• Title/Summary/Keyword: Roughness of surface

Search Result 5,179, Processing Time 0.042 seconds

Tactile Sensibility Factors of Traditional Silk Fabrics (전통 견직물의 촉각적 감성요인)

  • Yi, Eun-Jou
    • Science of Emotion and Sensibility
    • /
    • v.10 no.1
    • /
    • pp.99-111
    • /
    • 2007
  • In order to identify tactile sensibility factors of traditional silk fabrics and to provide prediction models for the sensibility factors by mechanical properties, seventeen different traditional silk fabrics were evaluated in terms of both tactile sensation and sensibility by using a modified magnitude estimation line scale Gongdan and Newttong with lower values for surface roughness(SMD), bending rigidity(B), and compression resilience(RC) were rated as softer, smoother, fluffier, and more pliable in tactile sensation than any other traditional silk fabrics whereas Nobangju haying higher B, SMD, and tensile resilience(RT) was touched as crisper, more rustling, and springier. Three different tactile sensibility factors including 'Feminine', 'Natural', and 'Casual' were obtained significantly by grouping fifteen different tactile sensibility descriptors. In the prediction models sensibility 'Feminine' was explained positively by SMD, which was supported by the fact that both Gongdan and Newtton were perceived as more feminine. Sensibility 'Natural' that was felt stronger as for Myoungju and Sa was predicted negatively by both fabric thickness(T) and RT. Finally, RC, elongation at maximum load (EM), and T predicted sensibility 'Casual' negatively, which results in its higher factor scores for Myoungju and Shantung, respectively.

  • PDF

InAlGaAs 장벽층의 상분리 현상에 따른 InAs 나노 양자점의 성장거동 연구

  • Jo, Byeong-Gu;Kim, Jae-Su;Lee, Gwang-Jae;Park, Dong-U;Kim, Hyeon-Jun;Hwang, Jeong-U;O, Hye-Min;Kim, Jin-Su;Choe, Byeong-Seok;O, Dae-Gon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.165-165
    • /
    • 2010
  • $1.55\;{\mu}m$ 대역의 레이저 다이오드를 제작하기 위해, InP(001) 기판에 InAlGaAs 물질을 장벽층으로 하는 InAs 양자점 구조를 분자선증착기 (MBE)를 이용하여 성장하고 구조 및 광학적 특성을 Double Crystal X-ray Diffraction (DCXRD), Atomic Force Microscopy (AFM), Photoluminescence (PL)을 이용하여 평가하였다. 일반적으로 InAlGaAs 물질은 고유한 상분리 현상 (Phase Separation)이 나타나는 특성이 있으며, 이는 양자점 성장에 중요한 요인으로 작용할 수 있다. 이러한 InAlGaAs 물질의 상분리 현상을 기판온도 ($540^{\circ}C$, $555^{\circ}C$, $570^{\circ}C$)를 비롯한 성장변수를 변화시켜 제어하고 InAs 양자점 형성에 어떠한 영향을 미치는지를 분석하였다. 540의 성장온도에서 InP(001) 기판에 격자정합한 InAlGaAs 장벽층이 성장온도를 $570^{\circ}C$로 증가시킬 경우 기판에 대하여 인장 응력 (Tensile Strain)을 받는 구조로 변화되었다. 인장응력을 받는 InAlGaAs 장벽층을 Ga Flux 양을 조절하여 격자정합한 InAlGaAs 층을 형성할 수 있었다. AFM을 통한 표면 형상 분석 결과, 서로 다른 기판온도에서 성장한 InAlGaAs 물질이 InP(001) 기판에 격자정합 조건일지라도 표면의 거칠기 (Surface Roughness)는 매우 다른 양상을 보였고 InAs 양자점 형성에 직접적으로 영향을 주었다. $570^{\circ}C$에서 성장한 InAlGaAs 위에 형성한 InAs 양자점의 가로방향 크기를 세로방향 크기로 나눈 비율이 1.03으로서, 555와 $540^{\circ}C$의 1.375 와 1.636와 비교할 때 모양 대칭성이 현저히 개선된 것을 알 수 있다. 상분리 현상이 줄어 표면 거칠기가 좋은 InAlGaAs 위에 양자점을 형성할 때 원자들의 이동도가 상대적으로 높아 InAs 양자점의 크기가 증가하고, 밀도가 감소하는 현상이 나타났다. 또한 InAlGaAs 장벽층이 InP(001) 기판을 기준으로 응력 (Compressive 또는 Tensile)이 존재하는 경우, InAs 양자점 모양이 격자정합 조건 보다 비대칭적으로 변하는 특성을 보여 주었다. 이로부터, 대칭성이 개선된 InAs 양자점 형성에 InAlGaAs 장벽층의 표면 거칠기와 응력이 중요한 변수로 작용함을 확인 할 수 있었다. PL 측정 결과, 발광파장은 $1.61\;{\mu}m$로 InAs 양자구조 형상에 따라 광강도 (Intensity), 반치폭 (Line-width broadening) 등이 변화 되었다.

