• Title/Summary/Keyword: Secondary Working

Search Result 315, Processing Time 0.021 seconds

A Design Problem of a System Working at Both Primary Service and Secondary Service (주서비스와 보조서비스를 갖는 시스템 설계)

  • Kim, Sung-Chul
    • Korean Management Science Review
    • /
    • v.28 no.3
    • /
    • pp.15-29
    • /
    • 2011
  • In this paper, we consider a system working at both primary service and secondary service. A server can switch between the primary service and the secondary service or it can be assigned to secondary service as a dedicated server. A service policy is characterized by the number of servers dedicated to the secondary service and a rule for switching the remaining servers between two services. The primary service system is modelled as a Markovian queueing system and the throughput is a function of the number of servers, buffer capacity, and service policy. And the secondary service system has a service level requirement strategically determined to perform the service assigned. There is a revenue obtained from throughput and costs due to servers and buffers. We study the problem of simultaneously determining the optimal total number of servers, buffers, and service policy to maximize profit of the system subject to both an expected customer waiting time constraint of the primary service and a service level constraint of the secondary service and develop an algorithm which can be successfully applied with the small number of computations.

A Comparison of organizational climate and job satisfaction of nurses according to type of hospital;a secondary hospital and a tertiary hospital (일 지역의 진료기관에 따른 간호사의 지각된 간호조직풍토 및 직무만족도 비교;2, 3차 진료기관을 중심으로)

  • Kim, Chan-Im;Yoon, Sook-Hee
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.9 no.1
    • /
    • pp.63-73
    • /
    • 2003
  • Purpose : The purpose of this study is to analyze the comparison of organizational climate and job satisfaction of nurses between a secondary hospital and a tertiary hospital. Method : The subjects of this study were 50 nurses who were working in a secondary hospital and 50 working in a tertiary hospital. The data was collected by self-reporting questionnaires. The data were analysed using frequency, percentage, mean, standard deviation, t-test, ANOVA, Pearson's correlation coefficient, regression analysis. Result : 1) There was no statistical significance of the difference of organizational climate between a secondary hospital and a tertiary hospital. However, there was a statistical significance of the difference of job satisfaction. 2) In the organizational climate, there was a significant difference by income in a secondary hospital, and by position in a tertiary center. 3) In the job satisfaction, there was significant differences by age, marriage, position, and duration of working in a secondary hospital, otherwise. there was no significant difference in a tertiary hospital. 4) There was significant positive correlation between organizational climate and job satisfaction. Organizational climate significantly affected job satisfaction. Conclusion : It is suggested that the nursing organizational effectiveness program should be developed with reflecting on organizational characteristics that the nurses perceived.

  • PDF

Orientation dependence of GM-type pulse tube refrigerator (GM형 맥동관 냉동기의 저온부 경사도에 따른 냉각 성능 특성 연구)

  • Ko, Jun-Seok;Kim, Hyo-Bong;Park, Seong-Je;Hong, Yong-Ju;Yeom, Han-Kil;Lee, Chung-Soo;Kang, In-Su;Koh, Deuk-Yong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.48-52
    • /
    • 2012
  • This paper describes experimental study on the orientation dependence of GM-type pulse tube refrigerator with helium and neon as working gas. A pulse tube refrigerator generates refrigeration work with gas expansion by gas displacer in the pulse tube. The pulse tube is only filled with working gas and there exists secondary flow due to large temperature difference between cold-end and warm-end. The stability of secondary flow is affected by orientation of cold-head and thus cooling performance is deteriorated by gas mixing due to secondary flow. In this study, a single stage GM-type pulse tube with orifice valve as a phase control device is fabricated and tested. The fabricated pulse tube refrigerator is tested with two different working gases of helium and neon. First, optimal valve opening and operating frequency are determined with experimental results of no-load test. And then, the variation of no-load temperature as orientation angle of cold-head is measured for two different working gases. Effect of orientation dependence of cold-head as working gas is discussed with experimental results.

Influence of Working Fluids to Heat Transfer Characteristics of Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery

  • Lee, Wook-Hyun;Im, Yong-Bin;Kim, Ju-Won;Kim, Jeung-Hoon;Kim, Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.3
    • /
    • pp.27-35
    • /
    • 2001
  • Heat transfer characteristics of a heat exchanged for low temperature waste heat recovery using oscillating capillary tube heat pipe (OCHP) were evaluated against the charging ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working a 2.6mm in outside diameter, 1.44mm in inside diameter with 101m length and 140 turns. Charging ratio of working fluid was 40% and 50%. water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and 9~27 $4kg/m^2s$, respectively. From experimental results, it was found that heat transfer performance of R-22 was higher than those of R-142b and R-290 and it was proportional to Figure of Merit for thermosyphon. As a result, it was thought that R-22 was the most reasonable working fluid of waste heat recovery for low temperature waste heat recovery.

  • PDF

Influence of Working Fluids to Heat Transfer Characteristics of the Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery (저온 폐열회수용 진동세관형 히트파이프 열교환기의 작동 유체에 따른 열전달 특성)

  • 이욱현;임용빈;김정훈;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.7
    • /
    • pp.659-666
    • /
    • 2000
  • Heat transfer characteristics of a heat exchanger for low temperature waste heat recovery using oscillating capillary tube heat pipe were evaluated against the charge ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working fluids. The heat exchanger was composed of heat pipe with capillary tube bundles, having a 2.6mm in outer diameter, 1.4mm in inner diameter with 101m long, and 40 turns. Charge ratio of working fluid was 40% and 50%. Water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and9~27 kg /$m^2s$,, respectively. From experimental results, it was found that heat transfer performance of R-22 was higher than those of R-l42b and R-290 and it was proportional to Figure of merit for thermosyphons. As a result, it was thought that R-22 was the most suitable working fluid of waste heat recovery for low temperature waste heat recovery.

