• 제목/요약/키워드: SAW Sensor

검색결과 111건 처리시간 0.025초

WO$_3$박막을 이용한 SAW 가스 센서 (SAW Gas Sensor using WO$_3$Thin Film)

  • 정영우;허두오;이해민;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1995년도 추계학술대회 논문집
    • /
    • pp.187-189
    • /
    • 1995
  • A Surface Acoustic Wave Gas sensor for NO, CO, H$_2$gas detection was designed fabricated, and tested. A delay line device was designed to composite a single mode SAW oscillator which enables to measure a SAW velocity. To reduce the effect of temperature and humidity, dual delay line oscillator circuit was used. And final output was measured by digital frequency counter. NO, CO, H$_2$gas were detected by WO$_3$thin film deposited on the path of the Delay Line.

  • PDF

SAW 디바이스를 이용한 냄새센서의 특성 (Characteristics of odorant sensor using SAW Device)

  • 김기영;김종민;신훈규;최웅성;권영수;장상목
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1457-1459
    • /
    • 1994
  • A surface acoustic wave(SAW) sensor for the detection of odorants has been constructed by depositing various phospholipids and fatty acids onto the surface of the SAW device. Applying the Langmuir-Blodgett technique, it was possible to deposit the optimal number of layers which was found to be between 10 and 20. Menthone, amylacetate, acetoin, and other organic gases showed different affinities to the coated lipids. An explanation is given for different odorant affinities based on the monolayer properties of phospholipids.

  • PDF

발진기의 2채배 고조파 주파수 천이를 이용한 생체신호 측정센서 (Vital Sign Sensor Based on Second Harmonic Frequency Drift of Oscillator)

  • 구기영;홍윤석;이희조;윤기호;육종관;김강욱
    • 한국전자파학회논문지
    • /
    • 제27권3호
    • /
    • pp.299-306
    • /
    • 2016
  • 본 논문에서는 공진기와 인체와의 거리에 따른 근접 전자기장 변화에 의한 공진기 임피던스의 변화를 토대로 사람의 호흡 및 심박신호를 검출할 수 있는 센서를 제안한다. 제안된 생체신호 측정센서는 패치형 공진기가 결합된 발진기, 발진주파수의 2채배 주파수만 통과시키기 위한 다이플렉서, 증폭기, SAW 필터 및 RF 검출기로 구성되어 있다. 호흡과 심박신호와 같은 인체의 주기적인 움직임은 근접 전자기장 영역 안에서 공진기의 임피던스 변화를 야기하며, 발진기의 주파수를 변화시킨다. 감도를 향상시키기 위해 발진주파수의 2채배 주파수 천이를 SAW 필터의 저지대역에 위치시킴으로써, 제안된 센서의 검출 거리를 2배로 확장시킬 수 있다. 제안된 센서의 측정결과, 최대 40 mm까지 호흡 및 심박신호가 안정적으로 측정되는 것을 확인하였다.

헥사플루오르프로펜 플라즈마박막을 이용한 표면탄성파발진기 습도센서 (surface acoustic wave oscillator hymidity sensor using hexafluoropropene plasma thin film)

  • 박남천;서은덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1992년도 춘계학술대회 논문집
    • /
    • pp.144-146
    • /
    • 1992
  • Surface acoustic wave(SAW) oscillator offers many attractive features for application to vapor sensors. The perturbation of SAW velocity by the hexafluoropropence plasma polymer thin film has been studied for relative humidity sensing. adsorption of moisture produces rapid aid changes in the properties of the film, resulting in a change in the velocity of surface acoustic waves and, hence, in the frequency of one SAW oscillator. The device used in our experiments have 55 MHZ SAW oscillator fabricated on a LiNbO substrate.

  • PDF

임피던스 정합을 통한 횡단형 Withdrawal SAW 필터의 성능개선 (Improvement of Withdraw릴 Weighted SAW Transversal Filter Performance through Impedance Matching)

