• Title/Summary/Keyword: Sd

Search Result 5,909, Processing Time 0.035 seconds

Design of DVB-T/H SiP using IC-embedded PCB Process (IC-임베디드 PCB 공정을 사용한 DVB-T/H SiP 설계)

  • Lee, Tae-Heon;Lee, Jang-Hoon;Yoon, Young-Min;Choi, Seog-Moon;Kim, Chang-Gyun;Song, In-Chae;Kim, Boo-Gyoun;Wee, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.9
    • /
    • pp.14-23
    • /
    • 2010
  • This paper reports the fabrication of a DVB-T/H System in Package (SiP) that is able to receive and process the DVB-T/H signal. The DVB-T/H is the European telecommunication standard for Digital Video Broadcasting (DVB). An IC-embedded Printed Circuit Board (PCB) process, interpose a chip between PCB layers, has applied to the DVB-T/H SiP. The chip inserted in DVB-T/H SiP is the System on Chip (SoC) for mobile TV. It is comprised of a RF block for DVB-T/H RF signal and a digital block to convert received signal to digital signal for an application processor. To operate the DVB-T/H IC, a 3MHz DC-DC converter and LDO are on the DVB-T/H SiP. And a 38.4MHz crystal is used as a clock source. The fabricated DVB-T/H SiP form 4 layers which size is $8mm{\times}8mm$. The DVB-T/H IC is located between 2nd and 3rd layer. According to the result of simulation, the RF signal sensitivity is improved since the layout modification of the ground plane and via. And we confirmed the adjustment of LC value on power transmission is necessary to turn down the noise level in a SiP. Although the size of a DVB-T/H SiP is decreased over 70% than reference module, the power consumption and efficiency is on a par with reference module. The average power consumption is 297mW and the efficiency is 87%. But, the RF signal sensitivity is declined by average 3.8dB. This is caused by the decrease of the RF signal sensitivity which is 2.8dB, because of the noise from the DC-DC converter.

Breeding status and nest site characteristics of Black-faced Spoonbills Platalea minor on Chilsando Islands, Korea (칠산도의 저어새 번식 현황과 둥지장소 특성)

  • Kwon, In-Ki;Kang, Jung-Hoon;Lee, Ki-Sup;Lee, Ji-Yeon;Kim, In-Kyu;Yoo, Jeong-Chil
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.5
    • /
    • pp.703-709
    • /
    • 2015
  • A breeding pair of the Black-faced Spoonbill Platalea minor was firstly recorded on Chilsando Islands, Younggwang, Jeollanamdo Province in 1991. Since the mid 2000s, breeding population on the breeding sites has gradually increased. This study was conducted to identify breeding status and nest site characteristics of the species from May to August, 2013 on Chilsando Islands. We recorded number of nests, length and width of the nest base, slope around the nests, nest materials, distances from the nearest nest, presence of nest cover and nesting area. In 2013 breeding season, 25 of 49 nests produced at least one successful fledging. A total of 55 youngs were successfully fledged and number of fledging per nest was 2.20 individuals. Nesting area was $77.8m^2$ and $93.4m^2$ for Sansando and Yuksando Islet, respectively. Soil and soil mixed with tree root were preferred for substrate of nest base over rock and Brassica napus was dominantly selected as nest materials by Black-faced Spoonbills. Nest characteristics of 22 nests in Sasando and Yuksando Islet varied $49.59{\pm}6.53cm$(mean${\pm}$SD) for length of nest base, $41.00{\pm}5.82cm$ for width of nest base, $20.85{\pm}9.96^{\circ}$ for slope above the nest, $34.09{\pm}17.75^{\circ}$ for slope below the nest and $130.82{\pm}84.17cm$ for distances from the nearest nest. Fifteen pairs (68.2%) occupied where nest cover existed. Nest cover were located in front of the nest for 5 pairs, back of the nest for 9 pairs and both front and back of the nest for 1 pair.

