• 제목/요약/키워드: Room fire

검색결과 528건 처리시간 0.023초

공공건축물의 신재생에너지 적용과 에너지 사용량 분석 (Analysis of New & Renewable Energy Application and Energy Consumption in Public Buildings)

  • 이용호;서상현;김형진;조영흠;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.153-161
    • /
    • 2012
  • This study conducted a survey and field investigation on the application of the Public Obligation System for new & renewable energy in public buildings, as well as energy consumption of each building according to their uses. The findings are as follows: (1) Since the introduction of the Public Obligation System (until June 30, 2011), there was average 1.4 new & renewable energy facilities established at 1,433 places. Preference for solar energy facilities was the highest at 57.8%. (2) The revised act sets the obligatory supply percentage of new & renewable energy for each public building: it is 9.0% for a tax office, 4.2% for a dong office, 8.2% for a public health center, and 12.6% for a fire station. All the public buildings except for fire stations failed to meet 10% expected energy consumption, a revised standard. (3) Energy consumption of each public building was 120.6TOE for a tax office, 124.3TOE for a dong office, 166.4TOE for a public health center, and 174.6TOE for a fire station. The energy consumption was comprised of 80% electric power, 18% urban gas, and 1% oil. (4) Electric power consumption per person in the room was high at a dong office, and fuel consumption per person in the room was high at a public health center. In addition, electric power consumption per unit space was high at a public health center, and fuel consumption per unit space was high at a fire station. (5) In all the four public buildings, power load had the highest basic unit percentage at average 55%, being followed by heating load (21.2%), cooling load (15%), and water heating load (7%). A tax office and fire station had 2% load due to cooking facilities.

구획화재에서 환기조건의 변화가 화재특성에 미치는 영향(Part I: FDS의 성능평가) (Effects of Ventilation Condition on the Fire Characteristics in Compartment Fires (Part I: Performance Estimation of FDS))

  • 황철홍;박충화;고권현
    • 한국화재소방학회논문지
    • /
    • 제24권3호
    • /
    • pp.131-138
    • /
    • 2010
  • 실규모 ISO 9705 표준 화재실에서 과환기화재 및 환기부족화재에 대한 열 및 화학적 특성에 관한 실험 및 수치해석 연구가 수행되었다. 과환기화재 및 환기부족화재의 발생을 위하여 연료 유량과 출입구의 폭이 변화되었다. FDS(Fire Dynamic Simulator)의 화재현상 예측성능을 검토하기 위하여 실험과 수치해석에서 얻어진 온도 및 화학종의 농도에 대한 상세한 비교가 이루어졌다. 과환기화재 및 환기부족화재의 전반적인 특성은 연소효율, 총괄당량비뿐만 아니라 고온 상층부에서 측정된 온도 및 화학종의 농도분포에 의해서도 명확하게 구분되었다. 과환기화재에서 FDS는 온도 및 화학종의 농도에 관한 실험결과를 정량적으로 매우 잘 예측하였다. 반면에 환기부족화재의 경우, 시간 증가에 따른 $CO_2$의 감소 및 CO의 증가와 같은 비정상적 화학적특성의 예측에는 한계가 있음을 알 수 있었다. 그럼에도 불구하고 정상상태 구간의 시간 평균된 온도 및 화학종의 농도는 실험결과를 적절히 잘 예측하였다. 위 결과로 부터 FDS는 과환기 화재 및 환기부족화재의 특성을 예측하는데 매우 유용하게 활용될 수 있음을 알 수 있었다.

아트리움 공간의 효과적인 방화설비 기준연구 (A study on the standard of effective fire facilities for the Atrium)

  • 최돈묵;김재운;민세홍
    • 한국화재조사학회지
    • /
    • 제6권1호
    • /
    • pp.49-66
    • /
    • 2005
  • 이 연구는 아트리움의 방화안전성 고찰 및 적정한 방화 장치의 기준제시를 초점으로 하고 있다. 주요 내용으로는 아트리움 공간의 일반적 고찰, 아트리움 건물의 실례와 방재상의 문제점을 알아보았고, 현재 우리나라 아트리움 공간에 설치되어 있는 방화설비 등을 조사하여 외국의 여러 기준과 비교함으로써 드러난 문제점 및 취약요인을 바탕으로 아트리움 설계 시 특히 유의하여야 할 사항에 대하여 탐구하였다. 여기서 주장한 아트리움 공간의 효과적인 소화설비기준은 다음과 같다. 1 제연 설비는 비상동력이 부설된 기계제연에 의한 강제배연이 알맞다. 2 아트리움 공간과 연결된 다른 부분에서 공기의 유입이 되지 않도록 연결된 부분(1층 제외)을 화재 시 지동으로 구획되는 가동벽 셔터 방화문을 설치한다. 3. 분리형 적외선 감지기를 아트리움 바닥으로부터 7~8m 높이에 설치하여 조기에 화재를 감지하도록 한다. 4. 천장이 20m이하인 아트리움의 경우 아트리움 천장에 개방형 스프링클러헤드를 설치하고 일제개방밸브를 작동시켜 해당구역에 소화수를 집중 방출하게 하며, 천장이 20m이상인 아트리움의 경우 측벽형 헤드를 저층부의 벽체에 설치하여 수평분출로 소화한다. 5. 피난 계단으로의 이동은 아트리움 공간을 지나지 않고 할 수 있도록 설계되어야한다. 6. 일부부재의 내력저하가 생겨도 전체의 붕괴에는 이르지 않게, 아트리움의 철골의 트러스재는 내화재로 보호한다.

