• 제목/요약/키워드: Room unit

검색결과 703건 처리시간 0.031초

대학주변 원룸형 다가구주택의 실내소음수준 실태 (Present Condition of Indoor Noise Level in One-Room Type Multi-Family Housings around Campus)

  • 최윤정
    • 한국실내디자인학회논문집
    • /
    • 제14권3호
    • /
    • pp.191-198
    • /
    • 2005
  • The present study is a preliminary research improving the dwelling quality of one-room type multi-family housings around the university campus. The purpose of the study is to investigate the present condition of Indoor noise level using · residents' responses and field measurements. The respondents are 104 residents living in one-room type multi-family housings. The field measurements on equivalent noise level of indoor and outdoor were carried out in 6 subject house units during the $26th\~28th$ of November 2002. The results are as follows. 1) The residents show relatively non-positive responses at evening and night on the present condition of indoor noise. 2) They answer 'living equipment foise' and 'water hammer' as major types of indoor noise of house unit. 3) Outdoor noise levels, basic factor of noise environment in 6 subject buildings were distributed $52.8\~65.3dB(A)Leq_{5min}$ and were inappropriate to the standard for environmental noise, $55 dB(A)Leq_{5min}$. 4) Indoor noise levels of subject house units were measured as $27.5\~63.5dB(A)Leq_{5min}$, the average of each house unit except one house unit was higher than the level feeling as noise, 40dB(A). 5) It was found that the differences of indoor noise levels between subject house units were caused by 'residents' living noise', 'living equipment noise', 'water hammer', and 'walking and talking noise in stairs and corridors'. 6) Therefore, it is required to plan for improving the quality of noise environment in one-room type multi-family housing around the campus. For example, soundproof construction (including double window with pair glass and balcony), outdoor garden with trees and water for increasing natural sound, interior materials with sound absorbing power to absorb living noise, soundproof pipe or double surface pipe for decreasing 'water hammer', and noiseproof floors, etc. are required.

COVID-19 중환자를 돌보는 간호사들의 경험 (Nurses' experiences of caring for severe COVID-19 patients)

  • 강명미;박예나;박성영;김주현
    • 중환자간호학회지
    • /
    • 제15권2호
    • /
    • pp.14-26
    • /
    • 2022
  • Purpose : This study aimed to understand and describe the nurses' experiences caring for severe COVID-19 patients at isolation room with negative pressure in South Korea. Methods : Data were collected through individual in-depth interviews from February 16 to March 31, 2021 with 11 nurses who had been caring for severe COVID-19 patients at isolation room. Verbatim transcripts were analyzed according to Colaizzi's phenomenological analysis. Results : As a result, 5 theme clusters were extracted about nurses' experiences. The 5 theme clusters, "Adapting to unexpected adversity", "Accepting unresonable and heavy work", "Dulness and disconnection from the outside world", "Changing in perception of new infectious diseases", and "Pathetic isolated patients" emerged. Conclusion : The results of this study provided a deeper understanding of nurses struggling to care for COVID-19 severe patients. This study is expected to be useful in providing basic evidence for improving intensive care practices and for preparing policies in other infection disease situations.

대전지역 공동주택의 분양 팜플렛에 나타난 계획 특성 (Content Analysis of the Planning Characteristics of Apartment Houses in Daejeon City)

  • 박정아;강인호;최병숙;정미현;장혜선
    • 한국주거학회논문집
    • /
    • 제19권3호
    • /
    • pp.11-20
    • /
    • 2008
  • The purpose of this study was to find out tendencies in the planning characteristics focused on the community, single building, shared spaces and interior concept of apartment houses in Daejeon City, and to analyze these characteristics according to apartment unit floor plan based upon the arrangement of room, the type of main entrance, the type of LDK, anbang, kitchen, bathroom and the 3rd space. This study used the content analysis method and analysis was made on drawings and descriptions showing planning characteristics of apartment houses. Above all, 34 cases of apartment houses and 159 unit plans were analyzed. The results of this study were as follows: 1) The most important characteristics of the direction of housing development was the "well-being" concept including greenzone and natural environment. The most mentioned community spaces were children's playgrounds and parks. The emphasized interior concepts were noble, well-being and natural concepts. 2) The most prominent front arrangement type was the 3-bay unit plan, front space arrangement was focused on rooms and, livingroom. The most prominent front space arrangement types were R/L/R, R/L/R/R and there is a new tendency towards KD/L/R/R. 3) The most prominent LDK floor plans were of the LDK type. The type of "Anbang" arrangement consisted mainly of room-bathroom-dressing room. The type of public bathroom arrangement consisted mainly of bathtub-toilet-washbasin and the "Anbang" bathroom arrangement was shower-booth-toilet-washbasin.

