• 제목/요약/키워드: Safety Lamp

검색결과 132건 처리시간 0.028초

405 nm 살균용 UV LED 등기구의 청색광 위해에 관한 연구 (Blue-Light Hazards of 405 nm Sterilization LED Lamps)

  • 허현석;김충혁;남기호;김진사
    • 한국전기전자재료학회논문지
    • /
    • 제36권3호
    • /
    • pp.266-274
    • /
    • 2023
  • Recently, sterilization technology has received increasing interest due to the COVID-19 pandemic and required safety precautions. Particularly, sterilization devices using near ultraviolet (UV) with a 405 nm wavelength are also drawing attention. It has a UV-C wavelength and other sterilization effects. Its blue-colored light on the boundary between UV and visible light is used as a light-emitting diode (LED) lamp for 405 nm sterilization, owing to its longer wavelengths than UV rays. However, the 405 nm wavelength contains blue light that can damage the eyes and skin during prolonged exposures and affect the emotional and biological parts of the body. Currently, 405 nm sterilization LED light registers are circulating in the market. However, they have not undergone safety tests for blue-light hazards. Thus, with the active distribution of sterilization LED lights, solid safety standards and management systems are essential to protect users from blue-light hazards. Accordingly, in this study, we conducted spectral radiance and spectral radiative luminance tests on 405 nm sterilization LED registers available in the market by the measurement criteria of IEC 62471. Safety standards must be established to secure users' safety against blue light hazards at a time when 405nm sterilization LED lights are actively distributed due to COVID-19.

Meat Species Identification using Loop-mediated Isothermal Amplification Assay Targeting Species-specific Mitochondrial DNA

  • Cho, Ae-Ri;Dong, Hee-Jin;Cho, Seongbeom
    • 한국축산식품학회지
    • /
    • 제34권6호
    • /
    • pp.799-807
    • /
    • 2014
  • Meat source fraud and adulteration scandals have led to consumer demands for accurate meat identification methods. Nucleotide amplification assays have been proposed as an alternative method to protein-based assays for meat identification. In this study, we designed Loop-mediated isothermal amplification (LAMP) assays targeting species-specific mitochondrial DNA to identify and discriminate eight meat species; cattle, pig, horse, goat, sheep, chicken, duck, and turkey. The LAMP primer sets were designed and the target genes were discriminated according to their unique annealing temperature generated by annealing curve analysis. Their unique annealing temperatures were found to be $85.56{\pm}0.07^{\circ}C$ for cattle, $84.96{\pm}0.08^{\circ}C$ for pig, and $85.99{\pm}0.05^{\circ}C$ for horse in the BSE-LAMP set (Bos taurus, Sus scrofa domesticus and Equus caballus); $84.91{\pm}0.11^{\circ}C$ for goat and $83.90{\pm}0.11^{\circ}C$ for sheep in the CO-LAMP set (Capra hircus and Ovis aries); and $86.31{\pm}0.23^{\circ}C$ for chicken, $88.66{\pm}0.12^{\circ}C$ for duck, and $84.49{\pm}0.08^{\circ}C$ for turkey in the GAM-LAMP set (Gallus gallus, Anas platyrhynchos and Meleagris gallopavo). No cross-reactivity was observed in each set. The limits of detection (LODs) of the LAMP assays in raw and cooked meat were determined from $10pg/{\mu}L$ to $100fg/{\mu}L$ levels, and LODs in raw and cooked meat admixtures were determined from 0.01% to 0.0001% levels. The assays were performed within 30 min and showed greater sensitivity than that of the PCR assays. These novel LAMP assays provide a simple, rapid, accurate, and sensitive technology for discrimination of eight meat species.

지하상가 침수 시 전기설비 전위분포 해석 (The Analysis of Potential Distribution for Submerged Electrical Fittings in an Underground Shopping Street)

  • 정진수;정종욱;김선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2072-2073
    • /
    • 2007
  • This paper describes the analysis of potential distribution and leakage current magnitude around the electrical fittings submerged in an underground shopping street. In the experiment, a couple of electrical utilities(outlet, fluorescent lamp) were submerged in a concrete water bath. The experimental results are expected to be utilized for the risk assessment and the safety countermeasure against the electric shock.

