• Title/Summary/Keyword: Salt removal efficiency

Search Result 76, Processing Time 0.025 seconds

A Study on the Pb-contaminated Soil Remediation by Organic Acid Washing (유기산을 이용한 납 오염토양의 복원에 관한 연구)

  • 정의덕
    • Journal of Environmental Science International
    • /
    • v.9 no.5
    • /
    • pp.437-441
    • /
    • 2000
  • A study on the removal of Pb ion from Pb-contaminated soil was carried out using ex-site extraction process. Tartaric acid (TA) and iminodiacetic acid sodium salt(IDA) as a washing agent were evaluated as a function of concentration reaction time mixing ratio of washing agent and recycling of washing agent. TA showed a better extraction performance than IDA. The optimum washing condition of TA and IDA were in the ratio of 1:15 and 1:20 between soil and acid solution during 1 hr reaction. The total concentrations of Pb ion by TA and IDA at three repeated extraction were 368.8 ppm and 267.5 ppm respectively. The recovery of Pb ion from washing solution was achieved by adding calcium hydroxide and sodium sulfide form the precipitation of lead hydroxide and lead sulfide and optimum amounts of sodium sulfide and calcium hydroxide were 7 g/$\ell$ for the TA washing solution and 4 g/$\ell$, 5g/$\ell$ for the IDA washing solution respectively. The efficiency of recycle for TA and IDA washing solution were 78.8% , 95.1%, and 89.2%, 96.6% at third extractions under $Na_2S$ and $Ca(OH)_2$, respectively.

  • PDF

Electrochemical Properties of Porous Carbon Electrode as a Function of Internal Electrolyte Concentration (전극 내부의 전해질 농도 변화에 따른 다공성 탄소전극의 전기화학적 특성)

  • Park, Byeong-Hee;Choi, Jae-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.20 no.6
    • /
    • pp.700-704
    • /
    • 2009
  • The electrochemical properties of porous carbon electrodes as a function of their internal electrolyte concentration were investigated. Cyclic voltammetry, chronoamperometry, and impedance spectroscopic analysis were conducted for carbon electrodes equilibrated with 0.01, 0.05, 0.1, and 0.5 M KCl solution and covered with a cation-exchange membrane. The specific capacitance of the electrodes increased as the internal electrolyte concentration increased, due to a decrease in charging resistance. Experimental results indicated that the salt removal efficiency of the membrane capacitive deionization process could be enhanced by increasing the internal electrolyte concentration, even for an influent with a low salt concentration.

Chemical Treatment of Low-level Radioactive Liquid Wastes(II) (The Determination of Cation Exchange Capacity on various Clay Minerals)

  • Lee, Sang-Hoon;Sung, Nak-Jun
    • Nuclear Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.75-81
    • /
    • 1977
  • This experiment has been carried out to determine the pH dependent cation exchange capacity concerning the sorption phenomenon of long-lived radionuclides contained in low-level liquid radioactive waste on various clay minerals. The pH dependent cation exchange capacity determined by Sawhney's method are used to the analysis of sorption phenomenon. About 70 percent of the total cation exchange capacity is contributed by the pH dependent CEC due to the negative charge originated naturally in clays in case of clinoptilolite, vermiculite and sodalite. It is sugested in this test that the high neutral salt CEC, that is, highly charged clays would show good fixation yield. The removal of radionuclides at the pH range more than pH 9 is considered the hydroxide precipitation of metal ion rather than the cation exchange. The Na-clay prepared by the method of successive isomorphic substitution with electrolyte showed a considerable improvement in removal efficiency for the decontamination.

  • PDF

Preparation and Characterisation of Titanium Dioxide Produced from Ti-salt Flocculated Sludge in Water Treatment (수처리 티탄염 응집 슬러지에서 생산한 산화티탄의 제조와 특성 조사)

