• Title/Summary/Keyword: Run-time test

Search Result 276, Processing Time 0.027 seconds

Comparison of alarm systems for advanced control room

  • Lee, H.C.;Oh, I.S.;Sim, B.S.;Koo, I.S.;Kim, J.T.;Lee, K.Y.;Park, J.K
    • Proceedings of the ESK Conference
    • /
    • 1997.10a
    • /
    • pp.303-309
    • /
    • 1997
  • This study is carried out to investigate performance differences between two alarm presentation methods from the viewpoint of human factors and to provide items to be improved. One of the alarm display methods considered in this study displays alarm lists on VDT combined with hardwired alarm panels. The other method displays alarms on plant mimic diagrams of VDT. This alarm display method has other features for operator aid with which operator can get detailed information on the activated alarm in the mimic diagrams, and the capability for alarm processing such as alarm reduction and prioritization. To compare the twodisplay methods, a human factor experiment was performed with a plant simulator in the ITF(Integrated Test Fcility) that plant operators run for 4 event scenarios. During the experiment, physiological measurements, system and operator action log, and audio/video recordings were collected. Operators' subjective opinion was collected as well after the experiment. Time, error rate and situation awareness were major human factor criteria used for the comparison during the analysis stage of the experiment. No statistical significance was found in the results of our statistical comparison analysis. Several findings were identified, however, through the analysis of subjective opinions.

  • PDF

Long-term clinical and radiographic outcomes of arthroscopic acromioclavicular stabilization for acute acromioclavicular joint dislocation

  • Eduard Van Eecke;Bernard Struelens;Stijn Muermans
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.2
    • /
    • pp.219-228
    • /
    • 2024
  • Background: Standard open acromioclavicular (AC) stabilization is associated with increased postoperative complications including deltoid injury, infection, tunnel complications, loss of reduction, and wound/cosmetic concerns. Arthroscopy may offer superior visualization and advantages that limit these risks. The aim of this prospective non-randomized study is to evaluate advantages and long-term reliability of arthroscopic AC stabilization. Methods: Thirty-two patients with acute grade III, IV and V AC dislocations underwent arthroscopic AC reconstruction with long-term assessment by clinical AC examination, Simple Shoulder Test, American Shoulder and Elbow Surgeons scores, visual analog scale, Specific AC Score and Quick Disabilities of the Arm, Shoulder and Hand scores. Radiographs verified conservation of initial reduction and presence of coracoclavicular (CC) ossifications. Complications, revision rate, and satisfaction were assessed and compared to the literature. Results: Mean follow-up time was 67.6 months. All clinical outcome scores improved and differences were statistically significant (P<0.001). Initial postoperative radiographs consistently showed complete reduction. Two patients experienced relapse to grade II AC dislocation without clinical implications. In total, 71.8% showed CC ossifications without functional impairment, and in 31.3% concomitant injuries were observed. Reintervention rate was 9.4%, and 96.9% of patients were satisfied with procedure outcomes. Conclusions: Arthroscopic stabilization for acute AC joint dislocations offers satisfactory clinical and radiographic outcomes, and our results show that the arthroscopic technique is reliable in the long run. We report better reduction in maintenance, fewer complications, and similar reoperation rates compared to other techniques.

The influence of Brexit on Container Volume of Korea (브렉시트(Brexit)의 한국 컨테이너물동량에 대한 영향)

  • Choi, Bong-Ho;Lee, Gi-Whan
    • Journal of Korea Port Economic Association
    • /
    • v.32 no.3
    • /
    • pp.67-81
    • /
    • 2016
  • This paper examines the influence of Brexit on container volume of Korea, especially of macroeconomic variables such as exchange rate and industrial production of EU and United Kingdom. To do this, we use monthly time series data during 2000-2016, and introduce the analysis method of cointegration test and VECM, and analyze the influence of industrial production and exchange rate of EU and U.K. on container volume of Korea. The results are as follows. First, the container volume of Korea is influenced by the exchange rate and industrial production of EU in the long run. But the exchange and industrial production of U.K. influenced on only export container volume of Korea, and the influence of U.K. macroeconomic variables on container volume of Korea was not large in the long lun. Second, In the shot run, the influence of exchange rate on container volume of Korea, especially on export container volume was significant in EU and U.K. To sum up, the influence of EU macroeconomic variables on container volume of Korea is larger than that of U.K., and the influence of exchange rate variable is more significant than that of industrial production variable.

