• Title/Summary/Keyword: SUN TEST

Search Result 7,541, Processing Time 0.035 seconds

An Evaluation of the Statistical Techniques Used in the 1995-2007 Editions of the Korea Institute of Oriental Medicine (한국한의학연구원 논문집에 사용된 통계기법의 평가)

  • Kang, Kyung-Won;Kang, Byung-Gab;Go, Mi-Mi;Shin, Sun-Hwa;Choi, Sun-Mi
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.2 s.20
    • /
    • pp.121-125
    • /
    • 2007
  • Background and Purpose : The purpose of this study was done to investigate what kinds of statistical techniques have been used to analyze data from oriental medicine research Methods : 135 original articles which used statistical techniques in their data analysis were selected from the articles published in The Journal of Korea Institute of Oriental Medicine(JKIOM) between 1995 to 2007. Results : Among 135 articles, 59 articles used descriptive statistics while 76 articles used inferential statistics for data analysis. For that 76 articles, two-sample t-test(33 articles), analysis of variance(29 articles), regression(9 articles), chi-square test(5 articles), nonparametic test(4 articles), Fisher's exact test(3 articles), and other test(9 articles) were chosen to analyze the data. SAS and SPSS statistical softwares(82.50%) were mostly used to analyze the data. Nonparametic tests were used to 4 articles(6.97%) of 67 articles and parametic tests were used to 63 articles(93.03%) of 67 articles. Among 29 articles used analysis of variance, duncan(8 articles), dunnet(4 articles), bonferroni(4 articles), turkey(3 articles), scheff(1 article) were used to do multiple comparison. 9 articles did not carry out the multiple comparison. Conclusions : It was found that the frequencies of statistical package used and statistical analysis used were not much by now. High level statistical analyses were not used most for oriental medicine research.

  • PDF

The field-test of Power Quality Meter and Power Management System in order to verify the performance (PQM 및 PQMS 성능검증을 위한 실증시험)

  • Choi, Sun-Kyu;Song, Il-Keun;Kwon, Tae-Ho;Han, Jae-Wook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.235-239
    • /
    • 2005
  • This paper gives a field-test method and result of PQM(Power Quality Meter) and PQMS(Power Quality Management System). The field-test was carried out as our own method. So, the test method has several kinds of improvement in this paper because it is first time to try the field-test of the equipment. However, we expect that the test result of PQM & PQMS has been used as a reference data which makes a scheme of evaluating performance of the equipment that has been used or is developed.

  • PDF

Korean Auditory Discrimination Test (한국어 청취 판별 검사)

  • Lee Hyun Bok;Kim Sun Hee
    • MALSORI
    • /
    • no.33_34
    • /
    • pp.91-98
    • /
    • 1997
  • Auditory discrimination which represents a very basic and important perceptual skill in children is a necessary condition for effective learning. It is necessary, therefore, to devise a standardized test tool for a reliable assessment of the auditory discrimination ability of children. The Korean Auditory Discrimination Test(KADT) is a tentative test tool that the authors have devised to meet such demand, i.e., to test the auditory discrimination ability of Korean children, both normal and hearing- and speech-impaired, between the ages of 4 and 8. The KADT consists of 40 pairs of words arranged in a systematic manner, of which thirty are 'minimal pairs' of words and the rest homophonous synonyms. The 30 minimal pairs are composed in such a way that major phonological contrasts involving consonants and vowels at initial, medial and final positions are duly represented. The test score will be determined by the number of right responses made by the children. Further attempts will be made to refine and improve KADT in future.

  • PDF

Computer Programs for Nonparametric Tests (비모수적(非母數的) 통계(統計) 프로그램의 개발(開發))

  • Bae, Do-Seon;Jang, Jung-Sun;Kim, Sang-Bok
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.12 no.2
    • /
    • pp.101-108
    • /
    • 1986
  • Computer programs for IBM PC/XT/AT or compatibles, are presented for running 9 nonparametric tests. They include sign test, Wilcoxon signed rank test, Mann-Whitney Wilcoxon test, Kruskal-Wallis test, Kolmogorov-Smirnov one sample and two sample tests, Kendall and Spearman rank correlation coefficient tests, and Chi square test for contingency table. Each program is written with BASIC language and is combined into a statistical package, 'NONPARA'. It is easily accessible through the menu programs. The alogorithms on which each test is based, are also explained and 3 examples are given.