모자동실 개념을 중심으로 한 산과 병동의 건축계획에 관한 연구 (A Study on the Architectural Planning of a Maternity Ward Focused on Rooming-in System)

  • 김언화;유영민
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제8권2호
    • /
    • pp.25-33
    • /
    • 2002
  • The effects and necessity of the breast milk are well known, but the breast-feeding rate in our country is very low. One of the reason is due to the separation policy of mother and baby after delivery. The mother is in the inpatient-room and the baby is in the new-born baby room. This isolation operation of hospital get increased according to the decreasing ratio of breast feeding in Korea. Only a few hospital operates and provides the space for a new-born baby in the mother's room. The system of baby and mother in one room is adopted and operated due to the breast feeding campaign. It is very encouraging, but the space for the baby and the mother is not enough in multi-bed rooms. We should reconsider the relationship between the new-born baby unit and the obstetric ward, and design the patient's room for the baby and the mother.

  • PDF

C-arm의 Tube 위치에 따른 거리 및 방향별 피폭선량 비교 (A Comparision of the Radiation dose by Distance and the Direction according to a Tube Position of the C-arm Unit)

  • 김진수;우봉철;김성진;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.21-26
    • /
    • 2009
  • In operation room, the use of the C-arm unit is increasing. So, the radiation dose of the person who work in operation room was even more increased than before. Thus, this study is shown the measurement of expose dose and the way for decrease of the radiation dose by using the C-arm unit. The experiment was performed with the C-arm unit and used a phantom which is similar to tissue of the human body and fluoro-glass dosimeter for dose measurement. The expose dose were measured by the tube position(over tube, under tube) of the C-arm unit, distance(50, 100$\sim$200cm), direction(I, II, III, IV), runtime(1min, 3min), wearing of the apron. The radiation dose was decreased twice and three times at under tube rather than over tube. The I direction was measured 20$\sim$30% more than the others. The biggest expose dose is 50cm from center on distance. The expose dose is decreased to far from center. In case of Wearing of the apron, the radiation dose was decreased 60$\sim$90% by the distance. But there weren't change of the radiation dose by C-arm tube position. In present, by increasing the usage of the C-arm unit, the radiation dose is inevitable. So, this study recommends us to use the under tube of the C-arm unit. Also, Wearing of the apron is required for minimum of the radiation exposure.

  • PDF

단위평면의 형태요인에 따른 내부공간 가변화에 관한 분석 - 1998년 이후의 아파트를 중심으로 - (An Analytical Study on the Flexible Interior Space of Apartments according to Unit Plan Types - Focusing on Apartment Built Since 1998 -)

  • 조일아;김형우
    • 한국실내디자인학회논문집
    • /
    • 제15권5호
    • /
    • pp.120-129
    • /
    • 2006
  • Apartments have become the most popular type of residential building in Korea since the 1960s. The dwelling space should be designed to accomodate various life styles or changing needs of family members. This research is conducted to analyze flexible interior space types of apartments and to improve the architectural planning and design of apartments that can satisfy various needs of residents. In this study, apartments of 10 - 90 pyeongs built in the region of Seoul, between 1998 and 2007, are investigated in terms of the unit plan, the number of open sides, and a distribution of flexible apartment types for each year, Apartments with flexible space are classified into 10 different types, including a flexible type between bedrooms, a flexible type between a bedroom and the livingroom, and a flexible type between the dinning room and the livingroom. According to the composition of unit plans, apartments are also differentiated as a single-corridor type, a double-corridor type, a stairway type, a hall type, and a combination type. According to these classifications, the characteristics of desirable unit plans were analyzed. The results of the analysis showed that, as the unit size of apartments get bigger, the ratio of width/depth of the front side unit plan is increased. This result reflects a trend of high-rise apartments which have an increased number of front-side bays and a shorter depth for better penetration of daylight. In addition, a hall type is found to have a wider front side and shorter depth. According to open sides, a flexible type of the livingroom and the dinning room/kitchen (L-D.K) is found to be most common for the front/back open space, and the livingroom is usually placed on the front/side open space. To meet the changing needs of residents, more research should be conducted on flexible dwelling space.

연탄(煉炭)가스 중독자(中毒者)의 생활환경(生活環境)에 관(關)한 역학적(疫學的) 연구(硏究) (A Survey on the Environmental Conditions of the CO Patients treated by Hyperbaric Oxygen Therapy)

