An Analysis of Shortened Experiments for Environmental Chamber

  • Choi, Sang-Hyun (Department of Mechanical Engineering, Yeungnam University) ;
  • Bai, Cheol-Ho (Department of Mechanical Engineering, Yeungnam University) ;
  • Chung, Mo (Department of Mechanical Engineering, Yeungnam University) ;
  • Kyung, Nam-Bo (Korea Institute of Energy Research) ;
  • Suh, Hang-Suk (Korea Institute of Energy Research)
  • Published : 2001.09.01

Abstract

Environmental chamber (EC) is an experimental facility used to analyze the characteristics of thermal response of testing objects by the artificial control of weather conditions. The EC in KIFR can simulate the weather conditions by the control of temperature, humidity, and solar radiation. A two-storied testing building is located inside EC. For the exact thermal response analysis of testing building, monthly or yearly scheduled operations are necessary. Although this long term operation gives the exact experimental data, it requires a high operational cost, long duration, and lots of manpower. Therefore it is necessary to perform the shortened experiments without sacrificing the validity of the obtained results. Since the characteristics of thermal response from the shortened experiments are different from the full time results, the analytical method to analyze the thermal response from the shortened experiments to estimate a full times results is developed in this study The thermal response of testing building is performed using commercial software TRNSYS.

Keywords