  • PDF

An in-vitro wear study of human enamel opposing heat-pressed ceramics (2종의 열가압 도재와 법랑질 간의 마모에 관한 연구)

  • Park, Chan-Yong;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.21-28
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the wear characteristics of human enamel opposing 2 heat-pressed ceramics (e.max Press and Empress Esthetic), conventional feldspathic porcelain (Ceramco 3) and type III gold alloy. Material and methods: Intact cusps of extracted premolars were used for enamel specimens. Five disk samples were made for each of two heat-pressed ceramics groups, conventional feldspathic porcelain group and type III gold alloy group. Wear tests were conducted in distilled water using a pin-on-disk tribometer. The amount of enamel wear was determined by weighing the enamel specimens before and after wear tests, and the weight was converted to volumes by average density. The wear tracks were analyzed by scanning electron microscopy and surface profilometer to elucidate the wear characteristics. Results: 1. Ceramco 3 led to the greatest amount of enamel wear followed by Empress Esthetic, e.max Press and type III gold alloy. However, there was no significant difference between Ceramco 3 and Empress Esthetic (P>.05), and there were also no significant differences among Empress Esthetic, e.max Press and type III gold alloy (P>.05). 2. The average surface roughness of e.max Press after wear test was smallest followed by Empress Esthetic and Ceramco 3, but there was no significant difference between Empress Esthetic and Ceramco 3 (P>.05). 3. There were no significant differences among the depth of wear tracks of all the groups (P>.05). The group that showed the largest width of wear track was Ceramco 3 followed by Empress Esthetic, e.max Press and type III gold alloy. However, there was no significant difference between e.max Press and Empress Esthetic (P>.05), and there was also no significant difference between Empress Esthetic and Ceramco 3 (P>.05). Conclusion: Within the limits of this study, heat-pressed ceramics were not more abrasive than conventional feldspathic porcelain.

Dry Etching of Flexible Polycarbonate and PMMA in O2/SF6/CH4 Discharges (O2/SF6/CH4 플라즈마를 이용한 플렉시블 Polycarbonate와 PMMA의 건식 식각)

  • Joo, Y.W.;Park, Y.H.;Noh, H.S.;Kim, J.K.;Lee, J.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.2
    • /
    • pp.85-91
    • /
    • 2009
  • There has been a rapid progress for flexible polymer-based MEMS(Microelectromechanical Systems) technology. Polycarbonate (PC) and Poly Methyl Methacrylate (PMMA), so-called acrylic, have many advantages for optical, non-toxic and micro-device application. We studied dry etching of PC and PMMA as a function of % gas ratio in the $O_2/SF_6/CH_4$ temary plasma. A photoresist pattern was defined on the polymer samples with a mask using a conventional lithography. Plasma etching was done at 100 W RIE chuck power and 10 sccm total gas flow rate. The etch rates of PMMA were typically 2 times higher than those of PC in the whole experimental range. The result would be related to higher melting point of PC compared to that of PMMA. The highest etch rates of PMMA and PC were found in the $O_2/SF_6$ discharges among $O_2/SF_6$, $O_2/CH_4$ and $SF_6/CH_4$ and $O_2/SF_6/CH_4$ plasma composition (PC: ${\sim}350\;nm/min$ at 5 sccm $O_2/5$ sccm $SF_6$, PMMA: ${\sim}570\;nm/min$ at 2.5 sccm $O_2/7.5$ sccm $SF_6$). PC has smoother surface morphology than PMMA after etching in the $O_2/SF_6/CH_4$ discharges. The surface roughness of PC was in the range of 1.9$\sim$3.88 nm. However, that of PMMA was 17.3$\sim$26.1 nm.

