• 제목/요약/키워드: Ring Finger

검색결과 140건 처리시간 0.019초

The Ring-H2 Finger Motif of CKBBP1/SAG Is Necessary for Interaction with Protein Kinase CKII and Optimal Cell Proliferation

  • Kim, Yun-Sook;Ha, Kwon-Soo;Kim, Young-Ho;Bae, Young-Seuk
    • BMB Reports
    • /
    • 제35권6호
    • /
    • pp.629-636
    • /
    • 2002
  • Protein kinase CKII (CKII) is required for progression through the cell division cycle. We recently reported that the $\beta$ subunit of protein kinase CKII ($CKII{\beta}$) associates with CKBBP1 that contains the Ring-H2 finger motif in the yeast two-hybrid system. We demonstrate here that the Ring-H2 finger-disrupted mutant of CKBBP1 does not interact with purified $CKII{\beta}$ in vitro, which shows that the Ring-H2 finger motif is critical for direct interaction with $CKII{\beta}$. The CKII holoenzyme is efficiently co-precipitated with the wild-type CKBBP1, but not with the Ring-H2 finger-disrupted CKBBP1, from whole cell extracts when epitope-tagged CKBBP1 is transiently expressed in HeLa cells. Disruption of the Ring-H2 finger motif does not affect the cellular localization of CKBBP1 in HeLa cells. The increased expression of either the wild-type CKBBP1 or Ring-H2 finger-disrupted CKBBP1 does not modulate the protein or the activity levels of CKII in HeLa cells. However, the stable expression of Ring-H2 finger-disrupted CKBBP1 in HeLa cells suppresses cell proliferation and causes the accumulation of the G1/G0 peak of the cell cycle. The Ring-H2 finger motif is required for maximal CKBBP1 phosphorylation by CKII, suggesting that the stable binding of CKBBP1 to CKII is necessary for its efficient phosphorylation. Taken together, these results suggest that the complex formation of $CKII{\beta}$ with CKBBP1 and/or CKII-mediated CKBBP1 phosphorylation is important for the G1/S phase transition of the cell cycle.

척골 지단 신경의 전기생리학적 연구 (An Electrophysiologic Study on the Ulnar Digital Nerves)

  • 김종순;이현옥;안소윤;구봉오;남건우;김호봉;류재관;류재문
    • 대한정형도수물리치료학회지
    • /
    • 제11권2호
    • /
    • pp.13-18
    • /
    • 2005
  • The ulnar nerve extends down the arm, across the elbow, and into the hand. It provides sensation to the little and ring fingers and activates many of the small muscles in the hand. The determination of peripheral nerve conduction velocity is an important part of ulnar nerve evaluation. The electrodiagnostic value as neurophysiologic investigative procedure has been known for many years but normal value of digital nerve was not reported in Korea. The purpose of this investigation was to measure the digital nerve conduction velocity of ulnar nerve for obtain clinically useful reference value and compare difference in each fingers and then compare with the other countries. 71 normal Korean volunteers (age, 19-65 years; 142 hands) examined who has no history of peripheral neuropathy, diabetic mellitus, chronic renal failure, endocrine disorders, anti-cancer medicine, anti-tubercle medicine, alcoholism, trauma, radiculopathy. Nicolet Viking II (EMG machine) was use for detected conduction velocity and amplitude of digital nerves in ulnar nerve. Data analysis was performed using SPSS. Descriptive analysis was used for obtain mean and standard deviation and independent t-test was used to compare with ring and little finger. Conduction velocity of the right ring finger was 57.44m/sec and little finger was 55.32msec. The left ring finger was 55.55msec and little finger was 54.11msec. Amplitude of the right ring finger was $30.28{\mu}V$ and little finger was $48.36{\mu}V$. The left ring finger was $30.67{\mu}V$ and little finger was $52.76{\mu}V$. There were significantly difference between ring and little in amplitude (p<.05) but there were no statistically difference between conduction velocity of ring and little finger (p>.05). The amplitude of little finger are greater than ring finger. The present results revealed that electodiagnosis can easily perform in little finger for digital nerve of ulnar nerve study.

