• Title/Summary/Keyword: SV2

Search Result 702, Processing Time 0.027 seconds

The Evaluation and Development of Head and Neck Radiation Protective Device for Chest Radiography in 10 Years Children (소아(10세) 흉부 방사선촬영에서의 두경부 방사선 방어기구 개발 및 평가)

  • Lee, Jun Ho;Lim, Hyun Soo;Lee, Seung Yeol
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.118-123
    • /
    • 2015
  • The frequency of diagnostic radiation examinations in medical institutions has recently increased to 220 million cases in 2011, and the annual exposure dose per capita was 1.4 mSv, 51% and 35% respectively, compared to those in 2007. The number of chest radiography was found to be 27.59% of them, the highest frequency of normal radiography. In this study, we developed a shielding device to minimize radiation exposure by shielding areas of the body which are unnecessary for image interpretation, during the chest radiography. And in order to verify its usefulness, we also measured the difference in entrance surface dose (ESD) and the absorbed dose, before and after using the device, by using an international standard pediatric (10 years) phantom and a glass dosimeter. In addition, we calculated the effective dose by using a Monte Carlo simulation-based program (PCXMC 2.0.1) and evaluated the reduction ratio indirectly by comparing lifetime attributable risk of cancer incidence (LAR). When using the protective device, the ESD decreased by 86.36% on average, nasal cavity $0.55{\mu}Sv$ (74.06%), thyroid $1.43{\mu}Sv$ (95.15%), oesophagus $6.35{\mu}Sv$ (78.42%) respectively, and the depth dose decreased by 72.30% on average, the cervical spine(upper spine) $1.23{\mu}Sv$ (89.73%), salivary gland $0.5{\mu}Sv$ (92.31%), oesophagus $3.85{\mu}Sv$ (59.39%), thyroid $2.02{\mu}Sv$ (73.53%), thoracic vertebrae(middle spine) $5.68{\mu}Sv$ (54.01%) respectively, so that we could verify the usefulness of the shielding mechanism. In addition, the effective dose decreased by 11.76% from $8.33{\mu}Sv$ to $7.35{\mu}Sv$ before and after wearing the device, and in LAR assessment, we found that thyroid cancer decreased to male 0.14 people (95.12%) and female 0.77 people (95.16%) per one million 10-year old children, and general cancers decreased to male 0.14 people (11.70%) and female 0.25 people (11.70%). Although diagnostic radiation examinations are necessary for healthcare such as the treatment of diseases, based on the ALARA concept, we should strive to optimize medical radiation by using this shielding device actively in the areas of the body unnecessary for the diagnosis.

A combination of postmortem ageing and sous vide cooking following by blowtorching and oven roasting for improving the eating quality and acceptance of low quality grade Hanwoo striploin

  • Jwa, Seung-Hoon;Kim, Yong-An;Hoa, Van-Ba;Hwang, In-Ho
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.8
    • /
    • pp.1339-1351
    • /
    • 2020
  • Objective: It is well recognized that beef cuts from a low quality grade are usually associated with tougher, drier and less flavorful. Thus, the present study aimed at investigating the combined effects of postmortem ageing and sous vide (SV) cooking followed by oven roasting or blowtorching on the eating quality of low quality grade Hanwoo beef striploins. Methods: Hanwoo beef striploins (quality grade 3) obtained from 36 month-old Hanwoo steers were used, and the samples were chiller aged for 0 and 14 d at 4℃. After ageing, the samples were prepared into 2.5-cm steaks which were then SV cooked at 55℃ for 5 h and then raised to 60℃ for 1 h, and thereafter the SV-cooked the steaks were further roasted in oven for 20 min (SV+OV) or blowtorched (SV+TC) for 2 min. The cooked samples were analyzed for microbiological quality, browning index, Wanrner-Bratzler shear force (WBSF), aroma flavor compounds and sensory properties. Results: The SV cooking significantly reduced the WBSF values in beef samples (p<0.05). Blowtorching after SV cooking led to a browner surface of the beef steaks (p<0.05). The samples treated with SV+OV or SV+TC exhibited higher levels of Maillard reaction-derived aroma flavor compounds such as; pyrazines and sulfur-containing compounds compared to those just SV cooked. More especially, the SV+OV- or SV+TC- treated samples presented significantly higher flavor and overall acceptability scores compared to those just SV cooked (p<0.05). Ageing beef for 14 d significantly improved the tenderness by reducing the WBSF and increasing the tenderness scores. Conclusion: Thus, the combination of postmortem ageing and SV cooking followed by additional treatments (blowtorching or oven roasting) could be used to improve the eating quality especially tenderness and flavor as well as overall acceptability of low grade Hanwoo beef.