A Comparison of Needs for Hospice Care between Families of Children and Adult with Cancer (암 환아 및 암 환자 가족의 호스피스 요구도 비교)

  • Kang, Kyung-Ah;Kim, Shin-Jeong
    • Journal of Hospice and Palliative Care
    • /
    • v.8 no.2
    • /
    • pp.216-223
    • /
    • 2005
  • Purpose: The purpose of this study was to compare the need for hospice care between families of children and adults with cancer. Methods: The data was collected from 190 families of children and adult with cancer using self-rating questionnaires from December, 2004 to February, 2005. Data was analyzed using SPSS/Win program by Mean, SD and t-test. Results: The mean score of the need for hospice care in families of children with cancer was greater significantly than in families of adults with cancer (t=-2.126, P=.035). The scores of two factors among the five factors evaluated for the need for hospice care were different significantly. The mean score of control of major terminal physical symptoms' in families of children with cancer was greater significantly than the mean score of adults with cancer (t=-2.165, P=.032). The mean score of 'spiritual care to prepare for death' in families of adults with cancer was greater significantly than the mean score of children with cancer (t=-2.380, P=.018). Conclusion: For improving the quality of life for both patients and families, the hospice service program needs to consider the life cycle of patients.

  • PDF

Study of Kidney Toxicity of Azadirachta Indica Extract for Oral Administration in Rats (님추출물의 경구투여에 따른 랫드의 신장독성 연구)

  • Yoon, Hyunjoo;Choe, Miseon;Cho, Hyeon-Jo;Han, Beom Seok;Park, Kyung-Hun;Oh, Jin-Ah;Cho, Namjun;Paik, Min-Kyoung
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.2
    • /
    • pp.103-110
    • /
    • 2014
  • BACKGROUND: Azadirachta indica has been widely used as environment-friendly organic materials because of its insecticidal properties. This study was carried out to investigate the acute toxicity and the subacute toxicity of Azadirachta indica extract(AIE) in rats. METHODS AND RESULTS: For the oral acute toxicity test, Sprague-Dawley rats were gavaged with 2.0 g/Kg bw of AIE. The $LD_{50}$ value was greater than 2.0 g/Kg bw for both male and female rats. For the subacute toxicity study, rats were treated with AIE at doses of 0.5, 1.0, 2.0 mg/Kg bw once a day for 4 weeks(n=10 animals per each group). There were no significant changes in body weight, food intake and water consumption observed during the experimental duration. In addition, no difference of relative kidney weight was observed among all treated groups. Serum creatinine level in the AIE 2.0 g/Kg group increased significantly compared with that of control group in male rats, but serum blood urea nitrogen was significantly decreased in a dose-dependent manner (p<0.05). Significant increase of serum cholesterol levels were observed in all AIE groups, compared with the control group, in the female rats (p<0.05). However, histopathological examination of the kidney did not reveal any significant lesions in all groups. CONCLUSION: On the basis of results, it could be concluded that oral administration AIE didn't cause any toxic response in kidney, except the increased serum cholesterol.

Reduction of Postsurgical Adhesion Formation of Reproductive Tract with Sodium Carboxymethylcellulose in Korean Black Goats (Sodium Carboxymethylcellulose가 개복 수술한 한국흑염소의 생식기 유착 방지에 미치는 영향 평가)

  • Shin, H.G.;Choi, Y.S.;Lee, S.J.;Lee, D.S.;Cho, J.K.;Shin, S.T.
    • Journal of Embryo Transfer
    • /
    • v.22 no.1
    • /
    • pp.63-67
    • /
    • 2007
  • This study was performed to evaluate the efficacy of sodium carboxymethylcellulose (SCMC) for the prevention of postoperative uterus and ovary adhesion formation in the Korean black goats. Twenty adult female Korean black goats randomly were divided into five groups with four animals in each group. After the routine laparotomy, catheter for injection was inserted into the abdomen. Before abdominal closure, saline, 1% SCMC, 2% SCMC or 0.4% HA solution (50ml/10kg of body weight/head) were injected in the abdominal cavity in each group. Three weeks after surgery, second laparotomy was performed and the adhesions were scored on a scale of 0 to 10 according to their vascularity and adhesion size in uterus and ovary. This trial was repeated the four times with the interval of three weeks. In the first and second trial, the group treated with 2% SCMC significantly reduced the adhesion formation than other treatment groups (P<0.05). In the third trial, the adhesion formation was significantly reduced in 2% SCMC and 1% SCMC (P<0.05). In the fourth trial, 2% SCMC reduced the adhesion formation. However, there was no significant difference among other groups. This study showed that the 2% SCMC administered at the end of the surgery reduced the adhesion formation in the Korean black goats.