  • PDF

육회와 육사시미에 접종된 Salmonella Typhimurium와 Listeria monocytogenes 검출을 위한 Loop-mediated isothermal amplification와 식품공전의 배지 시험법, real-time PCR의 검출 성능 비교 (Comparison of Loop-mediated Isothermal Amplification and Korea Standard Food Codex (KFSC) Method for Detection of Salmonella Typhimurium, Listeria monocytogenes Artificially Inoculated in Yuk-hwe and Yuk-sashimi)

  • 곽승해;이소영;김진희;오세욱
    • 한국식품위생안전성학회지
    • /
    • 제34권3호
    • /
    • pp.277-282
    • /
    • 2019
  • 본 연구에서는 한국 전통 식품에서 Salmonella Typhimurium와 Listeria monocytogenes의 검출에 대하여 LAMP에 기반한 3M Molecular Detection Assay 2 (3M MDA 2)와 식품공전에 등재된 분리배지, real-time PCR의 검출 성능을 비교하고자 하였다. 육회와 육사시미에 $10^0-10^4CFU/25g$의 수준으로 S. Typhimurium와 L. monocytogenes을 각각 접종하였다. Citrobacter freundii와 Listeria innocua는 S. Typhimurium와 L. monocytogene의 검출에 영향을 주는 균으로 사용하였다. S. Typhimurium와 L. monocytogenes만 $10^0-10^4CFU/25g$ 수준으로 접종한 모든 시료에서는 분리배지, real-time PCR과 LAMP에서 양성으로 검출되었다. C. freundii와 L. innocua를 같이 접종한 경우에서 부분적으로 양성이 나타났다. 육회와 육사시미에 대하여 real-time PCR 보다 3M MDA 2가 더 검출효율이 높음을 알 수 있었다. 분리배지가 가장 검출효율이 높았지만 3M MDA 2와 큰 차이가 없었다. 배지를 사용하는 방법은 최소 일주일의 시간이 소요되고 PCR의 경우 inhibitor의 영향을 많이 받아 정확한 검출이 어려운 점이 있다. 그러나 LAMP에 기반한 3M MDA 2는 enrichment 후 다음 날 간단한 protocol을 통해 25분 이내로 샘플의 양성 반응을 확인할 수 있어 식중독균에 대해 신속하고 정확한 검출이 가능한 것으로 판단되었다.

축사 난방용 할로겐램프의 위험성 및 화재 예방에 관한 연구 (A Study on the Risk of Halogen Lamp for Pigsty Heating and Fire Prevention)

  • 이재경;서승현;이재욱
    • 문화기술의 융합
    • /
    • 제7권3호
    • /
    • pp.553-564
    • /
    • 2021
  • 본 연구에서는 돈사에서의 난방용 할로겐램프의 위험성과 화재 예방에 대하여 분석하였다. 할로겐램프는 경제성과 편의성이 뛰어나 축사 보온에 사용된다. 하지만 안전관리가 허술하고 동물의 움직임에 노출돼 때문에 화재 위험성이 높다. 실제로 오래된 돈사와 축사를 둘러본 결과 화재위험에 노출되어 있음을 쉽게 확인할 수 있었다. 이 점에 주목하여 할로겐램프와의 가연성 물질 접촉 및 사용 부주의로 인한 화재 가능성을 실험을 통해 연구하였다. 실험은 실제 사용환경과 유사한 조건에서 실시되었다. 실제 축사로 사용되는 높이까지 할로겐램프를 설치한 후 바닥에 짚과 톱밥, 왕겨를 두고 적외선 카메라로 온도변화를 관찰했다. 그리고 비정상적인 조건을 가정하여 램프가 바닥에 떨어지거나 인화성 물질이 램프 내부의 유리관에 접촉하는 상태에서 실험을 진행하였다. 할로겐램프를 정상 상태로 사용하면 화재위험은 없었다. 그러나 비정상적인 사용 환경에서는 연기가 나거나 발화하기도 한다. 사용이 편리하거나 활용도가 높은 경우에도 화재위험이 높기 때문에 화재 예방대책이나 사용 규제가 필요하다. 철저한 화재조사와 연구를 통해 화재위험을 알리고 인명피해와 재산피해를 최소화하는 화재 예방을 위해 노력해야 한다.