  • 이영진;이승희;노용래
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2000년도 하계학술발표대회 논문집 제19권 1호
    • /
    • pp.389-392
    • /
    • 2000
  • 본 연구에서는 1, 2단자쌍 회로망의 임피던스 정합회로를 간단하고 빠르게 구할 수 있는 방안을 개발하였다. 우선 회로망의 전체 전달함수를 F 행열로 부터 계산하고, 이를 이용하여 양단의 부하저항 및 정합회로가 포함된 각각의 단자의 입출력 임피던스를 구하였으며, 이 식으로부터 정합용 소자의 정확한 값을 계산하였다. 본 연구의 타당성을 검증하기 위해 CDMA용 소자로 널리 사용되는 중간주파수 대역 withdrawal 가중형 SAW 필터에 본 연구의 결과를 적용하여 임피던스 정합 전후의 특성변화를 시뮬레이션과 실험을 통하여 동시에 확인하였다 그 결과 85.38 MHz의 중심주파수에서 비대역폭이 $1.2\%$, 삽입손실이 29dB, VSWR이 80인 필터를 본 연구방법을 이용하여 정합 한 경우, 각각 $1.8\%$, 9dB, 3으로 향상됨을 시뮬레이션과 실험을 통해 확인하였다. 본 연구결과는 SAW 디바이스의 정합에 매우 용이하게 이용될 수 있을 뿐만 아니라 일반적인 1, 2단자쌍 회로망의 임피던스 정합에도 널리 사용될 수 있다

  • PDF

무선 화학센서용으로 다결정 AlN 위에 성장된 나노결정질 ZnO 막의 특성 (Characteristics of nanocrystalline ZnO films grown on polyctystalline AlN for wireless chemical sensors)

  • 레티송;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.252-252
    • /
    • 2009
  • In this work, the nanocrystalline ZnO/polycrystalline (poly) aluminum nitride (AlN)/Si structure was fabricated for humidity sensor applications based on surface acoustic wave (SAW). In this structure, the ZnO film was used as sensing material layer. These ZnO and AlN(0002) were deposited by so-gel process and a pulse reactive magnetron sputtering, respectively. These experimental results showed that the obtained SAW velocity on AlN film was about 5128 m/s at $h/\lambda$=0.0125 (h and $\lambda$ is thickness and wavelength, respectively). For ZnO sensing layers coated on AlN, films have hexagonal wurtzite structure and nanometer particle size. The crystalline size of ZnO films annealed at 400, 500, and 600 $^{\circ}C$ is 10.2, 29.1, and 38 nm, respectively. Surface of the film exhibits spongy which can adsorb steam in the air. The best quality of the ZnO film was obtained with annealing temperature at 500 $^{\circ}Cis$. The change in frequency response (127.9~127.85 MHz) of the SAW humidity sensor based on ZnO/AlN structure was measured along the change in humidity (41~69%). The structural properties of thin films wereinvestigated by XRD and SEM.

  • PDF

SAW 태그를 이용한 재택환자 종합관리시스템 구현 (Implementaion of Home Healthcare System for a Patient using SAW Tag)

  • 송재철
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.183-188
    • /
    • 2017
  • 본 논문은 SAW태그를 이용하여 환자의 위치를 파악하고, 바이오 센서를 활용하여 재택환자의 상태를 집안의 사람들에게 쉽게 전달하며, 위급상황에 대처가능한 시스템의 개발에 관한 것이다. 일반적으로 집안에서 환자가 가장 많이 다치는 장소는 화장실이고, 개인의 프라이버시가 지켜져야 하는 점과 환자의 상태를 확인하고 위급시 대처해야 하는 부분이 첨예하게 대립하는 지점이므로, 개인의 프라이버시를 지키면서 재택환자의 상태를 모니터링가능한 방법을 고안하였고, 관련 시스템을 제안한다. 또한 SAW 태그를 이용하여 사용자의 위치도 확인가능한 위치 확인 시스템도 연동할 수 있도록 제안하였다. SAW태그는 송신기에서 오는 전파를 그대로 전송하며 자신의 고유 아이디를 전달할 수 있어 3차원 위치 측정에 유용하고, 이를 사용자의 의복에 부착할 경우 입체적인 위치를 측정할 수 있어 생체신호와 같이 정보를 전달할 경우 요양원 같이 많은 환자를 관리하는 종합적인 환자관리 시스템으로 활용이 가능한 장점이 있다. 본 연구에서는 상기의 상태 및 위치 측정 시스템을 구현하여 정상적으로 구동되는 것을 확인하였다.

