• Title/Summary/Keyword: SLICE

Search Result 981, Processing Time 0.034 seconds

Factor Analysis of Decreased Score on Coronary Artery Calcium Score (관상동맥 석회화점수 감소 요인 분석)

  • Shim, Jae-Goo;Kim, Yon-Min;Kim, Jin-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.285-290
    • /
    • 2016
  • The purpose of our study was to retrospectively evaluate the cause of a decreased calcium score of follow-up studies on coronary artery calcium scores (CACs) computed tomography (CT). The subjects were healthy 100 people(85 males $60.6{\pm}6.9$ years, 15 females $67.2{\pm}7.3$ years). The subjects decreased CACs were divided into 4 subgroups depending on Agatston classification, minimal (1-10), mild (11-100), moderate (101-400), severe (400<). As a result of decreased CACs were scan location disagreement 51%, motion artifact 26%, equipment changes 14%, operator mistakes 5%, input miss 2%, image loss 1%, arrhythmia 1%. In the mild group, the most common decreased CACs were 49 people. In the minimal group, the most significant variation reduction has occurred to 6 people. Scan location disagreement was considered a partial volume effects due to the scan starting position. It showed less than 100 CACs a high variation (19.7%) in more than 100 CACs, a lower variation (2.2%), these could be seen that the variation range is different that can be tolerated according to the calcification score. Motion artifact factor was found in 26%, which is so closely related to the preceding tests that affect the higher heart rate like this pulmonary function test, exercise stress test.

Serial $^{99m}Tc$-HMPAO Brain SPECT for Assessing Perfusion Improvement after EDAS in Moyamoya Patients (모야모야병에서 EDAS 수술효과의 평가를 위한 수술전후 $^{99m}Tc$-HMPAO SPECT의 유용성)

  • Lee, Kyung-Han;Lee, Sang-Hyung;Yeo, Jeong-Seok;Kwark, Chul-Eun;Chung, June-Key;Lee, Myoung-Chul;Cho, Byoung-Kyu;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.22-30
    • /
    • 1994
  • Encephalo-duro-arterio-synangiosis (EDAS) is a relatively new surgical procedure for treatment of childhood moyamoya disease. We assessed regional cerebral perfusion in moyamoya patients before (1.3 mo) and after (6.8 mo) EDAS with $^{99m}Tc$-HMPAO brain SPECT. A total of 21 EDAS operations in 17 moyamoya patients was included. Preoperative CT or MRI showed cerebral infarction in 14 patients and carotid angiography showed Suzuki grade I to V stenosis in 6%, 9%, 62%, 12% and 12% of the hemispheres respectively. Preoperative SPECT showed regional hypoperfusion in all patients, bilateral frontal and temporal lobes being the most frequently involved site. $4{\times}4$ pixel sized ROIs were applied on the frontotemporal cortex in 3 slice averaged transverse tomographic images. An index of regional perfusion was measured as: PI (%)=average F-T activity/average cerebellar activity${\times}100$ Pre-EDAS ipsilateral PI ranged from 23.7 to 98.4% (mean: $74.3{\pm}17%$) and increased significantly after operation ($81.4{\pm}17%$, p<0.001). Individual post-EDAS PI improved in 15/21 cases, showed no significant change in 5 and was slightly aggravated in 1. The amount of clinical improvement (${\Delta}CI$) was graded with a scale of 0 to 4 based on frequency and severity of TIA attacks. When patients were grouped according to pre-EDAS PI, group II (PI 70-89) showed a significantly higher ${\Delta}CI$ (3.3) compared to group I (PI< 70, 1.57) or group III (PI >90, 0.5) (P< 0.001). The amount of perfusion improvement (${\Delta}PI$) showed significant correlation with ${\Delta}CI$ (r=0.42, p=0.04). ${\Delta}PI$ did not, however, correlate with the amount of neovascularization assessed angiographically in 8 patients. Serial HMPAO SPECT is an useful noninvasive study for assessing perfusion improvement after EDAS in childhood moyamoya patients.

