• Title/Summary/Keyword: Secondary System

Search Result 3,342, Processing Time 0.041 seconds

Characterization of Secondary Exposure to Chemicals and Indoor Air Quality in Fire Station (소방서 실내공간의 화학적 유해인자 2차노출과 실내공기질 특성)

  • Kim, Soo Jin;Ham, Seunghon;Jeon, Jeong Seok;Kim, Won
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.140-151
    • /
    • 2019
  • It is to assess the indoor air quality of the chemical hazardous materials exposed to the fire after firefighters returned to the fire scene. The research subject randomly selected four fire stations located in Seoul, Korea. Two fire stations were set up as control groups after the return of the firefighting activities at the actual fire scene, and two other fire stations were set up as control groups to measure the air quality of the room at normal levels regardless of the action. We conducted 24-hour monitoring for all fire accidents that occurred in Seoul Metropolitan using fire safety map computer system. Also, indoor air quality was measured immediately after homecoming if the experiment group was to be dispatched due to an accident of intermediate or larger scale. 11 hazardous substance items such as fine dust, formaldehyde, volatile organic compounds, PAH, VCM, acidity, asbestos, CO2, NO2, O3 were measured according to the process test method. Three of 11 types of harmful substances exceeded domestic and foreign standards, and one of them was found to be close to foreign standards. In particular, total volatile organic compounds, carbon dioxide and sulfuric acids were 2.5 times, 2.2 times and 1.1 times higher than the standard. Also, for formaldehyde and sulfuric acid, it was measured higher in the control group than in the case group. This findings could be used in policies to improve indoor air quality in the fire station of the Seoul Metropolitan Government.

Simulation of Remote Field Scanner for Defect Evaluation of Water Wall Tube Within the Fluidized Bed Boiler (유동층보일러 수냉벽튜브 결함평가를 위한 원격자장 스캐너 시뮬레이션에 관한 연구)

  • Gil, Doo-Song;Jung, Gye-Jo;Seo, Jung-Seok;Kim, Hak-Joon;Kwon, Chan-Wool
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.145-150
    • /
    • 2020
  • Water wall tube is one of the major factors consisting of a fluidized bed boiler and it plays very important role for the generation of electricity within the boiler. But these water wall tubes within the fluidized bed boiler are subject to the ware and corrosion caused by the high temperature gas and the flowing medium. If water leak is occurred, the secondary damage by the water leak will occur. As a result of that, the power generation efficiency decreases noticeably. Therefore, the maintenance of the water wall tube is very important. In this study, we designed a exciter sensor based on simulation and composed a remote field eddy current system for the defect evaluation of the outer water wall tube. Starting from the shape design of exciter, we conducted simulations for various design factors such as the water wall tube size, material, frequency, lift-off and so on. Based on the results, we designed the optimum exciter sensor for the water wall tube test within the fluidized bed boiler.

Comparison of Soil Chemistry and Environmental Characteristics of Organic Paddy and Conventional Paddy Before Basal Fertilizer Application (기비전 유기논과 관행논의 토양 화학 및 환경 특성 비교)

  • Park, Jeong-Soo;Wang, Long;Kang, Ku;Gu, Bon-Wun;Kim, Han-Joong;Hong, Seong-Gu;Hong, Seung-Gil;Park, Seong-Jik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.6
    • /
    • pp.47-57
    • /
    • 2015
  • Organic farming system has been considered environmental friendly and sustainable agricultural practice. However, the influence of organic farming on soil quality and environment is not well informed and controversial. We sampled and analyzed 0~15 cm and 15~30 cm depth soils of organic and conventional paddy fields in Yongin and Anseong. The electric conductivity and organic matter content of organic paddy soil were significantly less (p = 0.0097, 0.0067, respectively) than those of conventional paddy soil. Available phosphate and total phosphorus in 0~15 cm depth of organic paddy soil were $211.1{\pm}135.3$, $872.4{\pm}286.3mg/kg$, respectively, less than those of conventional paddy soil. Available phosphate amount in conventional paddy was $358.8{\pm}246.7mg/kg$, which is higher than 300 mg/kg that can cause secondary environmental contamination by runoff. The amount of total nitrogen in organic paddy soil was less than that in conventional paddy while their difference was not significant. The concentration of the heavy metals in organic paddy soil was also lower than that in conventional paddy soil but their difference was not statistically significant. Our findings demonstrate that electric conductivity, organic matter, nutrients, and heavy metals in organic paddy soil were less than those in conventional paddy soil. However, additional monitoring of soil properties for longer period is necessary to certify such a conclusion.