Metal oxide 센서를 바탕으로한 전자코와 SAW 센서를 바탕으로한 GC를 이용한 저장 중 김의 품질 평가 (Quality Evaluation of Dried Laver (Porphyra yezoensis Ueda) Using Electronic Nose Based on Metal Oxide Sensor or GC with SAW Sensor During Storage)

  • 조연수;노봉수
    • 한국식품과학회지
    • /
    • 제34권6호
    • /
    • pp.947-953
    • /
    • 2002
  • 시중에서 판매되는 김을 구입하여 습도가 32%, 43%, 75%, 온도는 $5^{\circ}C,\;15^{\circ}C,\;30^{\circ}C$에서 각각 김을 보관 한 후 저장 기간에 따른 김의 품질변화를 metal oxide 센서로 구성된 전자코와 SAW 센서를 바탕으로한 GC(z-Nose)를 이용하여 측정하였다. PCA 분석결과, $5^{\circ}C$, 32%에서 보관한 김의 경우는 저장기간이 지나도 김의 품질변화가 거의 없었다. 이것은 온도와 습도가 모두 낮아 김의 품질변화에는 영향을 미치지 않았으며, RH 43%, RH 75%에서 보관한 김의 경우는 저장기간이 지날수록 제 1 주성분 값이 양의 값$(+0.2{\sim}0.4})$에서 음의 값$(-0.4{\sim}\;-0.2)$으로 변화하는 경향으로 나타났다. RH 43% 보다 75%의 경우가 더 뚜렷한 감소를 보였으며 높은 상대습도 조건에서는 $15^{\circ}C$$30^{\circ}C$에서 유사한 경향을 나타내었다. z-Nose로 얻은 데이터를 패턴 분석한 결과 저장 기간이 지나면서 저장 온도와 습도에 따라 변질된 향시성분의 차이를 보여주었다. 이것은 미생물 수를 측정할 때와 마찬가지의 결과$(r^2=0.87)$를 보였으며 색도와는 크게 영향이 없음을 알 수 있었다. 이것으로 보면 전자코를 이용하여 조건을 달리하여 보관한 김의 품질관리를 효과적임을 알 수 있었다.

Love파를 이용한 저점성 유체 점도 측정용 표면 탄성파 센서 개발 (Development of Surface Acoustic Wave Sensor for Viscosity Measurement of Low Viscose Liquid Using Love Wave)

  • 이상대;김기복;이대수
    • Journal of Biosystems Engineering
    • /
    • 제33권4호
    • /
    • pp.282-287
    • /
    • 2008
  • Love wave is one of the shear horizontal waves and it can propagate between two layers in liquid without energy loss. The SAW (surface acoustic wave) sensor using Love wave is very useful for real time measurement of the viscosity of liquid with high sensitivity. In this study, the 77 MHz and 155 MHz Love wave SAW sensors were fabricated and use to measure the viscosity of low viscous liquid. To generate the surface acoustic wave, the inter-digital transducers were fabricated on the quartz crystal wafer. In order to obtain the optimal thickness of the coating film (novolac photoresist) generating the Love wave on the surface of SAW device, theoretical calculation was performed. The performances of fabricated Love wave SAW sensors were tested. As test liquid, pure water and glycerol solutions having different concentrations were used. Since the determination coefficients of the regression equations for measuring the viscosity of liquid are greater than 0.98, the developed Love wave SAW sensors in this study will be very useful for precise measurement of viscosity of liquid.

$NO_2$ 가스 감지를 위한 표면탄성파 센서의 제작 및 특성 (Fabrication and Characteristics of Surface-Acoustic-Wave Sensors for Detecting $NO_2$ GaS)

  • 최동한
    • 센서학회지
    • /
    • 제8권2호
    • /
    • pp.108-114
    • /
    • 1999
  • 표면 탄성파 가스센서는 소자의 크기가 작고, 값이 싸며, 가스에 대한 감도가 매우 높고 소자의 신뢰도가 높은 장점을 갖고 있다. 본 연구에서는, $LiTaO_3$ 단결정 압전기판 위에 이중지연선을 갖는 표면 탄성파 $NO_2$ 가스센서를 설계 및 제작하였다. 제조된 IDT의 커패시턴스는 79.3MHz의 주파수에서 326.34pF였다. 임피던스 매칭이 된 IDT의 반사손실은 79.3MHz의 주파수에서 최대인 -16.74dB로 나타났다. SAW 발진기를 성하여 고주파증폭기의 이득을 적절히 조정함으로써 안정된 발진이 이루어짐을 확인하였다. SAW 발진기의 $NO_2$ 가스에 대한 발진주파수의 변이는 28Hz/ppm으로 나타났다.

  • PDF