• Title/Summary/Keyword: SPOT 4

Search Result 1,625, Processing Time 0.034 seconds

Undescribed Fungal Leaf Spot Disease of Pepper Caused by Cercospora capsici in Korea (고추의 미기록병(未記錄病)인 Cercospora capsici에 의(依)한 고추 반점병(斑點病))

  • Sung, Jae-Mo;Cho, Eui-Kyoo;Cho, Dong-Jin;Kang, Soo-Woong
    • The Korean Journal of Mycology
    • /
    • v.12 no.2
    • /
    • pp.75-77
    • /
    • 1984
  • An undescribed Cercospora leaf spot of pepper grown in a greenhouse was observed at Jinju area in 1983. The symptom of this disease showed frog eyes spot on lower leaves of pepper. Leaves and petiole of pepper plant inoculated with spore suspension of this pathogen app­eared leaf spot after 2 weeks and exhibited cicular, brown frog eyes spot. This fungus was grown slowly on PDA and produce condia on infected leaves. The occurrence of this disease was responsi­ble for factors with high temperature and humidity conditions in the ill-ventilated greenhouse. This causal fungus was identified as Cercospora capsici Heald et. Wolf from the shape and length of the conidiophores, the length of the condia, and pathogenic behaviors.

  • PDF

Leaf Spot of Kudzu (Pueraria lobata) Caused by Alternaria tenuissima (Alternaria tenuissima에 의한 칡 점무늬병)

  • Kim, Ja-Moon;Lee, Jung-Sook;Song, Wan-Yeob;Lee, Sook-Kyung;Kim, Hyung-Moo;Seo, Byung-Soo
    • Research in Plant Disease
    • /
    • v.10 no.2
    • /
    • pp.126-129
    • /
    • 2004
  • In July of 2002, leaf spot disease was found on kudzu (Pueraria lobata) leaves in Jeonbuk province. A small leaf spot was appeared on leaves as a typical symptom and the spot was then surrounded by chlorotic halo. The lesions were expended and coalesced and the infected leaves became yellow leaf and later fall out. A causal fungal pathogen was isolated and the colony of the pathogen was light gray green to dark green on PDA. The pathogen produced mostly the single conidium but rarely long chain of 3 to 8 conidia. The conidia were dark brown in color, long ellipsoid or oval and 20-60 ${\times}$ 10-25 ${\mu}{\textrm}{m}$ in size. Their septa were 4-8 transverse and 1-2 longitudinal or oblique. The pathogen was, therefore, identified as Alternaria tenuissima based on cultural and morphological characteristics. This is the first report on the leaf spot of kudzu caused by A. tenuissima in Korea.

Validation and selection of GCPs obtained from ERS SAR and the SRTM DEM: Application to SPOT DEM Construction

  • Jung, Hyung-Sup;Hong, Sang-Hoon;Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.5
    • /
    • pp.483-496
    • /
    • 2008
  • Qualified ground control points (GCPs) are required to construct a digital elevation model (DEM) from a pushbroom stereo pair. An inverse geolocation algorithm for extracting GCPs from ERS SAR data and the SRTM DEM was recently developed. However, not all GCPs established by this method are accurate enough for direct application to the geometric correction of pushbroom images such as SPOT, IRS, etc, and thus a method for selecting and removing inaccurate points from the sets of GCPs is needed. In this study, we propose a method for evaluating GCP accuracy and winnowing sets of GCPs through orientation modeling of pushbroom image and validate performance of this method using SPOT stereo pair of Daejon City. It has been found that the statistical distribution of GCP positional errors is approximately Gaussian without bias, and that the residual errors estimated by orientation modeling have a linear relationship with the positional errors. Inaccurate GCPs have large positional errors and can be iteratively eliminated by thresholding the residual errors. Forty-one GCPs were initially extracted for the test, with mean the positional error values of 25.6m, 2.5m and -6.1m in the X-, Y- and Z-directions, respectively, and standard deviations of 62.4m, 37.6m and 15.0m. Twenty-one GCPs were eliminated by the proposed method, resulting in the standard deviations of the positional errors of the 20 final GCPs being reduced to 13.9m, 8.5m and 7.5m in the X-, Y- and Z-directions, respectively. Orientation modeling of the SPOT stereo pair was performed using the 20 GCPs, and the model was checked against 15 map-based points. The root mean square errors (RMSEs) of the model were 10.4m, 7.1m and 12.1m in X-, Y- and Z-directions, respectively. A SPOT DEM with a 20m ground resolution was successfully constructed using a automatic matching procedure.

