• Title/Summary/Keyword: Risk facilities

Search Result 1,021, Processing Time 0.032 seconds

Risk Assessment of Escherichia coli Infection from Use of Interactive Waterscape Facilities (수경시설 물놀이에 따른 대장균 감염의 위해도 분석)

  • Zo, Young-Gun
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.1
    • /
    • pp.73-81
    • /
    • 2012
  • Objectives: With the goal of quantifying the risk of children contracting gastroenteritis while playing at interactive waterscape facilities and evaluating the adequacy of current water quality regulations, risk assessment was performed with Escherichia coli as pathogen. Methods: Abundances of E. coli in the waters of interactive water features in South Korea were acquired from survey reports. A gamma distribution describing the volume of water swallowed by children during swimming activities was adopted. Exposure rate and risk were calculated by Monte Carlo simulation and dose-response models for various pathogenic E. coli. Results: E. coli was detected in 25 out of 40 facilities, with range of ~1,600 CFU/100 ml. The abundance fitted an exponential distribution. Simulated exposures ranged ${\sim}1.9{\times}10^{10}$ CFU, varying greater along E. coli abundance than the volume of water. Risk of children being infected by enterohemorrhagic E. coli was high, with range of ~0.85. When E. coli abundance was <200 CFU/100 ml, which is the current government threshold, the risk decreased to <0.43. Although the guideline successfully reduced the risk of adults being infected by a less virulent E. coli strains (<0.03), the risk for children could not be quantified due to lack of dose-response models for those pathogens for children. Conclusions: Under the current guideline, children are at risk of being infected if water is contaminated with by enterohemorrhagic E. coli. For other E. coli strains, the risk appears to be considerably less. The result warrants need for developing dose-response models for children for each pathogenic E. coli strain.

Risk and culture: variations in dioxin risk perceptions, behavioral preferences among social groups in South Korea

  • Park, Seohyun;Kim, Jong Guk
    • Environmental Analysis Health and Toxicology
    • /
    • v.29
    • /
    • pp.13.1-13.11
    • /
    • 2014
  • Objectives This study examined variations in the perceptions of dioxin risk among social groups defined by geographical living location, environmental education, and occupation. Dioxin risk perceptions were analyzed according to values, risk awareness, knowledge, and behavioral preferences. Methods A quasi-experimental survey was designed and conducted on individuals from seven experimental groups in Jeonju city, South Korea, including: people living near incineration facilities; people living far from incineration facilities; governmental experts; non-governmental organization members; office workers in developmental institutes or banks; students who were enrolled in environmental-related classes; and students who were enrolled in business-related classes. Results The results show variations among groups in values, awareness and behavioral preferences. Particular attention should be given to the result that groups with higher connectedness-to-nature values show higher willingness-to-act (WTA) for risk reduction. Result s can be summarized as follows. First, awareness is associated with one's geographical setting. Second, values and WTA behaviors are related to one's environmental-related education and occupation. Third, values are significantly related to WTA behaviors. Conclusions Different cultures, in terms of values or worldview, among groups influence their perceptions of dioxin risk and choices of risk reduction behaviors. It is important to consider values in communicating complicated long-term risk management involving public participation. Further research should be continuously conducted on the effects of multiple dimensions of values on one's WTA for risk reduction behaviors.

Risk Analysis of Ammonia Leak in the Refrigeration Manufacturing Facilities (냉동제조 시설의 암모니아 누출사고 위험 분석)

  • Kang, Su-Jin;Lee, Ik-Mo;Moon, Jin-Young;Chon, Young-Woo
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.1
    • /
    • pp.43-51
    • /
    • 2017
  • Recently, ammonia leak occurred frequently in the domestic refrigeration manufacturing facilities. Ammonia caused great damage to the environment and human health in the event of an accident as combustible gases and toxic gases. After considering the types of ammonia accidents of domestic refrigeration manufacturing facilities and selected accident scenarios and to analyze the risk analysis through Impact range estimates and frequency analysis and there was a need to establish measures to minimize accident damage. In this study, depending on the method of analysis quantitative risk assessment we analyzed the risk of the receiver tank of ammonia system. Scenario analysis conditions were set according to the 'Technical guidelines for the selection of accident scenario' under the chemicals control act and 'Guidelines for chemical process quantitative risk analysis' of center for chemical process safety. The risk estimates were utilized for consequence analysis and frequency analysis by SAFETI program of DNV, event tree analysis methodology and part count methodology. The individual risk of ammonia system was derived as 7.71E-04 / yr, social risk were derived as 1.17E-03 / yr. The derived risk was confirmed to apply as low as reasonably practicable of the national fire protection association and through risk calculation, it can be used as a way to minimize accidents ammonia leakage accident damage.

