• Title/Summary/Keyword: S-2 glass

Search Result 1,672, Processing Time 0.036 seconds

Studies on the Reinforced Effect of Rubber Elastomer by means of Milled Glass Fiber Treated with Silane Coupling Agents (Silane Coupling제(劑) 처리(處理) Glass Fiber에 의(依)한 탄성체(彈性體)의 보강효과(補强效果)에 관(關)한 연구(硏究))

  • Lee, Sang-Hyun;Yoo, Chong-Sun;Paik, Nam-Chul
    • Elastomers and Composites
    • /
    • v.22 no.3
    • /
    • pp.204-212
    • /
    • 1987
  • The purpose of this study is to investigate the reinforced effect between MGF treated silane coupling agents and rubber matrix under the configuration chemical bonds, also the effect of triazine thiol compounds. For this study, vulcanizates were prepared with fifteen different compounding formulas. Their vulcanization characteristics, physical properties were examined by means of the ODR(Oscillating Dist Rheometer), the tensile tester, the benzene swelling test. The results of this study obtained are as follows: 1. In the ODR test, the MA vulcanizate was the fastest one in terms of having reached to optimum cure time($t_{90}$) and, with the same formula, when MGF vulcanizates, the shortest optimum cure times has appeared. 2. The SA, SC vulcanizates were the best the other in the physical properties such as 100%modulus, 200%modulus, 300%modulus, tensile strength. The SB vulcanizate, with higher density of crosslinking than other vulcanizates. The vulcanizates, which were filled with MGF treated with silane coupling agents we were the higher density of crosslinking than vulcanizates filled with MGF only. 3. In aging properties, the silica vulcanizates appeared to be better than the other vulcanizates. The aging Properties of treated MGF vulcanizates were similar to the silica vulcanizates. The(CR+APS+silica) and(CR+APS+MCF) were easily crosslinked by exposure to the air, and the physical properties have been improved.

  • PDF

Comparison on the Dosimetry of TLD and PLD by Dose Area Product (DAP(Dose Area Product)를 이용한 TLD와 PLD의 선량 측정 비교)

  • Choi, Jae-Ho;Kang, Gu-Jun;Chang, Seo-Goo
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.3
    • /
    • pp.244-250
    • /
    • 2012
  • The results of analyzing the difference between performances of individual dosimeters on this research subjecting the PLD and TLD, which are the official personal dosimeters, through dosimetry are as follows. After scanning the integral dose using an automatic scanner, the values of two devices that went through dose adjustment process had a statistical difference in TLD and PLD measurements under each filming conditions which were 70kVp, 200mA, 0.012sec and 42kVp, 100mA, and 0.012sec (p<0.001 and p<0.001 respectively). As for the difference of measurement value between DAP and the two particles under 70kVp, 200mA, 0.012sec filming condition, TLD had a value lower than DAP average value by $44.2mGy{\cdot}cm^2$ and PLD had a value of $246.8mGy{\cdot}cm^2$ which was lower than DAP average value by $15.5mGy{\cdot}cm^2$, while under 42kVp, 100mA, 0.012sec filming condition, TLD had a value lower than DAP average value by $17.9mGy{\cdot}cm^2$ and PLD had a value of $82.6mGy{\cdot}cm^2$ which was lower than DAP average value by 7.6$mGy{\cdot}cm^2$. Also, compared to PLD, each of 10 devices measured dose value in TLD had a larger deviation between the particles, and for a reproducibility test which repeatedly measured one particle, PLD had ${\pm}1%$ which was lower than TLD's ${\pm}2%$. As such, PLD had a superior performance result in dose measurement capacities aspect compared to TLD, and therefore we could verify that PLD is more appropriate and advantageous in managing radiation-related task performing worker's personal radiation exposure management in the diagnostic radiation field.