Effective Detective Quantum Efficiency (eDQE) Evaluation for the Influence of Focal Spot Size and Magnification on the Digital Radiography System (X-선관 초점 크기와 확대도에 따른 디지털 일반촬영 시스템의 유효검출양자효율 평가)

  • Kim, Ye-Seul;Park, Hye-Suk;Park, Su-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • The magnification technique has recently become popular in bone radiography, mammography and other diagnostic examination. However, because of the finite size of X-ray focal spot, the magnification influences various imaging properties with resolution, noise and contrast. The purpose of study is to investigate the influence of magnification and focal spot size on digital imaging system using eDQE (effective detective quantum efficiency). Effective DQE is a metric reflecting overall system response including focal spot blur, magnification, scatter and grid response. The adult chest phantom employed in the Food and Drug Administration (FDA) was used to derive eDQE from eMTF (effective modulation transfer function), eNPS (effective noise power spectrum), scatter fraction and transmission fraction. According to results, spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.76, 2.21, 1.78, 1.49 and 1.26 lp/mm respectively using small focal spot. The spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.21, 1.66, 1.25, 0.93 and 0.73 lp/mm respectively using large focal spot. The eMTFs and eDQEs decreases with increasing magnification factor. Although there are no significant differences with focal spot size on eDQE (0), the eDQEs drops more sharply with large focal spot than small focal spot. The magnification imaging can enlarge the small size lesion and improve the contrast due to decrease of effective noise and scatter with air-gap effect. The enlargement of the image size can be helpful for visual detection of small image. However, focal spot blurring caused by finite size of focal spot shows more significant impact on spatial resolution than the improvement of other metrics resulted by magnification effect. Based on these results, appropriate magnification factor and focal spot size should be established to perform magnification imaging with digital radiography system.

Acoustic Emission Monitoring during Laser Spot Welding of Stainless Steel Sheets (스테인레스 박강판의 레이저 점 용접 시 음향방출 실시간 모니터링)

  • Lee Seoung Hwan;Choi Jung Uk;Choi Jang Eun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.4
    • /
    • pp.60-67
    • /
    • 2005
  • Compared with conventional welding, laser spot welding offers a unique combination of high speed, precision and low heat distortion. This combination of advantages is attractive for manufacturing industries including automotive and electronics companies. In this paper, a real time monitoring scheme fur a pulsed Nd:YAG laser spot welding was suggested. Acoustic emission (AE) signals were collected during welding and analyzed for given process conditions such as laser power and pulse duration. A back propagation artificial neural network, with AE frequency content inputs, was used to predict the weldability of stainless steel sheets.

Loudspeaker Driving Algorithm for Optimal Sweet Spot (최적 Sweet Spot 제공을 위한 스피커 구동 알고리즘)

  • Boo, Jeong-Yong;Choi, Su-Jin;Kim, Ki-Jun;Park, Hochong
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2014.06a
    • /
    • pp.46-49
    • /
    • 2014
  • 본 논문에서는 4개의 스피커를 이용한 음향 재생 환경에서 청취자의 위치에 따라 최적의 sweet spot을 제공하도록 스피커를 구동하는 방법을 제안한다. 먼저 청취자 위치에 대하여 대칭 구조를 가지는 스피커 쌍(pair) 후보들을 선택한다. 다음, ringing 현상을 감소시키기 위하여 앞에서 선택한 스피커 쌍 후보 중에서 스피커 간 간격이 가장 먼 스피커 쌍과 이 스피커 쌍 사이에 있는 모든 스피커를 구동 스피커로 결정한다. 마지막으로, cross-talk cancellation 행렬의 크기를 제한하여 ringing 현상을 감소시킨다. 모의실험을 통해, 청취자 위치가 변할 때 제안하는 스피커 구동 방법을 사용하여 sweet spot 면적이 일정한 수준으로 유지되어 기존 방법에 비하여 성능이 향상된 것을 확인하였다.

