• Title/Summary/Keyword: Salt Contamination

Search Result 124, Processing Time 0.023 seconds

Clostridium botulinum and Its Control in Low-Acid Canned Foods

  • Reddy, N. Rukma;Skinner, Guy E.;Oh, Sang-Suk
    • Food Science and Biotechnology
    • /
    • v.15 no.4
    • /
    • pp.499-505
    • /
    • 2006
  • Clostridium botulinum spores are widely distributed in nature. Type A and proteolytic type B bacteria produce heat-resistant spores that are primarily involved in most of the food-borne botulism outbreaks associated with low-acid canned foods. Food-borne botulism results from the consumption of food in which C. botulinum has grown and produced neurotoxin. Growth and toxin production of type A and proteolytic type B in canned foods can be prevented by the use of thermal sterilization alone or in combination with salt and nitrite. The hazardousness of C. botulinum in low-acid canned foods can also be reduced by preventing post-process contamination and introducing hazard analysis and critical control point (HACCP) practices during production. Effectiveness of non-thermal technologies such as high pressure processing with elevated process temperatures on inactivation of spores of C. botulinum will be discussed.

Efflorescence Test Evaluation of Concrete Brick and Hollow Concrete Block Products (콘크리트 벽돌 및 속 빈 콘크리트 블록 제품의 백화시험 평가)

  • Lee, Sang-Hyun;Ki, Jun-Do;Cho, Hong-Bum;Kim, Young-Sun;Jeon, Hyun-Soo;Moon, Hyung-Jae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.207-208
    • /
    • 2023
  • Concrete bricks and hollow concrete block products manufactured using ordinary portland cement react with salt and carbon dioxide absorbed from the soil and atmosphere in the use environment, causing contamination such as efflorescence. This is due to the reaction between calcium hydroxide, a cement hydration product, and carbon dioxide, producing and eluting calcium carbonate. This study was a preliminary study to compare and evaluate the reduction of efflorescence in concrete bricks and hollow concrete block products manufactured using carbon dioxide reaction hardening cement. The purpose was to evaluate the efflorescence occurrence in products using ordinary Portland cement.

  • PDF

Electrolytic Decontamination of the Dismantled Metallic Wastes Contaminated with Uanium Compounds in Neutral Salt Solutions (중성염 용액 내에서 우라늄으로 오염된 금속성 해체폐기물의 전해제염)

  • 최왕규;이성렬;김계남;원휘준;정종헌;오원진
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.72-80
    • /
    • 2004
  • Electrolytic dissolution study was carried out to evaluate the applicability of electrochemical decontamination process using a neutral salt electrolyte as a decontamination technology for the recycle or self disposal with authorization of large amount of metallic wastes contaminated with uranium compounds generated by dismantling a retired uranium conversion plant using SUS-304 and Inconel-600 specimen as the main materials of internal system components of the plant. The effects of type of neutral salt as an electrolyte, current density, and concentration of electrolyte on the dissolution of the materials were evaluated. On the basis of the results obtained through the basic inactive experiments, electrochemical decontamination tests using the specimens contaminated with uranium compounds such as $UO_2$, AUC (ammonium uranyl carbonate) and ADU (ammonium diuranate) taken from an uranium conversion plant were peformed in $Na_2SO_4$ and $NaNO_3$ solution. It was verified that the electrochemical decontamination of the dismantled metallic wastes was quite successful in $Na_2SO_4$ and $NaNO_3$ neutral salt electrolyte by reducing $\beta$ radioactivities below the level of self disposal with authorization within 10 minutes regardless of the type of contaminants and the degree of contamination.

  • PDF

Effect of Calcium Chloride and Sodium Chloride on the Leaching Behavior of Heavy Metals in Roadside Sediments (염화칼슘과 소금이 도로변 퇴적물의 중금속 용출에 미치는 영향)