Effects of specimens dimension on the flexural properties and testing reliability of dental composite resin (치과용 복합레진의 굽힘 특성과 시험 신뢰도에 미치는 시편 크기의 영향)

  • Im, Yong-Woon;Hwang, Seong-sig;Kim, Sa-hak;Lee, Hae-Hyoung
    • Korean Journal of Dental Materials
    • /
    • v.44 no.3
    • /
    • pp.273-280
    • /
    • 2017
  • The aim of the present study was to investigate the effects of specimen dimension on the flexural properties and testing reliability of dental composite resin. The composite resin was prepared experimentally by mixing a resin matrix with silanated micrometer glass filler at 50 vol%. Flexural specimens with various dimension in specimen's width were fabricated by light curing using a split metal mold; $25{\times}2{\times}2mm$, $25{\times}2{\times}4mm$, $25{\times}2{\times}6mm$ in length ${\times}$ height ${\times}$ width. The flexural strength and modulus were determined according to ISO 4049 test protocol at a span length of 20 mm (normal-flexural strength; NFS). Another flexural test was conducted using mini-sized specimens ($12{\times}2{\times}2mm$, $12{\times}2{\times}4mm$, $12{\times}2{\times}6mm$) from the broken specimens at a span length of 10 mm (mini-flexural strength; MFS). Data were analyzed with ANOVA and Duncan's post-hoc test and the test reliability was evaluated by Weibull analysis. Results showed that there are generally no significant difference in flexural strength with the increase in the specimen width in NFS and MFS tests. However, the test reliability of flexural strength based on Weibull analysis was largely changed with the variables in the dimension of width and span length. The flexural modulus of NFS was increased as the dimension of specimens width increased while there was no trend in flexural modulus of MFS test. Overall results recommend that the evaluation of flexural properties and the reliability of dental composite resins should be performed with more than one test method.

COMPARATIVE STUDY OF PHYSICAL PROPERTIES FOR VARIOUS BAND CEMENTS (수종의 밴드 접착 시멘트의 물성에 대한 비교 연구)

  • Yang, Kyu-Ho;Kim, Ki-Baek;Kim, Seon-Mi;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.427-432
    • /
    • 2009
  • The aim of this study was to compare the shear-peel strength and the fracture site of 5 commercially available orthodontic band cements. One hundred molar bands were cemented to extracted human 3rd molars. The specimens were prepared in accordance with the manufacturer's instructions for each cement. After storage in a humidor at $37^{\circ}C$ for 24 hours, the shear debonding force was assessed for each specimen using an universal testing machine with crosshead speed of 2 mm/minute. Maximal failure stress was converted to mean shear-peel strength, MPa. The predominant site of band failure was recorded visually for all specimens as either at the band/cement or cement/enamel interface. Mean shear-peel strength of Ormco was the highest(2.44${\pm}$0.57), followed by Fuji $Ortho^{TM}$(2.24${\pm}$0.50), $Ketac-Cem^{TM}$(2.10${\pm}$0.57), 3M $Unitek^{TM}$(1.82${\pm}$0.43), $Band-Lok^{TM}$(1.73${\pm}$0.28). There were statistically significant differences between Ormco and $Band-Lok^{TM}$, Ormco and 3M $Unitek^{TM}$, and Fuji $Ortho^{TM}$ and $Band-Lok^{TM}$(p<0.05). The predominant site of bonding failure for bands cemented with the Ormco was at the band/cement interface, whereas bands cemented with Ultra $Band-Lok^{TM}$ failed predominantly at the enamel/cement interface. There was no significant difference among the other cements(Fuji $Ortho^{TM}$, 3M $Unitek^{TM}$, $Ketac-Cem^{TM}$).

