• Title/Summary/Keyword: Salt contamination

Search Result 124, Processing Time 0.026 seconds

A Detection of Salt Contamination on the Transmission Line Insulator Using Conductivity Sensor (전도도 센서를 이용한 송전선용 애자의 염분량 검출)

  • Kang, Y.W.;Shim, E.B.;Kweon, D.J.;Kwak, J.S.;Jung, C.S.;Lee, O.B.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.189-193
    • /
    • 2002
  • Outage caused by contaminated insulator on high voltage transmission line and in substation is major concern for utility world-wide. To prevent these outages, it is necessary to develop an automatic salt contamination detecting device which provide the information about contamination level on utility for engineer to meet the emergency in advance. For that purpose, we have been developing an automatic salt contamination detecting device to monitor a salt amount on operating power utility area. In the salt contamination detecting device development, the most important thing is the sensor which can detect a salt amount and the understanding of sensor' s detecting principle. This paper describes the operating principle of the sensor and the experimental results about the detecting of salt amount. The results of this experiment wi1l be useful for detecting the contamination level.

  • PDF

A Study on the Laser Aided Measurement of Salt Contamination of Porcelain Insulators (레이저를 이용한 활선 염해 측정)

  • Cho, C.H.;Lee, H.S.;Choi, Y.W.;Kweon, D.J.;Choi, I.H.;Kim, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1807-1809
    • /
    • 1997
  • The salt contamination on the surface of the porcelain insulators used electric power systems causes flash-over accidents. Therefore the quantity of salt contamination should be monitored not to exceed a limit. In this study, we tried laser aided measurement of salt contamination. The Nd:YAG laser beam was focused on the surface of the porcelain insulators which were artificially contaminated, and we detected the D-Line (${\cong}589nm$) of spontaneous emission from the excited sodium atoms with a PMT and an oscilloscope. And we deduced the relation between the detected signals and degree of salt contamination.

  • PDF

The Effect of the Wind Direction and Velocity on the Salt Contamination of the Distribution Facilities (풍향 및 풍속이 배전설비의 염분오손에 미치는 영향)

  • Kim, Chan-Young;Kim, Dong-Myung;Kwon, Tae-Ho;Chun, Sung-Nam
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.499-500
    • /
    • 2006
  • The salt contamination on the distribution facilities was investigated with the wind direction and velocity. Most previous researches were concentrated on the measurement of The Equivalent Salt Deposit Density(ESDD) without environmental consideration. The wind direction and velocity of the many environmental conditions are the most important factors to analyze salt contamination. Pohang area which is located on the south and east of the Korean Peninsula was chosen to do this research. This research will present the result of ESDD depending on the wind direction and velocity.

  • PDF

The Distribution of Salt Contamination with the Influence of Geographical Condition (지리적 영향에 따른 염해 오손물질의 분포에 관한 연구)

  • 최남호;국연호;조성인;박강식;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.695-698
    • /
    • 2000
  • This paper present the result of the investigation, the distribution of salt contamination with the influence of geographical condition. To get the ESDD data, a conventional brush washing method was adapted, and IC(ion chromatography) was used to measure the quantity of anions, such as Cl$\^$-/ and SO$_4$$\^$2-/. And we make an analysis on the distribution of salt contamination with the increase of distance from shore. With 10 month ESDD data, we seek the 95% ESDD value with interpolation method. With these analyses, we had obtained the formulation concerned with the distance from sea. And could know the composition of contamination.

  • PDF

Analysis of Salt Contamination on the Location and the Distance from the coastline (지역 및 해안거리에 따른 염분오손 분석에 관한 연구)

  • Kim, Chan-Young;Kim, Dong-Myung;Kwon, Tae-Ho;Chun, Sung-Nam;Ko, Dong-Hyeon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.511-512
    • /
    • 2006
  • The salt contamination on the distribution facilities is one of the major concern areas because more than 90% of salt contaminated failure occurs in distribution facilities. The periodic measurement of the Equivalent Salt Deposit Density(ESDD) is essential to manage and operate the power line. The ESDD has taken from the 112 position which is located on the coastline of the Korean Peninsula. The ESDD will be presented with the location and the distance from the coastline.

