Influence of Working Fluids to Heat Transfer Characteristics of Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery
- Lee, Wook-Hyun (LG Electronics) ;
- Im, Yong-Bin (Graduate School, Pukyong National University) ;
- Kim, Ju-Won (Graduate School, Pukyong National University) ;
- Kim, Jeung-Hoon (School of Mechanical Engineering, Pukyong Natonal University) ;
- Kim, Jong-Soo (School of Mechanical Engineering, Pukyong Natonal University)
- Published : 2001.09.01
Abstract
Heat transfer characteristics of a heat exchanged for low temperature waste heat recovery using oscillating capillary tube heat pipe (OCHP) were evaluated against the charging ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working a 2.6mm in outside diameter, 1.44mm in inside diameter with 101m length and 140 turns. Charging ratio of working fluid was 40% and 50%. water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and 9~27