• Title/Summary/Keyword: STI index

Search Result 35, Processing Time 0.02 seconds

The Effect of the Disturbing Wave on the Speech Intelligibility of the Eavesdropping Sound of a Window Glass (교란파가 유리창 진동음의 음성명료도에 미치는 영향)

  • Kim, Seock-Hyun;Kim, Hee-Dong;Heo, Wook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.9
    • /
    • pp.888-894
    • /
    • 2007
  • The speech sound is detected by the vibration measurement of the window glass. In this study, we investigate the effect of the disturbing waves by background noise and window shaker excitation on the speech intelligibility of the detected sound. Based upon Modulation Transfer Function(MTF), speech intelligibility of the sound is objectively estimated by Speech Transmission Index(STI) As the level of the disturbing wave varies, variation of the speech intelligibility is examined. Experimental result reveals how STI is influenced by the level and frequency characteristics of the disturbing wave. By using a customized window shaker for disturbing sound, we evaluate the efficiency and the frequency characteristics of the anti-eavesdropping system. The purpose of the study is to provide useful information to prevent the eavesdropping through the window glass.

The Acoustic Character of Classroom as Using Microphone (마이크 사용시 강의실내의 음향특성)

  • 이채봉;강대기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.786-790
    • /
    • 2003
  • The purpose of this research is to observe that the acoustic characters of classroom have some difference by several conditions. TSP has used to measure impulse response and such physical indexes as RT(Reverberation Time), D$\sub$50/, and STI(Speech-Transmission-Index) are computed by it. we investigate difference under some conditions such as when students were present at each classroom and when was not so, and when professor used a microphone and unused it. In this study, we found that reverberation time when people take a seat is lower than was not so. we wish to help one who work for construction industry, as they build a kind of classroom

  • PDF

Development of a Drought Detection Indicator using MODIS Thermal Infrared Data

  • Park, Sun-Yurp
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • Based on surface energy balance climatology, surface temperatures should respond to drying conditions well before plant response. To test this hypothesis, land surface temperatures (LST) derived from MODIS data were analyzed to determine how the data were correlated with climatic water balance variables and NDVI anomalies during a growing season in Western and Central Kansas. Daily MODIS data were integrated into weekly composites so that each composite data set included the maximum temperature recorded at each pixel during each composite period. Time-integrated, or cumulative values of the LST deviation standardized with mean air temperatures had significantly high correlation coefficients with SM, AE/PE, and MD/PE, ranging from 0.65 to 0.89. The Standardized Thermal Index (STI) is proposed in this study to accomplish the objective. The STI, based on surface temperatures standardized with observed mean air temperatures, had significant temporal relationships with the hydroclimatological factors. STI classes in all the composite periods also had a strong correlation with NDVI declines during a drought episode. Results showed that, based on LST, air temperature observations, and water budget analysis, NDVI declines below normal could be predicted as early as 8 weeks in advance in this study area.

Characteristics of Acoustic Indicators Evaluating Speech Intelligibility in Korean Elementary School Classrooms (초등학교 일반교실의 음향성능 실태측정 및 평가지표 특성 고찰)

  • Lee, Seong-Bok;Kim, Myung-Jun;Yang, Hong-Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.7
    • /
    • pp.462-469
    • /
    • 2015
  • This study was carried out to examine characteristics of various acoustic indicators evaluating speech intelligibility such as reverberation time(T30), D50, C50 and speech transmission index(STI) in Korean elementary school classrooms. Results showed that mean T30 at middle frequencies(500 Hz to 2000 Hz) measured in 9 classrooms was about 0.75 s, which exceeds a regulation specified on American National Standards(ANSI); 0.60 s. Mean D50, C50 and STI were 60 % to 66 %, +2 dB to +3 dB, and 0.65, respectively. The maximum difference in D50 and C50 according to different receiver points in a classroom was 13 % and 2.5 dB, while the maximum difference in T30 was 0.03 s. Whereas STI measured in classrooms has relatively low correlation with other indicators, correlation between D50 and C50 was high, R2=.9964. In addition, T30 and C50 were fitted well as logarithmic regression curve with R2=.9610. It was +3.73 dB in C50 and 68 % in D50 which are the value corresponding to 0.60 s in T30 on this curve.

Cardiac systolic time intervals and heather index measured by impedance cardiography during postural changes (체위변화시 심장의 수축기 시간간격 및 Heather Index의 변화)

  • 고성경;김창규;김덕원
    • Journal of the Ergonomics Society of Korea
    • /
    • v.11 no.1
    • /
    • pp.67-79
    • /
    • 1992
  • Cardiac systolic time intervals (STLs) and Heather index (HI) were used to access changes in left ventricular function of six male subjects exposed to postural changes,$0^{\circ}C$, ${\pm}2^{\circ}C$, ${\pm}45^{\circ}C$, ${\pm}90^{\circ}C$, Significant prolongation of the pre-ejection period (PEP) and PEP/ LVET ratio, shortening of the left ventricular ejection time (LVET), STI, HI and $1/PEP^{2}$were observed during exposure to both $+45^{\circ}C $ and $+90^{\circ}C $But the values measured during $-45^{\circ}C $ and$-90^{\circ}C $ were reversed. Changes in fluid shift, filling volume, preload, after load and sympathetic activities may account for the observed findings. Early response of cardiac foctions was recorded using impedance cardiography. This method is very simple but accurate. Thus it will be useful in this aerospace and work physiology. In conclusion, STIs appear to provide reliable noninvasive method for examining changes of cardiac function during exposure to postural changes.