Dose evaluation of workers according to operating time and outflow rate in a spent resin treatment facility

  • Byun, Jaehoon;Choi, Woo Nyun;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3824-3836
    • /
    • 2021
  • Workers' safety from radiological exposure in a 1 ton/day capacity spent resin treatment facility was evaluated according to the operating times and outflow rate due to process related leakages. The conservative annual dose based on the operating times of the workers exceeded the dose limit by at least 7.38E+01 mSv for close work. The realistic dose range was derived as 1.62E+01 mSv-6.60E+01 mSv. The conservative and realistic annual doses for remote workers were 1.33E+01 mSv and 3.00E+00 mSv respectively, which were less than the dose limit. The MWR was identified as the major contributor to worker exposure within the 1 h period required for removal of radioactive materials. The dose considering both internal and external exposures without APF was derived to be 1.92E+01 mSv for conservative evaluation and 4.00E+00 mSv for realistic evaluation. Furthermore, the dose with APF was derived as 7.27E-01 mSv for conservative evaluation and 1.51E-01 mSv for realistic evaluation. Considering the APF for leakage from all parts, the dose range was derived as 1.25E+00 mSv-2.03E+00 mSv for conservative evaluation and 2.61E-01 mSv-4.23E-01 mSv for realistic evaluation. Hence, it was confirmed that radiological safety was secured in the event of a leakage accident.

Medical Radiation Exposure Dose of Workers in the Private Study of the Job Function (의료기관 방사선 종사자의 직무별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.3-12
    • /
    • 2011
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: From January 1, 2010 December 31, 2010, medical practitioners working in the radiation is classified as a regular personal radiation dosimetry, and subsequently one year 540 people managed investigation department to target workers, dose sectional area, working period, identify the job function-related tasks for a deep dose, respectively, the annual average radiation dose were analyzed. Frequency analysis methods include ANOVA was performed. Results: Medical radiation workers in the department an annual radiation dose of Nuclear and 4.57 mSv a was highest, dose zone-specific distribution of nuclear medicine and in the 5.01~19.05 mSv in the high dose area distribution showed departmental radiation four of the annual radiation dose of Nuclear and 7.14 mSv showed the highest radiation dose. More work an average annual radiation dose according to the job function related to the synthesis of Cyclotron to 17.47 mSv work showed the highest radiation dose, Gamma camera Cinema Room 7.24 mSv, PET/CT Cinema Room service is 7.60 mSv, 2.04 mSv in order of intervention high, were analyzed. Working period, according to domain-specific average annual dose of radiation dose from 10 to 14 in oral and maxillofacial radiology practitioners as high as 1.01~3.00 mSv average dose showed the Department of Radiology, 1-4 years, 5-9 years, respectively, 1.01 workers~8.00 mSv in the range of the most high-dose region showed the distribution, nuclear medicine, and the 1-4 years, 5-9 years 3.01~19.05 mSv, respectively, workers of the highest dose showed the distribution of the area in the range of 10 to 14 years, Workers at 15-19 3.01~15.00 mSv, respectively in the range of the high-dose region were distributed. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

Elementary School in Gwangju Gwangsan Radon gas Density Measurement (광주광역시 광산구 소재 초등학교 라돈가스 농도 계측)