  • 김인달;윤덕로;최용어;윤인재;이철구;양요환
    • Journal of Preventive Medicine and Public Health
    • /
    • 제5권1호
    • /
    • pp.9-15
    • /
    • 1972
  • Carbon monoxide poisoning is one of the most serious health problems in Korea, because we have been encountered with the highest incidence of CO poisoning in the world due to the unique heating system in home called 'ondal'. We opened Hyperbaric chamber unit in the Seoul National University Hospital last Jan, 1969. We have treated 848 patients as of Sept. 30., 1972, around 44 months period. We collected the informations on the environmental conditions of the place where CO intoxication actually occured by filling up the questionaire from 505 patients. The following findings were obtained. 1. Age distribution showed that the highest incidence was found in the younger age group between age of 10 to age of 29 in both sex. 2. Sex ratio of the patients was 1:1.14. 3. The socio-economic level of the patient was relatively low. 4. Housewife & housemaid were the major victims of the intoxication in the female patients & in the case of the male patient, occupational backgrounds were diverse. 5. Many patients from the middle class experienced the intoxication by sleeping at newly built room. 6. Many intoxication has been occured in the structure of houses where communicating doors are existing between living room & kitchen. 7. All findings obtained taught us again that CO poisoning is the serious by-product of the national fuel policy which put emphasis on the use of coal & socio-economic status is a very important parameter in this hazards.

  • PDF

전면 2실형과 전면 3실형 아파트의 평면특성 및 만족도 비교 - 부산시 화명동 지구 전용면적 $85m^2$ 아파트를 중심으로 - (A Comparison of the Characteristics of and the Residents' Satisfaction with the Housing Unit with 2-Bay and 3-Bay - Focused on $85m^2$-Sized Housing Units in Hwamyung-dong, Busan -)

  • 방정훈;오관옥
    • 한국주거학회논문집
    • /
    • 제17권3호
    • /
    • pp.19-30
    • /
    • 2006
  • The purpose of this study was to compare the characteristics of floor plan of $85m^2$-sized housing units with 2-bay and 3-bay and the residents' satisfaction with them. The subjects for analyzing floor plan were six floor plans of $85m^2$-sized housing units with 2-bay and nine floor plans of housing units with 3-bay in the new town, Hwamyeong-dong, in Busan. The floor plans were analyzed based on seven characteristics of floor plans such as the composition type of entrance core hall, the entrance arrangement, width and depth of the housing unit, size of each room, LDK arrangement, arrangement of family bathroom and private bathroom for husband and wife, and balcony arrangement. The subjects for grasping satisfaction with each housing unit were 400 residents of $85m^2$-sized housing units. A half of them lived in housing units with 2-bay and another half of them with 3-bay in the same area. They answered about the degree of satisfaction with the characteristics of each room and the preferred floor plan type if they move to the same size housing units through a questionnaire. The results were as follows; First, the floor plan with 3-bay had more diverse elements than one with 2-bay. Second, the residents who lived in 3-bay housing unit were younger, higher education, and higher income than the ones in 2-bay. Third, the residents who lived in $85m^2$-sized housing unit were more satisfied with and preferred to 3-bay housing units than 2-bay one.

고부가가치선의 Unit Cabin Mock-up 을 이용한 캐빈소음 저감 연구 (Cabin Noise Reduction using Unit Cabin Mock-up of High Value Ship)

  • 주원호;송근복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.483-484
    • /
    • 2010
  • Unit cabin means room, which is installed in the high value ship such as drill ship and FPSO, after pre-assembled. In order to develop the noise control design for a unit cabin, a variety of acoustic tests such as sound absorption, transmission, and radiated noise measurements were carried out by using the mock-up of living quarter. From the tests, it was found out that the combined noise level of a unit cabin could be dominated by the radiated noise from wall panel in low frequency range and the design guidelines for the noise control of unit cabin were fully established, such as the improvement of sound transmission loss between the cabin and corridor, and radiated cabin noise reduction.

  • PDF

사무용 건물에서 전열교환 환기시스템과 일반공조기의 냉방에너지 비교분석에 관한 연구 (A Comparative Analysis on Cooling Energy of Heat Recovery Ventilator and Air Handling Unit in the Office Building)

  • 장지훈;김현수;어진선;이승복;김병선
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.123-128
    • /
    • 2016
  • Purpose: In order to save the energy consumption of buildings, buildings have been constructed with high performance insulation or airtightness. However, high performance insulation or air tightness has led to a poor indoor air quality. Therefore, HRV(Heat Recovery Ventilator) has received attention to save the energy consumption and insure a good air quality. Because existing research is almost about the performance of HRV in residential buildings, This study analyzed the effect of HRV on cooling energy consumption in commercial office building. Method: This study was proceeded at commercial office building in In-cheon. In order to evaluate the energy consumption of HRV, this study proposed two methods: estimating energy consumption of the room installed AHU(Air Handling Unit) system; estimating energy consumption of the room installed HRV system. Therefore, comparison of two methods was proceeded to evaluate energy performance of each method. Result: As the result of comparison between rooms installed AHU and HRV, the experiment showed that energy consumption of the room installed HRV system is about 22% less than the room of AHU system. This conclusion is considered because the room installed HRV system have maintained temperature well at set point temperature $26^{\circ}C$.