Abstract

The test system for the performance of the water-mist extinguishing system in the railway vehicle is equipped and the details of the system are introduced. The three scenarios using different fire sources and performance criteria for the water-mist systems on railway vehicles are also introduced. Three different type of the nozzle at same operating pressure are evaluated. Amount of water-mist distribution is measured by many baskets on the bottom of the test room. Temperature on the ceil and the tree of the test room is measured during the tests that are used for the judgement of the performance on the water-mist extinguishing system.