  • Shon, Hokyong;Okour, Yousef;Saliby, Ibrahim El;Park, Jun;Cho, Dong-Lyun;Kim, Jong Beom;Park, Hee Ju;Kim, Jong-Ho
    • Applied Chemistry for Engineering
    • /
    • v.20 no.3
    • /
    • pp.241-250
    • /
    • 2009
  • During the past few years, titanium salts were investigated as alternative coagulants for the removal of organic matter of different molecular sizes in contaminated water. The flocculation efficiency of Ti-salt was comparable to those of $FeCl_3$ and $Al_2(SO_4)_3$ salts, commonly used coagulants. Incinerated sludge-$TiO_2$ showed higher surface area and photocatalytic activity than commercially available $TiO_2$. Metal-doped forms were produced by adding coagulant aids such as iron (Fe-), aluminium (Al-) and (Ca-) calcium salts during Ti-salt flocculation to increase pH. Ca- and Al- doped $TiO_2$ showed very high photocatalytic activity compared to Fe-doped $TiO_2$. When tested in a pilot scale plant for treatment of dye wastewater to check practical feasibility of the novel process, the removal ratio of the chemical oxygen demand was comparable to those of commonly used coagulants but the settling of sludge was faster. The $TiO_2$ generated after sludge incineration showed a high photocatalytic activity for degradation of volatile organic compounds and increased the rate of hydrogen production by water photosplitting. $TiCl_4$ coagulant and $TiO_2$ produced from different water sources with different concentrations had low acute toxicity compared to heavy metals and commercial $TiO_2$ when examined based on D. Magna mortality. This paper presents the production, characterisation and the photoactivity of $TiO_2$ produced from Ti-salt flocculated sludge. Different case studies are discussed to highlighted recent advances in this field.

Microfiltration/ultrafiltration polyamide-6 membranes for copper removal from aqueous solutions

  • El-Gendi, Ayman;Ali, Sahar;Abdalla, Heba;Saied, Marwa
    • Membrane and Water Treatment
    • /
    • v.7 no.1
    • /
    • pp.55-70
    • /
    • 2016
  • Microfiltration/ultrafiltration (MF/UF) Adsorptive polyamide-6 (PA-6) membranes were prepared using wet phase inversion process. The prepared PA-6 membranes are characterized by scanning electron microscopy (SEM), porosity and swelling degree. In this study, the membranes performance has examined by adsorptive removal of copper ions from aqueous solutions in a batch adsorption mode. The $PA-6/H_2O$ membranes display sponge like and highly porous structures, with porosities of 41-73%. Under the conditions examined, the adsorption experiments have showed that the $PA-6/H_2O$ membranes had a good adsorption capacity (up to 120-280 mg/g at the initial copper ion concentration ($C_0$) = 680 mg/L, pH7), fast adsorption rates and short adsorption equilibrium times (less than 1.5-2 hrs) for copper ions. The fast adsorption in this study may be attributed to the high porosities and large pore sizes of the $PA-6/H_2O$ membranes, which have facilitated the transport of copper ions to the adsorption. The results obtained from the study illustrated that the copper ions which have adsorbed on the polyamide membranes can be effectively desorbed in an Ethylene dinitrilotetra acetic acid Di sodium salt ($Na_2$ EDTA) solution from initial concentration (up to 92% desorption efficiency) and the PA-6 membranes can be reused almost without loss of the adsorption capacity for copper ions. The results obtained from the study suggested that the $PA-6/H_2O$ membranes can be effectively applied for the adsorptive removal of copper ions from aqueous solutions.

Effect of Flux on Recovery of Aluminum During Molten Metal Treatment of Aluminum Can Scrap (알루미늄 캔 스크랩의 용탕처리 시 알루미늄 합금 회수에 미치는 플럭스의 영향)

  • Han, Chulwoong;Ahn, Byung-Doo;Kim, Dae-Guen;Lee, Man Seung;Kim, Yong Hwan
    • Resources Recycling
    • /
    • v.29 no.1
    • /
    • pp.70-80
    • /
    • 2020
  • This study investigates the effect of flux type and mixing ratio on efficiency in aluminum can scrap recycling using induction furnace. The removal of surface coating layer of aluminum can scrap was possible through heat treatment at about 500 ℃ for about 30 min. The temperature for the melting process was set to be slightly above the melting temperature of the aluminium can scrap. The molten metal treatment was performed with different types of flux and mixing ratio. As a result, The optimum efficiency of Al recovery ratio was revealed when the process was performed with at least 3 wt.% of the flux (Salt and MgCl2 mixture of ratio 70:30) at 750 ℃. The mechanical property of the recovered Al alloy showed that the tensile strength is about 249 MPa and elongation is about 14 %. This result was found to be similar to the mechanical property of the virgin Al 5083 alloy.