  • Ahn, Byungju;Oh, Jihoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.211-216
    • /
    • 2014
  • Radium is rock or soil of crust or uranium of building materials after radioactivity collapse process are created colorless and odorless inert gas that accrue well in sealed space like basement. It inflow to lung circulate respiratory organ and caused lung cancer because of deposition of lung or bronchial tubes. In this study, the air in the elementary school classroom nongdoeul tonkatsu place of measured values were compared using the calculated annual internal radiation exposure. La tonkatsu exposure measured in primary school classroom at least five schools when you close the windows in the average floor 0.56mSv 2 floors ground floor windows when opened 0.384mSv 048mSv 3 floors, 2 floor levels of the same three layers 0.31mSv 0.296mSv the human exposure to radon and radiation on the first floor of 3 floors above ground in a lot of exposure was moderate. When you close the window from the first floor up 0.384mSv 056mSv 3 floors with a minimum annual radiation exposure due to natural radiation in the 16 to 23.3 percent minimum 2.4mSv accounted for. When I opened the window to the maximum annual radiation exposure 2.4mSv 0.296mSv 0.31mSv least a minimum of 12.3 to 12.91% accounted for Results suggest that more than five chodeunghakgyoeun La tonkatsu domestic radon measurements conducted below regulatory requirements and internal exposure has also fall within the normal range. People The less the radiation exposure to the human body because it reduces the impact in the classroom in elementary school vent windows often reduced to the maximum radon concentration in the air, if called tonkatsu be able to reduce radiation exposure for the immune system is weak and elementary will be helpful to experiment more in the future for the school authorities called tonkatsu investigation is done to him if the action to establish a more secure school building facilities is thought would be helpful.

An Analysis of the Radiation Exposure of Radiologic Technologists in the Field of Diagnostic Radiology according to Duty Station (방사선 진단영역에서 방사선사의 부서별 의료피폭의 분석)

  • Han, Jae-Jin;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.71-75
    • /
    • 1997
  • This study was Investigation that we will become aware of the scattering dose of duty station and TLD value of the radiation exposure by the radiation technologists based on the university hospital located in Kwang ju. The results are followings ; 1. The air of scattering dose in chest, when the number of objects are large, is 2.0 mR in P-A and 4.6 mR in Lat. at the back of X-ray tube 2. Radiologists, radiation exposure in duty station Is 0.22 mSv to 1.96 mSv in general examination, 0.22 mSv to 1.12 mSv in contrast and special examination, 0.26 mSv to 30.96 mSv in angiography, and 0.22 mSv to 0.40 mSv in C.T 3. The value of workig condition reveals 85.5% in general examination, 6% in contrast and special examination, and 5.8% in C.T. When the annual exposure is over 20 mSv, it must be measured again according to ICRP public 60.

  • PDF

Effects of Snake Venom Pharmacopuncture on a Mouse model of Cerebral Infarction

  • Choi, Chul-Hoon;Song, Ho-Sueb
    • Journal of Acupuncture Research
    • /
    • v.36 no.3
    • /
    • pp.140-146
    • /
    • 2019
  • Background: This study investigated the effects of Vipera lebetina turanica snake venom (SV) on cerebral infarction induced by middle cerebral artery occlusion in mice. Methods: Following cerebral infarction, SV was injected intravenously or added to BV2 cell culture. Tissue injury was detected using triphenyltetrazolium chloride (TTC) staining, neurological deficit score, NO, ROS, and GSH/GSSG assays, qPCR, Western blot, and cell viability. Results: Cerebral infarction caused by middle cerebral artery occlusion as observed by TTC staining, showed SV inhibited cell death, reducing the number of brain cells injured due to infarction. SV treatment for cerebral infarction showed a significant decrease in abnormal behavior, as determined by the neurological deficit score. The oxidation and inflammation of the cells that had cerebral infarction caused by middle cerebral artery occlusion (NO assay, ROS, GSH/GSSG assay, and qPCR), showed significant protection by SV. Western blot of brain infarction cells showed the expression of iNOS, COX-2, p-IkB-${\alpha}$, P38, p-JNK, p-ERK to be lower in the SV group. In addition, the expression of IkB increased. BV2 cells were viable when treated with SV at $20{\mu}g/mL$ or less. Western blot of BV2 cells, treated with 0.625, 1.5, $2.5{\mu}g/mL$ of SV, showed a significant decrease in the expression of p-IkB-${\alpha}$, p-JNK, iNOS, and COX-2 on BV2 cells induced by LPS. Conclusion: SV showed anti-inflammatory and anti-oxidant effects against cerebral infarction and inflammation.