  • PDF

Heavy Metal Content and its Change in Open Storage of Canned Orange Juice (캔 오렌지쥬스의 중금속 함량 및 개봉 저장 중의 변화)

  • Lee, Hye-Sun;Lee, Su-Rae
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.165-170
    • /
    • 1993
  • The average concentration of Pb in 53 samples of canned orange juice currently sold in Korean market was 0.225 mg/kg, and that of Sn, 40.7 mg/kg. There was no appreciable difference in Pb concentration according to elapsed time after manufacturing, whereas Sn concentration increased 0.66 mg/kg per month. During the storage at room temperature or in refrigerator after opening, the Pb concentration increased slowly, reaching 1.7 to 1.8 times of original concentration, whereas Sn concentration increased by 20% per day, resulting in 3 times of original concentration after 7 days. There were no serious changes in Pb and Sn concentration in storage at room temperature or refrigerator for 3 days, when juice samples were opened and transferred to glass container. It is needed that detailed inspection by undertaken to monitor the contents of heavy metals in canned orange juice, since 18% of samples within recommended distribution period exceeded the legal standard for Pb, and recommended that more attention be paid in handling canned orange juice after opening, in order to avoid the hazard from heavy metals.

  • PDF

COMPARATIVE STUDY ON THE DETECTION OF PORPHYROMONAS ENDODONTALIS BY ANAEROBIC CULTURE, IIF AND DNA PROBE METHOD IN INFECTED ROOT CANALS (감염 근관에서 혐기성 배양법과 간접 면역 형광법 및 DNA 프로브법에 의한 Porphyromonas endodontalis의 검출에 관한 비교 연구)

  • Kim, Min-Kyum;Yoon, Soo-Han;Chung, Chong-Pyoung
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.1-18
    • /
    • 1996
  • There are many advantages when using IIF and DNA probe methods over anaerobic culture method in that they are time-and effort-saving, more precise and more sensitive. Furthermore, in IIF and DNA probe methods, the detection is possible only with small amount of bacteria, the quantitative analysis is possible, and the cell viability is not necessary. The purpose of this study is to observe the incidence of P.endodontalis by carrying out anaerobic culture, IIF and colony lift using DNA probe method respectively, and to compare these 3 methods in terms of effectiveness and sensitivity in order to identify the most effective detection method. 30 teeth with at least one clinical symptoms, with single canal, and with pulp necrosis were sampled. For sampling bacteria, access cavity was prepared after disinfecting tooth and its surroundings. Then the paper point was inserted up to the periapical area, leave there for a while, and finally it was placed into PRAS Ringer's sol. and PBS sol. In anaerobic culture method, P.endodontalis was identified by biochemical tests after subculturing black and brown colonies which were produced after 7 days of incubation on BAP and Brucella BAP in anaerobic chamber. To identify P.endodontalis in IIF method, species-specific polyclonal rabbit-antisera of P.endodontalis(ATCC 35406) was reacted with sampled PBS sol. dispensed onto glass slide, and then P.endodontalis was examined by phase contrast microscopy after incubating with Goat anti-rabbit lgG conjugated to Fluorescein isothiocyanate. For colony lift using DNA probe method, membranes were laid over colonies on the surface of BAP and were hybridized with cloned DNA probe of P.endodontalis. The existence of P.endodontalis was then identified by the methods of chemiluminescent detection and color metric detection. Black colony was found in 11 teeth out of 30 teeth and P.endodontalis was detected in 6 teeth (20 %) by anaerobic culture method, 16 teeth (53 %) by IIF method, and 7 teeth (23 %) by DNA probe method. IIF method is significantly better in detecting P.endodontalis than DNA probe method and anaerobic culture method. There was no significant differences between DNA probe method and anaerobic culture method. There was significant correlation between the formation of black colony and the existence of P.endodontalis. The probability of detecting P.endodontalis when black colony being present is 2.89 times higher than when not being present. There was significant relationship between the foul odor of clinical symptoms and P.endodontalis. The sensitivity of existing P.endodontalis when foul odor being present was 93.75 %, while the specificity of not existing P.endodontalis when foul odor not being present was 28.57 %. These results suggested that the probes of P.endodontalis will be used to decide the method and prognosis in endodontic treatments.

