• 제목/요약/키워드: Roof Frame Structure

검색결과 62건 처리시간 0.022초

Conceptual configuration and seismic performance of high-rise steel braced frame

  • Qiao, Shengfang;Han, Xiaolei;Zhou, Kemin;Li, Weichen
    • Steel and Composite Structures
    • /
    • 제23권2호
    • /
    • pp.173-186
    • /
    • 2017
  • Conceptual configuration and seismic performance of high-rise steel frame-brace structure are studied. First, the topology optimization problem of minimum volume based on truss-like material model under earthquake action is presented, which is solved by full-stress method. Further, conceptual configurations of 20-storey and 40-storey steel frame-brace structure are formed. Next, the 40-storeystructure model is developed in Opensees. Two common configurations are utilized for comparison. Last, seismic performance of 40-storey structure is derived using nonlinear static analysis and nonlinear dynamic analysis. Results indicate that structural lateral stiffness and maximum roof displacement can be improved using brace. Meanwhile seismic damage can also be decreased. Moreover, frame-brace structure using topology optimization is most favorable to enhance lateral stiffness and mitigate seismic damage. Thus, topology optimization is an available way to form initial conceptual configuration in high-rise steel frame-brace structure.

전통건축 지붕곡 구조분석을 통한 지붕가구부 설계도구의 구현 (The Implementation of an Roof Structure Generating Tool based on the Structural Analysis of Roof Curvature in Traditional Buildings)

  • 이현민;안은영
    • 한국멀티미디어학회논문지
    • /
    • 제17권3호
    • /
    • pp.393-404
    • /
    • 2014
  • 본 연구는 전통건축 방식의 지붕곡을 전산학적으로 재해석하고 지붕가구부를 구성하는 부재들간의 기하학적 상관관계를 3D 데이터로 설계하기 위한 방안을 제시한다. 지붕곡을 형성하는 여러 개의 구성 요소, 즉 지붕가구부 부재들간의 상관관계를 전통건축 축조 방식에 근거하여 함수식으로 정의하고 분석된 데이터를 토대로 사용자가 원하는 지붕면을 구성하기 위한 각 부재들의 3차원 데이터 자동 생성 기법을 구현한다. 제안하는 방식은 부재간의 상관관계를 고려하여 지붕곡의 속성이 변경되면 지붕곡에 영향을 미치는 여러 개의 부재들이 자동으로 재설계되는 방식으로써 전통건축 설계의 효율을 높일 수 있다. 또한, 한옥의 다양한 지붕곡 설계를 보장하면서도 체계적인 설계와 규격화된 생산 및 가공을 가능하게 하여 한옥의 보급에 크게 기여할 수 있을 것으로 기대된다.

한옥 설계의 최근 경향 연구 - 최근 10년간 건축전문 잡지에 게재된 신축 한옥을 대상으로 - (The Recent Trends of Hanok Design - Based on the Analysis of the Hanoks Appeared in Architecture Magazines in the Last 10 Years -)

  • 이주옥;한필원
    • 건축역사연구
    • /
    • 제21권1호
    • /
    • pp.171-186
    • /
    • 2012
  • The objective of this study is to find out the recent trends of hanok design based on 58 hanoks appeared in architecture magazines in the last 10 years. The cases are analyzed in terms of location, size, building form, spatial organization, material, roof form, and the ceiling form of living room. The consequences of this study is as follows; Most of the recent hanoks are built in rural area (91.4%), which shows the hanok is not accepted as an urban house type. Hanoks tend to be built in 2 stories whose 2nd floor is smaller than the 1st floor. (34.5%) The preferred size is total floor area of $99.2{\sim}165.2m^2$ (62.0%), 3 rooms (46.6%) with a traditional ondol room (60.3%). The buildings with ㄱ-shape (43.1%) and linear-shape (27.6%) are preferred, and the compact plan type similar with apartment house appears (13.8%). In the roof design that greatly influences the appearance of building, the traditional design factors such as half-hipped roof (55.2%), double eaves (27.6%), and eaves curve tend to be sustained. In terms of spatial organization, most of recent hanoks have double-layed plan (74.2%). The living room mostly has separately defined space. (82.8%) The indoor and outdoor tend to be connected by a narrow wooden veranda (39.7%), while some cases don't have any wooden floor space (48.3%). The entrance is adopted as an important spatial element in front part of building (75.9%), and it influences the appearance of building. The living room, the counterpart of the wooden floor hall in traditional hanok, and kitchen tend to be interiorized. In terms of material, the cement roof tile and red clay brick are preferred. Consequently, the walls of recent hanoks have the image of brick structure rather than the wooden frame structure of traditonal hanok.

