• Title/Summary/Keyword: Screen Printed Carbon Electrode

Search Result 41, Processing Time 0.027 seconds

Electrochemical Immunoassay for Detecting Hippuric Acid Based on the Interaction of Osmium-Antigen Conjugate Films with Antibody on Screen Printed Carbon Electrodes

  • Choi, Young-Bong;Jeon, Won-Yong;Kim, Hyug-Han
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.1485-1490
    • /
    • 2012
  • An electrochemical immunoassay based on osmium-hippuric acid (HA) conjugate films onto the electrode is presented for the detection of urinary HA. This is the first report on the use of the oxidative electropolymerization of 5-amino-1,10-phenanthroline (5-$NH_2$-phen) for immobilizing an antigen, osmium-conjugated HA. As a redox mediator, [Os(5-amino-1,10-phenanthroline)$_2$(4-aminomethylpyridine-HA)Cl]$^{+/2+}$ (Os-phen-HA) was successfully synthesized and electropolymerized onto the screen-printed carbon electrodes (SPCEs). The interaction between osmium-HA conjugate films and antibody-HA ($anti$-HA) was performed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The electrical signals were linearly proportional to urinary HA in the range of 0.1-5.0 mg/mL, which is sufficient for use as an immunosensor using a cutoff concentration of 2.0 mg/mL in urine samples. The proposed electrochemical immunoassay method can be extended to various applications for detecting a wide range of different small antigens in the health care area.

Development of a cholesterol biosensor modified with carbon nanotube (탄소나노튜브를 이용하여 개조한 콜레스테롤 바이오 센서 개발)

  • Kim, Haidong
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.425-429
    • /
    • 2015
  • A cholesterol biosensor was developed using a modified carbon electrode with carbon nanotubes. The disposable cholesterol biosensor was modified with carbon nanotubes to enhance electron transfer during the enzymatic reaction of cholesterol. Cholesterol oxidase and peroxidase, with potassium ferrocyanide as a mediator, were immobilized on a screen-printed carbon nanotube electrode. The electrochemical cholesterol biosensor developed using carbon nanotubes showed a rapid and reliable signal for measuring total cholesterol. The cholesterol sensor showed a linear response in 5 seconds with a small volume (0.5 μL) in the range of 100~400 mg/dL, with a coefficient of variation of 4.0%.

Synthesis of Osmium Redox Complex and Its Application for Biosensor Using an Electrochemical Method (오스뮴 착물 합성과 전기화학적인 방법을 이용한 바이오센서에 관한 연구)

  • Choi, Young-Bong;Kim, Hyug-Han
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.2
    • /
    • pp.150-154
    • /
    • 2007
  • Redox complexes to transport electrodes from biomaterial to electrodes are very important part in commercial biosensor industry. A novel osmium redox complex was synthesized by the coordinating pyridine group with osmium metal. A novel osmium complex is described as $[Os(dme-bpy)_2(ap-im)Cl]^{+/2+}$. We have been studied the electrochemical characteristics of this osmium complex with electrochemical techniques such as cyclic voltammetry and chronoamperommetry. In order to immobilize osmium redox complexes on the electrode, we deposited gold nano-particles on screen printed carbon electrode(SPE). The electrical signal converts the osmium redox films into an electrocatalyst for glucose oxidation. The catalytic currents were monitored that the catalytic currents were linearly increased from 1 mM to 5 mM concentrations of glucose.

Study on Carbon Nano Fiber Emitter for Field Emission Lamp (전계방출광원용 카본나노파이버 에미터 연구)

  • Kim, Kwang-Bok;Lee, Sun-Hee;Yu, Seung-Ho;Kim, Dae-Jun;Kim, Yong-Won
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.21-24
    • /
    • 2008
  • Properties of carbon nano fiber (CNF) as field emitters were described. Carbon nano fiber (CNF) of herringbone was prepared by thermal chemical vapor deposition(CVD). Field emitters mixed with organic binders, conductive materials and were prepared by screen-printing process. In order to increase field emissions, the surface treatment of rubbing & peel-off was applied to the printed CNF emitters on cathode electrode. The measurements of field emission properties were carried out by using a diode structure inline vacuum chamber. CNF of herringbone type showed good emission properties that a turn on field was as low as 2.1 $V/{\mu}m$ and current density was as large as 0.15 $mA/cm^2$ of 4.2 $V/{\mu}m$ with electric field. Through the results. we propose that CNFs are suitable for application of electron emitters in Field Emission Devices.

  • PDF

Tri-enzyme modified electrochemical biosensor for paracetamol detection (파라세타몰 검출을 위한 전기화학적 다중효소 바이오센서)

  • Park, Deog-Su;Shim, Yoon-Bo;Chang, Seung-Cheol
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.29-34
    • /
    • 2008
  • A new disposable amperometric tri-enzyme biosensor for the detection of paracetamol has been developed. The paracetamol sensors developed uses horseradish peroxidase modified screen-printed carbon electrodes (HRP-SPCEs) coupled with immobilized enzymes, tyrosinase and aryl acylamidase, prepared using a poly (vinyl alcohol) bearing styrylpyridinium groups (PVA-SbQ) matrix. Optimization of the experimental parameters has been performed and the paracetamol biosensor showed detection limit for paracetamol is as low as $100{\mu}M$ and the sensitivity of the sensor is $1.46nA{\mu}M^{-1}cm^{-2}$.