  • PDF

Effects of Text Types and Working Memory on Text Comprehension in Reading Normal and Reading Deficient Children (텍스트 유형과 작업기억이 읽기 정상 아동과 읽기 지진 아동의 텍스트 이해에 미치는 영향)

  • Do, Kyung-Soo;Lee, Eun-Ju
    • Korean Journal of Cognitive Science
    • /
    • v.17 no.3
    • /
    • pp.191-206
    • /
    • 2006
  • Two experiments were conducted to investigate the effects of verbal working memory and the spatial working memory on children's text comprehension. The reading span and the operation span of the reading deficient children were smaller than that of the reading normal children, but the two groups did not differ in the visual span. Reading deficient children got lower score in the comprehension tests than reading normal children, and the difference was larger for the expository text than the narrative text. The involvement of visual working memory in reading narrative texts were more directly tested in Experiment 2 by asking the children do a secondary memory task before they answered the comprehension test. Reading normal children suffered more under auditory secondary memory condition for both narrative and expository texts, whereas reading deficient children suffered under visual secondary memory condition for narrative texts as well. The results of the two experiments suggested that the spatial working memory can be involved in text comprehension process, especially with reading deficient children.

  • PDF

Study on Performance Evaluation of Oscillating Heat Pipe Heat Exchanger for Low Temperature Waste Heat Recovery (저온 폐열 회수용 진동형 히트 파이프 열교환기의 성능 평가에 관한 연구)

  • 안영태;이욱현;김정훈;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.368-376
    • /
    • 2001
  • Performance of heat exchanger was evaluated to heat exchanger using oscillating heat pipe for waste heat recovery of low temperature. Oscillating heat pipe used in this study was formed to the closed loop of serpentine shapes using copper tubes. Heat exchanger was formed to shell and tube type and composed of low finned tube. R-22 and R-141b were used to the working fluids of tube side and their charging ratio was 40%. And, water was used to the working fluid of shell side. As the experimental parameters, the inlet temperature difference of heating and cooling part of secondary fluid and the mass velocity of secondary fluid were used. The mass velocity of secondary fluid was changed from 90 kg/$m^2s\; to\;190 kg/m^2$s from the experimental results, heat recovery rate was linearly increased to the increment of the mass velocity of secondary fluid and the inlet temperature difference of secondary fluid. Finally, the performance of heat exchanger was evaluated by using $\varepsilon$-NTU method. It was found that NTU was about 1.5 when effectiveness was decided to 80%.

  • PDF

Characteristics of Carbon Dioxide Separation for Solid Absorbents According to Amine Order (아민 차수에 따른 고체 흡수제의 이산화탄소 분리 특성)

  • Hyun Tae Jang
    • Korean Chemical Engineering Research
    • /
    • v.61 no.4
    • /
    • pp.619-626
    • /
    • 2023
  • Primary and secondary amine-based sorbents were synthesized to investigate the operation capacity for the carbon dioxide separation TSA process. (3-Aminopropyl) triethoxysilane was used as a primary amine precursor as a crosslinking agent to synthesize a secondary amine precursor in which amine groups were crosslinked with a crosslinking agent. Carbon dioxide absorbed by primary amines is completely separated above 170 ℃. The working capacity of the primary amine absorbent was less than 2% when regenerated at 130℃. The secondary amine absorbent has a higher carbon dioxide separation capacity at a lower regeneration temperature than the primary amine absorbent. The secondary amine absorbent could predict process operation performance of about 6.5% with 2% carbon dioxide absorption and 100% carbon dioxide regeneration conditions. Therefore, it was found that the working capacity of the secondary amine absorbent was higher than that of the primary amine.

A Study on Excavation Method According to Passage under Adjacent Structure (인접구조물 하부통과에 따른 굴착공법에 대한 고찰)

  • Kim Tai-Hyun;Ko Chin-Surk;Cho Young-Dong
    • Explosives and Blasting
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2005
  • This study is based on the reseach about conte. track$(Dugso\~wonju)$ double line electric railway tunnel. Authors conducted test blasting to examine the effect of blasting pollution. To be conducted safe and effective work by using this result studies sailable substitution excavation method. No-vibration section generates continuously the vibration of breaker working to go abreast necessarily secondary fragmentation working and according to judging that application is actually difficult in case of the condition of study site, the period of construction, the cost of construction, the efficiency of construction, pre-heavy caliber horizontally boring working + line drilling method + vibration control secondary blasting method excavation working is possible from level within blast vibration standard.

Visualization of RNA Secondary Structures

  • Han, Kyung-Sook
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2000.11a
    • /
    • pp.35-38
    • /
    • 2000
  • An early step toward evaluating a predicted RNA secondary structure is to visualize the predicted structure in graphical form. This talk will present an algorithm for efficiently drawing RNA secondary structures. The algorithm represents the direction and space for a structural element using vector and vector space, and generates nearly overlap-free polygonal displays. The algorithm and a graphical user interface have been implemented in a working program called VizQFolder on IBM PC compatibles.

  • PDF