Properties of Indium Tin Oxide Thin Films According to Oxygen Flow Rates by γ-FIB System (γ-FIB 시스템을 이용한 산소 유량 변화에 따른 산화인듐주석 박막의 특성 연구)

  • Kim, D.H.;Son, C.H.;Yun, M.S.;Lee, K.A.;Jo, T.H.;Seo, I.W.;Uhm, H.S.;Kim, I.T.;Choi, E.H.;Cho, G.S.;Kwon, G.C.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.6
    • /
    • pp.333-341
    • /
    • 2012
  • Indium Tin Oxide (ITO) thin films were prepared by RF magnetron sputtering with different flow rates of $O_2$ gas from 0 to 12 sccm. Electrical and optical properties of these films were characterized and analyzed. ITO deposited on soda lime glass and RF power was 2 kW, frequency was 13.56 MHz, and working pressure was $1.0{\times}10^{-3}$ Torr, Ar gas was fixed at 1,000 sccm. The transmittance was measured at 300~1,100 nm ranges by using Photovoltaic analysis system. Electrical properties were measured by Hall measurement system. ITO thin films surface were measured by Scanning electron microscope. Atomic force microscope surface roughness scan for ITO thin films. ITO thin films secondary electron emission coefficient(${\gamma}$) was measured by ${\gamma}$-Focused ion beam. The resistivity is about $2.4{\times}10^{-4}{\Omega}{\cdot}cm$ and the weighted average transmittance is about 84.93% at 3 sccm oxygen flow rate. Also, we investigated Work-function of ITO thin films by using Auger neutralization mechanism according to secondary electron emission coefficient(${\gamma}$) values. We confirmed secondary electron emission peak at 3 sccm oxygen flow rate.

Human Thermal Environment Analysis with Local Climate Zones and Surface Types in the Summer Nighttime - Homesil Residential Development District, Suwon-si, Gyeonggi-do (Local Climate Zone과 토지피복에 따른 여름철 야간의 인간 열환경 분석 - 경기도 수원시 호매실 택지개발지구)

  • Kong, Hak-Yang;Choi, Nakhoon;Park, Sookuk
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.4
    • /
    • pp.227-237
    • /
    • 2020
  • Microclimatic data were measured, and the human thermal sensation was analyzed at 10 local climate zones based on the major land cover classification to investigate the thermal environment of urban areas during summer nighttime. From the results, the green infrastructure areas (GNIAs) showed an average air temperature of 1.6℃ and up to 2.4℃ lower air temperature than the gray infrastructure areas (GYIAs), and the GNIAs showed an average relative humidity of 9.0% and up to 15.0% higher relative humidity. The wind speed of the GNIAs and GYIAs had minimal difference and showed no significance at all locations, except for the forest location, which had the lowest wind speed owing to the influence of trees. The local winds and the surface roughness, which was determined based on the heights of buildings and trees, appeared to be the main factors that influenced wind speed. At the mean radiant temperature, the forest location showed the maximum value, owing to the influence of trees. Except at the forest location, the GNIAs showed an average decrease of 5.5℃ compared to GYIAs. The main factor that influenced the mean radiant temperature was the sky view factor. In the analysis of the human thermal sensation, the GNIAs showed a "neutral" thermal perception level that was neither hot nor cold, and the GYIAs showed a "slightly warm" level, which was a level higher than those of the GNIAs. The GNIAs showed a 3.2℃ decrease compared to the GYIAs, except at the highest forest location, which indicated a half-level improvement in the human thermal environment.