  • PDF

The Analysis of Welding Deformation in Arc-spot Welded Structure (II) - Displacement Monitoring and Deformation Analysis - (아크 점용접 구조물의 정밀 용접 열변형 해석에 관한 연구 (II) - 변위 모니터링 및 변형 모델 정립 -)

  • 장경복;조상명
    • Journal of Welding and Joining
    • /
    • v.21 no.4
    • /
    • pp.80-86
    • /
    • 2003
  • Arc-spot welding is generally used in joining of precise parts such as case and core in electric compressor. It is important to control joining deformation in electric compressor because clearance control of micrometer order is needed for excellent airtightness and anti-nose. The countermeasures for this deformation in field have mainly been dependent on rule of try and error by operator's experience because of productivities. For control this deformation problem without influence on productivities, development of exact simulation model should be needed. In this study, on the basis of previous study, the analysis model io predict deformation of precise order in arc-spot welded structure with non-uniform stiffness is brought up through feedback and tuning between monitoring data and analysis results. For this, deformation monitoring system was built and boundary condition considering mechanical melting temperature was applied.

Microstructure and Synthesis of Ag Spot-coated Cu Nanopowders by Hydrothermal-attachment Method using Ag Colloid (수열흡착법을 이용한 은 점코팅된 구리 나노분말의 합성과 미세조직)

  • Kim, Hyeong-Chul;Han, Jae-Kil
    • Journal of Powder Materials
    • /
    • v.18 no.6
    • /
    • pp.546-551
    • /
    • 2011
  • Ag spot-coated Cu nanopowders were synthesized by a hydrothermal-attachment method (HA) using oleic acid capped Ag hydrosol. Cu nano powders were synthesized by pulsed wire exploding method using 0.4 mm in diameter of Cu wire (purity 99.9%). Synthesized Cu nano powders are seen with comparatively spherical shape having range in 50 nm to 150 nm in diameter. The oleic acid capped Ag hydrosol was synthesized by the precipitation-redispersion method. Oleic acid capped Ag nano particles showed the narrow size distribution and their particle size were less than 20 nm in diameter. In the case of nano Ag-spot coated Cu powders, nanosized Ag particles were adhered in the copper surface by HAA method. The components of C, O and Ag were distributed on the surface of copper powder.

Occurrence of Tan-brown Leaf Spot Caused by Pilidium concavum on Fragaria ananassa in Korea

  • Park, Mi-Jeong;Back, Chang-Gi;Park, Jong-Han;Han, Kyung-Sook
    • The Korean Journal of Mycology
    • /
    • v.45 no.4
    • /
    • pp.377-380
    • /
    • 2017
  • In 2015, a new leaf spot disease was observed on strawberry seedlings in Wanju, Korea. Tanned brown spots appeared on the leaves of the infected plants, and often coalesced to form larger necrotic areas, resulting in the death of foliage. An isolate was obtained in pure culture. On the basis of morphological characteristics and molecular analysis of internal transcribed spacer rDNA sequence, the causal agent was identified as Pilidium concavum. Pathogenicity tests revealed the isolate was pathogenic to the leaves and fruits of strawberry. To the best of our knowledge, this is the first report of P. concavum causing tan-brown leaf spot on strawberry in Korea.

A Dynamic Bandwidth Allocation Scheme for a Multi-spot-beam Satellite System

  • Park, Unhee;Kim, Hee Wook;Oh, Dae Sub;Ku, Bon-Jun
    • ETRI Journal
    • /
    • v.34 no.4
    • /
    • pp.613-616
    • /
    • 2012
  • A multi-spot-beam satellite is an attractive technique for future satellite communications since it can support high data rates by projecting high power density to each spot beam and can reuse a frequency in different cells to increase the total system capacity. In this letter, we propose a resource management technique adjusting the bandwidth of each beam to minimize the difference between the traffic demand and allocated capacity. This represents a reasonable solution for dynamic bandwidth allocation, considering a trade-off between the maximum total capacity and fairness among the spot beams with different traffic demands.