  • PDF

반지착용이 손씻기 후의 미생물 수와 유형에 미치는 영향 (The Number and Type of Microorganisms on the Ring Finger after Handwashing)

  • 정인숙
    • 기본간호학회지
    • /
    • 제5권1호
    • /
    • pp.143-154
    • /
    • 1998
  • Background : There have been very few studies conducted on the number and type of microorganisms that remain on the ring finger after handwashing. This study was performed to investigate whether there were changes and differences in the type and number of microorganisms on the ring finger before and after handwashing. Method : The subjects of the study were 15 MICU and SICU staff nurses who were wearing rings. I swabbed two different fingers of the same hand with cotton balls. One finger which had a ring and the other with no ring. I swabbed the fingers of each subject three times(before handwashing, after handwashing with soap, and after handwashing with bethadine solution). After storing them for 48 hours in an incubator, I sent them to the laboratory and recorded the culture results. Results : There was no difference in the type of microorganism, but a major difference in the number of the microorganisms that existed on the finger ring. The results showed that there were much more microorganisms on the ring fingers than on the fingers that did not have rings both before and after handwashing. This tendency was consistent regardless of the handwashing agent. I therefore recommend that all nursing staff who work in general nursing units, as well as nurses who work in the ICU, remove their rings when taking care of the patients.

  • PDF

수공구 손잡이 형태에 따른 청.노년층의 악력과 손가락 힘 및 편안함 분석 (Grip Force, Finger Force, and Comfort analyses of Young and Old People by Hand Tool Handle Shapes)

  • 공용구;손성태;김대민;정명철
    • 대한인간공학회지
    • /
    • 제28권2호
    • /
    • pp.27-34
    • /
    • 2009
  • The purpose of this study was to evaluate aging (young and old), gender (male and female), and handle shape effects on grip force, finger force, and subjective comfort. Four handle shapes of A, D, I, and V were implemented by a multi-finger force measurement (MFFM) system which was developed to measure every finger force with different grip spans. Forty young (20 males and 20 females) and forty old (20 males and 20 females) subjects participated in twelve gripping tasks and rated their comfort for all handles using a 5-point scale. Grip forces were calculating by summation of all four forces of the index, middle, ring and little fingers. Results showed that young males (283.2N) had larger gripping force than old males (235.6N), while young females (151.4N) had lower force than old females (153.6N). Young subjects exerted the largest gripping force with D-shape due to large contribution of the index and middle fingers and the smallest with A-shape; however, old subjects exerted the largest with I-shape and the smallest with V-shape due to small contribution of the ring and little fingers. As expected, the middle finger had the largest finger force and the little finger had the smallest. The fraction of contribution of index and ring fingers to grip force differed among age groups. Interestingly, young subjects provided larger index finger force than ring finger force, whereas old subjects showed that larger ring finger forces than index finger force in the griping tasks. In the relationship between performance and subjective comfort, I-shape exerting the largest grip force had less comfort than D-shape producing the second largest grip force. The findings of this study can provide guidelines on designing hand tool handle to obtain better performance as well as users' comfort.

테스토스테론에 의한 심장 질환자의 무명지 길이 분석 연구 (A Study on the Ring Finger Length Analysis of Heart Diseases Patient's by the Testosterone)

  • 김봉현;조동욱
    • 한국통신학회논문지
    • /
    • 제36권7B호
    • /
    • pp.841-847
    • /
    • 2011
  • 테스토스테론은 심장을 보호하는 역할을 수행하는 남성 호르몬으로 적당량이 분비되면 건강하지만 너무 적게 분비되면 신체기관에 악영향을 미치게 된다. 특히, 테스토스테론의 분비량이 정상 수치보다 적게 되면 동맥경화가 일어날 확률이 높아지고 이로 인해 심장 질환을 유발하게 된다. 이와 같은 테스토스테론은 남성의 무명지 길이에 영향을 주며 분비량에 따라 무명지 길이에 차이가 발생한다. 따라서 본 논문에서는 심장 질환자와 정상인을 대상으로 피실험자 집단을 구성하고 이들의 무명지 길이와 검지 길이를 측정하여 상호간의 비교, 분석을 통해 무명지의 길이와 심장 질환과의 상관성 분석 연구를 수행하였다.

Biometric analysis hand parameters in young adults for prosthetic hand and ergonomic product applications

