• 제목/요약/키워드: Safety protection system

검색결과 1,058건 처리시간 0.031초

다양성보호계통 사이버보안 연계 위협 분석 방안 (An Analysis Measure for Cybersecurity linked Threat against Diverse Protection Systems)

  • 정성민;김태경
    • 디지털산업정보학회논문지
    • /
    • 제17권1호
    • /
    • pp.35-44
    • /
    • 2021
  • With the development of information technology, the cybersecurity threat continues as digital-related technologies are applied to the instrumentation and control system of nuclear power plants. The malfunction of the instrumentation and control system can cause economic damage due to shutdown, and furthermore, it can lead to national disasters such as radioactive emissions, so countering cybersecurity threats is an important issue. In general, the study of cybersecurity in instrumentation and control systems is concentrated on safety systems, and diverse protection systems perform protection and reactor shutdown functions, leading to reactor shutdown or, in the worst case, non-stop situations. To accurately analyze cyber threats in the diverse protection system, its linked facilities should be analyzed together. Risk analysis should be conducted by analyzing the potential impact of inter-facility cyberattacks on related facilities and the impact of cybersecurity on each configuration module of the diverse protection system. In this paper, we analyze the linkage of the diverse protection system and discuss the cybersecurity linkage threat by analyzing the availability of equipment, the cyber threat impact of the linked equipment, and the configuration module's cybersecurity vulnerability.

FIRE WATER SYSTEM RELIABILITY IN INDUSTRIAL APPLICATIONS

  • James M. Dewey;Kim, Yong-Dal
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.526-533
    • /
    • 1997
  • Reliability of fire protection systems is often discussed, written about, and even put into codes and standards. However, reliability is seldom considered for the fire protection system as a whole. Why does this happen and why should the designer consider the system as a whole\ulcorner Existing codes and standards incorporate the concept of reliability usually In the form of key component redundancy for some parts of a system. The "Fire Safety Concepts Tree" presented in the National Fire Protection Association Guide 550, Guide to the Fire Safety Concepts Tree, provides a starting point for considering the performance of a water based fire suppression system. Considering fire protection objectives for water based fire suppression systems, means of evaluating system reliability can be developed. This development requires identification of system components that are significant to the overall system reliability.

  • PDF

사무소 건축물의 화재안전 성능 평가모델 (Performance Assessment Model for Fire Safety Protection of Office Building)

  • 양은범;황영삼;이찬식
    • 한국안전학회지
    • /
    • 제19권2호
    • /
    • pp.69-74
    • /
    • 2004
  • This study is to suggest a performance assessment model for fire safety protection of office building 34 asessment elements were chosen by interviewing with experts, reviewing several codes and existing relevant models, assessment elements included in this model are comprised of five categories which are 'performace of protected area', 'performance of fire partition', 'safety performance of fire escape', 'performace of smoke control system' and 'performace of fire fighting equipment'. The weight of each element was computed by systematic approach like an AHP (analytical hierarchy process), which was conducted by experts who work in the field of fire protection. This model would be utilized as a part of assessment model for the overall performace of domestic office building.

무선전력전송 시스템의 모니터링 시스템 구축에 관한 연구 (A Study on Installation of Monitoring System of Wireless Power Transmission System)

  • 송영상;한운기;정진수;임현성;조성구
    • 조명전기설비학회논문지
    • /
    • 제29권4호
    • /
    • pp.47-53
    • /
    • 2015
  • The electrical safety and efficiency is the most important thing of the electric vehicle charging system. The prior system is contact charging system that is contacted directly by human. So, it has riskiness such as electric shock in the case of poor insulation or contact problems. To solve these safety issues and the convenience problems, a wireless power transmission system has been developed and is currently in trial operation. However, because high frequency is used in wireless power transmission system instead of commercial frequency, we need to apply protection measures concerning electric shock and equipment protection. Also, it should be accompanied by measuring efficiency for the effective operation of the wireless power transmission system. Therefore, we structured monitoring system in trial operation area of wireless power transmission system and applied decision algorithm for protection of human and equipment and economic operation of it.

소규모 사업장의 중대재해처벌법 효율적 대응방안 연구 - 중대산업재해 중심 (A Study on the Efficient Countermeasure of the Serious Accidents Punishment Act in the Small Businesses: On the Basis of the Serious Industrial Accidents)

  • 이병림;최유정;유삼열;최재욱
    • 한국재난정보학회 논문집
    • /
    • 제18권3호
    • /
    • pp.507-519
    • /
    • 2022
  • 연구목적: 소규모 사업장에서 중대재해처벌법의 안전보건 확보의무를 준수하는 효율적이고 실무적인 방안을 제시하고자 한다. 연구방법: 문헌연구와 선행연구를 바탕으로 안전보건경영시스템과의 연계, 프로세스 접근방법 등을 활용한 중대재해처벌법 준수방안을 검토하였다. 연구결과: 안전보건경영시스템을 충실히 이행하면 중대재해처벌법의 안전보건 확보의무를 준수할 수 있음을 확인하였다. 그리고 안전보건 확보의무를 이행하고 점검하는 방법론을 제시하였다. 결론: 프로세스 접근방법과 이행점검 체크리스트를 적극 활용하여 안전보건경영시스템을 운영하면 중대재해처벌법 준수는 물론 안전보건경영시스템의 지속적 개선이 가능할 것으로 판단된다.