공간구조물의 성능기초 내진설계에 관한 기초연구: 강구조 골조막 구조의 탄소성 지진응답특성 (A Fundamental Study of Performance Based Seismic Design on the Large Span Structures: The Characteristics of Elasto-Plastic Earthquake Responses of a Steel Frame with Membrane Roof)

  • 중택상이;정명채;가등사랑;길야달시;소전헌사
    • 한국공간구조학회논문집
    • /
    • 제7권2호
    • /
    • pp.35-44
    • /
    • 2007
  • 공간구조물의 성능기초 내진설계를 위한 기초연구의 하나로 강구조 골조막 구조의 탄소성 지진응답 특성을 분석하였다. 하부 골조의 가새의 선행좌굴을 유도하여 상부에의 지진 에너지 전달을 저감할 수 있음을 보여주고 있다.

  • PDF

고무차륜형 AGT 경량전철 차량용 알루미늄 차체의 개발 (Development on the Aluminum Carbody for Rubber-Tired AGT Vehicle)

  • 김연수;박성혁;백남욱;김동승
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1118-1123
    • /
    • 2003
  • Based on the design requirements(size, strength, structure, weight, and etc.) for the rubber-tired AGT vehicle, carbody made of aluminum alloy is designed. The analysis of strength and stiffness is performed in the designed carbody, which results in the modification for optimal shapes and structures. It consists of a under frame, side frame, roof frame, end frame and forehead frame. After the carbody manufactured, tests are performed, which are vertical load test, longitudinal compressive load test, twisting load test, twisting natural frequency measurement, bending natural frequency measurement and 3 points supporting test. Results of them can guarantee a structural safety.

  • PDF

X, Y 방향에 따른 상부벽식-하부골조의 비선형 정적응답특성 (The Response Characteristics of Nonlinear Pushover Analysis of Upper Wall-Lower Frame System with X and Y-Directions)

  • 강병두;전대한;김재웅
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.209-216
    • /
    • 2003
  • The purpose of this study is to investigate the response characteristics of pushover analysis of upper wall-lower frame system with X and Y-directions' lateral load Pushover analysis estimates initial elastic stiffness, post-yielding stiffness, and plastic hinges on each story of structures through three-dimensional nonlinear analysis program. The conclusions of this study are as follows; (1) As a result of pushover analysis, the magnitude of nonlinear response and distribution of yield hinge in lower structure are similar with both X and Y directions, but not in upper structure because of different relative stiffness. (2) The maximum drift ratio of roof is larger for X-direction than for Y-direction with respect to magnitude of shear wall areas in upper structure.

  • PDF

전동차 구조체의 안전성 평가 연구 (On Study the Safety Assessment of Accident Electric Multiple Units)

  • 정종덕;김정국;편장식;김원경;홍용기
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1105-1108
    • /
    • 2004
  • This paper describes the structural analysis result and load test result of accident EMU(Electric Multiple Units). Structural analysis and load test of EMU were performed for the criteria of safety assessment. Structural analysis using commercial I-DEAS software provided important information on the stress distribution and load transfer mechanisms as well as the amount of damages during rolling stock crash. The purpose of the load test is to evaluate a safety which carbody structure shall be considered fully sufficient rigidity so as to satisfy proper system function under maximum load and operating condition. The results have been used to provide the critical information for the criteria of safety assessment.