  • PDF

Optimum Design of Jaenggi(Korean plow) Bottoms to Improve the Tillage Performance(I) -The Geometrical Characteristics of the Jaenggi Bottoms- (경운성능(耕耘性能) 향상(向上)을 위한 쟁기 이체(犂體)의 적정(適正) 설계(設計)에 관(關)한 연구(硏究) -쟁기 이체곡면(犂體曲面)의 기하학적(幾何學的) 특성(特性)-)

  • Chung, C.J.;Han, M.B.
    • Journal of Biosystems Engineering
    • /
    • v.12 no.3
    • /
    • pp.30-41
    • /
    • 1987
  • The geometrical shape of a plow bottom may be the most important factor affecting the performance of a plow for a given soil and operating conditions. There are various designs of the Jaenggi (Korean plow) available commercially, which may be different from each other and from the plow (Western plow) in respect to the shape and performance. This study was intended to investigate the geometrical characteristics of Jaenggi. The coordinate digitizer equipped with 3 potentiometers was designed and manufactured for measurement of the shape of curved plane of moldboard and share. The digitizer was connected to a microcomputer having the data acquisition system. This device was used to analyze the plow bottoms of 5 differently-made Jaenggis and one cylindrical plow. The results of the study are summarized as follows: 1. It was possible to measure easily and quickly the curved plane of plow bottom and to plot the view on three major plans using the coordinate digitizer electrically connected to a microcomputer system. 2. The shape of five Jaenggi bottoms analyzed could be characterized by the cutting angle having the range of $33-42^{\circ}$, the maximum share-lift angle of $41-50^{\circ}$, and the setting angle of moldboard wing of $46-70^{\circ}$. The most critical difference of the shape factors between the Jaenggi and the plow was found in the maximum share-lift angle, the former was more than twice as much as the latter. 3. The analysis of the shape of Jaenggi bottoms showed that the share projections on 3 major plans had a varied triangle, which was quite different from that of plow bottom. Especially, it was analyzed that the shape of furrow slice for the Jaenggi had a skewed rectangle, leaving a considerable height of the ridge at the furrow bottom. 4. The dihedral angle was similar range of $30-85^{\circ}$ for the all bodies investigated, but the directional angle was somewhat different from each other. The difference in directional angle was $5^{\circ}$ for the plow, $20^{\circ}$ for the Jaenggi A and $30^{\circ}$ for the Jaenggi B. 5. Area of the spherical representation region was 0.0328 for the plow, 0.1194 for the Jaenggi A and 0.1716 for the Jaenggi B. This may indicate that the plow came close to a working surface and the Jaenggi A and the Jaenggi B departed from a working surface to a somewhat greater extent.

  • PDF

Dehydration of Sliced Ginger Using Maltodextrin and Comparison with Hot-air Dried and Freeze-dried Ginger (Maltodextrin을 처리한 생강 절편의 탈수, 건조 및 열풍 건조와 동결건조된 생강과의 비교)

  • Kim, Min-Hee;Kim, Min-Ki;Yu, Myung-Shik;Song, Young-Bok;Seo, Won-Joon;Song, Kyung-Bin
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.146-150
    • /
    • 2009
  • Sliced ginger samples were dried using 30, 50, and 80% maltodextrin, respectively, as a dehydrating agent. The moisture content of the maltodextrin-treated ginger decreased with increasing concentrations of maltodextrin. The dehydrated ginger was compared with hot air-dried and freeze-dried ginger samples in terms of rehydration ratio, gingerol content, color, and sensory characteristics. The rehydration ratio of the maltodextrin-treated ginger was superior to those of the hot-air dried or freeze-dried ginger. In addition, the maltodextrin-treated ginger had the highest content of 6-gingerol among the samples. Color as well as sensory scores for odor, texture, appearance, and overall acceptance were greater for the maltodextrin-treated ginger compared to the hot-air dried or freeze-dried ginger. These results indicate that drying ginger with maltodextrin is very efficient because good rehydration capacity is retained and minimal cell destruction can be achieved.

Radiation Dose and Image Quality of Low-dose Protocol in Chest CT: Comparison of Standard-dose Protocol (흉부 CT촬영에서 저선량 프로토콜의 선량과 화질: 표준선량 프로토콜과 비교)

  • Lee, Won-Jeong;Ahn, Bong-Seon;Park, Young-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.84-89
    • /
    • 2012
  • The purpose of this study was to compare radiation dose and image quality between low-dose (LDP) and standard-dose protocol (SDP). LDP (120 kVp, 30 mAs, 2-mm thickness) and SDP (120 kVp, 180 mAs, 1.2-mm thickness) images obtained from 61 subjects were retrospectively evaluated at level of carina bifurcation, using multi-detector CT (Brilliance 16, Philips Medical Systems). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated at ascending aorta and infraspinatus muscle, from CT number and back-ground noise. Radiation dose from two protocols measured at 5-point using acrylic-phantom, and CT number and noise measured at 4-point using water-phantom. All statistical analysis were performed using SPSS 19.0 program. LDP images showed significantly more noise and a significantly lower SNR and CNR than did SDP images at ascending aorta and infraspinatus muscle. Noise, SNR and CNR were significantly correlated with body mass index (p<0.001). Radiation dose, SNR and CNR from phantom were significant differences between two protocols. LDP showed a significant reduction of radiation dose with a significant change in SNR and CNR compared with SDP. Therefore, exposure dose on LDP in clinical applications needs resetting highly more considering image quality.

