics of Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery

  • Lee, Wook-Hyun;Im, Yong-Bin;Kim, Ju-Won;Kim, Jeung-Hoon;Kim, Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.27-35
    • /
    • 2001
  • Heat transfer characteristics of a heat exchanged for low temperature waste heat recovery using oscillating capillary tube heat pipe (OCHP) were evaluated against the charging ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working a 2.6mm in outside diameter, 1.44mm in inside diameter with 101m length and 140 turns. Charging ratio of working fluid was 40% and 50%. water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and 9~27 $4kg/m^2s$, respectively. From experimental results, it was found that heat transfer performance of R-22 was higher than those of R-142b and R-290 and it was proportional to Figure of Merit for thermosyphon. As a result, it was thought that R-22 was the most reasonable working fluid of waste heat recovery for low temperature waste heat recovery.

  • PDF

저온 폐열회수용 진동세관형 히트파이프 열교환기의 작동 유체에 따른 열전달 특성 (Influence of Working Fluids to Heat Transfer Characteristics of the Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery)

  • 이욱현;임용빈;김정훈;김종수
    • 설비공학논문집
    • /
    • 제12권7호
    • /
    • pp.659-666
    • /
    • 2000
  • Heat transfer characteristics of a heat exchanger for low temperature waste heat recovery using oscillating capillary tube heat pipe were evaluated against the charge ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working fluids. The heat exchanger was composed of heat pipe with capillary tube bundles, having a 2.6mm in outer diameter, 1.4mm in inner diameter with 101m long, and 40 turns. Charge ratio of working fluid was 40% and 50%. Water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and9~27 kg /$m^2s$,, respectively. From experimental results, it was found that heat transfer performance of R-22 was higher than those of R-l42b and R-290 and it was proportional to Figure of merit for thermosyphons. As a result, it was thought that R-22 was the most suitable working fluid of waste heat recovery for low temperature waste heat recovery.

  • PDF

텍스트 유형과 작업기억이 읽기 정상 아동과 읽기 지진 아동의 텍스트 이해에 미치는 영향 (Effects of Text Types and Working Memory on Text Comprehension in Reading Normal and Reading Deficient Children)

  • 도경수;이은주
    • 인지과학
    • /
    • 제17권3호
    • /
    • pp.191-206
    • /
    • 2006
  • 언어 작업기억과 시공간 작업기억이 아동의 글 이해에 미치는 영향을 알아보기 위해 읽기 정상 아동과 읽기 지진아동들에게 두 개의 실험을 실시하였다. 실험 1에서 정상 아동에 비해 읽기 지진 아동들이 읽기 폭과 연산 폭은 작았으나 시공간 폭은 작지 않았다. 또 정상아동은 설명글과 묘사글의 이해 정도의 차이가 없었지만, 읽기 지진 아동들은 묘사글보다 설명글의 이해 정도가 낮았다. 실험 2에서는 청각 기억과제와 시각 기억과제가 글 이해에 미치는 간섭효과를 알아보았다. 정상 아동들은 설명글과 묘사글 모두에서 시각 기억과제를 할 때보다 청각 기억과제를 할 때 이해 정도가 떨어졌으나, 읽기 지진 아동들은 묘사글을 읽을 때에는 통계적으로 유의하지는 않았으나 시각 기억과제 조건에서 글 이해정도가 낮은 경향을 보였다. 이 결과는 글을 읽을 때, 특히 묘사글을 읽을 때 시공간 작업기억도 관여할 수 있으며, 이 가능성은 정상아동에게서 보다 읽기 지진 아동에게서 더 클 것으로 해석되었다.

  • PDF

저온 폐열 회수용 진동형 히트 파이프 열교환기의 성능 평가에 관한 연구 (Study on Performance Evaluation of Oscillating Heat Pipe Heat Exchanger for Low Temperature Waste Heat Recovery)

  • 안영태;이욱현;김정훈;김종수
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.368-376
    • /
    • 2001
  • Performance of heat exchanger was evaluated to heat exchanger using oscillating heat pipe for waste heat recovery of low temperature. Oscillating heat pipe used in this study was formed to the closed loop of serpentine shapes using copper tubes. Heat exchanger was formed to shell and tube type and composed of low finned tube. R-22 and R-141b were used to the working fluids of tube side and their charging ratio was 40%. And, water was used to the working fluid of shell side. As the experimental parameters, the inlet temperature difference of heating and cooling part of secondary fluid and the mass velocity of secondary fluid were used. The mass velocity of secondary fluid was changed from 90 kg/$m^2s\; to\;190 kg/m^2$s from the experimental results, heat recovery rate was linearly increased to the increment of the mass velocity of secondary fluid and the inlet temperature difference of secondary fluid. Finally, the performance of heat exchanger was evaluated by using $\varepsilon$-NTU method. It was found that NTU was about 1.5 when effectiveness was decided to 80%.