  • PDF

지하철 역사내 기능실에 대한 무선 센서 네트워크 성능 분석 (Performance Evaluation of Wireless Sensor Networks in the Subway Station of Workroom)

  • 안태기;신정렬;김갑영;양세현;최갑봉;심보석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1701-1708
    • /
    • 2011
  • 지하철은 대표적인 교통수단으로 하루에도 수십만 명이 이용하고 있어 안전에 대한 관심이 높으며 지하철의 각종 기능실에서의 화재 등으로 이하여 지하철 이용자들에게까지 피해를 입을 수 있는 가능이 제기되고 있는 실정이다. 실제로 2010년에는 환기실에서의 화재로 환기구를 통해 연기 및 유해가스로 인해 인명 피해 및 열차 운행 중단사고 등의 사례까지 보도되기도 하고 있다. 이러한 사고에 대응하기 위해 지하철 역사의 경우에도 최신의 IT기술인 무선센서네트워크기술 및 지능형영상감시기술 등과 접목하여 화재 및 역사 건전성 등을 종합적으로 감시하는 도시철도지능형종합감시시스템 개발 및 연구 중에 있다. 이를 위하여 본 연구에서는 개발 중인 도시철도 지능형 종합 감시시스템의 현장 역사 적용에 앞서 ZigBee 기반의 무선센서네트워크 성능 시험을 서울지하철 충무로 역사에서 수행하였고, 본 논문에 충무로역사 내부 통신기계실과 환기실, 전기실에서의 ZigBee기반 무선통신환경 시험결과를 정리, 분석하였다. (주)휴텍21에서 개발한 ZigBee 센서노드와 게이트웨이를 이용한 무선데이터 전송 시험 결과, 데이터 전송은 기능실 내의 각종 전자 및 기계설비로 인한 멀티패스 페이딩(multi-path fading)의 영향을 받는 것으로 나타났으며 통신기계실과 같이 여러 개의 작은 공간으로 구분되어진 곳에 대한 게이트웨이의 안테나 및 센서노드 설치 지점 선정 시 이를 고려하여야 할 것으로 판단된다.

  • PDF

노즐 위치 및 분사각이 공기유동 및 $CO_2$ 소화제 전달특성에 미치는 영향 (The Effect of Nozzle's Location & Injection Angle on the Characteristics of Air Flow and $CO_2$ Extinguishant Transfer)

  • 박찬수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권4호
    • /
    • pp.472-484
    • /
    • 2002
  • To analyze the characteristics of air flow and $CO_2$ extinguishant transfer when extinguishant is injected into a closed space similar to marine engine room, a numerical simulation on a space was performed. Flow fields and $CO_2$ concentration fields are calculated according with the variation of the location & injection angle of nozzles. The results of simulation showed that the pattern of recirculation flow was affected greatly with the location & injection angle of nozzles and such a recirculation flow accelerated mass transfer of $CO_2$ and greatly affected the diffusion process of $CO_2$ extinguishant. It is considered that this result of this study can be useful to designing the arrangement of nozzles for the $CO_2$ fire fighting equipments in a marine engine room.

철도차량 미분무수 소화설비 성능 평가 (Performance Evaluation on Water-mist Extinguishing System of Railway Vehicles)

  • 박원희;음푸른별;윤경범;이덕희
    • 한국유체기계학회 논문집
    • /
    • 제17권1호
    • /
    • pp.22-27
    • /
    • 2014
  • The test system for the performance of the water-mist extinguishing system in the railway vehicle is equipped and the details of the system are introduced. The three scenarios using different fire sources and performance criteria for the water-mist systems on railway vehicles are also introduced. Three different type of the nozzle at same operating pressure are evaluated. Amount of water-mist distribution is measured by many baskets on the bottom of the test room. Temperature on the ceil and the tree of the test room is measured during the tests that are used for the judgement of the performance on the water-mist extinguishing system.