Assessment of Aging Effects on Computed Tomographic Glomerular Filtration Rate in Dogs (개에서 연령에 따른 동적 컴퓨터단층촬영을 이용한 사구체여과율의 평가)

  • Chang, Jin-Hwa;Kim, Hwan-Cheol;Choi, Ji-Young;Choi, Ho-Jung;Lee, Hee-Chun;Chang, Dong-Woo;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.130-133
    • /
    • 2012
  • The purpose of this study is to assess the relationship between glomerular filtration rate (GFR) and age by using dynamic computed tomography (CT) and Patlak plot analysis in dogs. Fifteen dogs were used in this study. CT-GFR study was performed under general anesthesia using propofol and isoflurane. 1 ml/kg dosage of 300 mgI/ml iohexol was administered at a rate of 3 ml/s during GFR measurement. CT-GFR was determined with a single-slice dynamic acquisition and Patlak plot analysis. The individual and global GFR values were calculated to plasma clearance per body weight (ml/min/kg). Bodyweight ($mean{\pm}SD$) ranged from 2.0 to 5.7 kg ($3.31{\pm}1.13$ kg). Age ranged from 3 years to 13 years old ($7.14{\pm}3.30$). $Mean{\pm}SD$ creatinine ($0.53{\pm}0.34 $mg/dl), phosphorus ($4.1{\pm}1.2$ mg/dL), and albumin ($3.3{\pm}0.3$ mg/dL) concentrations and urine protein-to-creatinine ratios (all ratios were < 0.5) were within reference ranges. Abdominal ultrasonography revealed small-sized renal calculi, mineralization, or renal cyst at eight dogs. The global CT-GFR ranges shown in this study was 2.57 to 6.60 ml/min/kg. In this study, there was no trend toward weight-adjusted CT-GFR with increasing age. We found no relationships between age-related kidney dysfunction in fifteen dogs. Small-sized renal calculi or cysts did not affect renal function in this study. However, it is thought that a large sample size may have been required to document an age effect.

Interleukin-8-like chemotactic factor from feline peripheral blood mononuclear cells cultured with egg white derivatives (계난백유래물질로 배양한 고양이 말초혈액 단핵구세포에서 분비되는 interleukin- 8 양(樣) 유주성인자)

  • Lee, Jae-kwon;Yang, Mhan-pyo
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.2
    • /
    • pp.393-401
    • /
    • 2000
  • The feline chemotactic factor(s) for polymorphonuclear cells (PMN) in culture supernatant from mononuclear cells (MNC) treated with egg white derivatives (EWD) were examined. Culture supernatant from MNC treated with EWD and human recombinant (hr) IL-8 remarkably enhanced chemo-taxis of feline PMN. To investigate feline chemotactic factor(s), gel electrophoresis was performed with culture supernatant from MNC treated with EWD under denaturing (18% loading gel/5% stacking gel) and nondenaturing (12.5% loading gel/5% stacking gel) condition. Hr IL-8 and culture supernatant from MNC treated with EWD yielded a distinct band in a molecular weight, 6 to 8 kDa. Eluted solution from gel slices of 6 to 8 kDa band in denaturing condition also enhanced feline PMN chemotaxis. These chemotactic activities of feline PMN induced by culture supernatant from MNC treated with EWD, hr IL-8 and eluted solution were inhibited in a dose-dependent manner by rabbit anti-feline polyclonal IgG (RAF pIgG) and monoclonal antibody (mAb) against hr IL-8. RAF pIgG also showed a binding activity with hr IL-8, suggesting that RAF pIgG against feline IL-8-like chemotactic factor(s) had cross-reactivity with human IL-8. These results suggested that feline MNC treated with EWD might release feline IL-8-like chemotactic factor(s) with a molecular weight, 6 to 8 kDa, which induces the chemotaxis of feline PMN.