전국 수은 취급사업장의 작업환경 실태 조사 연구 (A Study of Field Survey on Working Environment for Mercury Treatment Establishments in Korea)

  • 엄성인;백존배;이영섭
    • 한국안전학회지
    • /
    • 제7권3호
    • /
    • pp.30-34
    • /
    • 1992
  • This study is conducted to evaluate the airborne concentration of mercury, as well as installation and efficiency of local exhaust ventilation system for 57 factories manufactured fluorescence lamps, mercury lamps and thermometers for July and August 1990. Results and conclusion are as fellows : 1) Mercury treatment factories are 32 among 57 ones, which are 18 fluorescence lamp manufacturing ones and 6 mercury lamp ones and 3 thermometer ones and 5 other ones. 2) Mean airborne concentrations of mercury for factories manufactured mercury lamps are 0.01 mg/ ㎥ in injection process and 0.0155mg/㎥ in exhaust process, and mean airborne concentration of mercury for factories manufactured thermometer are 0.023mg/㎥ in injection process and 0.012mg/㎥ in selection process. All of these airborne concentrations of mercury are lower than PEL(Permissible Exposure Limit ), 0.05mg/㎥. 3) Mean airborne concentrations of mercury for factories manufactured fluorescence lamps are 0.094mg/㎥ in injection process and 0.087mg/㎥ in exhaust process, and 0.052mg/㎥ in sealing process and 0.085mg/㎥ in other process, respectively. All of these air borne concentrations of mercury are exceeded to PEL. More than 60% among 32 factories manufactured mercury are exceeded to PEL. 4) Nine factories among 18 factories manufactured fluorestence lamps are equipped with local exhaust ventilation system, and 7 factories among 9 factories are required for the improvement of suction capacity and structure. Five factories among 14 factories manufactured mercury lamps and the other ones are equipped with local exhaust ventilation system, and 2 factories are required for the improvement of suction capacity and structure.

  • PDF

자동점멸식 보안등 점검함 개발 (Development of an Inspection Box for a Guard Lamp with an Automatic Switch)

  • 정종욱;정진수;김선구
    • 조명전기설비학회논문지
    • /
    • 제22권10호
    • /
    • pp.34-40
    • /
    • 2008
  • 본 논문에서는 최근 증가 일로에 있는 자동점멸식 보안등에 대한 안전점검 방안을 제시하였다. 기술적인 측면으로서 보안등주의 하부에 안전점검을 위한 별도의 점검함을 설치하고 점검원이 누설전류, 누전차단기의 정상적인 동작 상태, 절연저항 및 접지저항을 승주하지 않고 측정할 수 있도록 하였으며, 충전부에 대한 직접 접촉의 가능성을 최대한으로 경감함으로써 감전의 위험으로부터 자유로울 수 있도록 설계하였다. 본 연구의 결과물을 실용화함으로써 보안등에 대한 점검을 최대한 안전하고 효율적으로 수행하는데 일조할 수 있을 것으로 기대한다.

즉석섭취식품에 존재하는 Salmonella spp.와 Listeria monocytogenes의 검출을 위한 SureTectTM와 표현형 및 유전자형 방법의 비교 (Comparison of SureTectTM with phenotypic and genotypic method for the detection of Salmonella spp. and Listeria monocytogenes in ready-to-eat foods)

  • 변계환;김병후;조아진;허은;윤성희;김태익;하상도
    • 한국식품저장유통학회지
    • /
    • 제30권2호
    • /
    • pp.262-271
    • /
    • 2023
  • 본 연구에서는 real-time PCR(SureTectTM kit와 PowerChekTM kit), LAMP(3M MDS), 선택 배지를 이용하여 즉석섭취식품에 존재하는 Salmonella spp.와 L. monocytogenes의 검출 능력을 비교 및 평가하고 식품 매트릭스가 real-time PCR의 결과에 미치는 영향을 조사하였다. 4가지 서로 다른 농도로 접종된 식품을 동일한 증균배지를 이용하여 증균 후 세 가지 방법으로 검출한 결과, real-time PCR, LAMP, 선택 배지에서 모두 양성으로 검출되어 인위적으로 접종된 식품에서의 검출 성능은 동등한 것으로 나타났다. 또한, 식품 매트릭스가 real-time PCR의 신속 검출에 미치는 영향을 조사한 결과, Salmonella spp.의 검출에서 샐러드가 다른 식품에 비해 Ct value가 유의적으로 높은 것으로 나타나, 섬유질이 풍부한 식품에 존재하는 Salmonella spp.의 검출을 위해서는 충분한 균질화와 균체의 탈리, 그리고 효율적인 DNA의 증폭이 필요함을 알 수 있었다. 반면, L. monocytogenes의 검출은 식품 매트릭스마다 상이하며 혼합적인 양상을 보였다. 현재의 식품공전 규정에서 식품에 존재하는 식중독균의 신속 검출을 위한 장비와 시약의 사용은 대부분 사용자의 선택에 의존하고 있다. 본 실험에서 real-time PCR로 사용된 SureTectTM kit와 PowerChekTM kit는 기존 real-time PCR kit의 대체재로서 사용이 가능할 것으로 판단되며, 또한, LAMP도 우수한 검출 성능을 보였기에 식품안전 관리 수단으로 활용될 가능성이 있음을 시사하고 있다.