Membrane Strip 크로마토그래피 방법에 기초한 전기화학발광 (Electro-Chemiluminescence) 면역센서의 개발

  • Yun, Chae-Ha;Baek, Se-Hwan
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.206-207
    • /
    • 2000
  • A disposable, electro-chemiluminescent immunosensor utilizing a screen-printed carbon electrode and liposome coupled to antibody as tracer has been constructed. In proportion to the analyte (Legionella species as a model) concentration, the analyte-immunoliposome complexes were transferred by the capillary action through a membrane strip to the electrode, the liposomes were lysed in the presence of detergent, and ruthenium was released for signal generation. Such performance of the immunosensor was appropriate for a point-of-care testing.

  • PDF

Spinel Nanoparticles ZnCo2O4 as High Performance Electrocatalyst for Electrochemical Sensing Antibiotic Chloramphenicol

  • Van-Cuong Nguyen;HyunChul Kim
    • Journal of Electrochemical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.152-160
    • /
    • 2024
  • In this study, ZnCo2O4 nanoparticles were synthesized via the coprecipitation method using different annealing temperatures from 200℃ to 800℃. By varying the treatment temperature, the morphology changed from amorphous to tetragonal, and finally to polygonal particles. As temperature increased, the sizes of the nanoparticles also changed from 5 nm at 200℃ to approximately 500 nm at 800℃. The fabricated material was used to modify the working electrode of a screen-printed carbon electrode (SPE), which was subsequently used to survey the detection performance of the antibiotic, chloramphenicol (CAP). The electrochemical results revealed that the material exhibits a good response to CAP. Further, the sample that annealed at 600℃ displayed the best performance, with a linear range of 1-300 μM, and a limit of detection (LOD) of 0.15 μM. The sensor modified with ZnCo2O4 also exhibited the potential for utilitarian application when the recovery in a real sample was above 97%.

Disposable Glucose Sensor Based on Platinised Carbon Paste Electrode (백금 도금된 탄소반죽 전극을 이용한 일회용 글루코오스 센서)

  • Lee Dong Joo;Yoo Jae Hyun;Cui Gang;Choi Moon Hee;Kim Moon Hwan;Ryu Joon Oh;Han Sang-Hyun;Cha Geun Sig;Nam Hakhyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.4
    • /
    • pp.227-231
    • /
    • 1999
  • Disposable, amperometric glucose sensor was constructed using platinised carbon paste electrode. The sensor response was studied by amperometry and cyclic voltammetry applying sample solutions on the strip-type electrode. Platinization of screen-printed carbon paste electrode effectively improved the electrochemical reversibility of a mediator and the analytical characteristics of the sensor. The heterogeneous rate constant for $[Fe(CN)_6]^{4-/3-}$ was $1.45\times10^{-2}cm{\cdot}s^{-1}$. An applied potential of 0.3V vs. Ag/AgCl resulted in the best selectivity for glucose. The apparent Michaelis-Menten constant for glucose on the strip sensor, $K_m^{app}$, was 24.5 mM. To evaluate the analytical performance of the glucose sensor strip, a correlation study was performed with the NOVA S.P, Ultra M analyzer for 30 serum samples containing $80\~297mg/dL$ of glucose: the correlation coefficient value was 0.983. It can be seen that the strip sensor has satisfactory precision and accuracy.

An Oxalic Acid Sensor Based on Platinum/Carbon Black-Nickel-Reduced Graphene Oxide Nanocomposites Modified Screen-Printed Carbon Electrode

  • Income, Kamolwich;Ratnarathorn, Nalin;Themsirimongkon, Suwaphid;Dungchai, Wijitar
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.416-423
    • /
    • 2019
  • A novel non-enzymatic oxalic acid (OA) sensor based on the platinum/carbon black-nickel-reduced graphene oxide (Pt/CBNi-rGO) nanocomposite is reported. The nanocomposites were prepared by the ethylene glycol reduction method. Their morphology and chemical composition were characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX) and transmission electron microscopy (TEM). The results clearly demonstrated the formation of the Pt/CB-Ni-rGO nanocomposite. The electrocatalytic activity of the Pt/CB-Ni-rGO electrode was investigated by cyclic voltammetry. It was determined that the appropriate amount of Pt enhanced the catalytic activity of Pt for oxalic acid electro-oxidation. Moreover, the modified electrode was determined to be highly selective for oxalic acid without interference from compounds commonly found in urine including uric acid and ascorbic acid. The chronoamperometric signal gave a wide linearity range of 20 μM-60 mM and the detection limit (3σ) was found to be 2.35 μM. The proposed method showed high selectivity, stability, and good reproducibility and could be used with micro-volumes of sample for the detection of oxalic acid. Finally, the oxalic acid content in artificial and control urine samples were successfully determined by our proposed electrode.

Fabrication of Potentiometric Sodium-ion Sensor Based on Carbon and Silver Inks and its Electrochemical Characteristics (탄소 및 은 잉크 기반의 전위차 나트륨 이온 센서 제조 및 이의 전기화학적 특성)

  • Kim, Seo Jin;Son, Seon Gyu;Yoon, Jo Hee;Choi, Bong Gill
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.456-460
    • /
    • 2021
  • A potentiometric sodium-ion (Na+) sensor was prepared using a screen-printing process with carbon and silver inks. The two-electrode configuration of the sensor resulted in potential differences in Na+ solutions according to Nernstian equation. The obtained Na+-sensor exhibited an ideal Nernstian sensitivity, fast response time, and low limit of detection. The Nernstian response was stable when the sensor was tested for repeatability and long-term durability. The Na+-selective membrane coated onto the carbon electrode selectively passed sodium ions against interfering ions, indicating an excellent selectivity. The portable Na+-sensor was finally fabricated using a printed circuit system, demonstrating the successful measurements of Na+ concentrations in various real samples.