Precipitation of $CaCO_3$ Crystals from Variously Supersaturated Solutions (다양한 과포화 조건하에서의 탄산염광물의 합성에 대한 연구)

  • Hyeon Yoon;Kim, Soo-Jin
    • Journal of the Mineralogical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.11-21
    • /
    • 2004
  • Crystallization of CaC $O_3$ from the solutions of various degrees of supersaturation was carried out by a spontaneous precipitation method. The solution was kept at $25^{\circ}C$ and pH 6.9∼8.8. The solution compositions were varied in two ways: (1) The total carbonate, [C $O_3$]$_{Τ}$, to total calcium. [Ca]$_{Τ}$, ratios vary as ; [C $O_3$]$_{Τ}$/[Ca]$_{Τ}$ >1. [C $O_3$]$_{Τ}$/[Ca]$_{Τ}$=1, and [C $O_3$]$_{Τ}$/[Ca]$_{Τ}$<1. (2) The total calcium concentration, [Ca]$_{Τ}$, held at 0.02 mo1/d $m^3$, 0.2 mo1/d $m^3$, and 0.4 mo1/d $m^3$. We found that the CaC $O_3$ phase crystallized from the solutions of [C $O_3$]$_{Τ}$/[Ca]$_{Τ}$ $\geq$ 1 was mostly calcite with less than 1% of vaterite, while the CaC $O_3$ crystals precipitated from low carbonate concentration toward calcium concentration, [C $O_3$]$_{Τ}$/[Ca]$_{Τ}$ < 1, were dominated by vaterite crystals. It appears that the polymorph of CaC $O_3$ precipitate was mainly controlled not by the calcium concentration but by the carbonate concentration during the spontaneous precipitation. Also, we found that the surface roughness of vaterite increased with decreasing carbonate concentration from 0.8 or 0.5 of [C $O_3$]$_{Τ}$/[Ca]$_{Τ}$ ratios and the surface area of vaterite increased from 5.64∼7.34 $\mu\textrm{m}$ to 8.39∼10.3 $\mu\textrm{m}$.

Dry etching of polycarbonate using O2/SF6, O2/N2 and O2/CH4 plasmas (O2/SF6, O2/N2와 O2/CH4 플라즈마를 이용한 폴리카보네이트 건식 식각)

  • Joo, Y.W.;Park, Y.H.;Noh, H.S.;Kim, J.K.;Lee, S.H.;Cho, G.S.;Song, H.J.;Jeon, M.H.;Lee, J.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.1
    • /
    • pp.16-22
    • /
    • 2008
  • We studied plasma etching of polycarbonate in $O_2/SF_6$, $O_2/N_2$ and $O_2/CH_4$. A capacitively coupled plasma system was employed for the research. For patterning, we used a photolithography method with UV exposure after coating a photoresist on the polycarbonate. Main variables in the experiment were the mixing ratio of $O_2$ and other gases, and RF chuck power. Especially, we used only a mechanical pump for in order to operate the system. The chamber pressure was fixed at 100 mTorr. All of surface profilometry, atomic force microscopy and scanning electron microscopy were used for characterization of the etched polycarbonate samples. According to the results, $O_2/SF_6$ plasmas gave the higher etch rate of the polycarbonate than pure $O_2$ and $SF_6$ plasmas. For example, with maintaining 100W RF chuck power and 100 mTorr chamber pressure, 20 sccm $O_2$ plasma provided about $0.4{\mu}m$/min of polycarbonate etch rate and 20 sccm $SF_6$ produced only $0.2{\mu}m$/min. However, the mixed plasma of 60 % $O_2$ and 40 % $SF_6$ gas flow rate generated about $0.56{\mu}m$ with even low -DC bias induced compared to that of $O_2$. More addition of $SF_6$ to the mixture reduced etch of polycarbonate. The surface roughness of etched polycarbonate was roughed about 3 times worse measured by atomic force microscopy. However examination with scanning electron microscopy indicated that the surface was comparable to that of photoresist. Increase of RF chuck power raised -DC bias on the chuck and etch rate of polycarbonate almost linearly. The etch selectivity of polycarbonate to photoresist was about 1:1. The meaning of these results was that the simple capacitively coupled plasma system can be used to make a microstructure on polymer with $O_2/SF_6$ plasmas. This result can be applied to plasma processing of other polymers.