Investigation on Granger Causality between Economic Growth and Demand for Electricity in Korea: Using Quarterly Data (한국의 경제성장과 전력수요간의 인과성에 관한 연구: 분기별 자료를 이용하여)

  • Baek, Moon-Young;Kim, Woo-Hwan
    • The Korean Journal of Applied Statistics
    • /
    • v.25 no.1
    • /
    • pp.89-99
    • /
    • 2012
  • This study investigates the Granger-causality between economic growth and demand for electricity in Korea, using two quarterly time-series data (real GDP and electricity consumption) for 1970:Q1 through 2009:Q4. We apply Hsiao's sequential procedure to identify a vector autoregressive model to a decision of the optimal lags in the vector error-correction model because the two time-series data contain unit roots respectively and they are cointegrated. According to the empirical results in this study, we find that Hsiao's approach to the Granger-causality indicates a bidirectional causal relation between economic growth and demand for electricity in Korea. Following the Granger and Engle's approach, we also find the statistical evidence on (1) short-run bidirectional causality between real GDP and electricity consumption, (2) bidirectional strong causality between them, and (3) long-run unidirectional causality running from demand for electricity to economic growth. Our results show an inconsistency with the existing studies on Korea's case; however, the results appear to provide more meaningful policy implications for the Korean economy and its strategy of sustainable growth.

Experimental study of failure mechanisms in elliptic-braced steel frame

  • Jouneghani, Habib Ghasemi;Haghollahi, Abbas;Beheshti-Aval, S. Bahram
    • Steel and Composite Structures
    • /
    • v.37 no.2
    • /
    • pp.175-191
    • /
    • 2020
  • In this article, for the first time, the seismic behavior of elliptic-braced moment resisting frame (ELBRF) is assessed through a laboratory program and numerical analyses of FEM specifically focused on the development of global- and local-type failure mechanisms. The ELBRF as a new lateral braced system, when installed in the middle bay of the frames in the facade of a building, not only causes no problem to the opening space of the facade, but also improves the structural behavior. Quantitative and qualitative investigations were pursued to find out how elliptic braces would affect the failure mechanism of ELBRF structures exposed to seismic action as a nonlinear process. To this aim, an experimental test of a ½ scale single-story single-bay ELBRF specimen under cyclic quasi-static loading was run and the results were compared with those for X-bracing, knee-bracing, K-bracing, and diamond-bracing systems in a story base model. Nonlinear FEM analyses were carried out to evaluate failure mechanism, yield order of components, distribution of plasticity, degradation of structural nonlinear stiffness, distribution of internal forces, and energy dissipation capacity. The test results indicated that the yield of elliptic braces would delay the failure mode of adjacent elliptic columns and thus, help tolerate a significant nonlinear deformation to the point of ultimate failure. Symmetrical behavior, high energy absorption, appropriate stiffness, and high ductility in comparison with the conventional systems are some of the advantages of the proposed system.