The Understanding and Application of Noise Reduction Software in Static Images (정적 영상에서 Noise Reduction Software의 이해와 적용)

  • Lee, Hyung-Jin;Song, Ho-Jun;Seung, Jong-Min;Choi, Jin-Wook;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.54-60
    • /
    • 2010
  • Purpose: Nuclear medicine manufacturers provide various softwares which shorten imaging time using their own image processing techniques such as UlatraSPECT, ASTONISH, Flash3D, Evolution, and nSPEED. Seoul National University Hospital has introduced softwares from Siemens and Philips, but it was still hard to understand algorithm difference between those two softwares. Thus, the purpose of this study was to figure out the difference of two softwares in planar images and research the possibility of application to images produced with high energy isotopes. Materials and Methods: First, a phantom study was performed to understand the difference of softwares in static studies. Various amounts of count were acquired and the images were analyzed quantitatively after application of PIXON, Siemens and ASTONISH, Philips, respectively. Then, we applied them to some applicable static studies and searched for merits and demerits. And also, they have been applied to images produced with high energy isotopes. Finally, A blind test was conducted by nuclear medicine doctors except phantom images. Results: There was nearly no difference between pre and post processing image with PIXON for FWHM test using capillary source whereas ASTONISH was improved. But, both of standard deviation(SD) and variance were decreased for PIXON while ASTONISH was highly increased. And in background variability comparison test using IEC phantom, PIXON has been decreased over all while ASTONISH has shown to be somewhat increased. Contrast ratio in each spheres has also been increased for both methods. For image scale, window width has been increased for 4~5 times after processing with PIXON while ASTONISH showed nearly no difference. After phantom test analysis, ASTONISH seemed to be applicable for some studies which needs quantitative analysis or high contrast, and PIXON seemed to be applicable for insufficient counts studies or long time studies. Conclusion: Quantitative values used for usual analysis were generally improved after application of the two softwares, however it seems that it's hard to maintain the consistency for all of nuclear medicine studies because result images can not be the same due to the difference of algorithm characteristic rather than the difference of gamma cameras. And also, it's hard to expect high image quality with the time shortening method such as whole body scan. But it will be possible to apply to static studies considering the algorithm characteristic or we can expect a change of image quality through application to high energy isotope images.

  • PDF

The Influence of Iteration and Subset on True X Method in F-18-FPCIT Brain Imaging (F-18-FPCIP 뇌 영상에서 True-X 재구성 기법을 기반으로 했을 때의 Iteration과 Subset의 영향)

  • Choi, Jae-Min;Kim, Kyung-Sik;NamGung, Chang-Kyeong;Nam, Ki-Pyo;Im, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.122-126
    • /
    • 2010
  • Purpose: F-18-FPCIT that shows strong familiarity with DAT located at a neural terminal site offers diagnostic information about DAT density state in the region of the striatum especially Parkinson's disease. In this study, we altered the iteration and subset and measured SUV${\pm}$SD and Contrasts from phantom images which set up to specific iteration and subset. So, we are going to suggest the appropriate range of the iteration and subset. Materials and Methods: This study has been performed with 10 normal volunteers who don't have any history of Parkinson's disease or cerebral disease and Flangeless Esser PET Phantom from Data Spectrum Corporation. $5.3{\pm}0.2$ mCi of F-18-FPCIT was injected to the normal group and PET Phantom was assembled by ACR PET Phantom Instructions and it's actual ratio between hot spheres and background was 2.35 to 1. Brain and Phantom images were acquired after 3 hours from the time of the injection and images were acquired for ten minutes. Basically, SIEMENS Bio graph 40 True-point was used and True-X method was applied for image reconstruction method. The iteration and Subset were set to 2 iterations, 8 subsets, 3 iterations, 16 subsets, 6 iterations, 16 subsets, 8 iterations, 16 subsets and 8 iterations, 21 subsets respectively. To measure SUVs on the brain images, ROIs were drawn on the right Putamen. Also, Coefficient of variance (CV) was calculated to indicate the uniformity at each iteration and subset combinations. On the phantom study, we measured the actual ratio between hot spheres and back ground at each combinations. Same size's ROIs were drawn on the same slide and location. Results: Mean SUVs were 10.60, 12.83, 13.87, 13.98 and 13.5 at each combination. The range of fluctuation by sets were 22.36%, 10.34%, 1.1%, and 4.8% respectively. The range of fluctuation of mean SUV was lowest between 6 iterations 16 subsets and 8 iterations 16 subsets. CV showed 9.07%, 11.46%, 13.56%, 14.91% and 19.47% respectively. This means that the numerical value of the iteration and subset gets higher the image's uniformity gets worse. The range of fluctuation of CV by sets were 2.39, 2.1, 1.35, and 4.56. The range of fluctuation of uniformity was lowest between 6 iterations, 16 subsets and 8 iterations, 16 subsets. In the contrast test, it showed 1.92:1, 2.12:1, 2.10:1, 2.13:1 and 2.11:1 at each iteration and subset combinations. A Setting of 8 iterations and 16 subsets reappeared most close ratio between hot spheres and background. Conclusion: Findings on this study, SUVs and uniformity might be calculated differently caused by variable reconstruction parameters like filter or FWHM. Mean SUV and uniformity showed the lowest range of fluctuation at 6 iterations 16 subsets and 8 iterations 16 subsets. Also, 8 iterations 16 subsets showed the nearest hot sphere to background ratio compared with others. But it can not be concluded that only 6 iterations 16 subsets and 8 iterations 16 subsets can make right images for the clinical diagnosis. There might be more factors that can make better images. For more exact clinical diagnosis through the quantitative analysis of DAT density in the region of striatum we need to secure healthy people's quantitative values.