The bifunctional effect of propofol on thromboxane agonist (U46619)-induced vasoconstriction in isolated human pulmonary artery

  • Hao, Ning;Wang, Zhaojun;Kuang, Sujuan;Zhang, Guangyan;Deng, Chunyu;Ma, Jue;Cui, Jianxiu
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.21 no.6
    • /
    • pp.591-598
    • /
    • 2017
  • Propofol is known to cause vasorelaxation of several systemic vascular beds. However, its effect on the pulmonary vasculature remains controversial. In the present study, we investigated the effects of propofol on human pulmonary arteries obtained from patients who had undergone surgery. Arterial rings were mounted in a Multi-Myograph system for measurement of isometric forces. U46619 was used to induce sustained contraction of the intrapulmonary arteries, and propofol was then applied (in increments from $10-300{\mu}m$). Arteries denuded of endothelium, preincubated or not with indomethacin, were used to investigate the effects of propofol on isolated arteries. Propofol exhibited a bifunctional effect on isolated human pulmonary arteries contracted by U46619, evoking constriction at low concentrations ($10-100{\mu}m$) followed by secondary relaxation (at $100-300{\mu}m$). The extent of constriction induced by propofol was higher in an endothelium-denuded group than in an endothelium-intact group. Preincubation with indomethacin abolished constriction and potentiated relaxation. The maximal relaxation was greater in the endothelium-intact than the endothelium-denuded group. Propofol also suppressed $CaCl_2$-induced constriction in the 60 mM $K^+$-containing $Ca^{2+}$-free solution in a dose-dependent manner. Fluorescent imaging of $Ca^{2+}$ using fluo-4 showed that a 10 min incubation with propofol ($10-300{\mu}m$) inhibited the $Ca^{2+}$ influx into human pulmonary arterial smooth muscle cells induced by a 60 mM $K^+$-containing $Ca^{2+}$-free solution. In conclusion, propofol-induced arterial constriction appears to involve prostaglandin production by cyclooxygenase in pulmonary artery smooth muscle cells and the relaxation depends in part on endothelial function, principally on the inhibition of calcium influx through L-type voltage-operated calcium channels.

Functions and Roles of Musical Vocal Coach (뮤지컬 보컬 코치의 기능과 역할)

  • Lim, Ji-hyun;Min, Kyung-won
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.1
    • /
    • pp.642-650
    • /
    • 2018
  • Musical is produced by multiple specialists including director, writer, composer, lyricist, choreographer, music director, actors/actresses and so on. For the success of one musical, all the people with different background should demonstrate their creativities. The basic frame of a work is made by writer, composer and lyricist first unless it is a licensed musical. They are called as Creative Team, and also director, choreographer, actors/actresses and staff are called as Production Team. Both teams are collectively called as Creative Staff. Then, the secondary creative staff members may participate in the work depending on the production size, and each team can consist of the members such as music director, stage designer, sound designer and so on. The staff related to music in Creative Team of the musical is developed with the initiation from the music supervisor who decides the musical color and genre of the work, the fragmentation and the specialization. However, composer or music director takes these roles in charge in Korea. This study aims to establish the roles and concept of vocal coach according to the fragmentation of working process and to investigate their roles and needs in the domestic musical industry upon case analysis of musical production processes in overseas. The common things and differences in the roles and the functions between ordinary voice teachers and musical vocal coaches were analyzed and the cases of vocal coach in the Korean musicals were reviewed by the interviews. In addition, creative team system was reviewed in the Korean musicals.