Experimental Study on Damage to Journal Bearing due to Contaminating Particles in Lubricant (윤활유 오염입자에 의한 저널 베어링 손상에 관한 실험적 연구)

  • Song, Chang Seok;Lee, Bora;Yu, YongHun;Cho, Yong Joo
    • Tribology and Lubricants
    • /
    • v.31 no.2
    • /
    • pp.69-77
    • /
    • 2015
  • Recently, there have been reports of severe symptoms of wear in bearings due to foreign substances mixed in lubricants. Therefore, studying the effects of foreign substances (such as combustion products and metallic debris) on the wear characteristics of journal bearings and proposing appropriate management standards for lubricant cleanliness have become necessary. Studies on the effect of particle size and concentration of foreign substances on surface damage have actively progressed in the recent times. These studies indicate the possibility of foreign substances causing direct wear of bearing surfaces. However, experiments conducted until now involve only basic tests such as the Pin-on-Disk test instead of those involving real bearing systems. This study experimentally examines the damage to the surface of a journal bearing due to foreign substances (combustion products and alumina) mixed with the lubricant, as well as the effect of the type and size of particles on its wear characteristics. The study uses an experimental journal bearing similar to a real bearing system for conducting the lubrication test. Hydrodynamic Lubrication (HL) numerical analysis, experiment results, and film parameters are used for calculating the operating conditions required for achieving the desired film thickness, and the results of the analysis are modified for considering the surface roughness. The run-time of the experiment is 10 min including the stabilization process. The experiment results show that alumina particles larger than the minimum film thickness cause significant surface damage.

Development and validation of LC-MS/MS for bioanalysis of hydroxychloroquine in human whole blood

  • Park, Jung Youl;Song, Hyun Ho;Kwon, Young Ee;Kim, Seo Jin;Jang, Sukil;Joo, Seong Soo
    • Journal of Biomedical and Translational Research
    • /
    • v.19 no.4
    • /
    • pp.130-139
    • /
    • 2018
  • This study aimed to analyze a high-performance liquid chromatography (HPLC) separation using a pentafluorophenyl column of parent drug hydroxychloroquine (HCQ) and its active metabolite, desethylhydroxchloroquine (DHCQ) applying to determine bioequivalence of two different formulations administered to patients. A rapid, simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for bioanalysis of HCQ and its metabolite DHCQ in human whole blood using deuterium derivative $hydroxychloroquine-D_4$ as an internal standard (IS). A triple-quadrupole mass spectrometer was operated using electrospray ionization in multiple reaction monitoring (MRM) mode. Sample preparation involves a two-step precipitation of protein techniques. The removed protein blood samples were chromatographed on a pentafluorophenyl (PFP) column ($50mm{\times}4.6mm$, $2.6{\mu}m$) with a mobile phase (ammonium formate solution containing dilute formic acid) in an isocratic mode at a flow rate of 0.45 mL/min. The standard curves were found to be linear in the range of 2 - 500 ng/mL for HCQ; 2 - 2,000 ng/mL for DHCQ in spite of lacking a highly sensitive MS spectrometry system. Results of intra- and inter-day precision and accuracy were within acceptable limits. A run time of 2.2 min for HCQ and 2.03 min for DHCQ in blood sample facilitated the analysis of more than 300 human whole blood samples per day. Taken together, we concluded that the assay developed herein represents a highly qualified technology for the quantification of HCQ in human whole blood for a parallel design bioequivalence study in a healthy male.