  • Gkionoul Nteli Chatzioglou;Yelda Pinar;Figen Govsa
    • Anatomy and Cell Biology
    • /
    • 제57권2호
    • /
    • pp.172-182
    • /
    • 2024
  • This study aimed to evaluate the superficial anatomy, kinesiology, and functions of the hand to reveal its morphometry and apply the findings in various fields such as prosthetic hand and protective hand support product design. We examined 51 young adults (32 females, 19 males) aged between 18-30. Hand photographs were taken, and measurements were conducted using ImageJ software. Pearson correlation analysis was performed to determine the relationship between personal information and the parameters. The results of the measurements showed the average lengths of finger segments: thumb (49.5±5.5 mm), index finger (63.9±4.1 mm), middle finger (70.7±5.2 mm), ring finger (65.5±4.8 mm), and little finger (53.3±4.3 mm). Both females and males, the left index finger was measured longer than the right index finger. The right ring finger was found to be longer than the left in both sexes. Additionally, length differences between fingers in extended and maximally adducted positions were determined: thumb-index finger (56.1±6.2 mm), index-middle finger (10.7±4.1 mm), middle-ring finger (10.8±1.4 mm), and ring-little finger (25.6±2.7 mm). Other findings included the average radial natural angle (56.4°±10.5°), ulnar natural angle (23.4°±7.1°), radial deviation angle (65.2°±8.2°), ulnar deviation angle (51.2°±9.6°), and grasping/gripping angle (49.1°±5.8°). The average angles between fingers in maximum abduction positions were also measured: thumb-index finger (53.4°±6.5°), index-middle finger (17.2°±2.6°), middle-ring finger (14.3°±2.3°), and ring-little finger (32.1°±7.0°). The study examined the variability in the positioning of proximal interphalangeal joints during maximum metacarpophalangeal and proximal interphalangeal flexion, coinciding with maximum distal interphalangeal extension movements. The focal points of our observations were the asymmetrical and symmetrical arches formed by these joints. This study provides valuable hand parameters in young adults, which can be utilized in various applications such as prosthetic design, ergonomic product development, and hand-related research. The results highlight the significance of considering individual factors when assessing hand morphology and function.

Lack of RING Finger Domain (RFD) Mutations of the c-Cbl Gene in Oral Squamous Cell Carcinomas in Chennai, India

  • Rajendran, Senthilnathan;Muthupalani, Rajendran Shanmugam;Ramanathan, Arvind
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권2호
    • /
    • pp.1073-1075
    • /
    • 2013
  • Background: In normal cells, activated epidermal growth factor receptor (EGFR) molecules are subjected to ubiquitination-mediated proteasome degradation pathway by c-Cbl, an ubiquitin ligase that checks uncontrolled proliferation. Hence expression of wild type c-Cbl molecule is essential to keep this degradation machinery in a functional state. Loss of expression or function of c-Cbl may consequently lead to sustained activation of EGFR and promote carcinogenesis, loss of function mutations in the c-Cbl gene already being reported in lung and hematopoietic cancers. However, the genetic status of c-Cbl in oral squamous cell carcinoma (OSCC) is not known. Hence in the present study we investigated the genomic DNA isolated from OSCC tissue biopsy samples for mutations in the RING finger domain coding region of c-Cbl gene, which has also been reported to be most frequently mutated in other cancers. Materials and Methods: Total genomic DNA isolated from thirty two post surgical OSCC tissue samples were amplified using primers flanking the exon 8 of c-Cbl gene that codes for the RING finger domain. The PCR amplicons were then resolved in a 1.2% agarose gel, purified and subjected to direct sequencing to screen for mutations. Results: The sequencing data of the thirty two OSCC samples did not identify mutations in the RING finger domain coding region of c-Cbl gene. Conclusions: To the best of our knowledge, this is the first time that the genetic status of c-Cbl gene in OSCC samples has been investigated. The present data indicates that genetic alteration of RING finger domain coding region of c-Cbl gene is relatively infrequent in OSCC samples.

정상 성인의 정중지단신경에 대한 전기생리학적 연구 (An Electrophysiologic Study on the Median Digital Nerves in Healthy Adults)

  • 김종순;이현옥;안소윤;구봉오;남건우;류재관;류재문
    • The Journal of Korean Physical Therapy
    • /
    • 제17권3호
    • /
    • pp.329-338
    • /
    • 2005
  • The determination of peripheral nerve conduction velocity is an important part to electrodiagnosis. Its value as neurophysiologic investigative procedure has been known for many years but normal value of digital nerve was not reported in Korea. To evaluate of digital nerve conduction velocity of median nerve for obtain clinically useful reference value and compare difference in each fingers. 71 normal volunteers(age, 19-65 years; 142 hands) examined who has no history of peripheral neuropathy, diabetic mellitus, chronic renal failure, endocrine disorders, anti-cancer medicine, anti-tubercle medicine, alcoholism, trauma, radiculopathy. Nicolet Viking II was use for detected conduction velocity and amplitude of digital nerves in median nerve. Data analysis was performed using SPSS. Descriptive analysis was used for obtain mean and standard deviation, ANOVA was used to compare each fingers and independent t-test was used to compare between Rt and Lt side also compare between different in genders. Conduction velocity of the right thumb was 49.77m/sec, index finger was 56.80m/sec, middle finger was 56.15m/sec and ring finger was 53.38m/sec. The left thumb was 50.48m/sec, index finger was 56.76m/sec, middle finger was 55.99m/sec and ring finger was 53.23m/sec. Amplitude of the right thumb was $64.30{\mu}V$, index finger was $73.95{\mu}V$, middle finger was $77.97{\mu}V$ and ring finger was $43.92{\mu}V$. The left thumb was $74.21{\mu}V$, index finger was $85.72{\mu}V$, middle finger was $88.06{\mu}V$ and ring finger was $47.28{\mu}V$. There were significantly difference between thumb, index, middle and ring fingers(p<.01) but there were no statistically difference between conduction velocity and amplitude of index and middle fingers(p>.01). The conduction velocity of index finger are faster than other fingers and amplitude of middle finger are greater than other fingers. The present results revealed that electodiagnosis can easily perform in index and middle finger for digital nerve of median nerve study.