A Study on Watertightness Improvement of Hybrid Method Using Polyvinyl Acetate(PVAc) (폴리비닐아세테이트(PVAc)를 이용한 복합공법의 수밀성능 향상에 관한 연구)

  • Ryou, Jae Suk;Song, Il Hyun;Lee, Yong Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.18-24
    • /
    • 2012
  • In this study, hybrid method using polyvinyl acetate (PVAc) which has a strong adhesion and flexibility in which acrylic copolymer chemical-reaction reacts with cement, and is eco-friendly, is to improve the watertightness. The hybrid method is applied applied primarily waterproof stuff comprising silicate system and secondary mortar mixed with PVAc on the concrete surface. And then, in order to evaluate the performance, the properties of bond strength and amount of water absorption were measured. Based on the above experiments, mock-up specimens for field application were fabricated, and then the properties were evaluated as laboratory experiments. As the results, specimens cast from hybrid method using PVAc showed the best results on watertightness and bond strength. And also, with respect to experiment of mock-up specimens, the properties were in agreement with laboratory results. Especially, it could know that PVAc has strengthening effect from the results of the compressive strength. Due to outstanding results of carbonation depth and resistance to chloride ion penetration, it may be applied in weak areas such as underground and marine structures.

PIV Measurements of Wake behind a KRISO 3600TEU Container Ship Model (PIV를 이용한 KRISO 3600TEU 컨테이너선모형선의 반류 측정 및 해석)

  • Sang-Joon Lee;Min-Seok Koh;Choung-Mook Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.39 no.3
    • /
    • pp.48-56
    • /
    • 2002
  • The flow characteristics around KRISO 3600TEU container ship model have been experimentally investigated in a circulating water channel. The instantaneous velocity vectors were measured using 2-frame PIV measurement system. The mean velocity fields and turbulent statistics including turbulent kinetic energy and vorticity were obtained by ensemble-averaging 400 instantaneous velocity fields. The free stream velocity was fixed at 0.6m/s and the corresponding Reynolds number was $9{\times}10^5$. The test sections were divided into two regions, three transverse sections of the wake region(Station -0.5767, -1, -3) and five longitudinal sections of the wake((Z/(B/2)=0, 0.1, 0.2, 0.4, 0.6). In the wake region, large-scale longitudinal vortices of nearly same strength are symmetric with respect to the wake centerline and a relatively weak secondary vortex is formed near the waterline. With going downstream, the strength of longitudinal vortex is decreased and the wake region expands.

Problems of lake water management in Korea (한국의 호수 수질관리의 문제점)

  • 김범철;전만식;김윤희
    • Proceedings of the Korean Society of Environment and Ecology Conference
    • /
    • 2003.10a
    • /
    • pp.105-126
    • /
    • 2003
  • In Korea most of annual rainfall is concentrated in several episodic heavy rains during the season of summer monsoon and typhoon. Because of uneven rainfall distribution many dams have been constructed in order to secure water supply in dry seasons. The Han River system has the most dams among Korean rivers, and the river is a series of dams now. Reservoirs need different strategy of water quality control from river water. Autochthonous organic matter and phosphorus should be the major target to be controlled in lakes. In this Paper some problems are discussed that makes efforts of water quality improvement ineffective in lakes of Korea, even after the substantial investment to wastewater treatment facilities.1) Phosphorus is the key factor controlling eutrophication of lakes and the reduction ofphosphors should be the major target of water treatment. However, water quality management strategy in Korea is still stream-oriented, and focused on BOD removal from sewage. Phosphorus removal efficiency remains as low as 10-30%, because biological treatment is adopted for both secondary treatment and advanced treatment. The standard for TP concentration of the sewage treatment plant effluent is 6 mgP/l in most of regions, and 2 mg/l in enforced region near metropolitan water intake point. TP in the effluents of sewage treatment plants are usually 1-2 mg/1, and most of plants meet the effluent regulation without a further phosphorus removal process. The generous TP standard for effluents discourages further efforts to improve phosphorus removal efficiency of sewage treatment. Considering that TP standard for the effluent is below 0.1 mg/l in some countries, it should be amended to below 0.1 mg/l in Korea, especially in the watershed of large lakes.2) Urban runoff and combined sewer overflow are not treated, even though their total loading into lakes can be comparable to municipal sewage discharges on dry days. Chemical coagulation and rapid settling might be the solution to urban runoff in regard of intermittent operation on only rainy days.3) Aggregated precipitation in Korea that is concentrated on several episodic heavyrains per year causes a large amount of nonpoint source pollution loading into lakes. It makes the treatment of nonpoint source discharge by methods of other countries of even rain pattern, such as retention pond or artificial wetland, impractical in Korea.4) The application rate of fertilizers in Korea is ten times as high as the average ofOECD countries. The total manure discharge from animal farming is thought to be over the capacity of soil treatment in Korea. Even though large portion of manure is composted for organic fertilizer, a lot of nutrients and organic matter emanates from organic compost. The reduction of application rate and discharge rate of phosphorus from agricultural fields should be encouraged by incentives and regulations.5) There is a lot of vegetable fields with high slopes in the upstream region of the HanRiver. Soil erosion is severe due to high slopes, and fertilizer is discharged in the form of adsorbed phosphorus on clay surface. The reduction of soil erosion in the upland area should be the major preventive policy for eutrophication. Uplands of high slope must be recovered to forest, and eroded gullies should be reformed into grass-buffered natural streams which are wider and resistant to bank erosion.