  • PDF

ELISA of paragonimiasis in cat by crude and purified antigens of Paragonimus westermani (폐흡충(肺吸蟲)의 조(粗)항원과 정제(精製)항원에 의한 폐흡충(肺吸蟲)감염 고양이혈청의 면역효소반응(免疫酵素反應))

  • Lee, Ok-Ran;Chang, Jae-Kyung
    • Parasites, Hosts and Diseases
    • /
    • v.24 no.2
    • /
    • pp.187-193
    • /
    • 1986
  • Enzyme-linked immunosorbent assay(ELISA) using crude and affinity-purified antigens of adult worms of Paragonimus westermani was performed for infected cat sera with different worm burden, from preinfection to 18th week after infection. Crude antigen was used with supernatant of homogenated worms by freezing-thawing method, and the supernate was centrifuged for 1 hour at 10,000 rpm at $4^{\circ}C$. Affinity-purified antigen(antibody-bound antigen) was prepared from fractions(bound and unbound) of crude antigen by affinity chromatography on CNBr-activated sepharose 4B, and IgG as a ligand was prepared from paragonimiasis cat serum(6 months infected) obtained by ammonium sulfate ($40%{\sim}45%$ saturated) precipitation method. By SDS-PAGE, crude antigen showed 22 polypeptide fractions while purified antigen showed 4 fractions: 36, 400, 34, 700, 27, 600 and 11, 500 in molecular weights. All cats were divided into five groups($G_1-G_5$) by different worm burdens. The mean of recovered worms(${\pm}SD$) and the number of cats in each group are as follows: $G_1$, 2 worms(0) and 4 cats; $G_2$, 4.75 (${\pm}0.66$) and eight; $G_3$, 10.75(${\pm}1.92$) and four; $G_4$, 23.20(${\pm}3.43$) and five; $G_5$, 48(${\pm}12.63$) and five cats. The results were summarized as follows: 1. The antibody levels(OD value) increased by worm burden in $G_1$ to $G_4$ generally. However, individual antibody levels were not exactly related with worm burden in all groups, especially there was a wide difference in $G_4$ and $G_5$. These results suggested that the worm burden in $G_4$ (about $20{\sim}30$ worms) is enough to produce antibody maximum in cats of $2{\sim}3kg$ weight. 2. The antibody levels increased significantly(p<0.05) compared to control sera at the 3rd week in $G_1$ and $G_2$, at the 2nd week in $G_3$, and at the 1st week in $G_4$ and $G_5$. Especially in the 4th week, OD value increased more in $G_1$(p<0.01) and in $G_2$ to $G_5$(p<0.001). In the pattern of antibody levels by ELISA in each group, OD in $G_1$ increased to the 18th week continuously, in $G_2$ OD was maintained same after the 16th week, but in $G_3$ it decreased after the 16th week, and it was maintained same in $G_4$ and $G_5$ after the 14th week. 3. The antibody levels by ELISA with the affinity-purified antigen were higher than those with crude antigen in all groups generally. Especially, the difference of OD values between two antigens was larger from the 4th to the 10th week. In $G_1$ and $G_2$ OD with purified antigen was higher than that with crude one to the 18th week. It was also higher in $G_3$ than that with crude antigen to the 16th week and OD of $G_4$ and $G_5$ were higher before the 14th week than that with crude antigen, however became lower at the 16th week. Consequently, the antibody level in ELISA with affinity-purified antigen was more sensitive at the early weeks after infection and in light infection groups than that with crude antigen.