  • PDF

A Study on the Automatic Measurement of Salt Contamination (염분 오손 자동측정에 관한 연구)

  • Kwak, Hee-Ro;Kim, Han-Sang;Kweon, Dong-Jin;Lee, Dong-Zoon;Kim, Kyoung-Wha;Cho, Kug-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1362-1364
    • /
    • 1995
  • In this paper, the automatic device for measuring the salt contamination on insulators was developed. The device consists of electronic insulators, measuring system, monitoring system, and printer. It was shown that the level of salt contamination measured by the developed device is similar to that measured by the brush cleaning method. Therefore, the developed automatic measuring device can be used in field, in order to predict the cleaning time of insulators and prevent the failure due to the salt contamination.

  • PDF

The Development Plan of Salt Contamination Map Using GIS (지리정보 시스템을 이용한 전국 염해 오손도 구축 방안)

  • Kang, Yeon-Woog;Kwak, Joo-Sik;Shim, Eung-Bo;Yoo, Chol-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.377-379
    • /
    • 2001
  • Contamination flashover is responsible for insulator electrical failures. Particularly, in Korea, with its perennially dry spring, the first spring rain often cause serious line outages by forming a conductive liquid film on the insulator surface. Rainwater and fog are not normally conductive but unfortunately atmospheric dust deposited on the insulator surface contains soluble salts which may lead to bad condition of insulation by combining watery and salts. Transmission design engineers have used a contamination map drawn on the traditional paper map. But it is not convenient because it does not include the information of Geographic Information accurately. This paper explains the newly developed salt contamination map program using Geographic Information System, which provide accurate geographic information. The program is designed to use four parts of datum, salt contamination levels, 345kV & 154 kV transmission lines, power plants & substations and background map. The digital background map is composed of raster files, the others are done by vector map.

  • PDF

Insulating Characteristics of the Distribution Facilities due to Grade of Salt Contamination (오손등급에 따른 배전기자재의 절연특성 연구)

  • Kwon, Tae-Ho;Kim, Dong-Myung;Kim, Ju-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1490-1491
    • /
    • 2007
  • The salt contamination on the distribution facilities, such as suspension insulator, line post insulator, lightning arrester, COS, is one of the major coastal areas because more than 90% of salt contaminated failure occurs in distribution facilities. Did to stain distribution facilities artificially according to Equivalent Salt Deposit Density(ESDD) grade. The electrical test were performed on the non-polluted and polluted facilities(ESDD B, C, D grade).

  • PDF

Analysis of the Correlation on the Weather Conditions and the Contamination Degree Using Mu lisle Regression Method (다중회귀를 이용한 기후와 오손도 간의 상관관계 분석)

  • 심규일;최남호;김종석;한상옥
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.199-202
    • /
    • 2001
  • This paper presents the correlation on the contamination degree and weather conditions using the multiple regression of the statistic method. The cotamination is a significant factor in the insulation system. The major factor is natural contamination, and the most is the salt. The salt contamination is occured by the weather conditions. The weather contaminations are wind, precipitation, temperature, relative humidity, etc. The effects of those are different, and the correlation is showed numerically by using the multiple regression method of the statistic method. With this, the estimation of the equivalent salt deposit density(ESDD) becomes possible by the changes of the weather conditions.

  • PDF

The Distribution of Salt Contamination with the Influence of Geographical Condition (지리적 영향에 따른 염해 오손물질의 분포에 관한 연구)

  • Jang, T.I.;Yang, B.M.;Kang, Y.W.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1782-1784
    • /
    • 2000
  • This paper present the result of the investigation, the distribution of salt contamination with the influence of. geographical condition. To get the ESDD data, a conventional brush washing method was adapted, and IC(ion chromatography) was used to measure the quantity of anions, such as $Cl^-$ and ${SO_{4}}^{2-}$. And we make an analysis on the distribution of salt contamination with the increase of distance from shore. With 10 month ESDD data, we seek the 95% ESDD value with interpolation method. With these analyses, we had obtained the formulation concerned with the distance from sea. And could know the composition of contamination.

  • PDF