  • Lee Pyeong koo;Yu Youn hee;Yun Sung taek
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.4
    • /
    • pp.15-23
    • /
    • 2004
  • Deicer operations provide traffic safety during winter driving conditions in urban areas. Using large quantities of de-icing chemicals (i.e., $CaCl_2$ and NaCl) can cause serious environmental problems and may change behaviors of heavy metals in roadside sediments, resulting in an increase in mobilization of heavy metals due to complexation of heavy metals with chloride ions. To examine effect of de-icing salt concentration on the leaching behaviors and mobility of heavy metals (cadmium, zinc, copper, lead, arsenic, nickel, chromium, cobalt, manganese, and iron), leaching experiments were conducted on roadside sediments collected from Seoul city using de-icing salt solutions having various concentrations (0.01-5.0M). Results indicate that zinc, copper, and manganese in roadside sediments were easily mobilized, whereas chromium and cobalt remain strongly fixed. The zinc, copper and manganese concentrations measured in the leaching experiments were relatively high. De-icing salts can cause a decrease in partitioning between adsorbed (or precipitated) and dissolved metals, resulting in an increase in concentrations of dissolved metals in salt laden snowmelt. As a result, run-off water quality can be degraded. The de-icing salt applied on the road surface also lead to infiltration and contamination of heavy metal to groundwater.

Chemical Changes of Low Salt Gulbi (salted and dried yellow corvenia) during Hot-air Drying with Different Temperatures (저염 굴비 제조 시 열풍건조 온도에 따른 화학적 특성 변화)

  • Gwak, Hyun-Jung;Eun, Jong-Bang
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.2
    • /
    • pp.147-154
    • /
    • 2010
  • Gulbi, made of fresh yellow corvenia (Psendosciaena manchurica) that has been salted and dried, is one of the most popular traditional marine foods in Korea. The objective of this study was to develop a method to safely manufacture Gulbi with low levels of oxidation and contamination, by a hot air drying method. Changes in total acidity, pH, salt concentration, thiobarbituric acid-reactive substance (TBARS) and volatile basic nitrogen (VBN) were measured during drying at 30, 35 and $40^{\circ}C$ for 15 days in a hot air-dryer using a semi-dried method. Acidity increased with increasing drying time at all drying temperatures. The pH decreased gradually with increasing drying time. Salt concentration was increased as drying time increased at all drying temperatures due to moisture loss. The VBN increased as drying time increased for all drying temperatures. Data indicate that the drying at $35^{\circ}C$ appears to have a significant sensory and physicochemical advantage in Gulbi products.

Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent (계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가)

  • Cho, Han-Goo;Lee, Un-Yong;Han, Dong-Hee;Kang, Sung-Hwa;Choi, In-Hyuk;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.1
    • /
    • pp.62-67
    • /
    • 2005
  • Recently, polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. Polymer material is also investigated it's tracking resistance by adding surface active agent in IEC 587. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination, STRI guide and thermal image camera.

A New Type of the Measuring and Anti-Caking Bag for Powder Materials (새로운 형태의 분체용 계량적 Anti-Caking 봉지)

  • Kim, Joong-Man
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.15 no.4
    • /
    • pp.51-55
    • /
    • 1986
  • The general bag for powder materials such as sugar, salt and detergent used at present is a simple rectangular bag. In the practical uses, it has a lot of faults: it is difficult to reseal after partial usages, occurrence of loss in the case of sharing or adding, difficult for measured uses. Author made a new type of the measuring bag for powder materials in order to improve the problems. The new type of the bag for powder materials consists of a body, fall-induced tube with length scale line, and a pin to open and reseal. It shows various effectiveness: measured use$({\pm}0.6g)$ of powder materials, eatings don't occur during long period after opening, and no skin contamination during use of detergent. Consequently, the new one Is suitable for the measured use of powder materials such as sugar, salt, detergent, MSG and so on.

  • PDF

Phase Behavior of the Ternary NaCl-PuCl3-Pu Molten Salt

  • Toni Karlsson;Cynthia Adkins;Ruchi Gakhar;James Newman;Steven Monk;Stephen Warmann
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.1
    • /
    • pp.55-64
    • /
    • 2023
  • There is a gap in our understanding of the behavior of fused and molten fuel salts containing unavoidable contamination, such as those due to fabrication, handling, or storage. Therefore, this work used calorimetry to investigate the change in liquidus temperature of PuCl3, having an unknown purity and that had been in storage for several decades. Further research was performed by additions of NaCl, making several compositions within the binary system, and summarizing the resulting changes, if any, to the phase diagram. The melting temperature of the PuCl3 was determined to be 746.5℃, approximately 20℃ lower than literature reported values, most likely due to an excess of Pu metal in the PuCl3 either due to the presence of metallic plutonium remaining from incomplete chlorination or due to the solubility of Pu in PuCl3. From the melting temperature, it was determined that the PuCl3 contained between 5.9 to 6.2mol% Pu metal. Analysis of the NaCl-PuCl3 samples showed that using the Pu rich PuCl3 resulted in significant changes to the NaCl-PuCl3 phase diagram. Most notably an unreported phase transition occurring at approximately 406℃ and a new eutectic composition of 52.7mol% NaCl-38.7mol% PuCl3-2.5mol% Pu which melted at 449.3℃. Additionally, an increase in the liquidus temperatures was seen for NaCl rich compositions while lower liquidus temperatures were seen for PuCl3 rich compositions. It can therefore be concluded that changes will occur in the NaCl-PuCl3 binary system when using PuCl3 with excess Pu metal. However, melting temperature analysis can provide valuable insight into the composition of the PuCl3 and therefore the NaCl-PuCl3 system.