  • PDF

Qualitative and quantitative PCR detection of insect-resistant genetically modified rice Agb0101 developed in korea (해충저항성 유전자변형 벼 Agb0101에 대한 PCR 검정)

  • Shin, Kong-Sik;Lee, Jin-Hyoung;Lim, Myung-Ho;Woo, Hee-Jong;Qin, Yang;Suh, Seok-Cheol;Kweon, Soon-Jong;Cho, Hyun-Suk
    • Journal of Plant Biotechnology
    • /
    • v.40 no.1
    • /
    • pp.18-26
    • /
    • 2013
  • Genetically modified (GM) rice Agb0101, which expresses the insecticidal toxin modified cry1Ac (mcry1Ac1) gene, was developed by the Rural Development Administration in Korea. To monitor the probable release of Agb0101 in the future, it is necessary to develop a reliable detection method. Here, we developed the PCR detection method for monitoring and tracing of GM rice. The primer pair (RBEgh-1/-2) from a starch branching enzyme (RBE4) gene was designed as an endogenous reference, giving rise to an expected PCR amplicon of 101 bp. For the qualitative PCR detection, construct- and event-specific primers were designed on the basis of integration sequence of T-DNA. Event-specific PCRs amplified specifically 5'- or 3'-junction region spanning the native genome DNA and the integrated gene construct, while none of amplified product was shown on crops, rice varieties, and other insect-resistant transgenic rice lines. The event-specific real-time PCR method was performed using TaqMan probe and plasmid pRBECrR containing both rice endogenous gene RBE4 sequence and 5'-junction sequence as the reference molecule. The absolute limit of quantification (LOQ) of real-time PCR was established with around 10 copies for one plasmid molecule pRBECrR. Thereafter, the different amounts of transgenic rice (1, 3, 5, and 10%, respectively) were quantified by using the established real-time PCR method, with a range below 19.55% of the accuracy expressed as bias, 0.06-0.40 of standard deviation (SD) and 3.80-7.01% of relative standard deviations (RSD), respectively. These results indicate that the qualitative and quantitative PCR methods could be used effectively to detect the event Agb0101 in monitoring and traceability.

Difference in the Set-up Margin between 2D Conventional and 3D CT Based Planning in Patients with Early Breast Cancer (조기유방암환자의 이차원치료계획과 삼차원치료계획의 방사선조사범위의 차이)

  • Jo, Sun-Mi;Chun, Mi-Son;Kim, Mi-Hwa;Oh, Young-Taek;Kang, Seung-Hee;Noh, O-Kyu
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.177-183
    • /
    • 2010
  • Purpose: Simulation using computed tomography (CT) is now widely available for radiation treatment planning for breast cancer. It is an important tool to help define the tumor target and normal tissue based on anatomical features of an individual patient. In Korea, most patients have small sized breasts and the purpose of this study was to review the margin of treatment field between conventional two-dimensional (2D) planning and CT based three-dimensional (3D) planning in patients with small breasts. Materials and Methods: Twenty-five consecutive patients with early breast cancer undergoing breast conservation therapy were selected. All patients underwent 3D CT based planning with a conventional breast tangential field design. In 2D planning, the treatment field margins were determined by palpation of the breast parenchyma (In general, the superior: base of the clavicle, medial: midline, lateral: mid - axillary line, and inferior margin: 2 m below the inframammary fold). In 3D planning, the clinical target volume (CTV) ought to comprise all glandular breast tissue, and the PTV was obtained by adding a 3D margin of 1 cm around the CTV except in the skin direction. The difference in the treatment field margin and equivalent field size between 2D and 3D planning were evaluated. The association between radiation field margins and factors such as body mass index, menopause status, and bra size was determined. Lung volume and heart volume were examined on the basis of the prescribed breast radiation dose and 3D dose distribution. Results: The margins of the treatment field were smaller in the 3D planning except for two patients. The superior margin was especially variable (average, 2.5 cm; range, -2.5 to 4.5 cm; SD, 1.85). The margin of these targets did not vary equally across BMI class, menopause status, or bra size. The average irradiated lung volume was significantly lower for 3D planning. The average irradiated heart volume did not decrease significantly. Conclusion: The use of 3D CT based planning reduced the radiation field in early breast cancer patients with small breasts in relation to conventional planning. Though a coherent definition of the breast is needed, CT-based planning generated the better plan in terms of reducing the irradiation volume of normal tissue. Moreover it was possible that 3D CT based planning showed better CTV coverage including postoperative change.