Health Risk Assessment of Occupants in the Small-Scale Public Facilites for Aldehydes and VOCs (일부 미적용 다중이용시설의 실내 공기 중 알데히드류 및 휘발성유기화합물 노출로 인한 건강위해성 평가)

  • Yang, Ji-Yeon; Kim, Ho-Hyun;Shin, Dong-Chun;Kim, Yoon-Shin;Sohn, Jong-Ryeul;Lim, Jun-Hwan;Lim, Young-Wook
    • Journal of Environmental Science International
    • /
    • v.17 no.1
    • /
    • pp.45-56
    • /
    • 2008
  • This study was to assess the lifetime cancer and non-cancer risk of exposure of worker and user at public facilities in Korea to volatile organic compounds (VOCs). We measured the concentrations of two aldehydes and five VOCs in indoor air at 424 public buildings that 8 kinds of public facilities (70 movie theaters, 86 offices, 86 restaurants, 70 academies, 22 auditoriums, 30 PC-rooms, 30 singing-rooms and 30 bars) all over the country. There were estimated the human exposure dose and risks with averages of the using-time and frequency for facility users and office workers, respectively. Carcinogens (formaldehyde, acetaldehyde, and benzene) were estimated the lifetime excess cancer risks (ECRs). non-carcinogens (toluene, ethylbenzene, xylene, and styrene) were estimated the hazard quotients (HQs). The average ECRs of formaldehyde and benzene for facility worker and user were $1{\times}10^{-3}{\sim}1{\times}10^{-4}\;and\;1{\times}10^{-4}{\sim}1{\times}10^{-5}$ level, respectively, in all facilities. HQs of four non-carcinogens did not exceed 1.0 for all subjects in all facilities. The estimated ECRs for restaurant and auditorium were the highest, and the PC-room and bar were the next higher facilities. Furthermore, people in a smoking facility had the highest cancer risk. Higher ECRs of formaldehyde and benzene were observed in indoor smoking facilities such as restaurant and auditorium. Higher HQs of toluene and xylene were observed at the restaurant and office building.

Health Risk Assessment of Aldehydes and VOCs in the Activities Space of Young Children -Focused on Child-care Facilities and Indoor Playgrounds- (어린이 주요 활동 공간의 휘발성 유기화합물 노출로 인한 건강 위해성 평가 -보육시설 및 실내놀이터 중심으로-)

  • Yang, Ji-Yeon;Kim, Ho-Hyun;Yang, Su-Hee;Kim, Sun-Duk;Jeon, Jun-Min;Shin, Dong-Chun;Lim, Young-Wook
    • Environmental Analysis Health and Toxicology
    • /
    • v.25 no.1
    • /
    • pp.57-68
    • /
    • 2010
  • This study assessed the lifetime cancer and non-cancer risk of aldehydes and volatile organic compounds exposure of young children at child-care facilities and indoor playgrounds in Korea. The samples were collected at various children's facilities (40 day-care houses, 42 child-care centers, 44 kindergartens, and 42 indoor playgrounds) in summer (Jul~Sep, 2007), winter (Jan~Feb, 2008) and Spring (Mar~Apr, 2008) periods, and analyzed by GC-MS. We estimated the lifetime excess cancer risks (ECRs) of formaldehyde, acetaldehyde, benzene, chloroform, CCI4 and tetrachloroethylene, and the hazard quotients (HQs) of Non-carcinogens (toluene, xylene, benzaldehyde and formaldehyde). Formaldehyde evaluated both cancer and non-cancer risk. The average ECRs of formaldehyde for young children were $1\times10^{-4}{\sim}1\times10^{-5}$ level in all facilities. HQs of four non-carcinogens did not exceed 1.0 for all subjects in all facilities.

Development of Risk Assessment Index in Special Management Target Facilities According to the Fire Occurrence Factors (화재발생 요인에 따른 특정관리대상시설등의 위험도 평가 지수의 분석 및 개발)

  • Park, Mi Yun;Park, Jong Bok;Park, Jae Hak
    • Journal of Korean Society of Disaster and Security
    • /
    • v.5 no.2
    • /
    • pp.61-70
    • /
    • 2012
  • The range of special management target facilities is seperated by the building sector and the field of civil engineering. In the present study, the risk analysis was performed, related to fire occurred for the last five years, in the field of residential and non-residential facilities in buildings. Most of fire incidents occurred in residential and non-residential facilities was the cause of the electrical, and the resulting casualties were also very high. Therefore, based on the results, the risk evaluation index was developed, identifying the causes of fire occur and doing the fire vulnerability analysis for each facility. The result of this study can be utilized safety management to these facilities for the future, especially, inducing a more specialized and intensive safety management.