  • PDF

MICROLEAKAGE TEST ACCORDING TO ACID ETCHING TREATMENT IN CLASS V COMPOMERS (치면 산처리가 V급 와동의 compomer 수복에서 미세누출에 미치는 영향)

  • Moon, Sang-Hee;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.351-360
    • /
    • 2000
  • The purpose of this study was to evaluate the microleakage of class V compomers according to acid etching treatment and treatment times. Extracted 180 sound human molar teeth were selected then prepared physiologic pulpal pressure far this experiment. In this study class V cavities were prepared on buccal surface with gingival margin located in 1mm superior to CEJ under simulate physiological conditions. These specimens were randomly divided into 6 groups of 30 each and restored following methods : A: Dyract AP + Prime&Bond 2.1 Group 1 : No acid etching, according to manufacturer's instruction. Group 2 : 15 seconds acid etching and same method with Group 1. Group 3 : 30 seconds acid etching and same method with Group 1. B: F2000 groups + Single Bond adhesive Group 1 : No acid etching, according to manufacturer's instruction. Group 2 : 15 seconds acid etching and same method with Group 1 Group 3 : 30 seconds acid etching and same method with Group 1. After 500 thermocycling between $5^{\circ}C\;and\;55^{\circ}C$, the specimens were sealed with glass ionomer and nail varnish then placed in 5% methylene blue dye for 5 hours and rinsed with tab water. The specimens were embedded in orthodontic clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimens were then observed with a stereomicroscope at $\times20$ magnification. The results of this study were statistically analyzed using the indepedent sample t-test and analysis of variance. Results were as follows, 1. In occlusal walls, microleakage were significantly reduced in acid etched group restored with Dyract AP but no statistically significance in F2000 groups. 2. In gingival walls, microleakage were significantly reduced in group 2 restored with Dyract AP, and group 2 and group 3 in F2000 groups. 3. All groups, except group 3 in Dyract AP, showed significantly less microleakage in occlusal wall than gingival wall. 4. No statistical significance were showed between group 2 and group 3 in both materials.

  • PDF

Properties of Indium Tin Oxide Thin Films According to Oxygen Flow Rates by γ-FIB System (γ-FIB 시스템을 이용한 산소 유량 변화에 따른 산화인듐주석 박막의 특성 연구)

  • Kim, D.H.;Son, C.H.;Yun, M.S.;Lee, K.A.;Jo, T.H.;Seo, I.W.;Uhm, H.S.;Kim, I.T.;Choi, E.H.;Cho, G.S.;Kwon, G.C.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.6
    • /
    • pp.333-341
    • /
    • 2012
  • Indium Tin Oxide (ITO) thin films were prepared by RF magnetron sputtering with different flow rates of $O_2$ gas from 0 to 12 sccm. Electrical and optical properties of these films were characterized and analyzed. ITO deposited on soda lime glass and RF power was 2 kW, frequency was 13.56 MHz, and working pressure was $1.0{\times}10^{-3}$ Torr, Ar gas was fixed at 1,000 sccm. The transmittance was measured at 300~1,100 nm ranges by using Photovoltaic analysis system. Electrical properties were measured by Hall measurement system. ITO thin films surface were measured by Scanning electron microscope. Atomic force microscope surface roughness scan for ITO thin films. ITO thin films secondary electron emission coefficient(${\gamma}$) was measured by ${\gamma}$-Focused ion beam. The resistivity is about $2.4{\times}10^{-4}{\Omega}{\cdot}cm$ and the weighted average transmittance is about 84.93% at 3 sccm oxygen flow rate. Also, we investigated Work-function of ITO thin films by using Auger neutralization mechanism according to secondary electron emission coefficient(${\gamma}$) values. We confirmed secondary electron emission peak at 3 sccm oxygen flow rate.