대와류모사를 이용한 연기이동의 연구 I. 제연방식과 배기풍량 (A Study on Smoke Movement by Using Large Eddy Simulation I. Smoke Control Systems and Extraction Flowrate)

  • 박외철
    • 한국안전학회지
    • /
    • 제18권2호
    • /
    • pp.40-45
    • /
    • 2003
  • To evaluate the smoke control systems, the large eddy simulation turbulence model based Fire Dynamics Simulate was applied to a 2m $\times$ 2m $\times$ 2.4m room with an opening. The smoke removal rate was investigated for three different smoke control systems: ventilation, extraction and pressurization. When the opening was closed, the smoke removal rates of the smoke control systems were almost the same as expected. The pressurization system showed a lower smoke removal rate compared with the other two smoke control systems for the room with the opening, and hence the pressurization system might not be efficient for a place with large openings. It was shown that the lower extraction flowrate is, the longer time the ventilation system requires to remove smoke. From these results, the ventilation system is recommended for subway stations where several large openings exist.

폐기물 소각시설 내부 소음에 관한 연구 (A Study on Noise in Waste Facilities)

  • 서병석;박노국;전용한
    • 대한안전경영과학회지
    • /
    • 제22권2호
    • /
    • pp.15-21
    • /
    • 2020
  • Industrial facilities need design to predict and reduce noise from design to prevent and reduce noise. The purpose of this study is to predict worker's environment and evaluate safety by analyzing noise inside underground blower room and air compressor room with fluid machinery in waste facility. This waste incineration facility was analyzed based on the ground floor, ground floor blower chamber, and air compressor chamber. The results of SPL(Sound Pressure Level) analysis at 1.5m away, which are frequently used to measure the SPL as a noise source, are as follows. SPL of basement level: 46.80[dB], SPL of ground layer: 48.57[dB]. As a result, it was expected that the noise level would be considerably lower than the 8 hours 50[dB] noise exposure per day.

경량칸막이 벽체를 통한 다중구획공간에서의 화재위험성에 관한 연구 (A Study on Fire Hazards in Multiple Compartments with Lightweight Partition Walls)

  • 박상민;최수길;진세영;김시국
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.14-21
    • /
    • 2020
  • 본 논문은 ISO 9705 2/5축소모델 2개를 실내 공간구획에 사용되는 경량칸막이를 이용하여 구획 한 후 ISO 9705 시험을 재현하여 이면부로의 화재위험성에 관한 연구이다. 실험 시료는 시공 시 가장 많이 사용되고 있는 SGP 칸막이, 스터드 칸막이, 그라스울 패널, 우레탄폼 패널, 샌드위치 패널, 유리 칸막이를 선정 하였고, ISO 9705시험 기준에 따라 버너에 점화 전 측정 장치와 데이터의 기록을 시작하여 120 s간 유지시켜 안정화를 취하고, 점화 후 600 s 동안 100 kW, 이후 600 s 동안 300 kW까지 증가하였다가 종료 후 180 s동안 관찰하여 이면부로의 화재 위험성 및 벽체의 화재 패턴을 분석하였다. 점화원에서 발생된 열량으로 인한 최대 이면온도는 SGP 칸막이 67.7 ℃, 스터드 칸막이 55.1 ℃, 그라스울 패널 52.4 ℃, 샌드위치 패널 727.4 ℃, 우레탄폼 패널 561 ℃, 유리 칸막이 630.5 ℃로 측정되었다. 샌드위치 패널과 우레탄폼 패널의 경우 내장재에 용융으로 인한 가연성 가스의 폭발 현상이 발생하였고 강화유리는 수열부와 비수열부의 온도차이로 인하여 유리가 파열되며 인접구획실로의 화재 위험성이 높은 것으로 판단된다.

그라스울 샌드위치패널의 화재 안전 성능에 대한 실험적 연구 (An Experimental Study on Fire Safety Performance of Glass Wool Sandwich Panel)

  • 권오상;유용호;김흥열;민세홍
    • 한국화재소방학회논문지
    • /
    • 제26권5호
    • /
    • pp.21-27
    • /
    • 2012
  • 본 연구에서는 그라스울 샌드위치패널의 연소특성을 판단하기 위하여 밀도와 두께가 다른 총 6종류(밀도: 48/64 K, 두께: 50/75/100 T)의 시편을 선정하여, KS F ISO 9705 시험법을 준용하여 실물화재 시험을 실시하였다. 실물화재 시험은 $2.4(L){\times}3.6(W){\times}2.4(H)m$ 크기의 화재실 내부에 시험체를 설치하여 프로판 버너에 의해 시편을 화염에 노출시켜 연소특성을 판단하게 된다. 총 25분에 시험 시간 동안 프로판 버너는 100 kW(10분), 300 kW(10분)로 출력되며, 시험을 통해 열방출률, 열류량, 내부 온도가 측정된다. 실물화재 시험을 실시한 결과, 버너 열량을 포함하여 각 시편의 최대 열방출률은 333.2~365.5 kW, 최대 열류량은 12.4~12.9 kW/$m^2$로 나타났으며, 최대 내부온도는 모든 시편에서 $500^{\circ}C$를 초과하지 않았다. 실물화재 시험 중에 플래시오버 현상은 발생하지 않았으며, 각 시편의 열방출률, 열류량, 내부 온도 측정결과 시편의 밀도 및 두께에 따른 차이점은 나타나지 않았다.