Proporties of SV4O-transformed Human Cells (SV40 바이러스로 형질전환된 사람종양세포의 특성)

  • 최경희;홍승환
    • The Korean Journal of Zoology
    • /
    • v.31 no.1
    • /
    • pp.49-55
    • /
    • 1988
  • A few SV4O-transformed human cells such as SV8O are potentially tumorigenic but rejected by athymic hosts. However, one cell line in this group (W118IVA-2) is known to be fully tumorigenic. Two clones were obtained after the injection of W118IVA-2, of which NW1SC1-1 was tumorigenic but NW18C1-2 was not in nude mice. As examined by Southern blot analysis, NW18C1-1 appears to contain more copy number of SV40 sequences than NW18C1-2 does. However, it was unable to demonstrate that this difference elicits the tumorigenicity in NW18C1-1 but not in NW18C1-2. Therefore, the latter clone was tested if it expresses SV40 early genes to produce large T as well as small t antigens using indirect immunofluorescent assay and immunoprecipitation. In addition, mouse NIH3T3 cells were transfected with the cellular DNA of NW1SC1-2 as well as that of NW18C1-1 to examine if the viral genomes in the clones can make the nontransformed cells to acquire malignant growth potential in vivo. The transformed cells expressed large T antigen and became tumorigenic. Thus, the transforming functions of NW1SC1-2 cell appers to be intact. These results clearly suggest that the inability of NW18C1-2 cell to form tumor in nude mice is not because they are inherently nontumorigenic. However, the possibility that the interaction of SV40 with its host differs in these clones can not he ruled out.

  • PDF

Effect of Viral Enhancers on the Tissue-Specific Expression of Bovine Growth Hormone Gene (소성장호르몬 유전자의 조직 특이성 발현에 미치는 바이러스 engancer의 영향)

  • 박계윤;김수미;노정혜
    • Korean Journal of Microbiology
    • /
    • v.27 no.2
    • /
    • pp.85-91
    • /
    • 1989
  • The effect of SV40 and murine cytomegalovirus (MCMV) enhancers on the general and tissue-specific gene expression was investigated. Recombinant plasmids containing these transcriptional engancers downstream of a structural gene for chloramphenicol acetyl transferase (CAT) were constructed. The transient expression of CAT gene from these plasmids was measured in monkey (CV1PD) and HeLa cells. Both SV40 and MCMV engancers activated the expression of CAT gene by more than 20 and 150 folds, respectively, compared with engancerless plasmids. When the SV40 promoter, upstream of CAT gene, was replaced with 2.2 kbp of promoter regulatory region of bovine growth hormone (bGH) gene, there was no expression of CAT even in the presence of enhancers, reflecting the tissue-specific expression of bGH genes. However, when the bGH regulatory region was shortened to 230 bp, the expression level increased dramatically in the presence of SV40 enhancers. In contrast, the expression from the shortened promoter was only marginally activated by the stronger MCMV enhancer.

  • PDF

Dosimetric Quantities for 300 keV Neutrons (300 keV 중성자(中性子)에 대한 방사선량(放射線量) 관계량(關係量)의 산정(算定))

  • Lee, Soo-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.37-43
    • /
    • 1986
  • Dosimetric quantities for 300 keV neutrons in the ICRU standard tissue sphere were evaluated. The Monte Carlo code NEDEP which performs neutron-photon-charged particles coupled transport was used in the direct estimation of absorbed dose and dose equivalent. Some important quantities calculated are as follows; Deep dose equivalent index $H_{I,d}:1.78{\times}10^{11}\;Sv-cm^2$ Shallow dose equivalent index $H_{I,s}:2.08{\times}10^{-11}\;Sv-cm^2$ Ambient dose equivalent $H^*(0.07):1.7{\times}10^{-11}\;Sv-cm^2$ Ambient dose equivalent $H^*(10):1.78{\times}10^{-11}\;Sv-cm^2$ Effective quality factor $\bar{Q}^*(10):12.4$

  • PDF