The Impact of Crude Oil Prices on Macroeconomic Factors in Korea

  • Yoon, Il-Hyun
    • Asia-Pacific Journal of Business
    • /
    • v.13 no.2
    • /
    • pp.39-50
    • /
    • 2022
  • Purpose - The purpose of this study is to examine how Korea's macroeconomic factors, such as GDP, CPI, Export, Import, Unemployment rate and USD/KRW exchange rate, are affected by the oil price shocks. Design/methodology/approach - This study used monthly and quarterly time-series data of each variable for the period 1983 to 2022, consisting of two sub-periods, to employ Granger causality test and GARCH method in order to identify the role of the oil price movement in macroeconomic factors in Korea. Findings - Korea's currency rate to the US dollar is negatively correlated with the price change of crude oil while the GDP change is positively correlated with the price change of crude oil with strong relationship between Export and Import in particular. The exchange rate and GDP growth are believed to be not correlated with the oil price change for the pre-GFC period. According to the Granger causality test, the price change in crude oil has a causal impact on CPI, Export and Import while other factors are relatively slightly affected. Transmission effect from the oil price to Export is found and there also exists volatility spillover from oil price to economic variables under examination. Comparing two sub-periods, CPI and Export volatility responds negatively to shocks in the oil price for the pre-GFC period while volatility of CPI and Unemployment reacts positively to the oil price shocks for the post-GFC period. Research implications or Originality - The findings of this study could be helpful for both domestic and international investors to build their portfolio for the risk management since rising WTI price can be interpreted as a result of global economic growth and ensuing increase in the worldwide demand of the crude oil. Consequently, the national output is expected to increase and the currency is also expected to be strong in the long run.

A Study of PLC Simulation for Automobile Panel AS/RS (자동차 패널 자동창고 시스템의 PLC 시뮬레이션 적용 연구)

  • Ko, Min-Suk;Koo, Lock-Jo;Kwak, Jong-Geun;Hong, Sang-Hyun;Wang, Gi-Nam;Park, Sang-Chul
    • Journal of the Korea Society for Simulation
    • /
    • v.18 no.3
    • /
    • pp.1-11
    • /
    • 2009
  • This paper illustrates a case study of PLC logic simulation in a car manufacturing system. It was developed to simulate and verify PLC control program for automobile panel AS/RS. Because car models become varied, the complexity of supply problem is increasing in the car manufacturing system. To cope with this problem, companies use the AS (automated storage) and RS (retrieval system) but it has logical complexity. Industrial automated process uses PLC code to control the AS/RS, however control information and control codes (PLC code) are difficult to understand. This paper suggests a PLC simulation environment, using 3D models and PLC code with realistic data. Data used in this simulation is based on realistic 3D model and I/O model, using actual size and PLC signals, respectively. The environment is similar to a real factory; users can verify and test the PLC code using this simulation before the implementation of AS/RS. Proposed simulation environment can be used for test run of AS/RS to reduce implementation time and cost.

Chemical and Microbiological Quality, Capillary Electrophoresis Pattern, and Rennet Coagulation of UHT-treated and Irradiated Milk

  • Ham, Jun-Sang;Shin, Ji-Hye;Noh, Young-Bae;Jeong, Seok-Geun;Han, Gi-Sung;Chae, Hyun-Seok;Yoo, Young-Mo;Ahn, Jong-Nam;Lee, Wan-Kyu;Jo, Cheo-Run
    • Food Science and Biotechnology
    • /
    • v.17 no.1
    • /
    • pp.58-65
    • /
    • 2008
  • To see the possibility of irradiation as an alternative to ultra high temperature (UHT) sterilization, the quality characteristics of milk were analyzed. Milk treated by UHT ($135^{\circ}C$ for 4 sec) and irradiation at higher than 3 kGy showed no viable counts after 7 days of storage at $4^{\circ}C$. The contents of certain amino acids of milk, such as Arg, Asp, Glu, Ile, Leu, Lys, Pro, Ser, Thr, and Tyr, were lower in irradiated groups at 10 kGy than in UHT-treated one, but no difference was observed between irradiated milks at less than 5 kGy and UHT. The capillary electrophoresis (CE) patterns of the milk irradiated at 10 kGy showed a similar trend to the raw milk, low temperature long time (LTLT, $63^{\circ}C$ for 30 min), and high temperature short time (HTST, $72^{\circ}C$ for 15 sec) treated. However, the CE pattern of UHT-treated milk was different. Rennet coagulation test agreed with the CE results, showing that all milk samples were coagulated by rennet addition except for UHT-treated milk after 1 hr. These results suggest that irradiation of milk reduce the content of individual amino acids but it may not induce severe conformational change at a protein level when compared with UHT treatment.