  • PDF

The Kinematic Analysis of the Tennis Flat Serve Motion (테니스 플랫 서브 동작의 운동학적 분석)

  • Oh, Cheong-Hwan;Choi, Su-Nam;Nam, Taek-Gil
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.2
    • /
    • pp.97-108
    • /
    • 2006
  • C. H. OH, S. N. CHOI, T. G. NAM, The Kinematic Analysis of the Tennis Flat Serve Motion, Korean Jiurnal of Sports Biomechanics, Vol. 16, No. 2, pp. 97-108, 2006. By the comparison and the analysis of the different factors during the tennis flat serve motion such as the required time per section, the movement displacement of the racket, the velocity of the upper limbs joints, the physical center of gravity, and the angle and the angular velocity of the upper limbs joints between an ace player and a mediocre player, these following results were drawn. First, the experiment result of the total time required per section in a tennis flat serve motion showed that an ace player was faster than a mediocre player by 0.4 seconds. This result suggested that it was required to increase the speed of the racket head by a swift swing to perform an effective flat serve motion. Second, the experiment result of the movement displacement of the racket in the tennis flat serve motion showed that an ace player greatly moved toward the left side on an x-axis. But both an ace and a mediocre player were shown to be at the similar points on a y-axis at the moment of the impact of the racket. An ace player was also shown to be located at a higher position on a z-axis by 0.23m. Third, the velocity of the center of gravity of an ace player was faster in every phase than that of a mediocre player in a tennis flat serve motion. Fourth, the velocity of the upper limb joints of an ace player was faster in every phase than that of a mediocre player in a tennis flat serve motion. Fifth, the experiment result of the speed of the racket head in tennis flat serve motion showed that a mediocre player was faster than an ace player in the first phase, but the latter was faster than the former in the second, third, and the fourth phases. Sixth, at the moment of impact of a tennis flat serve, an ace player had greater flexion of the angle of the wrist joints by an 11.8 degree than a mediocre player. An ace player also had greater extension of the angle of the elbow joint and the shoulder joint respectively by a 5.2 degree and a 1.4 degree with a mediocre player. Seventh, an ace player had greater angular velocity of the upper limb joints and the hip joints than a mediocre player at the moment of the impact of tennis flat serve. Eighth, an ace player was shown to have a greater change of the forward and the backward inclination (or the anterior and posterior inclination) of the upper body

A Study on the Digital Filter Design for Radio Astronomy Using FPGA (FPGA를 이용한 전파천문용 디지털 필터 설계에 관한 기본연구)

  • Jung, Gu-Young;Roh, Duk-Gyoo;Oh, Se-Jin;Yeom, Jae-Hwan;Kang, Yong-Woo;Lee, Chang-Hoon;Chung, Hyun0Soo;Kim, Kwang-Dong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.1
    • /
    • pp.62-74
    • /
    • 2008
  • In this paper, we would like to propose the design of symmetric digital filter core in order to use in the radio astronomy. The function of FIR filter core would be designed by VHDL code required at the Data Acquisition System (DAS) of Korean VLBI Network (KVN) based on the FPGA chip of Vertex-4 SX55 model of Xilinx company. The designed digital filter has the symmetric structure to increase the effectiveness of system by sharing the digital filter coefficient. The SFFU(Symmetric FIR Filter Unit) use the parallel processing method to perform the data processing efficiently by using the constrained system clock. In this paper, therefore, for the effective design of SFFU, the Unified Synthesis software ISE Foundation and Core Generator which has excellent GUI environment were used to overall IP core synthesis and experiments. Through the synthesis results of digital filter core, we verified the resource usage is less than 40% such as Slice LUT and achieved the maximum operation frequency is more than 260MHz. We also confirmed the SFFU would be well operated without error according to the SFFU simulation result using the Modelsim 6.1a of Mentor Graphics Company. To verify the function of SFFU, we carried out the additional simulation experiments using the pseudo signal to the Matlab software. From the comparison experimental results of simulation and the designed digital FIR filter, we confirmed the FIR filter was well performed with filter's basic function. So we verified the effectiveness of the designed FIR digital filter with symmetric structure using FPGA and VHDL.

  • PDF

Fast Scene Change Detection Using Macro Block Information and Spatio-temporal Histogram (매크로 블록 정보와 시공간 히스토그램을 이용한 빠른 장면전환검출)

  • Jin, Ju-Kyong;Cho, Ju-Hee;Jeong, Jae-Hyup;Jeong, Dong-Suk
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.1
    • /
    • pp.141-148
    • /
    • 2011
  • Most of the previous works on scene change detection algorithm focus on the detection of abrupt rather than gradual changes. In general, gradual scene change detection algorithms require heavy computation. Some of those approaches don't consider the error factors such as flashlights, camera or object movements, and special effects. Many scenes change detection algorithms based on the histogram show better performances than other approaches, but they have computation load problem. In this paper, we proposed a scene change detection algorithm with fast and accurate performance using the vertical and horizontal blocked slice images and their macro block informations. We apply graph cut partitioning algorithm for clustering and partitioning of video sequence using generated spatio-temporal histogram. When making spatio-temporal histogram, we only use the central block on vertical and horizontal direction for performance improvement. To detect camera and object movement as well as various special effects accurately, we utilize the motion vector and type information of the macro block.