Screening of Adsorbent to Reduce Salt Concentration in the Plastic Film House Soil under Continuous Vegetable Cultivation (시설채소재배지의 토양특성과 흡착제 종류별 염류경감 효과)

  • Ok, Yong-Sik;Yoo, Kyung-Yoal;Kim, Yoo-Bum;Chung, Doug-Young;Park, Yong-Ha;Yang, Jae-E.
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.3
    • /
    • pp.253-260
    • /
    • 2005
  • Salt accumulation in the plastic film house soils under continuous cultivation condition causes problems such as salt damages to plants, nitrate accumulation in vegetables, groundwater contamination, etc. due to excess application of fertilizers. Objective of this research was to find an optimum adsorbent to reduce salt concentration in the soil solution of plastic film house soils, where crop injuries have been observed due to the salt accumulation. The soils were significantly high in available P $(1,431{\sim}6,516mg\;kg^{-1}),\;NO_3-N\;(117.60{\sim}395.73mg\;kg^{-1})$, exchangeable Ca $(4.06{\sim}11.07\;cmol_c\;kg^{-1})$ and Mg $(2.59{\sim}18.76\;cmol_c\;kg^{-1})$, as compared to those of the average upland soils in Korea. Soils were treated with each of adsorbent such as ion-exchange resin, zeolite, rice bran, etc. at 2% level and prepared into saturated-paste samples. After equilibrium, soil solution was vacuum-extracted from the soil and measured for changes of the pH, EC, and concentrations of $Ca^{2+},\;Mg^{2+},\;K^+,\;Na^+,\;{NH_4}^+,\;{PO_4}^{3-}\;and\;{NO_3}^-$. Rice bran effectively removed ${PO_4}^{3-}\;and\;{NO_3}^-$ in the soil solution up to 100%. Efficiency was decreased in the orders of rice bran > ion-exchange resin > zeolite. Removal efficiencies of zeolite and ion-exchange resin for $Ca^{2+}$ were ranged from 1 to 65% and from 7 to 61%, respectively. Ion-exchange resin was also effective for removing $Mg^{2+},\;K^+,\;Na^+,\;and\;{NH_4}^+$. Overall results demonstrated that rice bran and ion-exchange resin could be applicable for salt accumulated soil to remove the respective anion and cation.

Weathering and Degradation Assessment of Rock Properties at the West Stone Pagoda, Gameunsaji Temple Site, Korea

  • Lee, Chan Hee;Lee, Myeong Seong;Kim, Jiyoung
    • Conservation and Restoration of Cultural Heritage
    • /
    • v.1 no.1
    • /
    • pp.29-37
    • /
    • 2012
  • The West Stone Pagoda at Gameunsaji Temple Site constructed in the 7th century is mainly composed of dark grey dacitic tuff bearing small numerous dioritic xenoliths. These xenoliths resulted in small holes due to differential weathering process from the host rocks. Physical strength of the pagoda was decreased due to weathering and damage caused by petrological, biological and coastal environmental factors. The southeastern part of the pagoda was extremely deteriorated that the rock surface showed exfoliation, fracture, open cavity, granular decomposition of minerals and salt crystallization by seawater spray from the eastern coast. The stone blocks were intersected by numerous cracks and contaminated by subsequent material such as cement mortar and iron plates. Also, the pagoda was colonized by algae, fungi, lichen and bryophytes on the roof rock surface and the gaps between the blocks. As a result of ultrasonic test, the rock materials fell under Highly Weathered Grade (HW) or Completely Weathered Grade (CW). Thus, conservational intervention is essentially required to prevent further weakening of the rock materials.