The influence of Collar design on peri-implant marginal bone tissue (Collar design이 임플랜트 주위 변연골 흡수에 미치는 영향)

  • Kim, Jee-Hwan;Jung, Moon-Kyou;Moon, Hong-Suk;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.53-64
    • /
    • 2008
  • Statement of problem: Peri-implant marginal bone loss is an important factor that affects the success of implants in esthetics and function. Various efforts have been made to reduce this bone loss by improving implant design and surface texture. Previous studies have shown that early marginal bone loss is affected by implant neck designs. Purpose: The purpose of this study was to examine the influence of laser microtexturing of implant collar on peri-implant marginal bone loss. Materials and methods: Radiographical marginal bone loss was examined in patients treated with implant-supported fixed partial dentures. Marginal bone level was examined with 101 implant fixtures installed in 53 patients at three periods(at the time of implantation, prosthetic treatment and 6-month after loading). Four types of implants were examined. The differences of bone loss between implants(ITI standard) with enough biologic width and implants(ITI esthetic plus, Silhouette IC, Silhouette IC Laser-$Lok^{TM}$) with insufficient biologic width have been compared. Resorption angles were examined at the time of prosthetic delivery and 6-month after loading. Results and Conclusion: Within the limitation of this study, the following results were drawn. 1. The marginal bone loss of ITI standard and Silhouette IC Laser-$Lok^{TM}$ was less than that of ITI esthetic plus and Silhouette IC(P<0.05). The marginal bone loss between ITI standard and Silhouette IC Laser-$Lok^{TM}$ had no significant statistical difference(P>0.05). There was no significant statistical difference between marginal bone loss of ITI esthetic plus and Silhouette IC(P>0.05). 2. There was no significant difference in marginal bone loss between maxilla and mandible(P>0.05). 3. There was no significant difference in resorption angle among four types of implants(P>0.05). The marginal bone of implants with supracrestal collar design of less than that of biologic width had resorbed more than those with sufficient collar length. The roughness and laser microtexturing of implant neck seem to affect these results. If an implant with collar length of biologic width, exposure of fixture is a possible complication especially in the anterior regions of dentition that demand high esthetics. Short smooth neck implant are often recommended in these areas which may lack the distance between microgap and the marginal bone level. In these cases, the preservation of marginal bone must be put into consideration. From the result of this study, it may be concluded that laser microtexturing of implant neck is helpful in the preservation of marginal bone.

Retention of CAD/CAM Metal Copings Cemented on Short Titanium Abutments with Different Cements (짧은 티타늄 지대주에 합착된 CAD/CAM 금속 코핑의 시멘트 종류에 따른 유지력 비교)

  • Kim, Hyo-Jung;Song, Eun-Young;Yoon, Ji-Young;Lee, Si-Ho;Lee, Yong-Keun;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.119-126
    • /
    • 2012
  • State of problem: Cement-retained implant-supported prostheses are routinely used in dentistry. The use of high strength cements has become more popular with the increasing confidence in the stability of the implant-abutment screw connection and the high survival rates of osseointegrated implants. No clinical data on retention of metal copings using CAD/CAM. To evaluate retention of metal copings using CAD/CAM system bonded to short titanium abutment with four different cements and compare retentive strength of metal copings with sandblasting or without sandblasting before cementation. Forty titanium abutment blocks were fabricated and divided into 4 groups of 10 samples each. Forty metal copings with occlusal hole to allow for retention testing were fabricated using CAD/CAM technology. The four cements were Fujicem(Fuji, Japan), Maxcem Elite(Kerr, USA), Panavia F2.0(Kurarary, Japan) and Superbond C&B(Sunmedical, Japan). The copings were cemented on the titanium abutment according to manufacture's recommendation. All samples were stored for 24h at 37oC in 100% humidity and tested for retention using universal testing machine(Instron) at a crosshead speed of 1.0mm/min. Force at retentive failure was recorded in Newton. The mode of failure was also recorded. Means and standard deviations of loads at failure were analyzed using ANOVA and Paired t-test. Statistical significance was set at P<0.05. Panavia F2.0 provided significantly higher retentive strength than Fujicem, Maxcem Elite(P<0.05). Sandblasting significantly increased bond strength(P<0.05). The mode of failure was cement remaining principally on metal copings. Within the limitation of this study, Panavia F2.0 showed significantly stronger retentive strength than Fujicem, Maxcem Elite(p<0.05). The Ranking order of the cements to retain the copings was Panavia F2.0, Fujicem = Maxcem Elite. Sandblasting significantly increased bond strength(P<0.05). The retentive strength of metal copings on implant abutment were influenced by surface roughness and type of cements.