신뢰성과 유지보수를 위한 원자로보호계통 주기시험 방법 개발 (RPS Periodic Testing Method for Reliability and Availability)

  • 박주현;이동영;이성진;송덕용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.84-86
    • /
    • 2005
  • The digital systems such as PLC or DCS have been applied to non-safety systems of nuclear power plants because of many difficulties in using analog systems. Nowadays, digital systems have been applied to safety systems of the plants such as reactor protection system. One of the main advantages of digital systems is applicability of automatic testing methods to the systems. The protection system requires high-reliability and high-availability because it shall minimize the propagation of abnormal or accident conditions of nuclear power plants. The calculation of reliability and availability of systems depends on the maintenance period of the system. In general, the maintenance period of the protection system is one-month in case of the manual test. However, the cycle of test can be shortened in several hours by using automatic periodic testing. The reliability and availability of the system is better when test period is shortened because the reliability and availability is inverse proportion to the test period. In this research, we developed the automatic periodic testing method for KNICS Reactor Protection System, which can test the system automatically without an operator or a tester. The automatic testing contained all functions of reaction protection systems from analog-to-digital conversion function of the bistable Processor to the coincident trip function of the coincident processor. By applying the automatic periodic testing to reaction system, the maintenance cost can be cut down and the reliability can be increased.

  • PDF

국내 개발된 $N-tox^{(R)}$ 생물검정 시스템을 이용한 시안과 3, 5-이염화페놀의 발광박테리아(Vibrio fischeri)에 대한 혼합 독성 영향 연구 (Toxicity of Binary Mixture of Cyanide and 3,5-dichlorophenol to Vibrio fischeri Determined by Newly Developed $N-tox^{(R)}$ Bioassay System)

  • 이정석;이규태;김찬국;김혜진;이창훈;이종현
    • Environmental Analysis Health and Toxicology
    • /
    • 제22권1호
    • /
    • pp.27-36
    • /
    • 2007
  • Cyanides and dichlorophenols were important pollutants in industrial effluents of steel, petroleum, plastics, pesticides, synthetic dye and/or fiber manufacturing. The toxic effects of cyanide and 3, 5-dichlorophenol in the unary and binary solutions to Vibrio fischeri were determined using the newly developed $N-tox^{(R)}$ bioassay system. This bioassay system relies upon the attenuation of light intensity emitted by Vibrio fischeri exposed to various pollutants including metals and organic compounds. Most of studies dealing with toxicity of pollutants concerned single chemical species, while the organisms were typically exposed to pollutant mixtures. The present study showed that the toxicity of some binary combinations of cyanide and 3, 5-dichlorophenol significantly was lower than the predicted toxicity from the addicted model. This antagonistic interaction was well explained by chemical interaction model presented in this study.

REAL-TIME PERSONAL DOSE MEASUREMENT AND MANAGEMENT SYSTEM RESEARCH IN CHINA

  • Zhang, Z.Y.;Cheng, C.;Liu, Z.S.;Yang, H.T.;Deng, C.M.;Zhang, X.;Guo, Z.J.
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.281-286
    • /
    • 2001
  • The composition and design of a real-time personal dose measurement and management system are described in this paper. Accordingly, some pertinent hardware circuits and software codes including their operation modes have also been presented.

  • PDF

Development of a structure analytic hierarchy approach for the evaluation of the physical protection system effectiveness

  • Zou, Bowen;Wang, Wenlin;Liu, Jian;Yan, Zhenyu;Liu, Gaojun;Wang, Jun;Wei, Guanxiang
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1661-1668
    • /
    • 2020
  • A physical protection system (PPS) is used for the protection of critical facilities. This paper proposes a structure analytic hierarchy approach (SAHA) for the hierarchical evaluation of the PPS effectiveness in critical infrastructure. SAHA is based on the traditional analysis methods "estimate of adversary sequence interruption, EASI". A community algorithm is used in the building of the SAHA model. SAHA is applied to cluster the associated protection elements for the topological design of complicated PPS with graphical vertexes equivalent to protection elements.

유럽 신차 안전도 평가방법을 적용한 보행자 대퇴부 상해 영향 분석 (A Study of Euro NCAP Pedestrian Protection Protocol in Upper Leg Area)

  • 오형준;조한천;김준의;김승기
    • 자동차안전학회지
    • /
    • 제6권1호
    • /
    • pp.16-21
    • /
    • 2014
  • Recently Korea and many countries are legislated for pedestrian protection as following the GTR(Global Technical Regulation). Most NCAP organization have been applying pedestrian protection results in their own rating system in individual or overall rating. Euro NCAP agency has been introduced it first. From the beginning, Euro NCAP had assessed occupant and pedestrian protection. It has become to strengthen a pedestrian protection protocol every time published. Korea NCAP also has been rating pedestrian protection with overall rating system. This paper proposed to study new pedestrian protection protocol especially upper leg in order to find injury response based on physical test. On Euro NCAP, the upper leg injury are assessed two kind of value which are bending moment and force.