  • PDF

Comparison of Acoustic Performance Depending on the Location of Sound Absorptive and Diffuser in Small Auditoriums Using 1/10 Scale Models (1/10 축소모형을 이용한 소공연장의 흡음재와 확산체의 적용위치에 따른 음향성능 비교)

  • Kim, Tae-Hee;Park, Chan-Jae;Park, Ji-Hoon;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.2
    • /
    • pp.146-156
    • /
    • 2015
  • This study investigated how the location of sound absorptive materials and sound diffusers affects the acoustic performance of small auditoriums. It was conducted for a standard model established with the averaged dimension of 36 auditoriums which had opened since 2000 in Daehak-ro, Seoul. In this study, the installation area of finishing materials was calculated upon a back wall which had the smallest installation effective area of finishing materials. To analyze the changes of acoustic performance according to installation location of finishing materials, experiments were carried out using the 1/10 down scale models for 8 cases which were made by classifying the installation location of ceiling and side wall into the front, middle and rear part.The used acoustic parameters were reverberation time (RT), early decay time (EDT), clarity (C80), definition (D50) and speech transmission index (STI). In result, the index related to the amount of reverberant sound (RT, EDT) showed the great changes when evaluating it through just noticeable difference (JND), but the one related to clarity (C80, D50, STI) hardly indicated the changes. In case to obtain short reverberation time, it was most effective to control reverberation time through the side walls when installing sound absorptive and diffusive materials, and side wall front was the location which could get the shortest reverberation time.

Comparison of OECD Nations through a Comprehensive Evaluation Index for Low-Carbon Green Growth

  • Yoo, Eui Sun;Park, Sung Hyun;Lee, Min Hyung
    • STI Policy Review
    • /
    • v.1 no.2
    • /
    • pp.51-68
    • /
    • 2010
  • This paper compares OECD nations by developing a comprehensive evaluation index that examines the efforts and achievements of countries toward Low-Carbon Green Growth. The input-process-output of a Low-Carbon Society system is in dynamic competition with that of a High-Carbon Society system. The model used in this study of the comprehensive evaluation index for Low-Carbon Green Growth was comprised of Large indices such as Input, Process, and Output. The Input and Output consisted of 'Social-economic' and 'Physical-ecological' Middle indices while the Process was made up of 'Stimulation mechanisms' and 'Participation of stakeholders and Knowledge flow' Middle indices. In order to calculate the comprehensive evaluation index, our model gave a weight to each indicator/index and applied a weighted arithmetic mean. Korea ranked $15^{th}$ out of 30 OECD nations in the comprehensive evaluation that analyzed Input ($14^{th}$), Process ($18^{th}$), and Output ($17^{th}$). The top five nations were Switzerland, Sweden, Denmark, Germany, and France; while Japan was $8^{th}$ and the USA $26^{th}$.

Audio Signal Processing and System Design for improved intelligibility in Conference Room (회의실의 명료성(STI) 향상을 위한 오디오신호 처리 및 시스템 설계)

  • Kang, Cheolyong;Lee, Seokjoo;Jo, Kwangyeon;Lee, Seonhee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.225-232
    • /
    • 2017
  • Recently, the development of digital transmission technology of audio signals and the introduction of audio network equipment using digital transmission technology have been made. As a result, audio network technology and equipment are actively applied to the design and construction of audio systems. The meeting room is a place where a large number of participants exchange opinions and communicate with each other. In addition to using an electric acoustic device such as a microphone and a speaker, it improves the intelligibility of the conference room through an example using an audio network.

The Application of 1-Dimensional Diffusers in Classroom Acoustics (1차 단순 확산체를 적용한 교실음향설계)

  • Choi, Young-Ji
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.5
    • /
    • pp.3-11
    • /
    • 2011
  • In this study, the effect of treating 1-dimensional diffusers on the classroom acoustics was investigated to determine if the diffuser are beneficial for performing the preferred acoustical conditions for speech. A 1/10 scale model of a classroom was used to measure the acoustical parameters, T30, $C_{50}$, STI and SNR in that room. The room acoustical conditions were varied by treating diffusers either on the front or side walls of the classroom. When the diffusers were treated on the side walls around the student's areas, a shorter reverberation time at low frequencies was obtained and resulted in performing uniform reverberation times across the frequency bands. The $C_{50}$ values at mid- and high-frequencies were increased by treating the diffusers either on front or side wall surfaces. The highest STI and SNR values were obtained when the diffuser was treated on the front wall around the teacher's areas. It is found that diffusers are beneficial to increase the intelligibility of speech for the rear seats of the rooms.

  • PDF

Comparison of Sound Pressure Level and Speech Intelligibility of Emergency Broadcasting System at T-junction Corridor Space (T자형 복도 공간의 비상 방송용 확성기 배치별 음압 레벨과 음성 명료도 비교)

  • Jeong, Jeong-Ho;Lee, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.105-112
    • /
    • 2019
  • In this study, an architectural acoustics simulation was conducted to examine the clear and uniform transmission of emergency broadcasting sound in a T junction corridor space. The sound absorption performance of the corridor space and the location and spacing of the loudspeaker for emergency broadcasting were varied. The distribution of the sound pressure level and the distribution of sound transmission indices (STI, RASTI) were compared. The simulation showed that the loudspeaker for emergency broadcasting should be installed approximately 10 m from the center of the T junction corridor connection for clear voice transmission. Narrowing the 25 m installation interval of the NFSC shows that an even clearer and sufficient volume of emergency broadcast sound can be delivered evenly.