  • PDF

A Study on the Attracting Strategy of FDI in Gwangju and Jeonnam Region (외국인직접투자 유치전략에 관한 연구 -광주.전남지역을 중심으로-)

  • Shim, Jae-Hee;Baek, Hyung-Yeop
    • International Commerce and Information Review
    • /
    • v.13 no.1
    • /
    • pp.145-175
    • /
    • 2011
  • This paper suggests the strategy for attracting FDI in Gwangju and Jeonnam region using the secondary data collected by homepage of Ministry of Knowledge Economy, Gwangju City, and Jeollanam-do. The strategy for attracting FDI in Gwangju and Jeonnam region is as follows: First, the local governments of Gwangju and Jeonnam must progressively attract FDI by adjusting to the Korean government's regional industry policy direction. Second, in order to attract FDI consistently, the local governments of Gwangju and Jeonnam must enhance the ability of local officials to attract FDI. Third, in order to attract FDI effectively, the local governments of Gwangju and Jeonnam must build a complete system to support FDI. Fourth, in order to attract FDI effectively, the local governments of Gwangju and Jeonnam have to apply different investment incentives according to FDI effectiveness. Fifth, the local governments of Gwangju and Jeonnam must consistently support foreign companies in order to induce FDI expansion by foreign companies which have already invested in the Gwangju and Jeonnam regions. Finally, in order to attract FDI consistently, the local governments of Gwangju and Jeonnam must improve the negative images and living environments of the Gwangju and Jeonnam regions.

  • PDF

The characteristics of chloramine formation and decay with pH variation (pH 변화에 따른 클로라민 생성과 분해 특성)

  • 조관형;김평청;우달식;조영태
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.347-353
    • /
    • 2002
  • This study was conducted to investigate the characteristics of chloramination as a secondary disinfection in a drinking water distribution system. At the range from pH 6 to pH 8, monochloramine was predominant with a trace of dichloramine, and the free chlorine was detected after breakpoint. At $25^{\circ}C$, the breakpoints of pH 6, 7 and 8 appeared when the weight ratios of chlorine to ammonia nitrogen were 11:1, 9:1 and 10:1 respectively, and the peak points on the breakpoint curves at pH 6, 7 and 8 were in the Cl$_2$ / NH$_3$-N ratio of 9:1, 6:1 and 5:1 respectively. As pH increased from 6 to 8, maximum point of monochloramine on the breakpoint curve was moved from 7:1 to 5:1 in the weight ratio of chlorine to ammonia nitrogen. The maximum concentration of monochloramine was formed at the pH values of 7~8 and in the Cl$_2$ / NH$_3$-N ratio below 5:1. As the Cl$_2$/NH$_3$-N ratio increased and the pH lowered, chloramines decay proceeded at an increased rate, and residual chloramines lasted longer than the residual free chlorine. The monochloramine and the dichloramine were formed at pH 6, and then the dichloramine continued increasing with contact time.