  • PDF

도서형 신경 혈관 피판을 이용한 수지의 피부 및 연부조직 결손의 재건술 (Neurovascular Island Graft for Finger Tip Loss)

  • 정덕환;한정수;김기봉
    • Archives of Reconstructive Microsurgery
    • /
    • 제10권2호
    • /
    • pp.99-104
    • /
    • 2001
  • Purpose : Loss of sensibility over the finger tip resents a grave deficit and is an indication for sensible soft tissue reconstruction. This paper was performed to assess the long term results obtained by nerovascular island flap. Material and Methods : We performed neurovascular island graft for defective sensibility of finger tip loss in 94 cases since 1979 to 2000. The recipient sites were the thumb pulp defect in 79 cases, the amputated thumb in 9 cases, the amputated index in 4 cases, and the velar aspect of interphalangeal joint of thumb in 2 cases. The donor flaps were obtained from the radial side of ring finger in 63 cases, the ulnar side of the ring finger in 21 cases, and the ulnar side of the middle finger in 10 cases. A mean follow-up period was 5.7 years. Results : The flap quality was well vascularized and survived in 89 cases. The two-point discrimination was average 8.7mm. Because of scar contracture, the range of motion of the donor finger was decreased 3.5% of the normal finger in the distal interphalangeal joint, 8,2% in the proximal interphalangeal joint. A phenomenon of double sensibility occurred in 66 cases. Conclusion : This technique was excellent both aesthetically and functionally as a reconstruction of the Loss of fingertip.

  • PDF

Evaluation of the Contributions of Individual Finger Forces in Various Submaximal Grip Force Exertion Levels

  • Kong, Yong-Ku;Lee, Inseok;Lee, Juhee;Lee, Kyungsuk;Choi, Kyeong-Hee
    • 대한인간공학회지
    • /
    • 제35권5호
    • /
    • pp.361-370
    • /
    • 2016
  • Objective:The aim of this study is to evaluate contributions of individual finger forces associated with various levels of submaximal voluntary contraction tasks. Background: Although many researches for individual finger force have been conducted, most of the studies mainly focus on the maximal voluntary contraction. However, Information concerning individual finger forces during submaximal voluntary contraction is also very important for developing biomechanical models and for designing hand tools, work equipment, hand prostheses and robotic hands. Due to these reasons, studies on the contribution of individual finger force in submaximal grip force exertions should be fully considered. Method: A total of 60 healthy adults without any musculoskeletal disorders in the upper arms participated in this study. The young group (mean: 23.7 yrs) consisted of 30 healthy adults (15 males and 15 females), and the elderly group (mean: 75.2 yrs) was also composed of 30 participants (15 males and 15 females). A multi-Finger Force Measurement (MFFM) System developed by Kim and Kong (2008) was applied in order to measure total grip strength and individual finger forces. The participants were asked to exert a grip force attempting to minimize the difference between the target force and their exerted force for eight different target forces (5, 15, 25, 35, 45, 55, 65, and 75% MVCs). These target forces based on the maximum voluntary contraction, which were obtained from each participant, were randomly assigned in this study. Results: The contributions of middle and ring fingers to the total grip force represented an increasing trend as the target force level increased. On the other hand, the contributions of index and little fingers showed a decreasing trend as the target force level increased. In particular, Index finger exerted the largest contribution to the total grip force, followed by middle, ring and little fingers in the case of the smallest target force level (5% MVC), whereas middle finger showed the largest contribution, followed by ring, index and little fingers at the largest target force levels (65 and 75% MVCs). Conclusion: Each individual finger showed a different contribution pattern to the grip force exertion. As the target force level increase from 5 to 75% MVC, the contributions of middle and ring fingers showed an increasing trend, whereas the contributions of index and little fingers represented a decreasing trend in this study. Application: The results of this study can be useful information when designing robotic hands, hand tools and work equipment. Such information would be also useful when abnormal hand functions are evaluated.