Development of a Screening Method and Device for the Detection of Escherichia coli from Agri-Food Production Environments and Fresh Produce

  • Yun, Bohyun;An, Hyun-Mi;Shim, Won-Bo;Kim, Won-Il;Hung, Nguyen Bao;Han, Sanghyun;Kim, Hyun-Ju;Lee, Seungdon;Kim, Se-Ri
    • Journal of Microbiology and Biotechnology
    • /
    • 제27권12호
    • /
    • pp.2141-2150
    • /
    • 2017
  • This study was conducted to develop a screening method using Colilert-18 and a device for the detection of E. coli from agri-food production environments and fresh vegetables. The specificity and sensitivity of Colilert-18 by temperature ($37^{\circ}C$ and $44^{\circ}C$) were evaluated with 38 E. coli and 78 non-E. coli strains. The false-positive rate was 3.8% (3/78) and 0% (0/78) at $37^{\circ}C$ and $44^{\circ}C$, respectively. The detection limit of E. coli at $37^{\circ}C$ at <1.0 log CFU/250 ml was lower than that at $44^{\circ}C$. The efficiency of the developed device, which comprised an incubator equipped with a UV lamp to detect E. coli in the field, was evaluated by measuring the temperature and UV lamp brightness. The difference between the set temperature and actual temperature of the developed device was about $1.0^{\circ}C$. When applying the developed method and device to various samples, including utensils, gloves, irrigation water, seeds, and vegetables, there were no differences in detection rates of E. coli compared with the Korean Food Code method. For sanitary disposal of culture samples after experiments, the sterilization effect of sodium dichloroisocyanurate (NaDCC) tablets was assessed for use as a substitute for an autoclave. The addition of one tablet of NaDCC per 50 ml was sufficient to kill E. coli cultured in Colilert-18. These results show that the developed protocol and device can efficiently detect E. coli from agri-food production environments and vegetables.

교통안전시설 설치의 교통사고 발생에 대한 선행성 분석 (Precedence Analysis of Traffic Safety Facilities Installation for Traffic Accidents)

  • 주일엽
    • 시큐리티연구
    • /
    • 제55호
    • /
    • pp.31-55
    • /
    • 2018
  • 본 연구는 교통안전표지, 교통신호기기 등 교통안전표지 설치의 교통사고 발생에 대한 선행성을 분석하는데 목적이 있다. 시계열분석(time series analysis) 중 하나인 교차상관분석(cross-correlation analysis)을 실시하여 도출한 주요 연구결과는 다음과 같다. 첫째, 교통안전시설 설치건수의 교통사고 발생건수에 대한 선행성은 교통안전표지(전체) 설치건수(시차수 1), 교통안전표지(주의) 설치건수(시차수 7), 교통안전표지(규제) 설치건수(시차수 7), 교통안전표지(지시) 설치건수(시차수 4)가 각각 부(-)의 관계로 교통사고 발생건수를 선행(先行)한다. 둘째, 교통신호기기 설치건수의 교통사고 발생건수에 대한 선행성은 교통신호기기(보행등) 설치건수(시차수 2)가 부(-)의 관계로 교통사고 발생건수를 선행(先行)한다. 셋째, 교통안전시설 설치건수 증감률의 교통사고 발생 증감률에 대한 선행성은 교통안전표지(전체) 설치 증감률(시차수 1), 교통안전표지(주의) 설치 증감률(시차수 1), 교통안전표지(지시) 설치 증감률(시차수 1), 교통안전표지(보조) 설치 증감률(시차수 1)이 각각 부(-)의 관계로 교통사고 발생 증감률을 선행(先行)한다. 넷째, 교통신호기기 설치 증감률의 교통사고 발생 증감률에 대한 선행성은 교통신호기기(보행등) 설치 증감률(시차수 0)이 정(+)의 관계로 동행(同行)한다.