  • PDF

Shake table tests on a non-seismically detailed RC frame structure

  • Sharma, Akanshu;Reddy, G.R.;Vaze, K.K.
    • Structural Engineering and Mechanics
    • /
    • 제41권1호
    • /
    • pp.1-24
    • /
    • 2012
  • A reinforced concrete (RC) framed structure detailed according to non-seismic detailing provisions as per Indian Standard was tested on shake table under dynamic loads. The structure had 3 main storeys and an additional storey to simulate the footing to plinth level. In plan the structure was symmetric with 2 bays in each direction. In order to optimize the information obtained from the tests, tests were planned in three different stages. In the first stage, tests were done with masonry infill panels in one direction to obtain information on the stiffness increase due to addition of infill panels. In second stage, the infills were removed and tests were conducted on the structure without and with tuned liquid dampers (TLD) on the roof of the structure to investigate the effect of TLD on seismic response of the structure. In the third stage, tests were conducted on bare frame structure under biaxial time histories with gradually increasing peak ground acceleration (PGA) till failure. The simulated earthquakes represented low, moderate and severe seismic ground motions. The effects of masonry infill panels on dynamic characteristics of the structure, effectiveness of TLD in reducing the seismic response of structure and the failure patterns of non-seismically detailed structures, are clearly brought out. Details of design and similitude are also discussed.

건축구조물의 비선형 지진응답 산정을 위한 내진성능평가 방법의 비교 (Comparison of Performance Evaluation Methods Based on the Estimation of Nonlinear Seismic Responses for Multistory Building)

  • 최원호;이동근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.349-356
    • /
    • 2002
  • There has been an increasing trend toward the use of pushover analysis as a tool for evaluating the seismic resistant and safety of a building structure in the performance based earthquake engineering field. The ATC-40 document proposed a nonlinear static procedure based on the Capacity Spectrum Method to determine earthquake-induced demand given the structure pushover curve, which a curve representing base shear versus roof displacement. However, the procedure is conceptually simple, iterative and time consuming method and may sometimes lead to no solution or multiple solutions. A new improved method of seismic performance evaluation for moment frame building, which take into account the previously mentioned deficiencies of currently used elastic design procedures, is presented in this paper. The results of nonlinear static and nonlinear time history analysis of an example high-rise steel moment frame designed by the proposed method are presented and discussed.

  • PDF

석조유구(石造遺構)를 통한 한국(韓國) 고대건축(古代建築)에 관한 연구(硏究) -삼국시대와 통일신라시대를 중심으로- (A Study on the Ancient Architecture in view of the Stone Remains (focused on the 3 Kingdom Period and Unificated Shilla Period))

  • 천득염;박지민
    • 건축역사연구
    • /
    • 제8권3호
    • /
    • pp.23-38
    • /
    • 1999
  • The purpose of this study is to analogize the appearance of Korean Ancient Architecture in view of the Stone Remains from 3 Kingdom Period to Unificated Shilla Period. But in these period, there is no building remains but some stupas and fine arts. Especially, there are many architectural appearance and revealing signature in these Historical Stone remains. Architectural elements which are analogized by stone remains what has value as historical materials by preservation of original form from 3 Kingdom Preiod to Unificated Shilla Period are as follows : 1) Platform, the representative characteristic of Korean traditional architecture, was frame structure and accumulate structure. And circular or square footing stood a same shape column on it is put on the platform. 2) In the case of column, there used entasis column and inclined column and circular chamfer technique was applied on the top side of it. Upper side of column, capital and head pentrating tie that small bearing block was put on the center of it was joined. And longitu야nal rest(長舌) supported a cross beam. Capital and small bearing block had no bottom heel, and heel side was curved and straight. Centered bracket structure was often used, and multi bracket structure is not used yet. Inward incline technique was used. 3) Inward opening pair door which had lintel, threshold, doorjamb was usually used, Fixing stone was used for structural safety, and circular handle and lock was used for decoration. Handrail was used on the edge of wooden floor for decorative effect and safety. 4) Square rafter and circular rafter were used in the same period and so did flying rafter. Double eaves and single eave were used in the same period but, single eave was usually used. In this period, square rafter was usually used. This would be studied more by comparing with Japanese wooden architecture. 5) Hipped roof was used and half-hipped roof was not used yet. In front of th hip, there are small sculpture called Jap-Sang(雜像), and windbell was hang on the end of the hip rafter. Concave roof tile, convex roof tile, round eaver tile, decorative tile at end of roof ridge were used. Lotus style was well used on the face of roof tile for decoration. From the results of this study, wooden architecture of Unificated Shilla period was simple compare to Koryo dynasty and Chosun dynasty but, it had some brilliant character. It was hard work that analogized the form of non-existent wood architecture of Ancient Korean period by restricted stone remains. But, in addition to the results of this study and research of old documentations, more study should be go on.

  • PDF