  • PDF

아민 차수에 따른 고체 흡수제의 이산화탄소 분리 특성 (Characteristics of Carbon Dioxide Separation for Solid Absorbents According to Amine Order)

  • 장현태
    • Korean Chemical Engineering Research
    • /
    • 제61권4호
    • /
    • pp.619-626
    • /
    • 2023
  • 건식 이산화탄소 분리공정에서 아민 구조체의 운전 특성을 규명하기 위하여 1차 아민과 2차 아민 구조체를 합성하였다. TSA 조건에서 1차 아민과 2차 아민 건식 포집 분리제의 분리 특성을 연구하였다. (3-Aminopropyl) triethoxysilane을 1차 아민 전구체로 가교제로 이용하여 가교 결합된 2차 아민 전구체를 합성하였다. 합성된 2차 아민 전구체를 Tetraethyl orthosilicate를 구조배양제로 사용하여 2차 아민 고체상 이산화탄소 분리제를 합성하였다. 1차 및 2차 아민 구조체의 TSA 공정조건에서 이산화탄소 분리 특성을 비교하였다. 1차 아민에 흡수된 이산화탄소 분리는 170 ℃ 이상에서 완전히 이루어지나 이산화탄소에 의하여 아민이 우레아로 전환되며, 아민기 손실이 발생되었다. 아민 손실이 낮은 130 ℃ 재생시 1차 아민 분리제의 공정 운전성능(working capacity)은 본 구조체의 경우 2% 이하로 나타났다. 2차 아민이 낮은 재생온도에서 높은 이산화탄소 분리능을 나타내었다. 이산화탄소 2% 흡수 분위기와 100% 재생분위기에서 약 6.5%의 공정 운전 성능을 예측할 수 있었다.

인접구조물 하부통과에 따른 굴착공법에 대한 고찰 (A Study on Excavation Method According to Passage under Adjacent Structure)

  • 김태현;고진석;조영동
    • 화약ㆍ발파
    • /
    • 제23권1호
    • /
    • pp.31-39
    • /
    • 2005
  • 본 연구는 중앙선(덕소-원주간) 복선전철 터널공사론 기초로 한 것으로 주변 보안물건에 대한 피해가 발생되지 않도록 시험발파를 통한 발파 환경 영향권 분석을 실시하고, 그 결과를 상호 비교, 분석하여 안전하고 효율적인 공사가 수행될 수 있도록 적합한 대체 굴착공법의 적용에 대하여 연구하였다. 시험발파를 통해 제시된 대체굴착공법을 이용하여 더 안전하고 효과적인 작업을 수행한 수 있었으며, 무진동 구간은 일반적으로 2차 작업이 병행되므로 breaker 작업에 의한 진동이 지속적으로 발생되어 연구지역의 경우 적용이 사실상 어렵다고 판단됨에 따라 선대구경 수평보링 공법+라인드릴링 공법+다분할 미진동 소발파 공법을 적용함으로써 발파진동 기준치 이내의 수준으로 굴착작업이 가능하였다.

Visualization of RNA Secondary Structures

  • Han, Kyung-Sook
    • 한국생물정보학회:학술대회논문집
    • /
    • 한국생물정보시스템생물학회 2000년도 International Symposium on Bioinformatics
    • /
    • pp.35-38
    • /
    • 2000
  • An early step toward evaluating a predicted RNA secondary structure is to visualize the predicted structure in graphical form. This talk will present an algorithm for efficiently drawing RNA secondary structures. The algorithm represents the direction and space for a structural element using vector and vector space, and generates nearly overlap-free polygonal displays. The algorithm and a graphical user interface have been implemented in a working program called VizQFolder on IBM PC compatibles.

  • PDF