The Spectrum of CT Findings of COVID-19 Pneumonia: Acute Alveolar Insult and Organizing Pneumonia as Different Phases of Lung Injury and Repair (COVID-19 폐렴의 다양한 CT 영상 소견: 급성 폐포 손상과 기질화 폐렴)

  • Yun Su Kim;Ung Rae Kang;Young Hwan Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.359-370
    • /
    • 2021
  • Purpose To analyze the findings and serial changes in chest CT lesions in 123 symptomatic patients with coronavirus disease 2019 (COVID-19). Materials and Methods From February 19 to April 7, 2020, a total of 123 confirmed COVID-19 patients (male, 44; female, 79; mean age, 59.2 ± 18.6) were enrolled in this retrospective study. A total of 234 CT scans were reviewed for the following patterns: acute alveolar insult (AAI) patterns: ground-glass opacity (GGO), crazy-paving appearance, mixed pattern, and consolidation; organizing pneumonia (OP) patterns: perilobular patterns, band opacity, curvilinear opacity, reversed halo opacity, and small nodular consolidation; resolving patterns: pure GGO, remnant curvilinear, small nodular consolidation, and serial changes of lung abnormalities. We compared the proportions of AAI pattern, OP pattern, or resolving pattern with time progression and analyzed the association between the patterns and disease severity using Pearson chi-square and Fisher's exact test. Results Predominant CT patterns were AAI pattern (87%) in the early hospital period group (0-10 days, after the onset of symptoms), OP pattern (45.7%) in the later hospital period group (after 10 days), and resolving pattern in discharge and follow-up group (47.2% and 84.8%, respectively). The difference in the proportions of predominant CT patterns with time progression was statistically significant (p < 0.001, Pearson's chi-square test). No statistically significant association was observed between the patterns and disease severity (p = 0.055, Fisher's exact test). No fibrous changes in the lesions were observed on follow-up CT scans. Conclusion The serial CT scans of COVID-19 patients showed the spectrum of COVID pneumonia CT manifestations as different phases of lung injury and repair.

Effect of Highly Concentrated Turbid Water on the Water Quality and Periphytic Diatom Community in Artificial Channel (인공수로에서 고농도 탁수가 수질 및 부착 규조류 군집에 미치는 영향)

  • Yoon, Sung-Ae;You, Kyung-A;Park, Ji-Hyoung;Kim, Baik-Ho;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.44 no.1
    • /
    • pp.75-84
    • /
    • 2011
  • We examined the effect of the turbid water on the periphytic diatom community in an artificial stream system. The artificial stream was constructed with transparent acryl and composed of four channels. Each channel ($20\;cm{\times}200\;cm{\times}40\;cm$) was supplied continuously with eutrophic lake water. In order to the freely colonize and grow diatoms, artificial substrate was installed with commercial slide glass soaked in 1% agar. Prior to introducing turbid water, the artificial stream was operated with lake water for 6 days to permit the propagation of diatom community on the substrates. The turbid water prepared with sediment sieved with ${\varphi}$ $64\;{\mu}m$ at $2\;g\;L^{-1}$ (final concentration, 300 NTU) was provided daily for 50 minute duration. The experiment was conducted for 7 days with manipulated experimental condition of light ($50{\sim}80\;{\mu}mol\;m^{-2}s^{-1}$, light:dark=24:0), temperature ($10{\pm}1^{\circ}C$), and flow rate ($0.31\;cm\;s^{-1}$). Sampling and analysis were conducted daily for water quality and diatom. Turbidity of the water varied 162.2~173.2 NTU during the experiment. After introduction of turbid water, DO, pH and TN were decreased, while SS and TP increased significantly. A total of 14 genera and 47 species of diatoms was observed on the artificial substrates during the experimental period. Of these, Navicula appeared to be a most dominant genus with 10 species, followed by Cymbella (6 species), Fragilaria (6 species) and Gomphonema (5 species). Achnanthes minutissima was the most dominant species (>70% of total frequency) in both control and treatment experiments. Increase in diatom abundance lasted for three days since turbid water introduction, after that they gradually decreased by the termination of the experiment. These results suggest that frequent supply of highly-concentrated turbid water significantly decreases the periphytic diatom community, and retard the recovery of the stable food-web within the stream.