  • PDF

Korean Standard Draft of the Laboratory Method of Measuring the Airborne Sound Insulation of a Suspended Ceiling (천장속 공간을 공유하는 매단 천장의 실간 공기전달음 차단성능 측정방법의 KS규격화 방안)

  • Yang, Kwan-Seop;Lee, Keun-Hee;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.956-960
    • /
    • 2002
  • Offices and other multipurpose buildings commonly have suspended ceilings installed over room dividing wall. But Korean Standards don't include any code on test methods and test facility of the suspended ceiling system. Therefore, test methods and test facility from ISO and ASTM have been used for evaluating sound performance in domestic so fu. In this study, Korean Standards draft on test methods and test facility of suspended ceiling system and materials is proposed on the basis of ISO and ASTM.

  • PDF

Statistical analysis of the energy for cable cutting (케이블 절단에 필요한 에너지 통계적 분석)

  • Choi, Chang-Sun;Kang, Won-Kyu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.400-403
    • /
    • 2011
  • We performed Instron and Impact tests to estimate necessary explosive charge weight for cutting the cable whose diameter is 22 mm. The cutting energy measured by Instron was 21.3 J. Impact test were performed 8 times each at 5 different energies. The Impact test results were analysed by Probit methods. The cutting energy was calculated 37.7 J with 99.99% probability at 99% confidence, which is roughly equivalent to 250 mg of Zirconium potassium Perchlorate (ZPP).

  • PDF

A study on the aging characteristics for model III watthour meters (보통전력량계(III 형)의 경년변화 특성연구)

  • Kim, Young-Lae;Hong, Sun-Hak;Park, Ku-Perm;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.9-12
    • /
    • 1993
  • This study investigated the propriety and the extension of the term of validity about the using watthour meters at present. The subject of study is 1Cent 2W 220V 30(10)A, 1Cent 3W 110V 30(10)A of model III watthour meters. They are the used metes(products in 1984) and the repaired meters(products in 1977) in the end of the period. The investigation is as follows. o Investigation of external appearance o Driving current test o Creeping test o Noise test o Error test o Durability test. Results of the study have been the number of 13.3% exceeded permitting error and the number of 31.3% failed in endurable test of 500 hours. So, the using meters are not suitable to extend the term of validity without the improvement of several characteristics.

  • PDF

Hydrodynamic Performance Test of a Turbopump Assembly (터보펌프 조립체의 수력 성능 시험)

  • Hong, Soon-Sam;Kim, Dae-Jin;Kim, Jin-Sun;Kim, Jin-Han
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.4
    • /
    • pp.249-254
    • /
    • 2008
  • Hydrodynamic performance test of a turbopump for a liquid rocket engine is carried out. The turbopump is composed of an oxidizer pump, a fuel pump and a turbine, and the two pumps are driven by the turbine. In the test, water is used for the pumps as working media and air is used for the turbine. Performance parameters of pumps and a turbine are drawn, and a power balance between the pumps and the turbine are calculated. The calculation shows a good power balance, which implies that the pump component tests, the turbine component test and the assembly test are reliably performed. At the starting period of the test, pressure rise-flow rate curve of a pump gradually approaches the ideal curve which could be obtained by very slow starting.

A Study on Chemical Resistance Test Method of the Adhesively Flexible Rubberized Injection Seal for Water Leakage Cracks in Concrete Structures (점착유연형 고무 아스팔트계 누수보수용 주입형 실링재의 내화학 시험방법 개선 연구)

  • Park, Wan-Goo;Kim, Dong-Bum;Park, Jin-Sang;Kim, Sun-Do;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.240-241
    • /
    • 2017
  • In this stduy, we will references to provide reasonable basis for the test environments applicable to the chemical resistance test covered by KS F 4935 『Injection-type Sealing Materials for Water Leakage Crack of Adhesive and Flexible Rubber Asphalt』, analyze the problems with the current test methods in consideration of the features of materials. As a result, we assured more objective data in improved chemical resistance test methods.

  • PDF

Hydraulic Performance Test of a Turbopump Inducer in Liquid Nitrogen (액체질소를 이용한 터보펌프 인듀서의 수력성능시험)

  • Kim, Jin-Sun;Hong, Soon-Sam;Kim, Jin-Han
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.348-353
    • /
    • 2005
  • A cryogenic test facility has been developed to perform inducer and pump tests using liquid nitrogen. Performance tests of a turbopump in the maximum 50ton-thrust class can be performed with cryogenic fluid in the facility which operates at a temperature around $-196^{\circ}C$ with the rotational speed up to 30,000rpm. To verify the reliability of the cryogenic pump test facility, hydraulic performance tests of an inducer were accomplished, and their results were compared with the result from a water test The results confirm the reliability of the cryogenic test facility, and it is expected to contribute for on-going development of a turbopump for liquid rocket engines.

  • PDF