Dosimetric Quantities for 300 keV Neutrons

300 keV 중성자(中性子)에 대한 방사선량(放射線量) 관계량(關係量)의 산정(算定)

  • Lee, Soo-Yong (Department of Physics, College of Science and Engineering, Hanyang University)
  • 이수용 (한양대학교 이공대학 물리학과)
  • Published : 1986.06.20

Abstract

Dosimetric quantities for 300 keV neutrons in the ICRU standard tissue sphere were evaluated. The Monte Carlo code NEDEP which performs neutron-photon-charged particles coupled transport was used in the direct estimation of absorbed dose and dose equivalent. Some important quantities calculated are as follows; Deep dose equivalent index $H_{I,d}:1.78{\times}10^{11}\;Sv-cm^2$ Shallow dose equivalent index $H_{I,s}:2.08{\times}10^{-11}\;Sv-cm^2$ Ambient dose equivalent $H^*(0.07):1.7{\times}10^{-11}\;Sv-cm^2$ Ambient dose equivalent $H^*(10):1.78{\times}10^{-11}\;Sv-cm^2$ Effective quality factor $\bar{Q}^*(10):12.4$

ICRU 구(球)를 피사체(被射體)로 하여 300 keV 중성자(中性子)의 방사선량(放射線量) 관계량(關係量)을 평가(評價)하였다. 피사체내(被射體內)의 선량당량(線量當量) 분포(分布)를 직접(直接) 산정(算定)하기 위해 중성자(中性子)-광자(光子)-하전입자(荷電粒子) 결합수송(結合輸送)을 다룰 수 있는 몬테칼로 코드 NEDEP을 사용하였다. 계산결과(計算結果) 얻은 방사선량(放射線量) 관계량(關係量)은 다음과 같다. 심부선량당량지수(深部線量當量指數) $H_{I,d}:1.78{\times}10^{11}\;Sv-cm^2$ 표층선량당량지수(表層線量當量指數) $H_{I,s}:2.08{\times}10^{-1}\;Sv-cm^2$ 주위선량당량(周圍線量當量) $H^*(0.07):1.70{\times}10^{-11}\;Sv-cm^2$ 주위선량당량(周圍線量當量) $H^*(10):1.78{\times}10^{-11}\;Sv-cm^2$ 실효선질계수(實效線質係數) $\bar{Q}^*(10):12.4$

Keywords