Application of Capacitive Deionization Packed Ion Exchange Resins in Two Flow Channels (두 가지 유로 형태에 따라 이온교환수지를 채운 축전식 탈염기술)

  • Lee, Dong-Ju;Park, Jin-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.18 no.1
    • /
    • pp.24-30
    • /
    • 2015
  • To desalinate the aqueous solutions with high salt concentration using the capacitive deionization technology, two resin/membrane capacitive deionization(RMCDI) cells were fabricated by filling mixed ion exchange resins in two different flow channels (spacer and spiral type). The salt removal efficiency of the spacer- and spiral-RMCDI was 77.21 and 99.94%, respectively. Many ions were significantly removed in a spiral RMCDI cell because the feed solution could be more evenly contacted with the ion exchange resins filled on the spiral type flow channel. As the result of the changes of pH and accumulative charges, it was observed that Faradaic reaction was diminished for a spiral RMCDI cell filled by the mixture of cation and anion exchange resins. Therefore, the desalination of the aqueous solutions with high salt concentration by the capacitive deionization technology was proven. In addition, further studies on the optimization of the mixing ratio with ion exchange resins and the introduction of the regeneration process generally occurred in the continuous electrodeionization (CEDI) technology are required to improve the RMCDI technology.

Enhanced photo-Fenton degradation of tetracycline using TiO2-coated α-Fe2O3 core-shell heterojunction

  • Zheng, Xiaogang;Fu, Wendi;Kang, Fuyan;Peng, Hao;Wen, Jing
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.68
    • /
    • pp.14-23
    • /
    • 2018
  • $TiO_2-coated$ cubic ${\alpha}-Fe_2O_3$ with mostly exposed (012) and (101) facets (${\alpha}-Fe_2O_3@TiO_2$) was fabricated using a hydrothermal route for the photo-Fenton degradation of tetracycline under visible light irradiation. $TiO_2$ coating could greatly affect the photocatalytic activity of ${\alpha}-Fe_2O_3@TiO_2$. Compared with cubic ${\alpha}-Fe_2O_3$ alone for photodegradation of tetracycline, ${\alpha}-Fe_2O_3@TiO_2$ with $TiO_2$ shell of around 15 nm exhibited higher removal efficiency of tetracycline in photo-Fenton system, and its durability was slightly affected after five cycle times under same conditions. It is ascribed to the well-matched interface between cubic ${\alpha}-Fe_2O_3$ core and $TiO_2$ shell, leading to the broadened light-absorption and the efficient separation of photo-generated electon-hole pairs. The $^{\bullet}OH$ radicals were main responsible for the advanced photocatalytic performance of ${\alpha}-Fe_2O_3@TiO_2$ in visible-light driven degradation of tetracycline.

Multi- effect air gap membrane distillation process for pesticide wastewater treatment

  • Pangarkar, Bhausaheb L.;Deshmukh, Samir K.;Thorat, Prashant V.
    • Membrane and Water Treatment
    • /
    • v.8 no.6
    • /
    • pp.529-541
    • /
    • 2017
  • A multi-effect air gap membrane distillation (ME-AGMD) module for pesticide wastewater treatment is studied with internal heat recovery, sensible heat of brine recovery, number of stages and the use of fresh feed as cooling water in a single module is implemented in this study. A flat sheet polytetrafluroethylene (PTFE) membrane was used in the 4-stage ME-AGMD module. The maximum value of permeate flux could reach $38.62L/m^2h$ at feed -coolant water temperature difference about $52^{\circ}C$. The performance parameter of the module like, specific energy consumption and gain output ratio (GOR) was investigated for the module with and without heat recovery. Also, the module performance was characterized with respect to the separation efficiency of several important water quality parameters. The removal efficiency of the module was found to be >98.8% irrespective water quality parameters. During the experiment the membrane fouling was caused due to the deposition of the salt/crystal on the membrane surface. The membrane fouling was controlled by membrane module washing cycle 9 h and also by acidification of the feed water (pH=4) using 0.1M HCl solution.

Effect of TS Concentration on Anaerobic Digestion using Supernatant of Food Waste (음식물류 폐기물 혐기성 소화에 있어서 TS농도 영향)

  • Jang, Eun-sung;Ruy, Seung-hun;Phae, Chae-gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.2
    • /
    • pp.118-127
    • /
    • 2007
  • This study investigated the effect of varying TS concentration levels using supernatant of food waste. The experiment was performed at varying TS concentration levels ranging from 5% to 10% by a $35^{\circ}C$-mesophilic digestion reactor, dual digestion system with acid and methane fermenters combined. As a result, removal efficiency and stabilization were observed at TS concentration of 7~8%, But the removal efficiency notably decreased at 8% or higher TS level. At a stabilized phase of the reactor, more than $0.3m^3/kg{\cdot}vs$ gas was produced, with phenomena such as salt accumulation and increase of pH level being unnoticed. These results indicate that the increase of anaerobic digestion of food waste supernatant TS content has an effect on reaction and that it is necessary to control and operate concentration within 8%, given that the effect is stronger at 8% or higher.

  • PDF