A Study on the Analysis of Evacuation Risk by Building Application for Fire Safety (화재안전을 위한 건축물 용도별 피난리스크 분석에 관한 연구)

  • Jin, Seung-hyeon;Koo, In-Hyuk;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.164-165
    • /
    • 2021
  • In Korea, in the case of fire scenarios in performance design, it is assumed that the sprinkler is not working. In addition, it does not applicate various fire conditions. Therefore it is not enough that the accuracy about fire scenario. In foreign countries, reseach is being conducted to predict the casualities that can occur due to fire in the building space through statistical risk analysis. Also, research is consistently conducting for design that consider the sprinker probability of operation. Therefore, to analyze the fire risk of each building in Korea, the risk was analyzed using statistical data. As a result, the risk of casualties that can occur for each building use was analyzed as 0.6(persons/cases) for residential buildings, 0.25(persons/cases) for sales facilities, and 0.12(persons/cases) for buisiness facilities.

  • PDF

Analysis on Visibility Range of Forest Fire Detection Facilities for Forest Fire Prevention (산불예방을 위한 감시시설 가시범위 분석에 관한 연구)

  • Lee, Si-Young;An, Sang-Hyun
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.157-160
    • /
    • 2008
  • This study analyzed on the area of Samcheok, Kangwondo about forest fire alarming area and enlargement of the area. Then, visible area by unattended watching camera and watchtower for forest fire which were run by Samcheok was cross-checked with geographic information system, and it could be whether effective on watching the area where the forest fire risk was high enough and also it could be expanded to larger forest fire. The result of study, the visible area by watching facilities only holds for 13.4% of the whole forest fire alarming area, but the forest fire can be observed even though it is occurred in small valley because of smoke and all the forest fire have been occurred in daytime. Therefore, it can be determined that watching area will be extended around 50.3% while the observation radii of watching facilities raise by 4km. However, Samcheok has much greater area of mountain area in compared to any other cities or counties, watching facilities should be installed and run additionally for extinguishing the forest fire from the beginning.

  • PDF

Human Risk Assessment for Exposure to Heavy Metals within Finishing Materials of Playground Facilities for Children in Gwangju (광주지역 어린이 놀이시설 마감재의 중금속 노출에 의한 인체 위해성평가)

  • Sang-Hoon Yoon;So-Young Kim;Eun Cho;Tae-Hui Nam;Jin-Hwan Park;Hwa-Jin Kong;Ki-Won Lee;Gwang-Yeob Seo;Jeong-Hun Park;Kyoung-Woo Min
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.2
    • /
    • pp.146-156
    • /
    • 2024
  • Background: Children who use playground facilities are exposed to potential risks due to the high concentration of heavy metals contained in the finishing materials of facilities in children's playgrounds. Objectives: The purpose of this study was to investigate the concentration of heavy metals in the finishing materials of outdoor children's playgrounds where harmful heavy metals exist in Gwangju and to conduct human risk assessment for children and adults by age to find the risks and limitations. Methods: The bottom and top layers of double-painted paint were peeled off and collected together from the finishing materials of children's play facilities such as slides, swings, and seesaws in 147 children's parks in Gwangju. Heavy metals were analyzed using ICP-OES, etc., and human risk assessment was performed using the concentrations of heavy metals. Results: Based on 1.0E-04, which requires legal regulation, CTE was found to pose a carcinogenic risk for preschool children and no carcinogenic risk for the rest of the age groups. However, RME showed that both men and women of all ages had a carcinogenic risk. For reference, when the carcinogenic risk was based on 1.0E-06, CTE was found to pose a carcinogenic risk from infants to elementary school students, and RME was found to have a carcinogenic risk in all age groups. It was judged that there is a non-carcinogenic risk if the non-carcinogenic risk exceeds 1 based on the hazard index (HI) 1. In CTE, there was no non-carcinogenic risk, and RME for preschooler males (1.49E+00) and females (1.56E+00) were found to have non-carcinogenic risk. Conclusions: This study was meaningful in that it examines the differences in the current management of heavy metals concentration standards and potential carcinogenic and non-carcinogenic risks to the human body and discusses the relationship between heavy metals and human health effects.